My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36410 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36410 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:30:03 AM
Creation date
2/19/2025 1:52:01 PM
Metadata
Fields
Template:
Building Plans
Street #
36410
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />O O <br />8F8-0B/1 T <br />.' p <br />-1 v,• vdv <br />O D OO O •O. O <br />8RF14-1B/1T8RF14-0B/1T 8F16-1B/1T <br />© 0 <br />vdv 'v �v as <br />o�v <br />O � O <br />8F16-0B/1T -0 <br />OO o o o <br />8F20-1B/1T 81=20-013/1T <br />O O <br />TYPE DESIGNATION <br />#5 REBAR <br />AT TOP <br />F = FILLED WITH <br />MIN. <br />(1) REQ'D <br />GROUT / U = UNFILLED <br />1/2" <br />a ° <br />R = RECESSED <br />H <br />CLEAR <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />QW <br />°° e <br />8F16— B/1T <br />ao <br />�° <br />z <br />° , <br />GROUT <br />tNOMINAt. QUANTITY OF <br />5 REBAR AT <br />WIDTH #5 REBAR AT <br />° O <br />BOTTOM OF <br />TOP <br />LINTEL CAVITY <br />NOMINAL- <br />o"*-BOTTOM <br />REINFORCING <br />HEIGHT <br />PROVIDED IN LINTEL <br />7-5/8-ACTUAL <br />(VARIES) <br />8" NOMINAL WIDTH <br />MATERIALS <br />ttc precast lintels = 3500 psi. <br />Pc prestressed lintels = 6000 psi. <br />§routed per ASTM C476 fg = 3000 psi w/ <br />Maximum 3/8" aggregate and 8" to 11" slump. <br />Soncrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength =1900 psi. <br />Rebar per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />270 low relaxation. <br />7/32 wire per ASTM A510. <br />Mortar per ASTM C270 type M or S. <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L1180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with vertical (gravity and uplift) and horizontal (lateral) <br />loads should be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load G� <br />I <br />Safe vertical load Safe horizontal load — .O <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D 1-1/2" CLEAR <br />J <br />W <br />F - C.M.U. <br />in <br />0 m <br />Cn�=WWW <br />LauC,30z <br />a <br />o LUCj <br />to <br />Z 5 REBAR AT BOTTOM <br />Z Cra ¢ — = MIN. (1) REQ'D <br />fA Ll.O tr <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required top and <br />bottom of all Powers Steel lintels. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitious coating. See contractor specifications <br />_ 8RF6-0B/1T <br />v <br />�• <br />O O <br />"O- <br />' <br />8F20-1 B-2T <br />O O <br />O O <br />8F24-1 B/1 T <br />8F24-0B/1 T <br />O <br />O <br />A <br />A <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />A <br />A <br />2ND FLOOR LINTEL PLAN <br />SCALE: 3/16"=1 r-0" <br />SYMMETRICAL <br />I <br />OMIN. OMIN. OMIN. <br />MIN. MIN. MIN. <br />1ST FLOOR LINTEL PLAN <br />SCALE: 3/16"=1 r-0" <br />SYMMETRICAL <br />I <br />N <br />S N <br />c <br />W <br />G <br />a� o <br />CZLA- <br />m <br />� ac <br />• N <br />V O 10 <br />3� <br />N a� <br />C <br />A O <br />L1. y <br />i <br />O <br />c'M <br />CV <br />O <br />N <br />N <br />O <br />�E <br />00�.-*\G <br />N S�G•r�'°�i <br />c� <br />• No P <br />w <br />787 <br />w : <br />� <br />ST <br />TE OF �. <br />r. <br />r�!Ae <br />%% <br />�E0-0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />W <br />�E <br /># <br />F <br />ON <br />O N u LL <br />N <br />a <br />() V <br />a 4 <br />3 <br />co LL ii <br />a <br />= <br />10 <br />r v 0 <br />L�2.- a � o <br />rn z <br />000 <br />rn <br />Z <br />LW <br />w <br />L0 C.O.Z g. <br />N W f <br />O U ❑❑❑ <br />Z <br />Z <br />W <br />V M � <br />N M <br />o � <br />Z � N <br />� � <br />Q <br />cl- <br />V) <br />N <br />z v <br />_ <br />0 0 <br />a--+ <br />— <br />cn <br />w � <br />� W <br />U <br />Ow <br />Vl <br />V1 <br />c <br />� <br />U <br />w <br />x$ i <br />y <br />c C <br />MD <br />N <br />� m <br />C <br />JZ <br />W <br />M <br />M <br />J <br />h Q <br />SS <br />o¢ <br />Z <br />2 <br />L.L <br />n3E <br />zo <br />>m <br />L1 0 <br />WF <br />z® <br />F— CIL <br />-� <br />p <br />r <br />� o <br />Z <br />�p <br />o <br />a z <br />wo <br />C/7foz¢ <br />3y <br />m0 <br />Ow <br />Z <br />m <br />m <br />Q <br />� <br />Z <br />8 <br />`! <br />8a <br />0 <br />go <br />�w <br />W <br />o� <br />J <br />Q <br />Q <br />W) <br />ch-0.a <br />v <br />T <br />= <br />oz <br />c <br />•° T <br />>� <br />ti <br />rn <br />N0 <br />CTO <br />CV <br />CM <br />L. <br />Co <br />T <br />r <br />T <br />'\ <br />CDCE <br />O <br />T <br />)^� <br />Vm <br />T <br />�- <br />O <br />In <br />N <br />0O <br />O <br />T <br />N <br />L.n <br />,6 <br />N <br />ai <br />� <br />O <br />0 <br />Z <br />m <br />Z <br />E O <br />N <br />r <br />_ <br />E <br />v ?? <br />c <br />a <br />U -j <br />Q 0 <br />-i <br />JOB <br />NO :23-13131-13136 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />L 1 <br />I <br />UMI <br />IMI <br />i, <br />171M <br />n= <br />IMI <br />r;i <br />
The URL can be used to link to this page
Your browser does not support the video tag.