L __1L+__—I I II__. I'. LL IN I'I I'91 I I II I I I I 1 11 1 1 1 1 1 1 L
<br />INTERIOR FINISH NOTE:
<br />603.1.1 a3e;y .:
<br />INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE
<br />WITH ASTM E 64 OR UL '10. SCOW INTERIOR FINISH MATERIALS SHALL BE
<br />6ROLM IN THE FOLLOWING CLASSES IN ACCORDANCE NTH THEIR FLAME
<br />SPREAD AND SMOKE -DEVELOPED INDEXES.
<br />CLASS A: FLAME 5PREAD 0-25; SMOKES 0-450.
<br />CLASS 5- FLAME SPREAD 26-15; SMOKE -DEVELOPED 0-450.
<br />CLASS C: FLAME SPREAD 16-200; SMOKE -DEVELOPED 0-450.
<br />805.E INTERIOR FINISH REQUIRE 42M BASED ON GROUP:
<br />INTERIOR WALL AND CEILING FINISH SHALL HAVE AFLAME SPREAD INDEX
<br />NOT 6REATER THAN THAT SPEUFIE7 IN TABLE 605A FOR THE 6ROUP
<br />AND LOCATION DE516NATED. INTERIOR WALL AND CEILING FINISH
<br />MATERIALS, OTHER THAN TEXTILES, TESTED IN ACCORDANCE NTH WPA
<br />2k¢ AND MEETING THE ACCEPTANCE CRITERIA OF SECTION 605.1.2.1,
<br />SHALL BE PERMITTED TO BE USED WHERE A CLASS A CLASSIFICATION IN
<br />ACCORDANCE HIM ASTM E 64 OR UL -W 15 REWIRED.
<br />TABLE 803.5 INTERIOR WALL AND CEILING FINISH
<br />REQUIREMENTS BY OCCUPANCY'
<br />NONSPRINKLERED
<br />EXIT ENCLOSURES
<br />ROOMS AND
<br />GROUP
<br />AND a.o
<br />CORRIDORS
<br />ENCLOSED SPACES`
<br />EXIT PASSAGEWAYS
<br />B, E, M,
<br />A
<br />B
<br />C
<br />R-1
<br />A-1 & A-2
<br />A
<br />A
<br />B
<br />A-3, A-4,
<br />A
<br />A
<br />C
<br />A-5
<br />FOR 51, 1 INCH = 25.4 MM, I SQUARE FOOT • 0.042E M2.
<br />A. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED FOR
<br />WAINSCOTTING OR PANELING OF NOT MORE THAN 1,000 SQUARE FEET OF
<br />APPLIED SURFACE AREA IN THE 6RADE LOBBY INHERE APPLIED
<br />DIRECTLY TO A NOWOME111511BLE BASE OR OVER FURRING STRIPS
<br />APPLIED TO A NONCOMB1,15TIBLE BASE AND FIREBLOCKED AS REQUIRED
<br />BY SECTION 603.4.1.
<br />B. IN EXIT ENCLOSURE'S OF BUILIDINSS LESS THAN THREE STORIES IN HEIGHT
<br />OF OTHER THAN 6ROUP 1-5, CLASS B INTERIOR FINISH FOR
<br />NONSPRINKLERED BUILDIN65 AND CLASS, C INTERIOR FINISH FOR
<br />SPRINKLERED BUILDINGS SHALL BE PERMITTED.
<br />C. IMMIRE 4 M5 FOR ROOMS AND L:N WSED SPACES SHALL BE BASED
<br />UPON SPACES ENCLOSED BY PARTITIONS. WHERE A FIRE 4MBISTANGE
<br />RATING 15 REQUIRED FOR STRUCTURAL ELEMENTS, THE ENCLOSING
<br />PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE CEILING.
<br />PARTITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED
<br />ENCASING SPACES AND THE ROOMS OR SPACES ON BOTH SIDES SHALL
<br />BE CONSIDERED ONE. IN DETERMINING THE APPLICABLE RE IREMENTS
<br />FOR ROOMS AND ENCLOSED SPACE5, THE SPECIFIC OCCUPANCY
<br />THEREOF SHALL BE THE 6OVERNIN6 FACTOR REGARDLESS OF THE
<br />6ROUP CLASSIFICATION OF THE BUILDING OR STRUCTURE.
<br />D. LOBBY AREA`,; IN 6ROUP A-1, A-2 AND A-5 OCCUPANCIES SHALL NOT BE
<br />LESS THAN CLASS B MATERIALS.
<br />E. CLASS C INTERIOR FIN15H MATERIALS SHALL BE PERMITTED IN PLACES
<br />OF ASSEMBLY NTH AN OCCUPANT LOAD OF 500 PERSONS OR LESS.
<br />F. FOR PLACES OF F4LI61OUS WORSHIP, WOOD USED FOR ORNAMENTAL
<br />RM05M, TRU5SE5, PANELING OR CHANCE- RMISHIN6 SHALL BE
<br />PERMITTED.
<br />6. CLASS B MATERIAL 15 REQUIRED HERE THE BUILDING EXCEMS TWO
<br />STORIES.
<br />H. CLASS C INTERIOR FIN15H MATERIALS SHALL BE FEW41T W IN
<br />ADMINISTRATIVE SPACES.
<br />I. CLASS C INTERIOR FIN15H MATERIALS SHALL BE PERMITTED IN ROOMS
<br />NTH A CAPACITY OF FOUR PERSONS OR LESS.
<br />J. CLASS B MATERIALS SHALL BE PERMITTED A5 WAINSCOTTING
<br />EXTENDING NOT MORE THAN 46 INCHES ABOVE THE FINISHED FLOOR IN
<br />CORRIDORS.
<br />K. FINISH MATERIALS AS PROVIDED FOR IN OTHER SECTIONS OF THIS CODE.
<br />L- APPLIES WHEN THE EXIT IGIG1.050RE5, EXIT PAS5A6EHAY5, CORRIDORS
<br />OR ROOMS AND ENCLOSED SPACES ARE PROTECTED BY A SPRINKLER
<br />SYSTEM INSTALLED IN ACCORDANCE WITH SM11ON 405.3.1.1 OR 9055,1,2,
<br />R001'''1 FIN15H 5CHEDULE
<br />WALLS
<br />HEIGHT
<br />NO.
<br />ROOM
<br />BASE
<br />FLOORS
<br />CEILING
<br />(VIF)
<br />COMMENTS
<br />N
<br />S
<br />E
<br />W
<br />WSERVICE
<br />BAY
<br />NA
<br />PT.
<br />PT.
<br />PT.
<br />PT.
<br />SEALED
<br />EXPOSED
<br />APROX 15'-4'
<br />SEE SERVICE BAY
<br />CONC
<br />NOTE BELOW
<br />101
<br />TIRE STORAGE
<br />NA
<br />PT.
<br />PT.
<br />PT.
<br />PT.
<br />CONC.
<br />EXPOSED
<br />APROX 15'-4"
<br />WALLS: SW
<br />MA:RS14MALLOW SW 1001
<br />102
<br />RECEPTION
<br />VB
<br />PT.
<br />PT.
<br />PT.
<br />PT.
<br />LVT
<br />ACT -BLACK
<br />10'-0"
<br />WALLS: SW MORNING
<br />FOG SLU6255
<br />103
<br />WAITING ROOM
<br />VB
<br />PT.
<br />PT.
<br />PT.
<br />PT,
<br />LVT
<br />ACT -BLACK
<br />10'-0"
<br />WALLS: SW MORNING
<br />FOG SW62%
<br />104
<br />UNISEX HC RR
<br />CT.
<br />FRP-W
<br />FRP-W
<br />FRP-W
<br />FRP-W
<br />LVT
<br />ACT -WHITE
<br />8'-011
<br />WHITE FRP
<br />105
<br />LNISEX HC RR
<br />CT.
<br />FRB-B
<br />FRB-B
<br />FRB-B
<br />FRB-B
<br />LVT
<br />ACT -WHITE
<br />V-0"
<br />BLACK FRP
<br />106
<br />SERVICE DESK
<br />NA
<br />PT.
<br />PT.
<br />PT.
<br />PT.
<br />SEALED
<br />EXPOSED
<br />APROX 15'-4'
<br />SEE SERVICE BAY
<br />CONC
<br />NOTE BELOW
<br />101
<br />IT CLOSET
<br />VB
<br />PT.
<br />K.
<br />PT.
<br />PT.
<br />LVT
<br />EXPOSED
<br />EXPOSED
<br />FLOORS
<br />BASES
<br />WALLS
<br />CEILINGS
<br />A
<br />EXISTING CONC. FLOOR
<br />I
<br />2x6 WOOD
<br />FRP
<br />FIBERGLASS REINFORCED
<br />EXP.
<br />EXPOSED
<br />PLASTIC
<br />CT.
<br />CERAMIC TILE
<br />VB
<br />VINYL BASE
<br />PT
<br />PANT
<br />VLT
<br />LAMINATE FLOORNG
<br />GYP
<br />GYP CEILING
<br />CONC.
<br />SEALED CONCRETE
<br />FINISH SCHEDULE
<br />1 SCALE: N.T.5.
<br />SERVICE BAY WALL FINISH NOTES:
<br />• FROM FINISHED FLOOR TO W-0" ABOVE PAINT WALL: SW MORNING FOG
<br />SW6255 - GLOSS EXPOY
<br />• NEXT ADD 12" PANT STRIPE: SW HONORABLE BLUE SW6811 - EGGSHELL
<br />• FROM STRIPE UP TO CEILING PANT: SW MARSHMALLOW SW1001 - EGGSHELL.
<br />e uu
<br />0
<br />EXTERIOR
<br />STOREFRONT, IMPACT
<br />3' -0"
<br />A
<br />�n
<br />B /
<br />0
<br />cn it1 Lu
<br />INTERIOR PASS
<br />THROUGH WINDOW
<br />GLAZING 5CHEDULE
<br />MARK
<br />FRAME MAT.
<br />FRAME FINISH
<br />GLASS MAT.
<br />GLASS
<br />TINT
<br />MANUFACTURER
<br />MODEL
<br />SIZE
<br />PRODUCT APPROVAL
<br />A
<br />ALUMINLM
<br />CLEAR ANODIZED
<br />IMPACT RESISTANT
<br />GRAY
<br />YYK AMERICA
<br />YFW 400 TUH
<br />(2) 6'-0' X 4'-0" FIXED
<br />FL' 1326W
<br />B
<br />H11.
<br />H.M.
<br />TEMPERED
<br />NA
<br />Cm
<br />DW4200A
<br />Y-0" X Y-O" HORIZ SLIDER
<br />NOTE:
<br />ALL EXTERIOR GLAZING 15 IMPACT RESISTANT MEETING THE REQUIREMENTS OF SSTO 12, ASTM E 1686 AND ASTM E ISS6, AND SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE
<br />TEST IN ACCORDANCE WITH 1606.1.4, 200-1 FBC, AND HAVE MIAMI-DADS PRODUCT APPROVALS.
<br />WINDOW SCHEDULE
<br />3 SCALE: I/4" = I'—O"
<br />12'-4"
<br />3' - 4 Lo 3'-4 3' -4"
<br />0
<br />11 ^l l_�11 I II �1_0�I I II �I_011 I 11 11_011 11_011 I '_
<br />-,
<br />A / % cv
<br />0 0 0 0 0
<br />H.M. DOOR H.M. INTERIOR DOOR H.M. INTERIOR DOOR H.M. INTERIOR DOOR ALUM. EXTERIOR DOOR
<br />1/2 6LA55 5Y5TEM
<br />lid'-01,
<br />HARDWARE NOTES:
<br />I. BOTH SIDES OF DOOR OR GATE SHALL HAVE THE SAME ELEVATION WITH
<br />NO MORE THAN }" DIFFERENCE ON EACH SIDE.
<br />2. HARDWARE SHALL BE LEVER HANDLED TO MEET REQUIREMENTS OF THE
<br />ADA t THE FLORIDA ACCESSIBILITY CODE. PROVIDE SARGENT 6500
<br />SERIES CYLINDRICAL LEVER HANDLE LOCK5ET (OR EQUAL).
<br />3. PANIC HARDWARE OR FIRE EXIT HARDWARE, AS REQUIRED BY NFPA-101
<br />SECTIONS 122223 AND 12222.4 AND FBC 1008.1.9. PROVIDE STANDARD
<br />PULL WITH KAWNEER PANELNNE CONCEALED ROD EXIT DEVICE OR
<br />KAWNEER 1686 CONCEALED EXIT DEVICE, THIS IS USED ON STOREFRONT
<br />GLASS DOORS.
<br />4. PANIC HARDWARE OR FIRE EXIT HARDWARE, AS REQUIRED BY NFPA-101
<br />SECTIONS 122223 AND 12222.4 AND FBC 1008.1.18. PROVIDE SARGENT 80
<br />SERIES RIM EXIT DEVICE OR EQUAL.
<br />0 0
<br />EXTERIOR ROLL H.M. DOOR EXTERIOR
<br />UP DOOR IMPACT
<br />DOOR SCHEDULE
<br />MARK
<br />LOCATION
<br />LOCK TYPE
<br />DOOR
<br />FRAME
<br />REMARKS
<br />FLORIDA PRODUCT
<br />FLORIDA
<br />SIZE
<br />E
<br />MAR.
<br />FIN.
<br />MAD.
<br />FIN
<br />100
<br />SIDE ENTRY/EXIT
<br />ENTRY LOCKSET
<br />Y-0" X T-0" X I "
<br />A
<br />H.M.
<br />PT.
<br />H.M.
<br />PT.
<br />PANIC HARDWARE
<br />FL' 1345%1
<br />WA
<br />OVERHEAD SERVICE
<br />10'-0' X 10'-0"
<br />F
<br />H.M.
<br />PT.
<br />W.M.
<br />PT.
<br />OVERHEAD COILING
<br />FLO 1422
<br />100E
<br />OVERHEAD SERVICE
<br />10'-0' X 10'-0'
<br />F
<br />H.M.
<br />PT.
<br />HA
<br />PT.
<br />OVERHEAD COILING
<br />FL' 1422
<br />100C
<br />OVERHEAD SERVICE
<br />10'-0' X 10'-0"
<br />F
<br />HA
<br />PT.
<br />HM.
<br />PT.
<br />OVERHEAD COILING
<br />FL' 1422
<br />100D
<br />OVERHEAD SERVICE
<br />10'-0' X 10'-0"
<br />F
<br />Hit
<br />PT.
<br />WM.
<br />PT.
<br />OVERHEAD COILING
<br />FLO 1422
<br />100E
<br />OVERHEAD SERVICE
<br />I0'-ON X 10'-0"
<br />F
<br />H.M.
<br />PT.
<br />H.M.
<br />PT.
<br />OVERHEAD COILING
<br />FL' 1422
<br />100F
<br />OVERHEAD SERVICE
<br />10'-0" X 10'-0"
<br />F
<br />HM.
<br />PT.
<br />HM.
<br />PT.
<br />OVERHEAD COILING
<br />FL' 1422
<br />100G
<br />OVERHEAD SERVICE
<br />10'-0" X 10'-O'
<br />F
<br />H.M.
<br />PT.
<br />H.M.
<br />PT.
<br />OVERHEAD COILING
<br />FL' 1422
<br />101A
<br />TIRE STORAGE ENTRI'/EXIT
<br />ENTRY LOCKSET
<br />4'-0" X T-0" X I IN
<br />G
<br />HM.
<br />PT.
<br />H.M.
<br />PT.
<br />PANIC HARDWARE
<br />FL' 1345SLI
<br />1015
<br />TIRE STORAGE
<br />PASSAGE LOCKSET
<br />PR Y-0' X T-0" X I
<br />D
<br />W.M.
<br />PT.
<br />H.M.
<br />PT.
<br />W MIN. FIRE RATED
<br />102A
<br />RECEPTION
<br />ENTRY LOCKSET
<br />6'-0' X 8'-0' X I in
<br />E
<br />ALUM
<br />PT.
<br />A.L.M.
<br />PT.
<br />FL' 142185
<br />1025
<br />RECEPTION
<br />ENTRY LOCKSET
<br />6'-0" X 8'-0" X I I"
<br />E
<br />ALUM
<br />PT.
<br />ALUM.
<br />PT.
<br />FL' 142185
<br />102C
<br />RECEPTION
<br />PASSAGE LOCKSET
<br />Y-0" X T-0" X I in
<br />C
<br />HM.
<br />PT.
<br />H.M.
<br />PT.
<br />103
<br />WAITING ROOM
<br />PASSAGE LOCKSET
<br />Y-0' X T-0" X I in
<br />C
<br />HM.
<br />PT.
<br />H.M.
<br />PT.
<br />104
<br />UNISEX HC RR
<br />PRIVACY LOCKSET
<br />Y-0' X T-0" X I IN
<br />B
<br />HM.
<br />PT.
<br />W.M.
<br />PT.
<br />CLOSER
<br />105
<br />UNISEX HC RR
<br />PRIVACY LOCKSET
<br />Y-O" X T-0" X I IN
<br />B
<br />H.M.
<br />PT.
<br />H.M.
<br />PT.
<br />CLOSER
<br />101
<br />IT CLOSET
<br />ENTRY LOCKSET
<br />2'-6" X T-0" X 11"
<br />D
<br />H.M.
<br />PT.
<br />H.M.
<br />PT.
<br />DOOR SCHEDULE
<br />2 SCALE: I/4" = I'—O"
<br />HARDWARE SCHEDULE
<br />DESCRIPTION
<br />MANF.
<br />SPECIFICATION
<br />FINISH
<br />COMMENTS
<br />BRUSH 26-D
<br />0 BOTTOM OF OOR
<br />DEADEIOLT
<br />ON
<br />LOCKSET/CYLINDER
<br />SARGENT
<br />6500 SERIES
<br />JAL FN ISH
<br />OR EQQUAL FIN
<br />BUMB ASE) W/ THTURN
<br />INTERIOR SIDE
<br />(2) SURFACE INTERMEDIATE
<br />COORDINATE WITH
<br />TOP OFFSET HUNG FREE SWING
<br />RIXON
<br />MI90
<br />POLISH CHROME PLATED
<br />MANIFACTURER RECOMMENDED
<br />PIVOT
<br />RAILS AND ACCESSORIES.
<br />(U BOTTOM OFFSET PIVOT SET
<br />RIXON
<br />541
<br />POLISH CHROME PLATED
<br />BY W.
<br />(U PER DOOR IN OPEN POSITION
<br />FLOOR STOP DOME
<br />IVES
<br />FS-13
<br />POLISH CHROME PLATED
<br />TO PREVENT DOORS FROM
<br />HITTING WALLS
<br />CLOSER
<br />NORTON COPNTROLS
<br />8501-REGULAR ARM
<br />5RJSH ALIJ1W 26-0
<br />OR EQUAL FINISH
<br />BY GEC.
<br />ADD TO ALL NEW AND EXISTING
<br />PANIC HARDWARE
<br />SARGENT
<br />80 SERIES
<br />BRUSH ALUMINIV 26-0
<br />EGRESS EXIT DOORS THAT
<br />OR EQUAL FINISH
<br />REQUIRE PANIC HARDWARE PER
<br />CODE
<br />�a
<br />THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS
<br />AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC.
<br />AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR
<br />OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN
<br />CONSENT OF FRANK FRAZE, ARCHITECT, AIA.
<br />ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE
<br />WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED
<br />REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE
<br />LAW.
<br />* THE DRAWINGS d DESIGN ARE VALID FOR 12 MONTHS FROM DATE
<br />OF BEING SEALED.
<br />TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND
<br />BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE ITH
<br />EDITION 2020 FLORIDA BUILDING CODE. IN ADDITION TO ANY OTHER
<br />APPLICABLE BUILDING CODES AND MINIMUM FIRE SAFETY
<br />STANDARDS
<br />ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE
<br />CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED
<br />TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION,
<br />ISSUE
<br />DATE BY.
<br />REVIEW
<br />09/20/22 MK
<br />PERMIT
<br />OS/20/22 MK
<br />REV.
<br />REV.
<br />REV.
<br />1E V.
<br />REV.
<br />RE V.
<br />REV.
<br />SHEET TITLE
<br />WALL PARTITION,
<br />DOOR 4 FINISH
<br />SCHEDULES
<br />SHEET MUMPS
<br />A� 11
<br />IN
<br />
|