11 <br />i� <br />PR <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4"-1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 000 <br />5-0" <br />STUB -OUT FOR lir <br />0 1'-O" G 9 <br />GAS METER o <br />(V = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-51' <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" 16" O.C. <br />19'-311 <br />1 SIMPSON HTS20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />814" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />16-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />,Hood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />FILL CELL <br />w <br />CONT. #5 > STD. 90° <br />BAR HOOK <br />STD. 900 HOOK <br />BOND BEAM <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. GIRDER TRUSS <br />CONT. #5 <br />�i_ <br />BAR 2X TOP PLATE <br />5/8"0 <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN , <br />� <br />SEE PLAN FOR REQ'D - <br />PLYWOOD FLOOR <br />SHEATHING PER PLAN <br />COLUMNAND - <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKINGrrJI <br />� <br />7 �� <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />I � ` <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />i . ) Small gap 2" min. <br />2 18 min. <br />a 4 max. Web Stiffener Fastener Schedule <br />1/8" gap <br />I I Joist Bearing Location <br />'1 V Series I Depth I End Intermediate <br />r / ,i 1 ;f� ® 9-1/2" , 2-8d 2-8d - <br />BCI 3-8d <br />— 14" 2-8d L _ - <br />Clinch nails — r� , <br />s 1-7/ ' - d <br />when possible BCI 6500s® 914 8" 2-8-d 2-8d <br />I 3-8d <br />Po 5-8d - <br />-- <br />1) Support back of web during nailing to prevent damage to -- - 11 -7/7/ 2-8d 6-8d - <br />8" 2-8d 3-8d <br />web -flange connection. BCI 60s® 14" _ 2-8d 5-8d <br />2) Block solid between joists for full length of span. Tight fit --- 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-7/8" 3-16d 3-16d _ <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s® 14" 5-16d 5-16d <br />4 Place joists together and nail from each side with 2 rows of 10d nails —+- <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT ) at 12" o.c., cliched when possible. Stagger rows from opposite required when indicated or 4" max. 16" 6-16d 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING Ys" GAP TOP sides b 6". - Hangers with side nailing. <br />@ Y -Hangers with sides not containing WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION top irdsmouthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />i116 <br />code for appropriate <br />Zor--20 <br />details in <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />Provide adequate bearing <br />for each lapped joist. <br />Squash block 10d nails SECTION INT. BRIG. WALL <br />(2x4 minimum) @ <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />rw nvLw (r=.n'.r.r r MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max, along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Use 10dxY nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />■ <br />• <br />"61 A 1 2" ROUND HOLE MAY 6' 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1}Z" <br />1•:;�'k+a"dR�`"�o.F w ^Y"" N,..:�, "Y +4 JA 4x <br />,..c ..,w. t;���; <br />F.r ?ar-. 'p'fcn �'31' hrs'+ryl, P �, <br />�$.. .,,s__ �.C.���:".+..�{..L.�.t� �"r�i^L <br />(� P; <br />7_.,�. if <br />}x. ,y,�y{,�U, -, <br />�vi�✓.a .4:, <br />5' day- <br />w� <br />r�+�•ssk':�.r�".i?•.:d'��19FzF�,�v4�^'rhec��..v�'Lry <br />�; �.e7 .T Y 2 <br />�,�;�i.� <br />��fY� K`.'�I!'(! <br />t� <br />- ?L <br />�.. .tip-��S <br />z� <br />P•.+"pp� f,.p'r'"� <br />.t'g}iN:_,:,`��, <br />'><1!•7' <br />.��' <br />T <br />.,.:.�..� <br />"�i't <br />F,'17�. <br />«w S� +� t-n,;.. <br />r-C.. .. .t ., �b <br />t w L <br />,+,11 �J��': <br />t� �&y, <br />Mtr, <br />77r <br />���1�...ri <br />cb � <br />•.^N, n <br />�'.�u>.7fir:, <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />'_-,.Install tight to.top flange. <br />-L' \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />r 1/4"-2" gap f <br />- � Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />e <br />requirements <br />0.6 X Joist <br />depth <br />� � <br />I -JOISTS BUCKETS <br />N.T.S. <br />1.0 <br />SIMPS( <br />w/(22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />-UP COLUMN DETAIL <br />BUILT <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A!C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM—/ • <br />' e <br />SEE PLAN FOR •• a . • <br />FOUNDATION INFO ' • 4 <br />STEM FOUNDATION <br />GRADE <br />0 <br />d 4 <br />Q <br />REINF. SEE PLAN <br />1 (2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />o LOCATION OF <br />° SECOND H10A <br />SIMPSON H10A • ° °° (WHEN <br />! 18 10d 1 1/2" ° REQUIRED) <br />w( ) x <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0 <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />r%lMf— 1, )1-11T1P% A 1 TI 1r%1 1 1—\ 111 <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />c 4 <br />v° e <br />Z • C • <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />a <br />N <br />SEE FND, PLN. <br />SIZE & REINF. <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />4Q <br />4/ ev L <br />\ <br />, <br />a <br />s►r 0 <br />1:' o •= <br />N W <br />:E cm <br />a� a <br />4 c cec�N <br />H A C, <br />4f O JO <br />Q N Y <br />°: W" d <br />E "- c <br />co a <br />cc <br />a a <br />w <br />E <br />A o <br />d. U <br />a <br />11 <br />'0,11`6R0'wN �Z''`�. <br />• •C``4 s '. <br />V <br />r, "\O pF <br />;=. F LOB <br />Q•' <br />O•t, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resldengal 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />FW- S g <br />a S <br />v do 8 <br />� <br />s i LL <br />J <br />y LL CIL W <br />fv- a Y <br />WG�00 <br />g m W <br />W 's <br />Z ILN CV Z d l- <br />IL <br />z <br />W ❑ ❑ <br />z� <br />z <br />G F• <br />Q <br />;EQ) <br />TM <br />C1 <br />�D <br />Tr <br />N <br />w\ <br />� <br />V _ <br />�O <br />Ul <br />�N <br />w <br />' <br />8 <br />= <br />Q N ODoil. <br />o <br />N q <br />z <br />= <br />E <br />a <br />!— <br />g E <br />s� <br />oa <br />0o <br />o <br />°� <br />Y <br />az <br />WO <br />o <br />a:� <br />C <br />H8 <br />m$ <br />z� <br />Z <br />� <br />� J <br />ism <br />rz <br />z <br />3 <br />8 <br />W <br />�3 <br />4w <br />it <br />W <br />k <br />`cY <br />O� <br />ofl <br />LO <br />a <br />LO <br />co <br />0 <br />7 <br />LO <br />T' <br />m <br />0° <br />Li) <br />'�`/?� <br />4-1U) <br />rn <br />0) <br />L I <br />.0 ca <br />C) <br />M N <br />L.ci <br />LO <br />N <br />Q cV <br />T_ <br />� <br />M <br />o <br />m <br />z <br />E O <br />M <br />a <br />E <br />Cg J Q p <br />c <br />JOB <br />NO: 23-0052; <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />