GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed Joints. <br />2, Shore filled lintels as required. <br />3. 1 nstallatlon of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5, All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the Ilntel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -In -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />it. The exterior surface of lintels installed In exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load <1 .O <br />Safe vertical Ioa Safe horizontal load — <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />Num <br />8F44 1 B/1 T 8F40 1 B/1 T 8RF400B/1T 8F321B/1T <br />® © ® 8 <br />FORM k GROUT SOLID <br />4 LU <br />0 /5 BAR CONY. <br />8F12-1 B/1T <br />O <br />V' LINTEL DETAIL <br />SCALE = N.T.S. <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />a ° <br />R = RECESSED <br />QTY. OF #5 <br />° <br />REBAR @ BOTTOM <br />° <br />OF LINTEL CAVITY <br />a <br />_ <br />°4 • <br />8F16— B/1T <br />a <br />= <br />- <br />° ° <br />�• <br />?S <br />'h <br />O <br />Z <br />to• <br />tNOMINAL, QUANTITYOF <br />WIDTH #5 REBAR AT <br />° <br />TOP <br />NOMINA <br />° <br />HEIGHT <br />MATERIALS <br />cTi'�lfntels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />-#5 REBAR AT TOP <br />IN. (1) REQ'D <br />LEAR <br />GROUT <br />5 REBAR AT <br />BOTTOM OF <br />LINTEL CAVIT <br />—BOTTOM <br />REINFORCING <br />L PROVIDED IN <br />DTH " LINTEL <br />(VARIES) <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />2x8 #2 SYP STUDS @ 8" O.C. W/ (2) <br />SIMPSON MSTAM36 STRAPS EACH <br />STUD ((1) STRAPS EACH SIDE) <br />CENTERED W/ (13) 10d NAILS & (8) Y4" <br />TITENS <br />OR <br />(2) 2x8 #2 SYP STUDS @ 16" O.C. W/ <br />(4) SIMPSON MSTAM36 STRAPS ((2) <br />STRAPS EACH SIDE) <br />2x8 #2 SYP P.T. BASE PLATE <br />W/ y2" EPDXY ANCHOR OR Y2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />32" O.C. & 6" FROM EACH END <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D 1-1/2" CLEAR <br />r` J z <br />rn w � X C.M.U. <br />_NV)W <br />U,o�U9Z <br />J <br />ZLL <br />4wp 5 REBAR AT BC <br />rn m tY S ui AS INDICATED <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for Installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel Is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />OILSEE PLAN <br />"FT/WALL <br />8" KNOCKOUT COURSE <br />W/ (1) #5 CONT. <br />SEE PLAN FOR FILLED CELL <br />SPACING <br />1 WALL SPLICE DETAIL <br />8 SCALE: 1" = 1'-0" <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />5'-8" LL <br />LINTEL PLAN — ELEV—Al <br />SCALE: Y4'=1'-0" <br />e'•'7r <br />9lMl <br />ItRli <br />a> -a <br />T W <br />a L <br />C= <br />-' <br />C r0 C� N <br />cn. <br />ro <br />N O � <br />3 -C a� <br />o- °' <br />as � c <br />m o Q <br />3 <br />w m ae .n <br />�E <br />�o <br />w <br />fill <br />To the hest of the Engineers knowledge. Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a <br />g C <br />M <br />fi) <br />tA�� •J° <br />M a2 LL <br />2ssz J <br />J LL W <br />V�lL <br />I� <br />S <br />S8. a <br />= <br />m rn <br />M g <br />L ttl0 <br />W <br />W�4'0' <br />_ <br />�e <br />to C � O O <br />m <br />ILL= <br />N NZa0 <br />Z <br />OU <br />0 <br />CO <br />Z <br />=§1 <br />Q <br />13 <br />U) <br />N <br />a <br />N <br />Z - <br />U <br />0 <br />IZL <br />cn <br />l'73 <br />'U <br />w <br />OW <br />Ul <br />o <br />- <br />C) <br />< oo <br />• <br />C4 <br />iZZ <br />M <br />r{- E <br />�O <br />U <br />ZZ3 <br />Q <br />Q <br />U <br />wz <br />oa <br />pQ <br />�P E <br />10 <br />� <br />T Z <br />U <br />�U <br />°a <br />W Z <br />Z <br />� ro <br />� o <br />C <br />nZ <br />sy <br />Z <br />aa <br />rz <br />�Z <br />o <br />W <br />m <br />a <br />F <br />o <br />w0 <br />�C) <br />J <br />L <br />rn <br />0 <br />'Q <br />CL <br />J <br />LO <br />r" <br />T <br />U) <br />N <br />m <br />LO <br />L01 <br />M <br />ch <br />LL 04 <br />O <br />L0 <br />a) N <br />LO <br />CV <br />Q <br />j <br />T <br />E <br />Z <br />CM 1 <br />0 <br />c <br />E <br />B 6 <br />a <br />U <br />Q O <br />JOB <br />NO: <br />23-00524 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />