Laserfiche WebLink
N01a) <br />z_- <br />SIMPSON MASONRY <br />HANGER MBHA3.12/9.25 <br />:,,_," <br />T1 (T2) <br />TRUSS GIRDER PROFILES <br />1/4"=1'-0" <br />" <br />6 <br />I <br />i� <br />12'-0" A.F.F. j. <br />TOP OF CMU <br />T3 <br />TRUSS DIAGRAMS SHOWN FOR <br />THE PURPOSE OF DESCRIBING <br />TRUSS PROFILES ONLY <br />C2 SYMBOL TAG CONNECTOR SCHEDULE <br />CONNECTORS <br />MODELS <br />DESCRIPTION <br />LOCATION <br />SPACING <br />FASTENERS <br />ALLOWABLE UPLIFT <br />LBS <br />FLORIDA PRODUCT <br />APPROVAL FL <br />C1 <br />HETA20 <br />EMBEDDED TRUSS ANCHOR <br />TRUSS OR FIAT GIRDER TO BOND BM <br />24" <br />TRUSS 10-10d x 1-1/2 <br />1,810 <br />FL 1901.16 <br />C2 <br />HTT22 <br />TENSION TIE <br />HIP GIRDER TO BOND BEAM <br />--- <br />HIP GIRDER 16-16d SINKERS, FLAT GIRDER 16-16d SINKERS <br />5,250 <br />FL 503.21 <br />C3 <br />(2) H2.5A <br />HURRICANE TIE <br />ROOF TRUSS TO FLAT GIRDER <br />24" <br />TRUSS 5-8d, GIRDER 5-8d (EACH TIE) <br />1.200 <br />FL 503.5 <br />C4 <br />(2) HTS16 <br />GIRDER TIEDOWN <br />HIP GIRDER TO FLAT GIRDER <br />--- <br />HIP GIRDER 8-10d, FLAT GIRDER 8-10d <br />2.520 <br />FL 538.1 <br />C5 <br />(1) H2.5A <br />HURRICANE TIE <br />ROOF TRUSS TO FLAT GIRDER <br />24" <br />TRUSS 5-8d, GIRDER 5-8d <br />600 <br />FL 503.21 <br />C6 <br />(2) HTS24 <br />STRAP TIE <br />FLAT GIRDER TO POST <br />--- <br />GIRDER 10-10d, POST 10-10d (EACH STRAP) <br />2,900 <br />FL 538.3 <br />C7 <br />(1) HTS24 <br />STRAP TIE <br />FLAT GIRDER TO POST <br />--- <br />GIRDER 10-10d, POST 10-10d (EACH STRAP) <br />1,450 <br />FL 538.3 <br />C8 <br />ABU66 <br />POST BASE <br />POST TO SLAB <br />--- <br />SLAB 5/8" A.B., POST 12-16d <br />2,300 <br />FL 1725.1 <br />C9 <br />N/A <br />STEEL ANCHOR BOLT <br />POST TO CONCRETE (SLAB) CURB <br />--- <br />(4) 5/8" ANCHOR BOLTS (SEE DETAIL ON SHEET A3) <br />* 2,974 <br />--- <br />C1O <br />(1) H2.5A <br />HURRICANE TIE <br />ROOF TRUSS TO DBL TOP PLATE <br />24" <br />TRUSS 5-8d, PLATE 5-8d <br />600 <br />FL 503.5 <br />C11 <br />SP1 <br />STUD PLATE TIE <br />STUD BOTTOM PLATE <br />16" <br />STUD 6-10d, PLATE 4-10d <br />585 <br />FL 474.312 <br />C12 <br />SP2 <br />STUD PLATE TIE <br />STUD TO DBL TOP PLATE <br />16" <br />STUD 6-10d, PLATE 4-10d <br />585 <br />FL 474.313 <br />C13 <br />MBHA3.12/9.25 <br />MASONRY HANGER <br />FLAT GIRDER TO WALL BOND BEAM <br />--- <br />TOP & FACE 1-ATR 3/4", GIRDER 18-10d <br />3,145 <br />FL 538.3 <br />C14 <br />N/A <br />STEEL ANCHOR BOLT <br />FLAT GIRDER TO POST CAP <br />--- <br />(3) 1/2" ANCHOR BOLTS (SEE DETAIL ON SHEET A3) <br />* 2,974 <br />--- <br />CONNECTOR NOTES: <br />1. ALL CONNECTORS BY SIMPSON STRONG -TIE. NO SUBSTITUTIONS UNLESS APPROVED BY THE ARCHITECT. <br />2. NOTIFY ARCHITECT IF ANY UPLIFT LOADS SHOWN ON THE TRUSS MANUFACTURER'S SHOP DRAWINGS ARE GREATER THAN THE ALLOWABLE LOADS FOR THE APPLICABLE CONNECTORS LISTED ABOVE. <br />3. SET ANCHOR BOLTS WITH SIMPSON EPDXY ADHESIVE. <br />4. INSTALL ALL CONNECTORS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />4 CALCULATED UPLIFT <br />h <br />I <br />C2 <br />N <br />N <br />c9 El L <br />C3 <br />1 <br />h <br />0 <br />I <br />L <br />I <br />I <br />I <br />I <br />I <br />35'-8" <br />1IL/ <br />W <br />of <br />�I <br />I <br />...... <br />.......................................................................................................................................................................................................................................................................................................................... <br />Jil <br />.......... 1 <br />I <br />I <br />� I~ <br />32'-5" <br />C2 I <br />I <br />. ...................... ................................................................................ <br />/ ...................... ... ............. .................................................................................................................................................................. <br />b0ommolimmomm■ <br />L1 1 <br />i <br />I <br />I <br />I <br />I <br />I <br />I, <br />rPLUMB HEIGHT <br />1 <br />VERIFY 1'-21, I, <br />C4 <br />C3 <br />C3 <br />IC91C141 <br />IC9IC141 <br />12' <br />N <br />W <br />Ln <br />N <br />z <br />O <br />O <br />v <br />6'-11" <br />VERIFY <br />1 <br />A8 <br />12 <br />6 <br />TRUSS FABRICATOR SHALL COORDINATE ALL <br />TRUSSES AND GIRDERS WITH WALL AND BUILDING <br />SECTIONS (SEE SHEETS A9, Al AND A11) <br />58'-0" <br />T6 <br />4'-11" <br />10" <br />N 12'-0" A.F.F. <br />TOP OF CMU <br />� T5 <br />SHALL BE DESIGNED IN ACCORDANCE WITH APPLICABLE PROVISIONS OF THE "NATIONAL DESIGN <br />SPECIFICATION FOR WOOD CONSTRUCTION" OF NFPA AND WITH THE TPI "DESIGN SPECIFICATION <br />FOR METAL PLATE CONNECTED WOOD TRUSSES". CORD MEMBERS SHALL BE KILN DRIED <br />SOUTHERN PINE, NO. 2 MINIMUM. LIVE LOAD DEFLECTION SHALL BE LIMITED TO 1/360. <br />CONNECTOR PLATES SHALL BE MADE OF ASTM A446, GRAD A, HOT -DIPPED GALVANIZED (G60) <br />STEEL AND APPLIED TO BOTH FACES OF TRUSS AT EACH JOINT. <br />ROOF TRUSS SUPPLIER SHALL BE RESPONSIBLE FOR THE DESIGN OF THE ROOF TRUSSES, <br />FLOOR TRUSSES OR I -JOISTS AND ALL SUPPORTING LAMINATED BEAMS IF APPLICABLE. DESIGN <br />OF THE SYSTEM SHALL BE PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED <br />ENGINEER FOR THE SPECIFIED LIVE AND DEAD LOADS AND UPLIFT LOADS TO RESIST THE <br />FORCES DUE TO THE APPROPRIATE WIND ZONE. <br />ALL REQUIRED PERMANENT AND TEMPORARY TRUSS BRACING SHALL BE INDICATED ON THE <br />MANUFACTURER'S SHOP DRAWINGS, SHOWING REQUIRED SIZES AND CONNECTIONS. <br />THE NET UPLIFT, REACTIONS AND HORIZONTAL LOADS FOR EACH TRUSS SHALL BE INDICATED <br />ON THE TRUSS DRAWINGS. TRUSS CONNECTORS SHALL BE BY THE TRUSS VENDOR. <br />ROOF SHEATHING <br />SHEATHING SHALL BE A MINIMUM OF 5/8" THICK, 32/16 CDX PLYWOOD LAID IN A STAGGERED <br />PATTERN AS SHOWN IN THE FBC TABLE 2310.2A, CASE 1. USE PANEL CLIPS BETWEEN EACH <br />SUPPORT. <br />NAILING PATTERN SHALL BE 8d NAILS AT 6' ON CENTER AT ALL PANEL EDGES AND 12" ON CENTER <br />IN THE INTERIOR OF THE PANEL, EXCEPT THAT WITHIN 4' OF OVERHANGS, GABLE ENDS AND HIP <br />RIDGES, THE SPACING AT EDGES SHALL BE 4" ON CENTER AND 6" ON INTERIOR AREAS. <br />STRUCTURAL WOOD <br />LUMBER FOR STRUCTURAL FRAMING SHALL BE SURFACED AT 19 <br />SOUTHERN PINE MEETING OR EXCEEDING THE FOLLOWING GRADES: <br />INTERIOR NON -LOAD BEARING SPRUCE -PINE -FIR, STUD GRADE, Fb 675, E 1.2 <br />EXTERIOR LOAD -BEARING YELLOW SOUTHER PINE, NO. 2 GRADE,19% MC MAX., KD, <br />MIN. Fb 1,200 PSI, E 1.6, G>0.49 <br />ML=MICROLLAM BEAMS E1.9, Fb 2,600 psi, Fv185 <br />FRAMING CONNECTORS <br />ALL FRAMING CONNECTORS ARE BASED ON SIMPSON STRONG -TIE LUMBER CONNECTORS <br />AND NAILING REQUIREMENT LITERATURE. NO MANUFACTURER SUBSTITUTIONS ALLOWED <br />UNLESS APPROVED BY THE ARCHITECT. ALL NAILS AND CONNECTORS EXPOSED TO THE <br />ATMOSPHERE SHALL BE GALVANIZED. ALL CONNECTORS SHALL BE CERTIFIED CODE <br />APPROVED. <br />GENERAL NOTE <br />RAFTERS, CEILING JOISTS, COLLAR TIES, BEAMS, GIRDERS, PURLINS AND COLUMNS SHALL <br />BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (LATEST ADOPTED <br />EDITION) OR LOCAL CODES IF MORE RESTRICTIVE. <br />2 � (�) 1/4 <br />DRIVE-THRU PLAN <br />A9 <br />46'-1j' <br />I <br />C1 <br />k <br />U <br />I <br />12'-0" A.F.F. <br />TOP OF CMU <br />1'-2" VERIFY <br />RECESSED F=FILLED WITH GROUT <br />U=UNFILLED <br />QUANTITY #5 <br />FREBAR AT TOP <br />8IRF16-1B/1T <br />NOMINAL WIDTH J QUANTITY #5 <br />NOMINAL HEIGHT REBAR AT BOTTOM <br />wwm=�= m <br />40 <br />G SYMBOL LINTEL SCHEDULE <br />NUMBER <br />TYPE <br />CONST. <br />LENGTH <br />FILLED/UNFILLED <br />REINFORCEMENT <br />MAX. GRAVITY <br />LOAD PLF <br />REMARKS <br />L1 <br />8F32 <br />COMPOSIT <br />148" <br />FILLED <br />1/T-1/B <br />2,883 <br />L2 <br />8F8 <br />SINGLE <br />64 <br />FILLED <br />0/1-1/B <br />1,663 <br />L3 <br />8F8 <br />SINGLE <br />64" <br />FILLED <br />O/T-1 B <br />1,663 <br />L4 <br />BUB <br />SINGLE <br />64 <br />UNFILLED <br />0 -0 B <br />1,217 <br />L5 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />O/T-0 B <br />1,217 <br />L6 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />O/T-O/B <br />1,217 <br />L7 <br />8F16 <br />COMPOSITE <br />148" <br />FILLED <br />1/T-1/B <br />1,075 <br />1 <br />L8 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />0 -0 B <br />1,217 <br />L9 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />0 -0 B <br />1,217 <br />L10 <br />8F32 <br />COMPOSITE <br />196 <br />FILLED <br />1/T-1/B <br />2,513 <br />L11 <br />8U8 <br />SINGLE <br />40" <br />UNFILLED <br />O/T-0 B <br />2,231 <br />L12 <br />8F8 <br />SINGLE <br />64m <br />FILLED <br />0 -1/B <br />1,663 <br />L13 <br />8U8 <br />SINGLE <br />64 <br />UNFILLED <br />O/T-0/B <br />1,217 <br />L14 <br />81.18 <br />SINGLE <br />64 <br />UNFILLED <br />0 -O/B <br />1,217 <br />L15 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />O/T-0/B <br />1,217 <br />L16 <br />8F16 <br />COMPOSITE <br />148" <br />FILLED <br />1 -1/B <br />1,075 <br />1 <br />L17 <br />81.18 <br />SINGLE <br />64" <br />UNFILLED <br />O/T-0/B <br />1,217 <br />L18 <br />8U8 <br />SINGLE <br />64" <br />UNFILLED <br />O/T-0/B <br />1,217 <br />L19 <br />81.18 <br />SINGLE <br />64 ipUNFILLED <br />O/T-0/B <br />1,217 <br />L20 <br />8178 <br />SINGLE <br />64" <br />FILLED <br />O/T-1/B <br />1,663 <br />L21 <br />8178 <br />SINGLE <br />64" <br />FILLED <br />O/T-1/B <br />1,663 <br />9'-0" 1'-2" <br />CORNER JACKS <br />C2 Cl TYPICAL <br />OVERHANG <br />N <br />I <br />L12 L13 I <br />I N <br />I a <br />En <br />�a <br />ALL NM RESERVED <br />CORDA R TES ARCHRECTS ©2u cwmGH f <br />REVISIONS <br />1 <br />8/13/08 <br />4. <br />J <br />�•I <br />o <br />V <br />cn _o <br />a <br />0 <br />oWw <br />H <br />W <br />H <br />� w <br />W <br />O <br />N <br />0 <br />wcn <br />E--"1 I <br />rn <br />I <br />�..� 'o <br />04 <br />P400 <br />00 <br />Ln <br />wto <br />J <br />�..� 13 <br />J <br />O• <br />cn <br />Lij <br />U <br />w <br />Z <br />W <br />�a <br />N <br />N <br />Q <br />DATE. <br />5/30/08 <br />SCALE: <br />AS NOTED <br />JOB NO.: <br />I SHEET. <br />27013 <br />A17 <br />OF <br />22 <br />SHEETS <br />