LOAD SUMMARY <br />DESCRIPTION kVA <br />TO SWITCH A <br />REAR DOOR <br />1 <br />w <br />Q <br />TO SWITCH * <br />REAR DOOR <br />1 <br />\TO SWITCH m �TO SWITCH • <br />REAR DOOR REAR DOOR <br />250.S4 BONDNG FOR OTHER SYSTEMS. AN INTERSYSTEM BONDING TERMINATION <br />FOR CONNECTING INTERSYSTEM BONDING AND GROUNDING CONDUCTORS <br />REQUIRED FOR OTHER SYSTEMS SHALL BE PROVIDED EXTERNAL TO <br />ENCLOSURES AT THE SERVICE EQUIPMENT AND AT THE DISCONNECTING MEANS <br />FOR ANY ADDITIONAL BUILDINGS OR STRUCTURES. THE INTERSYSTEM BONDING <br />TERMINATION SHALL BE ACCESSIBLE FOR CONNECTION AND INSPECTION. THE <br />INTERSYSTEM BONDING TERMINATION SHALL HAVE THE CAPACITY FOR <br />CONNECTION OF NOT LESS THAN THREE INTERSYSTEM BONDING CONDUCTORS. <br />THE INTERSYSTEM BONDING TERMINATION DEVICE SHALL NOT INTERFERE WITH <br />OPENING A SERVICE OR METERING EQUIPMENT ENCLOSURE. <br />THE INTERSYSTEM BONDING TERMINATION SHALL BE ONE OF THE FOLLOWING: <br />(1) A SET OF TERMINALS SECURELY MOUNTED TO THE METER ENCLOSURE <br />AND ELECTRICALLY CONNECTED TO THE METER ENCLOSURE. THE <br />TERMINALS SHALL BE LISTED AS GROUNDING AND BONDING <br />EQUIPMENT. <br />(2) A BONDING BAR NEAR THE SERVICE EQUIPMENT ENCLOSURE, METER <br />ENCLOSURE, OR RACEWAY FOR SERVICE CONDUCTORS. THE <br />BONDING BAR SHALL BE CONNECTED WITH A MINIMUM 6 AWG <br />COPPER CONDUCTOR TO AN EQUIPMENT GROUNDING <br />CONDUCTOR(S) IN THE SERVICE EQUIPMENT ENCLOSURE, METER <br />ENCLOSURE, OR EXPOSED NONFLEXIBLE METALLIC RACEWAY. <br />(3) A BONDING BAR NEAR THE GROUNDING ELECTRODE CONDUCTOR <br />THE BONDING BAR SHALL BE CONNECTED TO THE GROUNDING <br />ELECTRODE CONDUCTOR WITH A MINIMUM 6 AWG COPPER <br />CONDUCTOR <br />( 3) 6, 8G C <br />FROM <br />(3)6 <br />TO UTILI <br />TRANSFORMER <br />■ <br />ELECTRICAL RISER <br />NTS <br />C T R I C A <br />' CU <br />:ORDANCE <br />C 250 <br />PLAN <br />ELECTR I C,4L SI*T " 50LS LECxEN1:) <br />CEILING LIGHT m 200 AMP. PANEL ® TELEVISION PRE -WIRE <br />-(R} RECESSED CAN LIGHT — — — — — — — - SHOP FLUORESCENT TELEPHONE PRE -WIRE <br />t___----'l LIGHT <br />110v DUPLEX RECEPTACLE <br />• SMOKE ALARM <br />2'X 4' FLUORESCENT CARBON MONOXIDE <br />220V OUTLET I I LIGHT ® DETECTOR <br />F.I. 110V GF.I. OUTLET JO JUNCTION BOX <br />TRACK LIGHTING <br />SWITCHED DUPLEX REC.4 PUSH BUTTON <br />BEAUTY BAR LIGHT I CHIMES, ETC.) <br />® OUTLET (HWH, AH, ETC.) FLOOD LIGHT <br />SINGLE POLE SWITCH \� BRACE t ® DOOR BELL CHIME <br />1 PRE -WIRE i��• ELECTRICAL WIRING <br />THREE WAY LIGHT SWITCH / FOR FAN <br />\ / <br />Vy GARAGE DOOR OPENER � � � � EXHAUST FAN <br />L J <br />ElLIGHT/EX. FAN <br />ALL ELECTRICAL 5WITCHES, <br />OUTLETS, ETC. TO BE MOUNTED <br />ABOVE THE BASE FLOOD <br />ELEVATION. (SEE SITE PLAN <br />FOR BASE ELEVATION) <br />INTERIOR ELECTRICAL OUTLET LOC4T I ONS <br />PADDLE FAN SWITCH <br />(LOCATE OVER FAN <br />LIGHT SWITCH) <br />LIGHT SWITCH <br />DUPLEX OUTLET AT <br />KITCHEN COUNTER, REFRIG., <br />° WASHER AND GARAGE OUTLETS <br />DUPLEX OUTLET AT <br />° o VANITY COUNTER <br />lk <br />STANDARD <br />DUPLEX OUTLET <br />v v - <br />0 <br />v o <br />9 <br />n <br />ELECTRICAL NOTES <br />ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES SUCH AS THE NATIONAL <br />ELECTRICAL CODE 2011, LOCAL ORDINANCES AND POWER COMPANY REGULATIONS. <br />SUBCONTRACTOR SHALL BE LICENSED, CARRY ALL APPLICABLE.INSURANCE, AND HAVE A CURRENT COUNTY <br />OCCUPATIONAL LICENSE. AS ALLOWED, CONNECT ADDITIONAL ELECTRICAL TO EXISTING CIRCUITS. <br />SUBCONTRACTORS SHALL INCLUDE ALL SPECIAL FEES AND PERMITS, LABOR AND MATERIAL, EQUIPMENT AND <br />ELECTRICAL ENGINEERING NECESSARY TO PROVIDE AN APPROVED WORKING SYSTEM. LIGHT FIXTURES EXCLUDED <br />EXCEPT FOR FLUORESCENT FIXTURES AND RECESSED LIGHTS. <br />CONCRETE -ENCASED ELECTRODE. AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WITHIN <br />AND NEAR THE BOTTOM OF THE CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE <br />EARTH, CON515TING OF AT LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICITY <br />CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LE55 THAN 1/2 INCH DIAMETER, OR CONSISTING <br />OF AT LEAST 20 FEET OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4 AWG. REINFORCING BARS SHALL BE <br />PERMITTED TO BE BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER EFFECTIVE MEANS." <br />210.12 ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION. <br />(A) DEFINITION: ARC -FAULT CIRCUIT INTERRUPTER (AFCI). A DEVICE INTENDED TO PROVIDE PROTECTION FROM <br />THE EFFECTS OF ARC FAULTS BY RECOGNIZING CHARACTERISTICS UNIQUE TO ARCING AND BY FUNCTIONING TO <br />DE -ENERGIZE THE CIRCUIT WHEN AN ARC FAULT 15 DETECTED. <br />(B) DWELLING UNITS. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, <br />BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND OTHER SPECIFIED ROOMS OR AREAS <br />SHALL BE <br />PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE <br />PROTECTION OF THE BRANCH CIRCUIT. <br />CARBON MONOXIDE ALARMS <br />R315.1 CARBON MONOXIDE PROTECTION. EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING BUILDING FOR <br />WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED AND HAVING A FOSSIL -FUEL -BURNING HEATER OR APPLIANCE, A <br />FIREPLACE, AN ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE AS A <br />BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET <br />(3048 mm) OF EACH ROOM USED FOR SLEEPING PURPOSES. <br />EXCEPTION: THIS SECTION SHALL NOT APPLY TO EXISTING BUILDINGS THAT ARE UNDERGOING ALTERATIONS OR <br />REPAIR UNLESS THE ALTERATION 15 AN ADDITION AS DEFINED IN SECTION R315.13. <br />R315.1.1 CARBON MONOXIDE ALARM. THE REQUIREMENTS OF SECTION R315.1 544ALL BE SATISFIED BY PROVIDING FOR <br />ONE OF THE FOLLOWING ALARM INSTALLATIONS: <br />(1) A HARD -WIRED CARBON MONOXIDE ALARM. <br />(2) A BATTERY -POWERED CARBON MONOXIDE ALARM. <br />(3) AWARD -WIRED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />(4) A BATTERY -POWERED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />R315.12 COMBINATION ALARMS. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED AND LABELED <br />BY A NATIONALLY RECOGNIZED TESTING LABORATORY. <br />R315.13 ADDITION SHALL MEAN: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A <br />BUILDING OR STRUCTURE <br />CV <br />O <br />cV <br />fM <br />Signed and scaled by T.L. Hanson PH <br />Thomas L Digitally signed by � riHry , <br />using a Digital Signature and date. P' • -N• e 301 <br />Thomas L �.•�c • <br />Hanson:A01410 Printed copies of this document `'tI <br />Hanson:A01410D000001 are not considered signed and 9 <br />D00000177EF31 77EF3164E000015ADA sealed and the signature must be =_ w <br />Date: 2021.05.24 verified on any electronic co � �^ P % ` <br />B4E000015ADA 08:46:08-04'00' <br />