My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7898 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7898 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:54:16 PM
Creation date
2/19/2025 1:10:48 PM
Metadata
Fields
Template:
Building Plans
Street #
7898
Location
Gall Blvd
Contractor
Schaefer General Contracting
Building Plans - Permit #
313
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL CONTRACTOR TO PROVIDE ALL <br />CONTROL WIRING FOR REFRIGERATION SYSTEM <br />AND TO JUNCTION BOX IF APPLICABLE. <br />BUILDING SPRINKLER CONNECTION, IF <br />REQUIRED. SEAL ALL PENETRATIONS. <br />JUNCTION BOX AND CONDUIT BUILT IN WALL <br />PANEL FOR LIGHT SWITCH, PERIMETER <br />HEATER WIRE AND DIGITAL THERMOMETER. <br />ELECTRICAL CONTRACTOR TO WIRE TIME <br />CLOCK TO REFRIGERATION SYSTEM. VERIFY <br />LOCATION OF TIME CLOCK WITH OWNER. <br />WALK-IN COOLER TO BE 2" FROM WALL <br />ON ALL APPLICABLE SIDES <br />GENERALNOTES <br />ALL INTERCONNECTING CONDUIT TO BE RUN ABOVE WALK-IN. EXPOSED INTERIOR CONDUIT WILL NOT BE <br />ACCEPTABLE EXCEPT FOR THE CONDITIONS SHOWN AND NOTED IN THE ABOVE ILLUSTRATION. <br />SEAL ALL PENETRATIONS THRU-OUT WALK-IN. SEAL ALL INSIDE ELECTRICAL CONDUIT WITH THERMAL PLASTIC. <br />PROVIDE HOLE FOR SPRINKLER HEAD (IF REQUIRED) AND AFTER INSTALLATION. SEAL WITH THERMAL PLASTIC. <br />WALK-IN REFRIGERATION ELECTRICAL DIAGRAM <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES <br />1. ALL ELECTRICAL ROUGH -INS AND CONNECTIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE FIXTURES AND <br />EQUIPMENT PROVIDED BY THE EQUIPMENT VENDOR OR BY OUTSIDE PARTIES LISTED AS 'VENDOR' OR 'BY OTHERS'. ALL <br />INFORMATION PROVIDED ON THESE PLANS ARE TO BE VERIFIED BY THE ELECTRICAL CONTRACTOR THRU THE <br />SPECIFICATIONS MANUAL PROVIDED BY THE EQUIPMENT VENDOR OR BY CONSULTING THE APPROPRIATE OUTSIDE <br />PARTIES. <br />2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING / INSTALLING ALL ELECTRICAL COMPONENTS NECESSARY <br />TO PROVIDE POWER TO EQUIPMENT. ELECTRICAL CONTRACTOR SHALL ALSO COMPLETE ALL INTERNAL WIRING AND <br />FINAL CONNECTIONS TO EQUIPMENT PER MANUFACTURERS SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO: <br />PROVIDING CAPS AND CORDS TO APPLICABLE EQUIPMENT <br />STAINLESS STEEL COVER PLATES WHERE REQUIRED <br />MAIN BREAKER PANELS, CONTROL PANELS, DISCONNECT SWITCHES, STARTERS, ETC. <br />3. ALL ELECTRICAL CONDUIT IS TO BE RUN WITHIN WALL CAVITY AND BOXES AND RECEPTACLES ARE TO BE MOUNTED <br />FLUSH WITH THE WALL SURFACE. SURFACE MOUNTED ELECTRICAL WORK IS NOT TO BE USED UNLESS OTHERWISE <br />SPECIFIED. <br />4. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ENSURING PROPER WORKING CONDITION AND MEETING CURRENT <br />LOCAL CODE REQUIREMENTS FOR ANY / ALL EQUIPMENT LISTED ON THESE PLANS AS 'EXISTING'. <br />5. ALL ELECTRICAL WORK IS TO BE PERFORMED IN FULL ACCORDANCE WITH ALL LOCAL AND FEDERAL CODES AND <br />REQUIREMENTS. <br />6. ALL DIMENSIONS ARE TAKEN FROM FINISHED FLOORS AND FINISHED WALLS OR AS NOTED ON PLAN AND ARE TO <br />CENTERLINE OF ROUGH -INS. <br />7. REFER TO ARCHITECTURAL PLANS AND / OR CONSTRUCTION DOCUMENTS FOR ANY ADDITIONAL ELECTRICAL <br />CONNECTIONS OR OUTLETS REQUIRED TO MEET LOCAL CODES. <br />ELECTRICAL CONTRACTOR TO PROVIDE <br />CONDUIT, JUNCTION BOXES AND <br />ROUGH -INS FOR ALL DATA LINES TO AND <br />FROM COMPUTERS, P.O.S. SYSTEMS AND <br />PRINTERS. VERIFY ELECTRICAL <br />REQUIREMENTS FROM P.O.S. PROVIDER. <br />ELECTRICAL CONTRACTOR TO CONTACT <br />P.O.S. PROVIDER 4 WEEKS PRIOR TO <br />INSTALLATION. <br />ELECTRICAL CONTRACTOR TO PROVIDE <br />EXIT SIGNAGE AND LIGHTING. <br />WALL PLATES <br />COLOR <br />LOCATION <br />S/S <br />KITCHEN <br />BROWN <br />STAINED DINING WALLS <br />WHITE <br />I UNDER SMOOTHIE BAR & WHITE PAINTED WALLS <br />ELECTRICAL LEGEND <br />ABBR. <br />DESCRIPTION <br />SYM. <br />DR <br />DUPLEX RECEPTACLE <br />SR <br />208-240V SINGLE RECEPTACLE <br />QR <br />QUADRUPLEX RECEPTACLE <br />JB <br />JUNCTION BOX <br />SW <br />SWITCH <br />DC <br />DROP CORD <br />EC <br />HARDWIRED ELECTRICAL CONNECTION <br />■ <br />TO <br />TELEPHONE OUTLET <br />D <br />DO <br />DATA OUTLET, CAT5E <br />10. <br />V <br />VOLTAGE <br />A <br />AMPERE <br />W <br />WATTS <br />KW <br />KILOWATTS <br />HP <br />HORSEPOWER <br />AFF <br />ABOVE FINISHED FLOOR <br />A-4 <br />PANEL ' <br />A-6 - . _, A-2 <br />POWER PLAN <br />SCALE: 1 /4" = 1'-O" <br />trM RRual <br />GENERAL NOTES: <br />A. ALL EQUIPMENT SHOWN IS NEW UNLESS OTHERWISE <br />NOTED. <br />on BRKR) <br />(GFI BRKR) A-11 (GFI BRKR) <br />A_a A A-13 <br />(GFI BRKR) �vv l .-I <br />(GFI BRKR) <br />O DRAWING NOTES: <br />1, 3 NO. 10 AND 1 NO, 10 E.G. - 1 /2"C. <br />2. 8 RELAY POWER CONTROL PANEL MOUNTED FLUSH IN WALL. <br />3. ROUTE CIRCUIT VIA POWER/LIGHTING CONTROL PANEL. <br />4. CONTROLLED RECEPTACLE TO HAVE "CONTROLLED" ENGRAVED ON FACEPLATE. <br />5. SEE MECHANICAL SCHEDULE THIS SHEET FOR POWER REQUIREMENTS. <br />6. SEE DRIVE-THRU DETAIL SHEET E4.0 FOR CONDUIT REQUIREMENTS AND SPECIFICATIONS. <br />COORDINATE DEVICE INSTALLATION LOCATIONS WITH OWNER PRIOR TO ROUGH IN. CUT <br />AND PATCH EXISTING SLAB AS NEEDED FOR INSTALLATION. <br />EQUIPMENT SCHEDULE <br />EQUIPMENT ELECTRICAL SCHEDULE <br />NO.QTY <br />EQUIPMENT DESCRIPTION <br />PROVIDER <br />VENDOR <br />INSTALL <br />FIN. CON. <br />VOLTS / <br />PHASE <br />AMPS <br />WATTS <br />HP <br />CONNECT <br />TYPE <br />ROUGH -IN <br />HEIGHT <br />REMARKS <br />1A <br />1 1 <br />WALK-IN COOLER / FREEZER COMBO UNIT <br />IF <br />IEV <br />I EV <br />I EC <br />120V/1 <br />1 10.0 <br />JB <br />108" <br />E.C. TO HARDWIRE AS REQUIRED <br />NOTE: FOR LIGHTING, ALARM CLOCKS, DOOR FRAME HEATERS, PORTS & SILLS. ELECTRICAL <br />CONTRACTOR TO INSTALL & WIRE ALL LIGHT FIXTURES IN WALK-IN <br />COOLER <br />/ FREEZER. <br />16 <br />1 <br />COOLER REFRIGERATION, SELF-CONTAINED <br />F <br />EV <br />EV <br />EC <br />208-23OV/1 <br />11.5 <br />3/4 <br />JB <br />108" <br />SEE SHOP DWGS <br />2 <br />1 <br />FREEZER, 3-DR REACH -IN <br />F <br />EV <br />EV <br />EC <br />120V/1 <br />7.9 <br />1 <br />DR <br />90" <br />NEMA 5-15 <br />9 <br />1 <br />WATER HEATER <br />GC <br />SIPS <br />GC <br />EC/PC <br />SEE MECHANICAL SCHEDULE THIS SHEET <br />*10 <br />LOT <br />SURVEILLANCE SYSTEM <br />F <br />OC <br />V <br />V <br />120V/1 <br />8.0 <br />SHARED QR <br />REMARKS <br />VERIFY REQUIREMENTS; QR MOUNTED 12" FROM CEILING <br />12 <br />1 <br />PRINTER WITH SHELF <br />F <br />JOLT <br />GC <br />GC <br />120V/1 <br />3.1 <br />DR <br />46" <br />NEMA 5-15 <br />**21 <br />2 <br />ICE MAKER W / BIN <br />F <br />EV <br />EV <br />EC/PC <br />208-230V/1 <br />12.2 EA. <br />JB <br />72" <br />E.C. TO HARDWIRE TO TERMINAL AS REQUIRED <br />25 <br />1 <br />MICROWAVE <br />F <br />EV <br />EV <br />- <br />120V/1 <br />13.0 <br />1550 <br />DR <br />54" <br />NEMA 5-15 <br />27 <br />2 <br />MICROWAVE CONVECTION OVEN <br />F <br />EV <br />EV <br />- <br />208-24OV/1 <br />27.4 EA. <br />5700 <br />SR <br />46" <br />NEMA 6-30; WIRE FOR SECOND FUTURE OVEN <br />28 <br />1 <br />REFRIGERATED PREP TABLE, 30 PAN <br />F <br />EV <br />EV <br />- <br />120V/1 <br />12.0 <br />1 /2 <br />DR <br />18" <br />NEMA 5-15 <br />29 <br />1 <br />REFRIGERATED PREP TABLE, 30 PAN <br />F <br />EV <br />EV <br />- <br />120V/1 <br />12.0 <br />1 /2 <br />DR <br />18" <br />NEMA 5-15 <br />30 <br />1 <br />REFRIGERATED PREP TABLE, 18 PAN <br />F <br />EV <br />EV <br />- <br />120V/1 <br />7.2 <br />1 /5 <br />DR <br />18" <br />NEMA 5-15 <br />37 <br />4 <br />BLENDER, BAR TYPE <br />F <br />EV <br />EV <br />- <br />120V/1 <br />15.0 EA. <br />3 PEAK <br />DR <br />46" <br />NEMA 5-15; DEDICATED CIRCUIT <br />45 <br />1 <br />PANINI PRESS <br />F <br />EV <br />EV <br />- <br />120V/1 <br />15.0 <br />DR <br />46" <br />NEMA 5-15 <br />*52A <br />2 <br />POS TERMINAL <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />0.14 EA. <br />SHARED QR <br />24" <br />NEMA 5-15; DEDICATED CIRCUIT; VER REQMNTS. <br />*52B <br />2 <br />POS TERMINAL <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />0.14 EA. <br />SHARED QR <br />46" <br />NEMA 5-15; DEDICATED CIRCUIT; VER REQMNTS. <br />*53 <br />1 <br />POS SYSTEM - BACK OF HOUSE <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />3.0 APPROX. <br />SHARED QR <br />REMARKS <br />VERIFY REQUIREMENTS; QR MOUNTED 12" FROM CEILING <br />*54A <br />3 <br />POS PRINTER <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />0,25 EA. <br />SHARED QR <br />24" <br />NEMA 5-15; DEDICATED CIRCUIT; VER REQMNTS <br />*54B <br />2 <br />POS PRINTER <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />0.25 EA. <br />SHARED QR <br />46" <br />NEMA 5-15; DEDICATED CIRCUIT; VER REQMNTS <br />*55 <br />3 <br />KDS MONITOR <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />0.5 EA. <br />DR <br />67" <br />NEMA 5-15; DEDICATED CIRCUIT; VER REQMNTS <br />57 <br />2 <br />STEAMER <br />F <br />EV <br />EV <br />EC/PC <br />208V/1 <br />15.9 EA. <br />3300 <br />SR <br />46" <br />NEMA 6-20 <br />63 <br />1 <br />UNDERCOUNTER REFRIGERATOR (FUTURE ITEM) <br />F <br />EV <br />EV <br />120V/1 <br />4.5 <br />1 /4 <br />DR <br />18" <br />NEMA 5-15 <br />*64A <br />2 <br />EMV CARD READER <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />1.0 <br />SHARED QR <br />24" <br />NEMA 5-15 <br />*648 <br />1 <br />EMV CARD READER <br />F <br />M <br />RTG <br />RTG <br />120V/1 <br />1'0 <br />SHARED QR <br />46" <br />NEMA 5-15 <br />74B <br />1 <br />SIT-DOWN COUNTER SUPPORT WALL <br />F <br />EV <br />EV <br />- <br />120V/1 <br />15.0 <br />DR <br />32" <br />NEMA 5-15; HORIZONTAL MOUNT <br />79 <br />1 <br />TROPICAL SMOOTHIE NEON SIGN <br />F <br />EV <br />EV <br />- <br />120V/1 <br />3.0 <br />DR <br />REMARKS <br />FEED FROM ABOVE <br />80 <br />1 <br />EXTERIOR SIGNAGE <br />F <br />Sc <br />Sc <br />EC <br />120V/1 <br />VERIFY <br />JB <br />VERIFY <br />G.C. TO VERIFY ORIGINATION OF POWER FOR SIGNAGE <br />A <br />1 <br />CONVENIENCE OUTLET <br />JEC <br />EC <br />EC <br />EC <br />120V/1 <br />15.0 CKT <br />DR <br />46" <br />INEMA 5-15 <br />B <br />LOT <br />USB ENABLED CONVENIENCE OUTLET <br />JEC <br />EC <br />EC <br />EC <br />120V/1 <br />15.0 CKT <br />DR <br />18"1 <br />NEMA 5-15 <br />C <br />LOT <br />I DATA CONDUIT <br />JEC <br />EC <br />EC <br />EC <br />E.C.TO PROVIDE EMPTY CONDUIT & JB FOR DATA AND PHONE LINES. VERIFY LOCATIONS WITH OWNER. SEE HGT'S. ON SHEET TSC-4.0 <br />ABBREVIATION KEY <br />ABBREVIATION KEY <br />ABBR. <br />ABBREVIATION DESCRIPTION <br />ABBR. <br />ABBREVIATION DESCRIPTION <br />F <br />FRANCHISEE <br />V <br />VENDOR <br />EV <br />EQUIPMENT VENDOR <br />M <br />MICROS <br />GC <br />GENERAL CONTRACTOR <br />RTG <br />RETAIL TECHNOLOGY GROUP <br />EC <br />ELECTRICAL CONTRACTOR <br />UMI <br />ULTERIOR MOTIVES INTERNATIONAL <br />CC <br />CONTRACTOR'S CHOICE <br />HL <br />HERMITAGE LIGHTING <br />OC <br />OWNER'S CHOICE <br />MMM <br />MUZAK (MOOD MEDIA) <br />LJ <br />LOCAL JURISDICTION <br />UC <br />UTILITY COMPANY <br />SC <br />SIGN COMPANY <br />INSTALL <br />EQUIPMENT INSTALLER <br />VLL <br />VERIFY WITH LANDLORD <br />FIN.CON. <br />FINAL CONNECTIONS <br />" ALL DEDICATED CIRCUITS TO HAVE ORANGE RECEPTACLES. <br />BOH POS SYSTEM TO HAVE ITS OWN DEDICATED CIRCUIT. <br />POS TERMINALS, PRINTERS AND KIDS MONITORS MAY SHARE ONE DEDICATED CIRCUIT. <br />" 2ND CONNECTION FOR FUTURE USE. <br />MECHANICAL <br />EQUIPMENT <br />DESCRIPTION <br />ELECTRICAL CHARACTERISTICS <br />CIRCUIT <br />DESIGNATION <br />BREAKER <br />FEEDER <br />EQUIP. <br />GROUND <br />CONDUIT <br />DISCONNECT SWITCH <br />REMARKS <br />VOLTS <br />PHASE <br />I KW <br />HP <br />MCA <br />AMPS <br />POLES <br />RTU-1 <br />208 <br />3 <br />54.6 <br />A-1,3,5 <br />60 <br />3 <br />3 #6 <br />#10 <br />1" <br />60A/3P/F/NEMA-3R <br />NOTE#1 <br />EF-1 <br />120 <br />1 <br />0.08 <br />NOTE #2 <br />(2) #12 <br />#12 <br />1/2" <br />TOGGLE SWITCH <br />WH-1 <br />1 208 <br />1 <br />2.5 <br />B-810 <br />1 20 <br />2 <br />(2)#12 <br />1 #12 <br />1 1/2" <br />30A/2P/NF/NEMA-1 <br />NOTES: <br />1. FUSE DISCONNECT PER UNIT NAMEPLATE MFS OR MOCP. <br />2. CONNECT TO SWITCHED LEG OF ROOM LIGHTING CIRCUIT. <br />SPEAKER POST <br />FOR DRIVE-THRU <br />MENU BOARD. <br />• <br />o•, <br />s <br />s <br />VJ <br />• <br />e <br />U' <br />i <br />• <br />• <br />i <br />• <br />a <br />• <br />L• <br />• <br />• <br />• <br />• <br />• <br />>% • <br />• <br />• <br />13 0 <br />0 0 <br />Li <br />• <br />• <br />CL • <br />• <br />• <br />• <br />• <br />• <br />�E <br />cM O <br />10 <br />U <br />o41-v <br />¢co <br />O v <br />Z g <br />+� z Q E� <br />V < U <br />o g <br />_ o 2 <br />Lu <br />W U) <br />= n <br />ul <br />W <br />•��Lu <br />CA }, <br />UJ <br />� wa <br />wN <br />do <br />T r <br />T <br />,•� �Nd..82'9 >>, <br />Q: 387 :' = <br />uj m <br />U TAT OF! <br />"o. <br />• • •j <br />7898 GALL BLVD., <br />ZEPHYRHILLS, FL 32541 <br />STORE #FL-280 <br />©A` E <br />SHEET m0 <br />E3mO <br />AA-0003276 <br />QjrOPrRrrHT <br />PURDY+MUROPFARCHITECTURE, INC. <br />ALL RIrHT6 RESERVED <br />
The URL can be used to link to this page
Your browser does not support the video tag.