Laserfiche WebLink
r <br />GENERAL NOTES: <br />ALL WORK SHALL CONFORM TO THE CURRENT EDITION OF THE <br />FLORIDA BUILDING CODES, AND ALL OTHER GOVERNMENTAL <br />OR REGULATORY AUTHORITIES. <br />GENERAL CONTRACTOR AND ALL SUBCONTRACTORS TO <br />VERIFY ALL DIMENSIONS IN THE FIELD. ANY DISCREPANCIES <br />SHALL BE REPORTED TO THE ARCHITECT PRIOR TO <br />PROCEEDING WITH THE WORK. DO NOT SCALE PLANS. <br />THE CONTRACTORS SHALL BE RESPONSIBLE FOR <br />FAMILIARIZING THEM5ELVE5 WITH THE INTENT OF THE <br />DRAWINGS, CONTRACTOR AGREES THAT HE SHALL BE HELD <br />RESPONSIBLE FOR HAVING EXAMINED THE SITE. THE <br />LOCATION OF ALL PROPOSED WORK AND FOR HAVING <br />SATISFIED HIMSELF, AS TO THE CHARACTER AND THE NATURE <br />OF THE EXISTING CONDITIONS AND WORK TO BE PERFORMEDt <br />ALONG WITH THE LOCATION OF EXISTING UTILITIES AND ANY <br />OTHER OBSTRUCTIONS. <br />IT SHALL BE THE RESPONSIBILITY OF ALL SUBCONTRACTORS <br />TO HAVE EXAMINED AND REVIEWED THE COMPLETE SET OF <br />WORKING DRAWINGS AND/OR SPECIFICATIONS TO PROVIDE <br />ALL LABOR AND MATERIALS FOR THEIR RESPECTIVE AREA <br />OF WORK, FOR THE COMPLETE AND FINISHED INSTALLATION IN <br />COMPLIANCE WITH THE INTENT OF THE DRAWINGS AND/OR <br />SPECIFICATIONS WHETHER IT 15 INDICATED OR NOT. ALL WORK, <br />WHETHER INDICATED OR NOT, SHALL BE IN COMPLIANCE WITH <br />ALL BUILDING CODES AND ORDINANCES WHICH ARE <br />APPLICABLE TO THE PROJECT. <br />CONTRACTOR TO PROVIDE ALL BARRICADES, SCAFFOLDING, <br />SIGNS, LIGHTING AND OTHER MEANS OF PROTECTION AS <br />REQUIRED TO COMPLY WITH ALL STATE LAWS AND LOCAL <br />ORDINANCES TO SAFEGUARD PROPERTY AND PERSONS. <br />055TRUCTION5 SHALL BE PLACED SO AS NOT TO DIMINISH <br />THE LIFE SAFETY REQUIREMENTS. <br />ALL WORK SHALL BE PERFORMED BY QUALIFIED <br />CONTRACTORS IN STRICT ACCORDANCE WITH MANUFACTURERS <br />SPECIFICATIONS AND RECOMMENDATIONS. <br />ALL MATERIAL AND EQUIPMENT SHALL BE NEW, STORED AND <br />INSTALLED IN A WORKMANLIKE MANNER STANDARD TO THE <br />TRADE AND THE AMERICAN SOCIETY OF TESTING MATERIALS. <br />THE DESIGN INFORMATION INDICATED ON THE PLANS ARE <br />INDICATED TO BE A COMPLETE AND WORKABLE SYSTEM IN <br />ACCORDANCE WITH ALL PRODUCT MANUFACTURER'S <br />SPECIFICATION, EXISTING AND/OR PROPOSED BUILDING <br />DESIGN, FIELD CONDITIONS, ETC. ALL MISCELLANEOUS <br />MATERIALS, PARTS, DESIGN DIMENSIONS, WHETHER INDICATED <br />ON THE PLANS OR NOT, SHALL BE INCLUDED AS PART OF <br />TH15 DRAWING PACKAGE. <br />THE GENERAL CONTRACTOR OR SUBCONTRACTORS SHALL BE <br />HELD RESPONSIBLE FOR THE REMOVAL AND THE PROPER <br />DISPOSAL OF MATERIALS AND ITEMS REFERRED TO AS <br />"DEBRIS" OR DETERMINED BY THE OWNER OR ARCHITECT TO <br />BE REFUSED. <br />THE GENERAL CONTRACTOR SHALL HAVE MADE ALL <br />REQUIRED PROVISIONS FOR THE REMOVAL OF THE DEBRIS ON <br />SITE. <br />GENERAL CONTRACTOR SHALL TAKE ORDINARY <br />PRECAUTIONS TO SECURE AND PROTECT MATERIALS. <br />ALL WOOD MEMBERS IN CONTACT WITH MASONRY SHALL BE <br />PRE55URE TREATED. <br />ALL METAL USED FOR CONNECTING WOOD MEMBERS TO BE <br />GALVANIZED OR CORROSION RESISTANT. <br />THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY <br />DEVIATION FROM THESE DRAWINGS. <br />SPECIFIC SECTIONS, DETAILS AND STANDARD DETAILS ARE <br />INDICATED ON THE DW'GS AT LOCATIONS WHERE THEY OCCUR, <br />OR AT CHARACTERISTIC LOCATIONS. THEY APPLY, UON, TO <br />OTHER LOCATIONS WHERE IMPLIED BY SIMILARITY OF <br />CONSTRUCTION. <br />CONTRACTOR TO COORDINATE SPACE REQUIREMENTS AND <br />INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WHICH <br />ARE INDICATED DIAGRAMMATICALLY ON THE DRAWINGS. <br />FOLLOW ROUTING SHOWN FOR PIPES, DUCTS, AND CONDUIT AS <br />CLOSELY AS PRACTICABLE. PLACE RUNS PARALLEL WITH <br />LINE OF BLDG. UTILIZE SPACES EFFICIENTLY TO MAXIMIZE <br />ACCESSIBILITY FOR OTHER INSTALLATIONS AND FOR <br />MAINTENANCE AND REPAIRS. <br />IN FINISHED AREAS, UON, CONCEAL PIPES, DUCTS, AND WIRING <br />WITHIN THE CONSTRUCTION. COORDINATE LOCATIONS OF <br />FIXTURES AND OUTLETS WITH FINISH ELEMENTS. <br />TRANSPORT AND HANDLE PRODUCTS IN ACCORDANCE W/ MFR <br />INSTRUCTIONS. <br />PROMPTLY INSPECT SHIPMENTS TO A55URE THAT PRODUCTS <br />COMPLY W/ REQUIREMENTS, QUANTITIES ARE CORRECT, AND <br />PRODUCTS ARE UNDAMAGED. <br />SHOULD MFR INSTRUCTIONS CONFLICT W/ THE DWG5, REQUEST <br />CLARIFICATION FROM ARCHITECT/ENGINEER BEFORE <br />PROCEEDING. <br />ALL THRESHOLDS SHALL COMPLY WITH FLORIDA <br />ACCESSIBILITY CODE, 404.2.5 AS FOLLOWS: <br />A. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 1/2" <br />B. EXISTING OR ALTERED THRESHOLDS 3/4" MAX WITH A <br />BEVELED EDGE ON EACH SIDE 4 A SLOPE NO STEEPER THAN <br />1:2 SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.5 <br />G.G. SHALL FURNISH AND INSTALL CONT. WOOD BLOCK'G IN <br />STUD PARTITIONS FOR ANCHORAGE OF WALL ATTACHED ITEMS, <br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING: GRAB BARS, <br />TOILET ACCESSORIES, HANDRAIL BRACKETS, WALL CABINETS, <br />WALL -MOUNTED FIXTURES ETC. <br />THE OWNER SHALL BE RESPONSIBLE FOR PROVIDING THE <br />CONTRACTOR W/ ROUGH -IN INFO. NECESSARY TO <br />ACCOMMODATE THE INSTALLATIONS OF OWNER FURNISHED <br />AND INSTALLED ITEMS. <br />THE CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED <br />AND INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND <br />SHALL COORDINATE W/ THE OWNER TO ACCOMMODATE THESE <br />ITEMS. <br />COORDINATE ALL DEMOLITION EFFORTS W/ THE OWNER. EVERY <br />EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF <br />OPERATION AND TO PROVIDE PATRON SAFETY. EXCESSIVE <br />N015E OR VIBRATION SHALL BE PRE -APPROVED AND <br />COORDINATED W/THE OWNER. <br />COORDINATE W/ THE OWNER THE PRE -APPROVED DISRUPTION <br />AND VERIFICATION OF SERVICE WITHIN THE EXISTING BUILDING <br />SO AS TO MINIMIZE THE DISRUPTION OF SERVICE. <br />CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN <br />THE EXISTING BUILDING WHICH OFFER AN ENCLOSURE TO <br />ISOLATE ANY DEMOLITION/ CONSTRUCTION WORK FROM THE <br />GENERAL PUBLIC AND 45 DEEMED NECESSARY BY THE <br />OWNER. <br />ABBREVIATIONS: <br />A <br />MODF <br />MODIFIED <br />A.F.F. <br />ABOVE FINISH FLOOR <br />MTD <br />MOUNTED) NNIG) <br />A/C <br />AIR CONDITIONING <br />MTG <br />MOUNTING <br />AB <br />ANCHOR BOLT <br />MTL <br />METAL <br />ABV <br />ABOVE <br />MULL <br />MULLION <br />AC <br />ACCESSORIES <br />Mll <br />MILLWORK <br />ACF <br />ACCESS FLOORING <br />ACT <br />ACOUSTICAL CEILING TILE <br />N <br />AD <br />AREA DRAIN <br />N <br />NORTH <br />ADD <br />ADDENDUM ADJACENT <br />N/A <br />NOT APPLICABLE <br />ADJ <br />ADJUSTABLE <br />N/R <br />NOT REQUIRED <br />AHU <br />AIR HANDLING UNIT <br />NIC <br />NOT IN CONTRACT <br />ALT <br />ALTERNATE <br />NO <br />NUMBER <br />ALUM <br />ALUMINUM <br />NOM <br />NOMINAL <br />ANOD <br />ANODIZED <br />NRC <br />N015E REDUCTION COEFFICIENT <br />AP <br />ACCESS PANEL <br />N5F <br />NET SQUARE FOOTAGE <br />APPROX <br />APPROXIMATE <br />NT5 <br />NOT TO SCALE <br />ARCH <br />ARCHITECT(URE)(URAL) <br />ASPH <br />ASPHALT <br />0 <br />AUTO <br />AUTOMATIC <br />oA <br />OVERALL <br />AUX <br />AUXILIARY <br />OG <br />ON CENTER <br />AVG <br />AVERAGE <br />OD <br />OUT5IDE DIAMETER <br />AWN <br />AWNING <br />OF <br />CUTSIDE FACE <br />AN <br />ACOUSTICAL WALL TREATMENT <br />OH <br />OVERHEAD <br />OPHDD <br />OPPOSITE HAND <br />— <br />OPNIG <br />OPENING <br />BD <br />BOARD <br />OPP <br />OPPOSITE <br />BF <br />81-FOLD <br />BFF <br />BELOW FINISHED FLOOR <br />P <br />BIT/BITUM <br />BITUMINOU5 <br />PCJ <br />PLASTIC CORNER GUARD <br />BLD <br />BOLLARD <br />PEE) <br />PEDASTAL/STAND <br />BLDG <br />BUILDING <br />PL <br />PROPERTY LINE <br />BLK(G) <br />BLOCKING <br />PLAM <br />PLASTIC LAMINATE <br />BLW <br />BELOW <br />PLAS <br />PLASTIC <br />BM <br />BEAM/BENCHMARK <br />PLWD <br />PLYWOOD <br />BN <br />BENCH <br />PNL <br />PANEL <br />BR/BRK <br />BRICK <br />PNT <br />PAINT <br />BRG <br />BEARING <br />POL <br />POLISHED <br />BRKT <br />BRACKET <br />PR <br />PAIR <br />B5 <br />BOTH SIDES <br />PRT <br />PARTITION <br />BTN <br />BOTTOM <br />P51 <br />POUNDS PER SQUARE INCH <br />BTW <br />BETWEEN <br />PT <br />PRESSURE TREATED <br />BUR <br />BUILT-UP ROOF <br />PTD/D <br />PAPER TOWEL D15PENSER/DI5POSAL <br />BVL <br />BEVELED <br />PVC <br />POLY VINYL CHLORIDE <br />C <br />C/C <br />CENTER TO CENTER <br />Q <br />QT <br />QUARRY TILE <br />GAB <br />CABINET <br />QTY <br />QUANTITY <br />CAP <br />CAPACITY <br />ce <br />CATCH BA51N/ GOVE BASIN <br />R <br />GEM <br />CEMENT <br />R/RAI) <br />RADIUS / RI5ER(5) <br />CER <br />CERAMIC <br />RA <br />RETURN AIR <br />GG <br />CORNER GUARD <br />RB <br />RESILIENT BASE <br />CI <br />CAST IRON <br />RGP <br />REINFORCED CONCRETE PIPE <br />CJ <br />CONTROL JOINT <br />RCVG <br />RECEIVING <br />CLG <br />CEILING <br />RE/REF <br />REFER / REFERENCE <br />CLR <br />CLEAR <br />REGPT <br />RECEPTACLE <br />CLST <br />CLOSET <br />REFL <br />REFLECT(ED)(IVE) <br />CM <br />GROU.N MOLDING <br />REFR <br />REFRIGERATION / REFRIGERATOR <br />CMU <br />CONCRETE MASONRY UNIT <br />REG <br />REGISTER <br />COL <br />COLUMN <br />REINF <br />REINFORCED) ONG) <br />COMB <br />COMBINATION <br />READ <br />REQUIRED <br />COMPR <br />COMIPRE55/C71PRESSIBLE <br />RES <br />RESILIENT <br />CONC <br />CONCRETE <br />REV <br />REVISION <br />CONN <br />CONNECT(ION) <br />RGS <br />RIGID GALVANIZED STEEL <br />CONT <br />CONTINUOUS <br />RH <br />RIGHT HAND <br />CONTR <br />CONTRACTOR CON5T CONSTRUCTION <br />R14R <br />RIGHT HAND REVERSE <br />GPT <br />CARPET <br />RM <br />ROOM <br />GR <br />CHAIR RAIL <br />RND <br />ROUND <br />CT <br />CERAMIC TILE / COUNTER TOP <br />RO <br />ROUGH OPENING <br />CTR <br />COUNTER <br />RT <br />RESILIENT TILE <br />CW <br />GOLD WATER <br />RTD <br />RATED <br />RUB <br />RUBBER <br />D__ <br />RUNG <br />RAIN WATER CONDUCTOR <br />D <br />DRYER <br />D.AS.5 <br />DIRECT APPLIED SYNTHETIC STUCCO <br />5 <br />DBL <br />DOUBLE <br />5 <br />SOUTH <br />DEMO <br />DEMOLITION <br />5.YP <br />SOUTHERN YELLOW PINE <br />DEPT <br />DEPARTMENT <br />S/R <br />SHELF 4 ROD <br />DET/DTL <br />DETAIL <br />5A <br />SUPPLY AIR <br />DF <br />DRINKING FOUNTAIN <br />5A5 <br />BOUND ATTENUATION BLANKET <br />DIAM <br />DIAMETER <br />5G <br />SCALE/SOLID CORE <br />DIM <br />DIMENSION <br />5CHED <br />5CHEDULE(D) <br />Dr <br />DISPENSER <br />SECT <br />SECTION <br />DIV <br />DIVISION <br />5ERV <br />SERVICE <br />DN <br />DOWN <br />SF <br />SQUARE FEET/FOOT <br />DR <br />DOOR <br />5GD <br />SLIDING GLASS DOOR <br />DS <br />DOU.N 5POUT <br />514 <br />SINGLE HUNG <br />DW <br />DISHWASHER <br />SHLV <br />SHELVES <br />DWG <br />DRAWING <br />SHT <br />SHEET <br />Sim <br />SIMILAR <br />E <br />SLNT <br />SEALANT <br />E <br />EAST <br />SND <br />SANITARY NAPKIN DISPENSER <br />EA <br />EACH <br />5NR <br />SANITARY NAPKIN RECEPTACLE <br />EIF5 <br />EXTERIOR INSULATION FINISH SYSTEM <br />50H <br />SIMILAR - OPPOSITE HAND <br />EJ <br />EXPANSION JOINT <br />SPEC <br />SPECIFICATION <br />EL <br />ELEVATICN <br />SQ <br />SQUARE <br />ELEC <br />ELECTRIC <br />55T <br />STAINLESS STEEL <br />ELEV <br />ELEVATOR <br />5TC <br />SOUND TRANSMISSION CLASS <br />EMER <br />EMERGENCY <br />STD <br />STANDARD <br />ENCL <br />ENCLOSURE <br />STG <br />SEATING <br />EP <br />ELASTOMERIC PAINT <br />BTL <br />STEEL <br />EQ <br />EQUAL <br />5TOR <br />STORAGE <br />EQUIP/EQPT EQUIPMENT <br />5TRUC <br />5TRUCTURAL/5TRUCTURE <br />EX <br />ELECTRIC WATER COOLER <br />SURF <br />SUWACE <br />EWH <br />ELECTRIC WATER HEATER <br />5U51' <br />SUSPENDED 5W SWITCH <br />EXH <br />EXHAUST <br />5WD <br />STACKED WASHER 4DRYER <br />EXP <br />EXPOSED/ EXPANSION <br />SYM <br />SYMMETRICAL <br />EX5TG <br />EXISTING <br />EXT <br />EXTERIOR <br />T <br />T <br />THREAD(S) <br />F <br />T 4 G <br />TONGUE 4 GROOVE <br />FA <br />FIRE ALARM <br />TOM. <br />TOP OF MASONRY <br />FB <br />FABRICATION <br />TBA <br />TO BE ASSIGNED <br />FBR <br />FACE OF BRICK <br />TBL <br />TABLE <br />FC <br />FILE CABINET <br />TC <br />TOP OF CURB <br />FD <br />FLOOR DRAIN <br />TD <br />TOP OF DRAIN <br />FDN <br />FOUNDATION <br />TEL/TP <br />TELEPHONE <br />FE <br />FIRE EXTINGUISHER <br />TEMP <br />TEMPERATURE / TEMPERED <br />FEC <br />FIRE EXTINGUISHER CABINET <br />TER <br />TERRAllO <br />FF <br />FINISHED FLOOR <br />THK <br />THICK(NE%) <br />FHC <br />FIRE H05E CABINET <br />THRESH <br />THRESHOLD <br />FIN <br />FINISHED) <br />TJ <br />TOOLED JOINT <br />FIXT <br />FIXTURE <br />TOJ <br />TOP OF J015T <br />FL/FLR <br />FLOOR <br />TO5 <br />TOP OF SLAB <br />FLMTD <br />FLOOR MOUNTED <br />TOW <br />TOP OF STEEL <br />FLOUR <br />FLUORESCENT <br />TPD <br />TOILET PAPER DISPENSER <br />FO <br />FINISHED OPENING <br />TYP <br />TYPICAL <br />FOB <br />FACE OF BLOCK <br />FOS <br />FACE OF STUD <br />U <br />FP <br />FIRE'ROOKING) <br />U <br />UNDERCUT <br />FRM <br />FRAME <br />UL <br />UNDERWRITER'S LABORATORY <br />FS <br />FULL SIZE <br />U FN <br />UNFINISHED <br />FT <br />FEET/FOOT <br />UON <br />UNLESS OTHERWISE NOTED <br />FTG <br />FOOTING <br />UTIL <br />UTILITY <br />RUT <br />FUTURE <br />G <br />Y <br />VAR <br />vARIE(5) (D) <br />GA <br />GAGE / GAUGE <br />VB <br />VAPOR BARRIER/ VINYL BASE <br />GAILY <br />GALVANIZED <br />VCT <br />VINYL COMP051TION TILE <br />GAR <br />GARAGE <br />VERT <br />VERTICAL <br />GB <br />GRAB BAR <br />VEST <br />VESTIBULE <br />GG <br />GENERAL CONTRACTOR <br />VIF <br />VERIFY IN RELD <br />GL <br />GLA55 <br />AR <br />VENEER <br />GRIN <br />GRAIN (WOOD) <br />VT <br />VINYL TILE <br />GRND <br />GROUND <br />VUIC <br />VINYL WALL COVERING <br />GIRT <br />GROUT <br />G5F <br />GROSS SQUARE FOOTAGE <br />W <br />GWB <br />GYPSUM WALLBOARD <br />W <br />WIDTH / WEST / WASHER <br />GYP <br />GYPSUM <br />W.G. <br />WATER COOLER <br />W/ <br />WITH <br />H <br />W/o <br />WITHOUT <br />HB <br />HOSE BIB <br />WB <br />WOOD BASE <br />HC <br />HANDICAP <br />WC <br />WATER CL05ET <br />HCR <br />HOLLOW CORE <br />UA <br />WOOD/WOOD VENEER <br />HDW/HDWE <br />HARDWARE <br />WGT/ 0 <br />WEIGHT <br />HDWD <br />HARDWOOD <br />WH <br />WATER HEATER/HYDRANT <br />HGTM/HT <br />HEIGHT <br />WI <br />WROUGHT IRON <br />HM <br />HOLLOW METAL <br />WIG <br />WALK-IN CL05ET <br />HORIZ <br />HORIZONTAL <br />WIN <br />WINDOW <br />HR <br />HOUR <br />WLBP <br />WALL BUMPER <br />HTG <br />HEATING <br />WLP <br />WALLPAPER <br />HVAC <br />HEATING, VENTILATING 4 AIR CONDITIONING <br />W"1 <br />WIRE MESH <br />HW <br />HOT WATER <br />WP <br />WATERPROOF <br />W5 <br />WIRE SHELVING <br />I <br />ID <br />INSIDE DIAMETER/ INSIDE DIMENSION <br />Y <br />NCAND <br />NCANDESCENT <br />Y <br />YARD <br />NCL <br />NCLUDE(D) ONG) <br />Iwo <br />NFOR'1ATION <br />INBUL <br />N5ULATION <br />NT <br />INTERIOR <br />INV <br />INVERT <br />IPS <br />IRON PIPE SIZE <br />J <br />JAN <br />JANITOR <br />JB <br />JUNCTION BOX <br />JC <br />JANITOR CLOSET <br />JST <br />J015T <br />JT <br />JOINT <br />K <br />KIT <br />KITCHEN <br />KO <br />KNOCKOUT <br />KPL <br />KICK PLATE <br />1 <br />LAM <br />LAMINATED) <br />LAV <br />LAVATORY <br />LB <br />POUND <br />LBL <br />LABEL <br />LF <br />LINEAR FOOT/FEET <br />LG/L <br />LONG/LENGTH <br />LH <br />LEFT HAND <br />LHR <br />LEFT HAND REVERSE <br />ILL <br />LIVE LOAD <br />LQ <br />LA=ER <br />LT(G) <br />LIGHTING <br />LVL <br />LAMINATED VENEER LUMBER <br />LW/LTWT <br />LIGHTWEIGHT <br />M <br />MAS <br />MASONRY <br />MATL <br />MATERIAL <br />MAX <br />MAXIMUM <br />MC <br />MEDICINE CABINET <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MD <br />MIDDLE <br />MIN <br />MINIMUM <br />MIn. <br />MINUTES <br />MISC <br />MISCELLANEOUS <br />ML <br />MATCH LINE <br />MLDG <br />MOLDING <br />MO <br />MA50NRY OPENING <br />BUILDING CODE SUMMARY CONSTRUCTION DOCUMENTS FOR: <br />BUILDING DATA : <br />OCCUPANCY : ❑ ASSEMBLY ❑ BUSINESS <br />❑ EDUCATIONAL ❑ FACTORY <br />❑ HIGH HAZARD <br />❑ INSTITUTIONAL Eg"MERGANTILE <br />❑ RESIDENTIAL <br />2'STORAGE <br />❑ UTILITY/MISG <br />❑ DAY CARE <br />USE CONDITION M-RETAIL STORE <br />$-I - MOTOR VEHICLE <br />REPAIR <br />CHANGE OF <br />OCCUPANCY: ❑ YES Q' NO <br />MIXED <br />s?, YES <br />❑ NO <br />CONSTRUCTION ❑ IA ❑ IB <br />OCCUPANCY <br />SEPERATION 2-HR <br />TYPE: ❑ IIA ❑ IIB <br />❑ II IA R, 11I5 <br />MIXED <br />❑ YES <br />Fa' NO <br />❑ IV <br />CONSTRUCTION: <br />❑ VA ❑ VB <br />SPRINKLED: ❑ YE5 R'NO <br />❑ N/A <br />(13 13R 13D): <br />TYPE: <br />COMPLIANCE METHOD: VN/A ❑ PRESCRIPTIVE ❑ WORK AREA <br />❑ PERFORMANCE <br />LEVEL OF ALTERATION: S�' N/A ❑ I <br />❑ 11 <br />❑ III <br />LIFE SAFETY SYSTEM: <br />EMER. LIGHTING 4 EXIT SIGNAGE P YE5 <br />❑ NO <br />❑ N/A <br />FIRE ALARM 4 SMOKE DETECT. SYSTEM ❑ YES <br />M' NO <br />❑ N/A <br />PANIC HARDWARE YES <br />❑ NO <br />❑ N/A <br />PEWITTING AGENCY: <br />CITY OF ZEPHYRHILLS BUILDING DEPARTMENT <br />OCCUPANT LOAD <br />TIRE CHOICE - ZEPHYRHILLS <br />799 GALL BOULEVARD <br />ZEPHYRHILLS, FLORIDA <br />71- <br />_ <br />TOTALS FOOTAGE CALCULATIONS: CITY REVIEW DATE:_ Y OF ZEPHYRHILLSS _174 1�g TOTAL SQUARE FOOTAGE OF BUILDING (GROSS) 5000 SQ FT �,1 <br />OCCUPANCY SQUARE FOOTAGE (NET}. BUILDING OFFICIAL <br />TOTAL SQUARE FOOTAGE MERCANTILE <br />625 5Q. FT. / 30 = 21 PERSONS <br />TOTAL SQUARE FOOTAGE SERVICE AREA <br />3225 SQ. FT. / 100 = 33 PERSONS <br />TOTAL SQUARE FOOTAGE STORAGE AREA <br />1105 SQ. FT. / 300 = 4 PERSONS <br />TOTAL OCCUPANT LOAD <br />58 PEOPLE <br />EXIT WIDTH <br />TOTAL EXIT WIDTH REQUIRED <br />58 X 0.2" = 11,&" <br />TOTAL EXIT WIDTH PROVIDED <br />(1) 3'-0" (1) 4'-0" 4 (2) &'-0" = 140" <br />TOTAL NUMBER OF EXITS REQUIRED <br />2 <br />TOTAL NUMBER OF EXITS PROVIDED <br />4 <br />MAXIMUM ALLOWED TRAVEL DISTANCE <br />250' ALL WORK SHALL COMPLY WITH PREVAILING <br />DIAGONAL TRAVEL DISTANCE <br />101'-5" CODES FLORIDA BUILDING CODE, <br />FIXTURE COUNT SUMMARY: <br />NATIONAL ELECTRIC CODE, <br />TOTAL NUMBER OF OCCUPANTS: <br />58 AND THE CITY OF ZEPHYRHILLS <br />NUMBER OF FIXTURES REQUIRED: <br />I ORDINANCES <br />NUMBER OF FIXTURES PROVIDED: <br />2 (2 UNISEX) <br />PER FBC 1TH EDITION 2020 PLUMBING (MERCANTILE): I W.G. PER 500 PEOPLE <br />Kossik Rd <br />rJULU uct42tlalry,a <br />a <br />Mockingbird <br />Mobile dome Park <br />1 Kozy Acres Dr <br />Boundary Ln <br />d <br />11 <br />{ <br />RJC V TOe., <br />PER FBC 1TH EDITION 2020 PLUMBING (MERCANTILE): I LAV PER 150 PEOPLE Microtel Inn & Suites by <br />PER FBC 1TH EDITION 2020 PLUMBING: I MOP SINK REQUIRED Wyndham ZephyrhiilsA <br />PER FBC 1TH EDITION 2020 PLUMBING: I DRINKING FOUNTAIN PER 1000 PEOPLE i5?l; <br />Capri � a & More "" '"�"' j Cc <br />assik Rd <br />Lq&e's Garden Centei <br />"n ceMet <br />awe's Home <br />mprovement <br />ri �,rcuvemrnl almrn <br />Kossik Rd Kossik Rd <br />7994 Gall Blvd, <br />4Zephyrhills, FL 33 <br />Oft jersey Mike's Stags <br />Sanywacn <br />Adarn. <br />job Re <br />day <br />H arry's 1.of Lrc *ia1 <br />Zephyr Commons <br />ShQpprng rnah — <br />TRAVEL DISTANcE MUL11MI-ItNT5 : FIRE SPRINKLER NOTES: , � I I �c�a�e <br />MAXIMUM COMMON PATH OF EGRESS TRAVEL D15TANCE - 15'-0" FROM <br />ANY POINT W/ GREATER THAN 30 PEOPLE FOR MERCANTILE IN A NOW THI5 SPACE WILL NOT HAVE AFIRE SPRINKLER SYSTEM Truts, �CInase Rank <br />SPRINKLED BUILDING. <br />D , �' The 11PS <br />MAXIMUM TRAVEL DISTANCE TO EXIT - 200'-0'I FROM ANY POINT FIRE ALARM NOTES: I <br />FOR MERCANTILE WITHOUT A SPRINKLER 5Y5TEM. Dollar Tree k IgWells Fargo Banh <br />C'.i'i41rr �torr F 0 T <br />THI5 SPACE WILL NOT HAVE A FIRE ALARM SYSTEM. <br />APPLICABLE CODE5 <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - RESIDENTIAL <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - BUILDING <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - ENERGY <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - TEST PROTOCOL <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - PLUMBING <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - MECHANICAL <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - EXISTING BUILDING <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - FUEL GAS <br />1TH EDITION <br />2020 FLORIDA BUILDING CODE - ACCESSIBILITY <br />1TH EDITION <br />2020 FLORIDA FIRE PREVENTION CODE <br />NEC 2011 <br />NATIONAL ELECTRIC CODE - NFPA 10 <br />FAIR HOUSING GUIDELINES <br />DESIGNED IN ACCORDANCE WITH THE ITN EDITION FLORIDA <br />BUILDING CODE 2020, SECTION 1609 FOR DESIGN PRESSURES. <br />5YMBOL& <br />SECTION OR DETAIL KEY <br />ECTION NO. <br />HEET NO. <br />HOSE BIB <br />® ACOUSTIC PANELS <br />® FACE BRICK <br />0 CONCRETE <br />® CONCRETE BLOCK - C.M.U. <br />® INTERIOR FRAME WALL <br />® WASHED GRAVEL <br />® GYPSUMBOARD <br />RIGID INSULATION <br />BLANKET INSULATION <br />® DIMENSIONAL LUMBER <br />® METAL IN ELEVATION <br />UNDISTURBED 501L OR COMPACTED FILL <br />® PLYWOOD <br />® METAL - LARGE SCALE <br />® INSULATING 5HEATHING <br />50 ELEVATION <br />SECTION CUT <br />X-• DETAIL NUMBER <br />X-• <br />SHEET NUMBER <br />• DETAIL SYMBOL <br />X DETAIL NUMBER <br />SHEET NUMBER <br />ELEVATION SYMBOL <br />X-' ELEVATION NUMBER <br />SHEET NUMBER <br />PARTITION TYPE <br />"NORTH ARROW <br />NOTE THAT NORTH ARROWS SHM IN <br />THESE DRAWINGS IS FOR "REFERENCE" <br />ONLY AND DO NOT REPRESENT TRUE <br />OR MAGNETIC NORTH. <br />1A# C REVISION CLOUD: <br />REVISION <br />AREA REVISED <br />xxx DOOR TYPE SYMBOL <br />OX WINDOW TYPE SYMBOL <br />TRUSS CONSTRUCTION <br />NOTE: <br />• THIS PROJECT 15 DESIGNED TO HAVE STEEL BAR <br />JOISTS. IF FOR SUPPLY REASONS STEEL BAR J015T5 <br />ARE NOT AVAILABLE THEN WE WILL REVISE PLANS TO <br />USE WOOD TRU55E5 <br />EXIT REQUIREMENTS: <br />• ALL EXIT DOORS THAT REQUIRE PANIC HARDWARE <br />WILL MEET THE CRITERIA OF NFPA 1011.211 <br />• PER NFPA 101 12.1.5, DOORS SHALL BE ARRANGED TO <br />BE OPENED READILY FROM THE EGRESS SIDE <br />WHENEVER THE BUILDING IS OCCUPIED. <br />FIRE PREVENTION CODES: <br />• ALL CON5TR11CTION MUST MEET THE REQUIREMENTS <br />OF NFPA 241, 2018 EDITION FOR STANDARD OF <br />SAFEGUARDING CONSTRUCTION, ALTERATION, AND <br />DEMOLITION OPERATIONS. <br />• ALL CONSTRUCTION MUST COMPLY WITH 2O20, 1TH <br />EDITION FLORIDA FIRE PREVENTION CODE (NFPA I <br />AND NFPA 101). <br />• ALL CONSTRUCTION MUST MEET THE CONDITIONS OF <br />NFPA-101 2018 EDITION CHAPTER 10, INTERIOR FINISH <br />CLASSIFICATION LIMITATIONS. <br />• MUST MEET THE REQUIREMENTS OF NFPA-10 2013 <br />EDITION STANDARD FOR PORTABLE FIRE <br />EXTINGUISHERS 4 2018 NFPA 101, SECTION 9.1.4, <br />• ALL FIRE EXTINGUISHERS MUST BE CERTIFIED BY FIRE <br />EXTINGUISHER COMPANY. <br />ALL EXTERIOR WINDOWS AND GLA55 DOORS ARE <br />REQUIRED TO BE TESTED IN ACCORDANCE WITH <br />ANSI/AMMA/NWWDA 101/152 STANDARD AND BEAR AN <br />AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED <br />PRODUCT TESTING ENTITY. <br />ALL WINDOWS AND WALK DOORS SHALL HAVE MINIMUM <br />DESIGN PRESSURES OF +42.6 /-51.0 PSF <br />ALL GARAGE DOORS SHALL HAVE MINIMUM DE51GN <br />PRESSURES OF: <br />= +20.0 /-22A6 P5F <br />16'-0" _ +192 / -21.4 PSF <br />WIND DESIGN METHOD - ALTERNATE ALL HGT METHOD <br />ULTIMATE WIND SPEED (3 5ECOND WIND GUST) 145 <br />MPH <br />NOMINAL WIND SPEED 115 <br />MPH <br />WIND IMPORTANCE FACTOR 1.0 <br />RISK CATEGORY OF STRUCTURE II <br />WIND EXP05URE B <br />WIND ENCLOSURE COEFFICIENT +/ 0.18 (ENCLOSED) <br />COMPONENTS AND CLADDING <br />ROOF * 10 5CFT + 11.0/- 612 <br />Fly, <br />e 20 SQFT + 14.6/- 51fo <br />PSF <br />* 50 SQFT + 12b /- 36.2 <br />P5F <br />• 100 5CFT + ioDl- 382 <br />PSF <br />WALL * 10 SQFT + 228 /- 30.4 <br />PSF <br />* 20 SQFT + 21.1 /- 28.4 <br />P5F <br />d 50 5CFT + 20.4/- 25.1 <br />P5F <br />* 100 5CFT + 193 /- 21.1 <br />PSF <br />OVERHANG - 133A P5F <br />WIND TABLE <br />SCALE: N.T.S. <br />t;� I <br />MWalmart Supercenter; <br />Meahn 2S Beauty <br />VICINITY MAP <br />PROJECT RECORD <br />155UE DATE: 09/20/22 <br />REV151ON DATE REMARK5 <br />ARCHITECTURE <br />A-1 <br />COVER / SPECIFICATIONS / VICINITY MAP <br />A-2 <br />ARCHITECTURAL SITE PLAN <br />1-5-1 <br />LIFE SAFETY PLAN <br />Raven PH ry, � <br />A-3 <br />FLOOR PLAN <br />7a <br />A-4 <br />REFLECTED CEILING PLAN <br />Pi�OJEC :CATION <br />A-5 <br />EQUIPMENT PLAN <br />- <br />A-6 <br />EXTERIOR ELEVATIONS <br />A-1 <br />EXTERIOR ELEVATIONS <br />A-8 <br />ROOF PLAN <br />A-9 <br />BUILDING 5ECTION6 <br />A-10 <br />HG RESTROOM DETAILS <br />Kossik R( <br />A-11 <br />DOOR, WINDOW, 4 FINISH SCHEDULE <br />voy5.'KR4 A-12 WALL 4 PARTITION DETAILS <br />A-13 MISCELLANEOUS DETAILS <br />A-14 DOOR AND WINDOW DETAILS <br />STRUCTURAL <br />51.1 <br />GENERAL NOTES <br />$12 <br />GENERAL NOTES <br />s 52.1 <br />FOUNDATION PLAN <br />522 <br />ROOF FRAMING PLAN <br />523 <br />PLAN NOTES AND SCHEDULES <br />53.1 <br />DETAILS <br />er Market 632 <br />DETAILS <br />,ommons 533 <br />DETAILS <br />MECHANICAL <br />M-1 <br />MECHANICAL COVER SHEET <br />M-2 <br />MECHANICAL FLOOR PLAN <br />M-3 <br />MECHANICAL DETAILS <br />M-4 <br />MECHANICAL SCHEDULES <br />M-5 <br />MECHANICAL 5PECIFICATICN5 <br />Sonnet Landing Ave <br />0 M-6 <br />m <br />MECHANICAL SPECIFICATIONS <br />ELECTRICAL <br />E-I <br />ELECTRICAL COVER SHEET <br />E -2 <br />POWER PLAN <br />E-3 <br />LIGHTING PLAN <br />E-4 <br />LIGHTING SCHEDULE AND DETAILS <br />E-5 <br />POWER R15ER SHEET <br />E-6 <br />PANEL SCHEDULES <br />E-1 <br />ELECTRICAL SPECIFICATIONS <br />PLUMBING <br />P-0 PLUMBING COVER SHEET <br />P-1 PLUMBING SUPPLY PLAN <br />P-2 PLUMBING DRAINAGE UNDER SLAB PLAN <br />P-3 PLUMBING DRAINAGE PLAN <br />P-4 PLUMBING ISOMETRICS <br />P-5 PLUMBING DETAILS <br />P-6 PLUMBING DETAILS <br />P-1 PLUMBING SCHEDULE <br />P-8 PLUMBING SPECIFICATIONS <br />q <br />LL <br />4 0__ <br />Ak <br />LOAO <br />A*9( <br />�JQ �'60- 2 <br />rr <br />THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS <br />AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. <br />AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR <br />OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN <br />CONSENT OF FRANK FRAZE, ARCHITECT, NIA. <br />ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE <br />WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED <br />REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE <br />LAW. <br />+ THE DRAWINGS 4 DESIGN ARE VALID FOR 12 MONTHS FROM DATE <br />OF BEING SEALED. <br />TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND <br />BELIEF, THESE PLANS AND 5PECIFICATION5 COMPLY WITH THE 1TH <br />EDITION 2020 FLORIDA BUILDING CODE. IN ADDITION TO ANY OTHER <br />APPLICABLE BUILDING CODES AND MINIMUM FIRE SAFETY <br />STANDARDS <br />ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE <br />CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED <br />TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />ISSUE <br />DATE er. <br />REVIEW <br />Ce/20/22 MK <br />PERMIT <br />09/20/22 MK <br />REV. <br />RE V. <br />Rr= V. <br />REV. <br />REV. <br />REV. <br />1z. <br />9:,T <br />E f U <br />00 <br />N <br />O N <br />z <br />�00 <br />W <br />a 0 <br />� M <br />00 <br />N <br />M <br />N <br />., <br />U <br />® 00 <br />/ 2y N <br />rn <br />U W � <br />U <br />O � <br />w r+ a <br />SHEET TITLE <br />COVER, <br />5PECIFICATI0N5, <br />4 VICINITY <br />MAP <br />SHEET NUMBER <br />