Q <br />to <br />N <br />to <br />N <br />i <br />Q <br />h <br />N <br />to <br />2 <br />rh <br />N <br />N <br />3 <br />Q <br />c <br />F— <br />Q <br />N <br />N <br />ii <br />c <br />i <br />a <br />04 <br />N <br />c <br />M <br />0 <br />N <br />S <br />9 <br />A <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed In accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits In all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315,1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired Into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle Installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />FE7W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I Ph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />k& <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />_T4, <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />0 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />n <br />200 amp <br />150 amp <br />UNDERGROUND [Dis <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING Q <br />TERMINATION PER 71 <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />t to lights & outlets <br />to appliances and GFI <br />to WH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17. 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE \ <br />OWNERS <br />SUITE <br />I I I <br />ROUGH -IN FOR <br />-- I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />II '\\ 12 <br />X— I <br />II G <br />LOFT <br />I / <br />I <br />S.Ddh <br />db <br />C`pFl <br />LAIN. <br />1 p 6 _ I ROUGH -IN FOR <br />1 C.M ( OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />F I I- 12 <br />'O -B - I a I �P-�-' <br />���--=—� 1 BE OM 2 <br />LIGHT & SW <br />IN ATTIC <br />I <br />I H <br />VP FI o <br />— — — — — — — — — — - <br />I <br />GFI <br />( ' / S.D }� , ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />-- `, <br />OPT. CLG. FAN/ <br />ROUGH -IN FOR / � I I LIGHT PRE -WIRE <br />i 2 <br />1 LIGHT PRE-WIRL� <br />I j II <br />W.I.C. <br />BEDROOM 3 <br />I , BEDROOM 4 <br />t------ -----j VP �► ,. <br />RECEPT. <br />FOR ALARM <br />SYSTEM - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4"=1'-0" <br />M <br />Al <br />CM <br />N <br />m -o <br />C2 LL' <br />u c� o <br />W U N <br />C <br />H to O <br />N W O m <br />m <br />•� E c <br />s <br />n� 3y .au sc <br />yr� <br />V1 <br />CM <br />N <br />O <br />N <br />N <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages beating <br />Engineer's signature and seal. <br />M <br />N <br />/ <br />v <br />Ow <br />grd <br />�NO� <br />di <br />Q <br />% <br />01 N �? J <br />G -r LL W <br />I� <br />Z <br />JLLLL SS a <br />N C O1 d <br />Z <br />IL <br />MZ J J <br />Z <br />N Q O <br />OU 0 <br />W <br />y <br />00 <br />� <br />N <br />z C) <br />z <br />Q <br />Aram <br />�V <br />O <br />C <br />® <br />u <br />LL, <br />Q <br />�0 <br />. <br />` <br />z <br />E <br />zo <br />Wo <br />r� <br />¢Iz <br />0 <br />E <br />N U <br />ti <br />z® <br />W¢ <br />f- <br />0 <br />E <br />fo <br />IV0 <br />UG <br />Z <br />�, � <br />IV Qo <br />gW <br />C: <br />a o <br />U <br />y0 <br />m <br />'o Fr <br />Z <br />� <br />� <br />>L <br />o <br />a <br />W <br />�� <br />LL <br />o <br />J <br />o <br />C�> <br />> <br />LO <br />L <br />m <br />Q <br />CD <br />~ <br />c <br />j t <br />LO <br />Y <br />� <br />r <br />- <br />Cn <br />cc <br />LO <br />LOI <br />Lo co <br />O <br />LC) <br />0 N <br />LO <br />CV <br />Q <br />j <br />E <br />m <br />C <br />� <br />M <br />� <br />Z <br />0 <br />Iu ci <br />a <br />v _j <br />¢ o <br />_°i <br />JOB <br />NO : <br />23-00524 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.2 <br />