PLUMBING ACCESSORY SCHEDULE
<br />MARK
<br />FIXTURE
<br />DESCRIPTION
<br />MANUFACTURERS
<br />CO-1
<br />FLOOR
<br />FLOOR CLEANOUT:
<br />ZURN
<br />CLEANOUT
<br />DURA—COATED CAST IRON BODY,
<br />NO. ZN-1400—VP
<br />WITH SQUARE POLISHED NICKEL
<br />BRONZE SCORIATED TOP,
<br />ADJUSTABLE GAS AND WATERTIGHT
<br />ABS TAPERED THREAD PLUG
<br />CO-2
<br />EXTERIOR
<br />EXTERIOR CLEANOUT:
<br />ZURN
<br />CLEANOUT
<br />HEAVY DUTY DURA—COATED CAST
<br />NO. Z-1400—HD
<br />IRON BODY WITH ROUND CAST IRON
<br />WADE
<br />SCORIATED TOP, ADJUSTABLE GAS
<br />NO. 6030—X
<br />AND WATER TIGHT ABS TAPERED
<br />J. R. SMITH
<br />THREADED PLUG
<br />NO. 4231
<br />FD-1
<br />FLOOR DRAIN
<br />FLOOR DRAIN:
<br />ZURN
<br />6" ROUND TYPE "B" STRAINER, DUCO
<br />NO. ZN-415—P
<br />CAST IRON BODY, FLASHING, COLLAR,
<br />NICKEL BRONZE ADJUSTABLE STRAINER,
<br />PROVIDE DEEP SEAL TRAP WITH
<br />PRIMER CONNECTION
<br />HB-1
<br />HOSE BIBB
<br />HOSE BIBB:
<br />CHICAGO
<br />OUTSIDE SILL FAUCET, VACUUM
<br />NO. 387—RCF—E27
<br />BREAKER, 3/4" HOSE OUTLET, LOCK
<br />T&S BRASS
<br />SHEILD CAP, REMOVABLE T—HANDLE
<br />NO. B-0737—RGH
<br />3/4" FLANGED FEMALE INLET
<br />ROIUGH CHROME FINISH AND BRAIN
<br />FS-1
<br />FLOOR SINK
<br />FLOOR SINK:
<br />ZURN
<br />PVC BODY 14" FLOOR SINK WITH SCHD
<br />FD-2280—PB—R6-P
<br />40 HUB CONNECTION, 12" ROUND TOP
<br />BRASS GRATE, SECONDARY STRAINER,
<br />AND TRAP PRIMER CONNECTION.
<br />NOT USED
<br />AAV-1
<br />AIR ADMITTANCE
<br />---
<br />STUDOR
<br />VALVE
<br />MAXI —VENT
<br />RPZ-1
<br />REDUCED
<br />REDUCED PRESSURE PRINCIPLE
<br />ZURN — WILKINS
<br />PRESSURE
<br />ASSEMBLY:
<br />975XL
<br />PRINICIPLE
<br />CAST BRONZE ASTM B 584 MAIN
<br />ASSEMBLY
<br />VALVE AND ACCESS COVERS
<br />P-1
<br />HW RECIRC
<br />HOT WATER RECIRCULATION PUMP:
<br />BELL & GOSSETT
<br />PUMP
<br />MAINTENANCE FREE, IN —LINE, LEAD
<br />NO. NBF-12FAW
<br />FREE BRONZE, WET ROTOR CIRCULATOR,
<br />1 GPM, 11 FT HD, 3/4" FLANGES, 55
<br />WATTS, 120/1/60, 2800 RPM, WITH
<br />AQUASTAT
<br />AQUASTAT TEMP. RANGE AND TIMER
<br />I A19DAC-1 C
<br />HAMMER
<br />ARRESTOR
<br />SCHEDULE
<br />ZURN SHOKTROL
<br />Z-1700 SERIES
<br />SIZE 100
<br />SIZE 200
<br />SIZE 300
<br />SIZE 400
<br />SIZE 500
<br />SIZE 600
<br />P.D.I. SYMBOLS*
<br />A
<br />B
<br />C
<br />D
<br />E
<br />F
<br />FIXTURE —UNIT
<br />RATING
<br />1-11
<br />12-32
<br />33-60
<br />61-113
<br />114-154
<br />155-330
<br />*CLASSIFICATIONS ESTABLISHED BY THE PLUMBING AND DRAINAGE INSTITUTE
<br />"STANDARD P.D.I.—WH2O1". APPROVED EQUALS SHALL BE J.R. SMITH & WADE.
<br />1 1 /4"
<br />TAILPIECE
<br />O.D. TUBING
<br />SLIP JOINT
<br />PROVIDE WALL BEND WALL
<br />LENGTH AS REQUIRED �
<br />CHROME PLATED
<br />ESCUTCHEON—"
<br />SLIDE JOINT
<br />1
<br />PLUMBING FIXTURE AND CONNECTION SCHEDULE
<br />TAG
<br />FIXTURE
<br />DESCRIPTION
<br />MOUNTING
<br />HEIGHT
<br />MIN. CONNECTIONS
<br />SPECIFICATION
<br />NOTES
<br />WASTE
<br />CW
<br />HW
<br />MANUFACTURER
<br />FIXTURE
<br />TRIM
<br />WASTE
<br />TRAP
<br />SUPPLY
<br />WC-1
<br />WATER CLOSET
<br />FLOOR MOUNTED
<br />FLUSH TANK
<br />1.28 GAL/FLUSH
<br />FLOOR
<br />TO RIM
<br />16 1/2"
<br />4"
<br />1/2"
<br />---
<br />KOHLER
<br />K-3713
<br />---
<br />---
<br />---
<br />K-7637
<br />SEAT — OLSONITE 95 OR EQUAL BY BENEKE OR BEMIS
<br />PROVIDE FLUSH HANDLE ON LAV SIDE OF TANK
<br />ELJER
<br />EQUAL
<br />---
<br />---
<br />---
<br />EQUAL
<br />AMER—STAN
<br />EQUAL
<br />---
<br />---
<br />---
<br />EQUAL
<br />UR-1
<br />URINAL
<br />WALL HUNG
<br />FLUSH VALVE
<br />0.5 GAL/FLUSH
<br />FLOOR
<br />TO RIM
<br />17"
<br />2"
<br />3/4"
<br />---
<br />KOHLER
<br />K-4989—T-0
<br />---
<br />---
<br />---
<br />---
<br />PROVIDE FLOOR MOUNTED CARRIER BY JOSAM, WADE,
<br />OR ZURN IF MOUNTED ON STUD WALL
<br />ELJER
<br />EQUAL
<br />---
<br />---
<br />---
<br />---
<br />SLOAN ROYAL
<br />---
<br />---
<br />---
<br />---
<br />186-0.5
<br />LAV-1
<br />LAVATORY
<br />COUNTERTOP
<br />20"X17" OVAL
<br />COUNTER
<br />TOP
<br />1 1 /4"
<br />1/2'
<br />1/2"
<br />KOHLER
<br />K-2196-4
<br />---
<br />K-7715
<br />K-9000
<br />K-7606
<br />AMER—STAN
<br />EQUAL
<br />---
<br />803-0552
<br />804-1180
<br />802-0320
<br />CHICAGO FAUCETS
<br />---
<br />2200-4
<br />327
<br />---
<br />1nnR
<br />LAV-2
<br />LAVATORY
<br />WALL HUNG
<br />21 "X18"
<br />4" CENTER HOLES
<br />FLOOR
<br />TO BOT
<br />OF APRON
<br />MIN. 29"
<br />1 1/4"
<br />1/2"
<br />1/2"
<br />KOHLER
<br />K-2005
<br />---
<br />K-7715
<br />K-9000
<br />K-7606
<br />PROVIDE FLOOR MOUNTED CARRIER BY JOSAM, WADE,
<br />OR ZURN IF MOUNTED ON STUD WALL
<br />PROVIDE PREMOLDED PREINSULATED COVER FOR TRAP & SUPPLIES
<br />PROVIDE DRAIN OFFSET TO PROVIDE HANDICAP CLEARANCE
<br />ELJER
<br />EQUAL
<br />---
<br />803-0552
<br />804-1180
<br />802-0320
<br />CHICAGO FAUCETS
<br />---
<br />2200-4
<br />327
<br />---
<br />1008
<br />S-1
<br />STAINLESS STEEL
<br />SINK 19"X18"X5.5"
<br />DEEP SINGLE COMP
<br />COUNTER
<br />TOP
<br />1 1/2"
<br />1/2"
<br />1/2"
<br />ELKAY
<br />LR-1918552
<br />---
<br />---
<br />---
<br />---
<br />PROVIDE 1 1/2- CAST BRASS P—TRAP AND 3/8" SUPPLY STOPS.
<br />PROVIDE DRAIN OFFSET AT HANDICAP LOCATIONS
<br />JUST
<br />EQUAL
<br />---
<br />---
<br />---
<br />---
<br />CHICAGO FAUCETS
<br />---
<br />2302
<br />---
<br />---
<br />---
<br />S-2
<br />STAINLESS STEEL
<br />SINK 33"X21"X5.5"
<br />DEEP TWO COMP
<br />COUNTER
<br />TOP
<br />1 1/2"
<br />1/2"
<br />1/2"
<br />ELKAY
<br />LR-3321553
<br />---
<br />LK-35
<br />---
<br />---
<br />PROVIDE 1 1/2" CAST BRASS P—TRAP AND 3/8" SUPPLY STOPS.
<br />PROVIDE DRAIN OFFSET AT HANDICAP LOCATIONS
<br />PROVIDE PREMOLDED PREINSULATED COVER FOR TRAP & SUPPLIES
<br />PROVIDE DRAIN OFFSET TO PROVIDE HANDICAP CLEARANCE
<br />JUST
<br />EQUAL
<br />---
<br />J-35
<br />___
<br />___
<br />CHICAGO FAUCETS
<br />---
<br />2300—BCP
<br />---
<br />---
<br />---
<br />DF-1
<br />ELECTRIC WATER
<br />COOLER — WALL
<br />HUNG — BI—LEVEL
<br />FLOOR TO
<br />RIM OF
<br />HIGH UNIT
<br />40"
<br />1 1 /4"
<br />1 /2"
<br />---
<br />HALSEY-TAYLOR
<br />HVR8BL—ADA
<br />___
<br />___
<br />---
<br />---
<br />PROVIDE WITH STAINLESS STEEL PANELS
<br />PROVIDE 1 1/4" P—TRAPS AND 3/8" SUPPLY STOP
<br />OASIS
<br />EQUAL
<br />---
<br />---
<br />---
<br />---
<br />ELKAY
<br />EQUAL
<br />MS-1
<br />MOP SINK
<br />FLOOR MOUNTED
<br />24"x24"x12"
<br />FLOOR
<br />MOUNTED
<br />»
<br />3
<br />1/2
<br />1/2 "
<br />STERN—WILLIAMS
<br />HVR8BL—ADA
<br />SB-800
<br />---
<br />---
<br />---
<br />MOUNT TRIM 3 —0 ABOVE FINISHED FLOOR AND PROVIDE 4 —0 "
<br />HOSE AND HOSE HOOK.
<br />1
<br />FIAT
<br />EQUAL
<br />TSB-200
<br />---
<br />---
<br />---
<br />CHICAGO FAUCETS
<br />EQUAL
<br />---
<br />956
<br />---
<br />___
<br />WH-1
<br />ELECTRIC WATER
<br />HEATER 30 GAL.
<br />STORAGE CAPACITY
<br />AS HIGH
<br />AS POSS.
<br />ABV. MS—
<br />---
<br />3/4"
<br />3/4"
<br />LOCHINVAR
<br />ESA030KK
<br />---
<br />---
<br />---
<br />---
<br />PROVIDE WIT 4.5KW 240V-1PH-60HZ HEATING ELEMENTS. SEE
<br />PIPING DIAGR M.
<br />A.O.SMITH
<br />ELJF-30
<br />---
<br />---
<br />---
<br />RHEEM
<br />EQUAL
<br />---
<br />---
<br />---
<br />---
<br />WH-2
<br />INSTANTANEOUS
<br />ELECTRIC WATER
<br />HEATER
<br />BELOW
<br />SINK
<br />CABINET
<br />---
<br />1/2"
<br />1/2"
<br />CHRONOMITE
<br />S-30L
<br />PROVIDE WITH 3.0 KW-240V-1 PH HEATING ELEMENT AND
<br />BALL VALVE IN CW INLET
<br />PSH-1
<br />p00L SHOWER
<br />WITH HOSE BIBB
<br />---
<br />---
<br />1/2"
<br />---
<br />THE POOL SHOWER
<br />NO. PS1000ADA
<br />FLOOR MOUNTED SHOWER, ADA COMPLIANT VALVES, WITH HOSE
<br />BIBB AND VACUUM BREAKER. SHOWER HEAD DRAIN VALVE AND
<br />ASME T&P BASE.
<br />* NOTE: PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE AT ALL LAVATORIES AND SINKS.
<br />—P—TRAP
<br />NOTES:
<br />1. THE ENTIRE P—TRAP ASSEMBLY, INCLUDING SLIP JOINT NUTS, SHALL BE 17
<br />GAUGE, HEAVY CAST BRASS WITH A POLISHED CHROME PLATED FINISH.
<br />(McGUIRE #8902 1 1 /4" x 1 1/2"-17 GA. OR APPROVED EQUAL)
<br />2. FOR BARRIER FREE LAVATORIES, INSTALL 1 1 /4" OFFSET TAILPIECE.
<br />(McGUIRE #155WC OR APPROVED EQUAL)
<br />' P' —TRAP DETAIL
<br />NO SCALE
<br />I Z
<br />r
<br />N
<br />r
<br />4"
<br />molimm r
<br />ROOF DECK
<br />TRAP PRIMER SHALL BE ZURN MODEL
<br />NO. 1022—CP OR APPROVED EQUAL Q
<br />(TRAP PRIMER SHALL BE CONNECTED TO A MAIN OR BRANCH
<br />PIPE WHICH WILL GUARANTEE A 10 PSI DELTA PRESSURE
<br />z
<br />FLOOR DRAIN, SQUARE
<br />to
<br />OR ROUND AS INDICATED
<br />z
<br />N a
<br />,• e
<br />p d p S
<br />UNION
<br />TRAP PRIMER PIPING SHALL BE SEAMLESS
<br />COPPER TUBING WITHOUT FITTINGS
<br />TRAP PRIMER CONNECTION DETAIL
<br />NO SCALE
<br />COPPER OR LEAD
<br />SLEEVE WITH FLANGE
<br />VENT PIPE
<br />F MASTIC
<br />ROOF DECK
<br />PACK WITH OAKUM OR
<br />EQUAL MATERIAL TO
<br />PREVENT ASPHALT DRAINAGE
<br />VENT THRU ROOF DETAIL
<br />NO SCALE
<br />el-rM A I L I rM
<br />FINISHED FLOOR
<br />Me
<br />LOPE MIN.
<br />EPDXY GROUT
<br />:RETE 9235
<br />:RPROOF MEMBRANE
<br />I COLLAR
<br />FLOOR DRAIN DETAIL
<br />NO SCALE
<br />EMERALD
<br />ENGINEERING INC.
<br />9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619
<br />TEL (813) 995-0300 FLORIDA EB* 0027845
<br />WWW.EMERALDMEP.COM EEI PROJECT# 180822
<br />PLUMBING CODE CRITERIA
<br />THE FOLLOWING IS A LIST OF ALL CODES ADOPTED DECEMBER 31, 2017 BY THE STATE FIRE
<br />MARSHALL'S RULE 69A3.012 F.A.C.:
<br />* FLORIDA BUILDING CODE 6TH EDITION (2017) — ALL SECTIONS
<br />* FLORIDA ENERGY EFFICIENCY CODE (FBC 2017), FLORIDA ENERGY CODE SOFTWARE:
<br />ENERGYGAUGE USA VERSION 6.00
<br />* FLORIDA FIRE PREVENTION CODE 6TH EDITION (2017)
<br />69A-3.012 STANDARDS OF THE NATIONAL FIRE PROTECTION ASSOCIATION ADOPTED.
<br />(1). EXCEPT AS SPECIFICALLY MODIFIED BY STATUTE OR BY THE STATE FIRE MARSHAL'S
<br />RULES, THE "FLORIDA FIRE PREVENTION CODE, 6TH EDITION (2017)," WHICH IS COMPRISED
<br />OF THE FLORIDA SPECIFIC EDITION OF NFPA 101, THE LIFE SAFETY CODE (2015 EDITION)
<br />AND THE FLORIDA SPECIFIC EDITION OF NFPA 1, THE FIRE CODE (2015 EDITION), ARE
<br />HEREBY ADOPTED AND INCORPORATED BY REFERENCE AND ARE APPLICABLE TO THOSE
<br />BUILDINGS AND STRUCTURES SPECIFIED IN PARAGRAPHS (A) AND (B) OF SUBSECTION (1)
<br />OF SECTION 633.206, F.S. IN ADDITION, THE FOLLOWING STANDARDS, EXCEPT AS
<br />SPECIFICALLY MODIFIED IN THE RULE CHAPTERS IN RULE TITLE 69A, ARE HEREBY ADOPTED
<br />AND INCORPORATED BY REFERENCE AND SHALL TAKE EFFECT ON THE EFFECTIVE DATE OF
<br />THIS RULE, AS APART OF THE UNIFORM FIRE SAFETY STANDARDS ADOPTED BY RULE BY
<br />THE STATE FIRE MARSHAL AND ARE APPLICABLE TO THOSE BUILDINGS AND STRUCTURES
<br />SPECIFIED IN PARAGRAPHS (A) AND (B) OF SUBSECTION (1) OF SECTION 633.206, F.S.:
<br />* NFPA 70, 2014 EDITION, NATIONAL ELECTRIC CODE
<br />OTHER:
<br />* LOCAL CODES AND ORDINANCES
<br />NOTE: TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLUMBING DESIGN DRAWINGS
<br />COMPLY WITH THE ABOVE CODE CRITERIA. WHEN TWO OR MORE CODES OR
<br />STANDARDS ARE IN CONFLICT, THE MORE STRINGENT SHALL APPLY.
<br />PLUMBING SYMBOL LEGEND
<br />DESCRIPTION
<br />ABBREV.
<br />SYMBOL
<br />SANITARY PIPING
<br />SAN
<br />VENT PIPING
<br />V
<br />------------
<br />1
<br />STORM PIPING
<br />ST
<br />COLD WATER PIPING
<br />CW
<br />- - -
<br />HOT WATER PIPING
<br />HW
<br />----------
<br />HOT WATER RETURN PIPING
<br />HWR
<br />-------
<br />VENT THRU ROOF
<br />VTR
<br />CLEAN OUT
<br />CO
<br />PIPING UP/DN
<br />AIR ADMITTANCE VALVE
<br />AAV
<br />PLUMBING GENERAL NOTES
<br />NO EXCLUSIONS FROM OR LIMITATIONS IN THE LANGUAGE USED IN THE CONTRACT
<br />DOCUMENTS SHALL BE INTERPRETED AS MEANING THAT THE EQUIPMENT, APPURTENANCES,
<br />AND/OR ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM ARE NOT
<br />TO BE PROVIDED AS REQUIRED. THE SEPARATE DIVISIONAL CONTRACT DOCUMENTS DO NOT
<br />RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE THE WORK WHICH .IS
<br />INDICATED ON ANY OF THE DIVISIONAL CONTRACT DOCUMENTS. REVIEW AND COORDINATE
<br />THE SCOPE OF WORK WITH ALL DOCUMENTS AND TRADES TO ASSURE A COMPLETE AND
<br />FUNCTIONAL SYSTEM IS BID AND INSTALLED.
<br />THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS
<br />REQUIRED TO COMMENCE AND COMPLETE PLUMBING WORK.
<br />SUBMIT FULL SUBMITTALS OF ALL PLUMBING EQUIPMENT AND MATERIALS TO THE ENGINEER
<br />FOR REVIEW, WHETHER IT IS EXACTLY AS SPECIFIED OR NOT.
<br />THE CONTRACT DOCUMENTS AND SUBMITTALS OF ALL TRADES SHALL BE COORDINATED AND
<br />BE VIEWED IN CONNECTION AND CONJUNCTION WITH EACH OTHER TO INSURE THE PROPER
<br />LOCATION AND INSTALLATION OF ALL DEVICES AND EQUIPMENT. MAKE PARTICULAR NOTE
<br />OF LOCATIONS AND DIMENSIONS SHOWN ON THE ARCHITECTURAL FLOOR PLANS AND
<br />ELEVATIONS.
<br />PLUMBING DRAWINGS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE PLUMBING
<br />SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL LOCATION
<br />OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR IN
<br />COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF MANUFACTURER'S
<br />SUBMITTALS, AND SIMILAR CERTIFIED DATA.
<br />ALL EXTERIOR EXPOSED MATERIALS SHALL BE CONSTRUCTED OF NON—FERROUS MATERIALS
<br />AND BE PAINTED WITH TWO COATS OF RUST INHIBITOR PAINT.
<br />INSTALL AND TEST ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH THE
<br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. MAINTAIN ADEQUATE SERVICE
<br />SPACE AS REQUIRED. SERVICE SPACE SHALL BE CLEAR OF DUCTS, PIPES, CONDUITS, WALL
<br />STUDS, CEILING HANGERS, AND ANY OTHER CONSTRUCTION APPURTENANCE.
<br />CONTRACTOR SHALL COORDINATE AND PROVIDE ALL CEILING/FLOOR/WALL ACCESS PANELS
<br />THAT MAY BE REQUIRED FOR THE INSTALLATION, INSPECTION, AND SERVICE OF PLUMBING
<br />EQUIPMENT WHETHER OR NOT IT IS SHOWN. ACCESS PANELS TO BE SELECTED BY THE
<br />AT PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A MINIMUM OF 2 HOURS OF
<br />TRAINING ON THE OPERATION AND MAINTENANCE OF THE PLUMBING EQUIPMENT.
<br />CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY ON PARTS AND LABOR FROM THE
<br />DATE OF SUBSTANTIAL COMPLETION.
<br />ABOVE GROUND DOMESTIC WATER PIPING SHALL BE CPVC WITH GLUED FITTINGS
<br />EXCEPT AT WATER HEATER(S). HOT AND COLD WATER WITHIN 10'-0" OF THE
<br />WATER HEATER(S) SHALL BE TYPE 'L' COPPER.
<br />BELOW GRADE DOMESTIC WATER PIPING SHALL BE COPPER L TYPE WITHOUT
<br />SOLDERED FITTINGS AND JOINTS.
<br />INSULATE ALL HOT WATER AND RETURN PIPING WITH 1" THICK HIGH DENSITY
<br />FIBERGLASS INSULATION WITH FACTORY APPLIED VAPOR BARRIER ALL SERVICE JACKET.
<br />ALL SOIL, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC.
<br />ALL HORIZONTAL SOIL AND WASTE PIPING 2 1/2" IN DIAMETER AND LESS SHALL
<br />HAVE A SLOPE OF 1 /4" PER ONE FOOT LENGTH OF PIPE. ALL PIPING 3" IN
<br />DIAMETER AND LARGER SHALL HAVE A SLOPE OF 1/8" PER ONE FOOT LENGTH
<br />OF PIPE.
<br />PROVIDE CHROME PLATED STOPS AND SUPPLIES AT ALL WATER CLOSETS AND
<br />LAVATORIES.
<br />PROVIDE COMMERCIALLY MANUFACTURED CAST IRON TO PVC PIPE CONNECTORS
<br />AS REQUIRED.
<br />CHROME PLATED ESCUTCHEONS AND NIPPLES ARE REQUIRED AT ALL FLOOR AND
<br />WALL PENETRATIONS.
<br />ALL FIXTURES AND EQUIPMENT SHALL HAVE SHUT—OFF VALVES AT OR NEAR
<br />EQUIPMENT.
<br />PROVIDE & INSTALL HAMMER ARRESTORS AT FIXTURE GROUPS. INSTALL AIR
<br />CHAMBERS AT INDIVIDUAL FIXTURES.
<br />THE CONTRATOR SHALL CLEAN/POLISH TOPS OF ALL FLOOR DRAINS AND CLEANOUTS.
<br />CONCRETE, DIRT AND TAPE SHALL BE COMPLETELY REMOVED OR THE TOPS SHALL BE
<br />REPLACED.
<br />ALL WATER PIPING SHALL BE SUPPORTED RIGIDLY AND IN LINE FROM BUILDING
<br />STRUCTURE. OFFSET PIPING TO AVOID STRUCTURAL MEMBERS, CANTS, FLASHING,
<br />MECHANICAL AND ELECTRICAL EQUIPMENT, ETC.
<br />PROVIDE ALL CUTTING REQUIRED FOR THE INSTALLATION OF PLUMBING WORK.
<br />FINISH PATCHING SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR.
<br />`®`e's,'®ra`
<br />%°v p. t®S d�
<br />No. 143
<br />; cc
<br />® e F • 40
<br />oo
<br />MICI• x Ulm9� 6TtiLO, PE
<br />FL. REG. NO. PE81436
<br />z
<br />O
<br />D
<br />w
<br />X
<br />■
<br />m
<br />N
<br />cz
<br />(j)
<br />0-
<br />(1)
<br />c�
<br />1�9
<br />0
<br />ca
<br />>
<br />mi
<br />m
<br />_0
<br />L
<br />:3
<br />W
<br />'i
<br />O
<br />:lot
<br />cp
<br />N
<br />L.L
<br />Y
<br />CL
<br />Q
<br />Q
<br />N
<br />N
<br />N
<br />BSB
<br />oEsiiM
<br />www.bsbdesign.com
<br />100 Main St. Suite 209
<br />Safety Harbor, Florida 34695
<br />813 265 4808
<br />JOB NO: AM180320.00 PROJ MGR: MC
<br />DRAWN: CQ CHECKED: MC
<br />PLUMBING GENERAL INFORMATION
<br />Pi A