1 2 3 4 5 6 7 8 9 10 1 11 12 13 14 <br />1�1 <br />M <br />L <br />K <br />J <br />H <br />G <br />E <br />D � <br />1 <br />1 <br />1 <br />1 <br />1 <br />4 <br />1 <br />1 <br />1 <br />1 <br />C j <br />1 <br />1 <br />A1 <br />AC <br />AIR CONDITIONING <br />AD <br />ACCESS DOOR <br />AFF <br />ABOVE FINISHED FLOOR <br />AHU <br />AIR HANDLING UNIT <br />AP <br />ACCESS PANEL <br />BFF <br />BELOW FINISHED FLOOR <br />BHP <br />BRAKE HORSE POWER <br />BOT <br />BOTTOM <br />BTUH <br />BRITISH THERMAL UNIT PER HOUR <br />CC <br />COOLING COIL <br />CD <br />CONDENSATE DRAIN <br />CFM <br />CUBIC FEET PER MINUTE <br />CLG <br />CEILING <br />CU <br />CONDENSING UNIT <br />DB <br />DRY BULB <br />DG <br />DOOR GRILLE <br />DP <br />DEW POINT <br />DX <br />DIRECT EXPANSION <br />EA <br />EXHAUST AIR <br />EAT <br />ENTERING AIR TEMPERATURE <br />EDH <br />ELECTRIC DUCT HEATER <br />EER <br />ENERGY EFFICIENCY RATIO <br />EF <br />EXHAUST FAN <br />EL <br />ELEVATION <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />ESP <br />EXTERNAL STATIC PRESSURE <br />FCU <br />FAN COIL UNIT <br />FD <br />FLOOR DRAIN <br />FL <br />FLOOR <br />FM <br />FACTORY MUTUAL <br />FPI <br />FINS PER INCH <br />FPF <br />FINS PER FOOT <br />FPM <br />FEET PER MINUTE <br />FSD <br />FIRE/SMOKE DAMPER <br />G <br />NATURAL GAS <br />GPH <br />GALLONS PER HOUR <br />GPM <br />GALLONS PER MINUTE <br />H <br />HUMIDITY <br />HC <br />HEATING COIL <br />HP <br />HORSE POWER <br />HVU <br />HEATING AND VENTILATING UNIT <br />KW <br />KILOWATT <br />LAT <br />LEAVING AIR TEMPERATURE <br />LRA <br />LOCKED ROTOR AMPS <br />LWT <br />LEAVING WATER TEMPERATURE <br />MAX <br />MAXIMUM <br />MIN <br />MINIMUM <br />NC <br />NORMALLY CLOSED <br />NIC <br />NOT IN CONTRACT <br />NO <br />NORMALLY OPEN <br />PD <br />PRESSURE DROP <br />PRESS <br />PRESSURE <br />RA <br />RETURN AIR <br />RG <br />REFRIGERANT <br />RLA <br />RUNNING LOAD AMPS <br />RPM <br />REVOLUTIONS PER MINUTE <br />RTU <br />ROOF TOP UNIT <br />SO <br />SMOKE DETECTOR <br />SA <br />SUPPLY AIR <br />SP <br />STATIC PRESSURE <br />STRUCT <br />STRUCTURAL <br />SYS <br />SYSTEM <br />T <br />TEMPERATURE <br />TSP <br />TOTAL STATIC PRESSURE <br />TYP <br />TYPICAL <br />UC <br />UNDERCUT <br />UG <br />UNDERGROUND <br />UL <br />UNDERWRITERS LABORATORY <br />LION <br />UNLESS OTHERWISE NOTED <br />UV <br />UNIT VENTILATOR <br />VD <br />VOLUME DAMPER <br />WB <br />WET BULB <br />PIPING <br />2----------t <br />2 C-D----2 <br />PIPING TO BE REMOVED <br />EXISTING PIPING TO REMAIN <br />CONDENSATE LINE <br />REFRIGERANT PIPING <br />DOMESTIC WATER <br />GATE VALVE <br />GLOBE VALVE <br />CHECK VALVE <br />BALL VALVE <br />PLUG VALVE <br />BUTTERFLY VALVE <br />PRESSURE REDUCING VALVE <br />SAFETY OR PRESSURE RELIEF VALVE <br />VALVE IN RISER <br />DIRECTION OF FLOW <br />REDUCER OR INCREASER <br />ECCENTRIC REDUCER <br />TOP CONNECTION, 45 OR 90 DEG. <br />BOTTOM CONNECTION, 45 OR 90 DEG. <br />SIDE CONNECTION <br />CAPPED OUTLET <br />DROP IN PIPING <br />RISE IN PIPING <br />UNION <br />SOLENOID VALVE <br />ANGLE GLOBE VALVE <br />FLEXIBLE CONNECTION <br />PRESSURE GAUGE <br />STRAINER WITH BALL VALVE <br />EXPANSION JOINT <br />SYSTEM SUMMARY <br />HVAC DESIGN PARAMETERS <br />CITY <br />SUMMER DESIGN <br />OUTDOOR <br />SUMMER DESIGN <br />INDOOR <br />WINTER DESIGN <br />OUTDOOR <br />WINTER DESIGN <br />INDOOR <br />TAMPA <br />97F / 77F <br />75-F / 507.RH <br />36*F <br />72*F <br />BUILDING <br />U-VALUE <br />GLASS <br />U-VALUE <br />SYSTEM <br />VENTILATION RATE <br />AS PER ASHRAE 62n 2001 <br />FILTRATION CRITERIA <br />AS PER ASHRAE 52-76 <br />AHU-1 <br />* <br />1'-30% EFF <br />ROOF = - <br />WALL = - <br />GLASS = 1.04 <br />SC = 0.95 <br />SYSTEM OCCUPANCY <br />DESIGN NOTES: <br />* NO OUTSIDE AIR VENTILATION <br />REQUIRED (RESIDENCE) <br />SYSTEM <br /># OF PEOPLE <br />OUTSIDE AIR <br />(CFM) <br />TYPE OF <br />OCCUPANCY <br />AHU-1 <br />- <br />- <br />RESIDENCE <br />® UP kxy DN <br />® UP DN <br />® UP L_� DN <br />DUCTWORK <br />SUPPLY DUCT (UP & DOWN) <br />EXHAUST DUCT (UP & DOWN) <br />RETURN AIR DUCT (UP & DOWN) <br />CEILING DIFFUSERS/GRILLES (DOUBLE LINE) <br />CEILING DIFFUSERS/GRILLES (SINGLE LINE) <br />SIDE WALL REGISTER OR GRILLE (DOUBLE LINE) <br />SIDE WALL REGISTER OR GRILLE (SINGLE LINE) <br />NEW DUCT - WIDTH x DEPTH (DOUBLE LINE) <br />NEW DUCT - WIDTH x DEPTH (SINGLE LINE) <br />EXISTING DUCT TO REMAIN (DOUBLE LINE) <br />EXISTING DUCT TO REMAIN (SINGLE LINE) <br />EXISTING DUCT TO BE REMOVED (DOUBLE LINE) <br />EXISTING DUCT TO BE REMOVED (SINGLE LINE) <br />FLEXIBLE DUCTWORK (INSULATED) <br />DUCT TRANSITION - CONCENTRIC (DOUBLE LINE) <br />DUCT TRANSITION - CONCENTRIC (SINGLE LINE) <br />DUCT TRANSITION - ECCENTRIC (DOUBLE LINE) <br />DUCT TRANSITION - ECCENTRIC (SINGLE LINE) <br />DUCT TRANSITION - RECT. TO RND (DOUBLE LINE) <br />DUCT TRANSITION - RECT. TO RND (SINGLE LINE) <br />MANUAL VOLUME DAMPER (DOUBLE LINE) <br />MANUAL VOLUME DAMPER (SINGLE LINE) <br />BACK DRAFT DAMPER <br />INCLINED RISE, IN DIRECTION OF AIR FLOW (DOUBLE LINE) <br />INCLINED RISE, IN DIRECTION OF AIR FLOW (SINGLE LINE) <br />INCLINED DROP, IN DIRECTION OF AIR FLOW (DOUBLE LINE) <br />INCLINED DROP, IN DIRECTION OF AIR FLOW (SINGLE LINE) <br />FLEXIBLE CONNECTION (DOUBLE LINE) <br />FLEXIBLE CONNECTION (SINGLE LINE) <br />SLEEVE FOR PENETRATION THROUGH A FIRE RATED <br />PARTITION WAIT <br />DUCT MOUNTED COIL/HEATER (DOUBLE LINE) <br />DUCT MOUNTED COIL/HEATER (SINGLE LINE) <br />VANED ELBOW (PROVIDE ALL SQUARE OR RECTANGULAR <br />ELBOWS WITH TURNING VANES EVEN IF SYMBOL IS MISSING) <br />VANED RADIUS ELBOW (PROVIDE ALL SQUARE OR <br />RECTANGULAR ELBOWS WITH TURNING VANES EVEN IF <br />SYMBOL IS MISSING) <br />ACOUSTICALLY LINED DUCT <br />VANE TURN ELBOW & AIR SPLIT TYPE DUCT TAKE -OFF <br />(DOUBLE LINE) <br />--2 <br />VANE TURN ELBOW & AIR SPLIT TYPE DUCT TAKE -OFF <br />(SINGLE LINE) <br />AIR FLOW CFM <br />1 q <br />6 O TYP. <br />AIR DEVICE TYPE (EX = Existing) <br />AIR DEVICE NECK SIZE <br />(D <br />THERMOSTAT / TEMPERATURE SENSOR <br />0 <br />HUMIDISTAT / HUMIDITY SENSOR <br />A <br />AIR DEVICE TYPE (EX = Existing) <br />-& ---DOOR GRILLE (18"x12" U.O.N.) <br />AIR DEVICE SIZE <br />-{ 0 <br />DOOR FLOWCFM <br />(1" U.O.N.) <br />l EXHAUST FAN <br />AIR DEVICES <br />2-WAY AIR FLOW 4-WAY AIR FLOW <br />1-WAY AIR FLOW 3-WAY AIR FLOW <br />FLEX DUCT <br />0 - <br />100 <br />CFM = <br />6"0 <br />101 - <br />160 <br />CFM = <br />7"0 <br />161 - <br />200 <br />CFM = <br />8'0 <br />201 - <br />325 <br />CFM = <br />10"0 <br />326 - <br />400 <br />CFM = <br />12"0 <br />401 - <br />640 <br />CFM = <br />WO <br />641 - <br />700 <br />CFM = <br />16"0 <br />DRAWING SYMBOLS <br />1 SECTION NUMBER <br />2 3 DRAWING NUMBER WHERE DRAWN <br />DRAWING NUMBER WHERE CUT <br />POINT OF DEMOLITION <br />POINT OF NEW CONNECTION <br />�-► POINT OF INTERFACE BETWEEN CONTRACTORS <br />® KEYED NOTES <br />SPECIFICATIONS <br />1.0 BASIC MATERIAL AND METHODS <br />1.1 ,SCOPE OF WORK <br />PROVIDE LABOR AND MATERIALS AS REQUIRED TO PROVIDE A FULLY FUNCTIONING AND COMPLETE SYSTEM AS INDICATED <br />ON DRAWINGS. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF <br />SYSTEMS AND EQUIPMENT. FINAL LOCATIONS OF EQUIPMENT SHALL BE FIELD DETERMINED. ALL DISCREPANCIES ON <br />DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO SUBMISSION OF BIDS. <br />1.2 GENERAL AND SPECIAL CONDITIONS <br />ALL DIVISION 1 SPECIFICATIONS AND ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS OUTLINED IN THE CONTRACT <br />DOCUMENTS APPLY TO MECHANICAL SYSTEMS. ADDITIONALLY, WORK SHALL COMPLY WITH FLORIDA BUILDING CODE <br />(2004 WITH 2O05 REVISIONS), ORDINANCES AND REGULATIONS OF THE LOCAL AUTHORITY HAVING JURISDICTION, <br />NATIONAL FIRE PROTECTION ASSOCIATION AND NAT04AL ELECTRICAL CODE. ALL EQUIPMENT SHALL CARRY THE <br />UNDERWRITER'S LABORATORIES (UL) SEAL WHERE APPLICABLE. <br />1.3 QUALITY CONTROL <br />UNLESS OTHERWISE NOTED, PROVIDE NEW MATTERIALS FREE OF DEFECTS, WHERE NO SPECIFIC WEIGHTS OR GRADES ARE <br />SPECIFIED PROVIDE MATERIALS OF AN ACCEPTED STANDARD WEIGHT AND GRADE ACCORDING TO CODE AND GOVERNING <br />STANDARDS BY ASHRAE, SMACK NFPA AND UL INSTALL ALL EQUIPMENT, PIPING, DUCTWORK AND CONTROLS IN <br />ACCORDANCE WITH CODES, GOVERNING STANDARDS, AND MANUFACTURER'S RECOMMENDATIONS. <br />FIRE PERFORMANCE CHARACTERISTICS OF INSTALLED MATERIALS SHALL BE RATED IN ACCORDANCE WITH ASTM E84. <br />MAXIMUM SMOKE DEVELOPED RATING SHALL BE 50. <br />SUPPLIED EQUIPMENT SHALL BE AS SCHEDULED OR OWNER APPROVED EQUAL IN QUALITY AND PERFORMANCE. <br />1.4 COORDINATION <br />COORDINATE ALL WORK FOR PROPER LOCATION, POWER, AND UTILITY REQUIREMENTS. SCHEDULE INSTALLATIONS TO <br />AVOID CONFLICT AMONG TRADES. ADDITIONS TO THE CONTRACT FOR COORDINATION AMONG TRADES WILL NOT BE <br />ALLOWED. <br />1.5 PENETRATIONS, CUTTING AND PATCHING <br />SEAL. ALL PIPING AND DUCT PENETRATIONS OF WALLS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS AND <br />SPECIFICATIONS. FLASH ALL ROOF AND WALL PENETRATIONS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS. <br />PROVIDE FIRE DAMPERS AT ALL RATED PENETRATIONS. <br />1.6 HERS AND SUPPORTS <br />PROVIDE HANGERS AND SUPPORTS FOR ALL PIPING, DUCTWORK AND EQUIPMENT IN ACCORDANCE WITH SMACNA, MSS, <br />ASME AND ASHRAE STANDARDS. SUPPORT ALL ITEMS FROM INTEGRAL BUILDING STRUCTURAL MEMBERS. DO NOT <br />HANG ITEMS FROM ROOF DECKING. <br />2.0 CONDENSATE PIPING AND REFRIGERANT CHASES <br />CONDENSATE PIPES SHALL BE SCH-40 PVC WITH SOLVENT WELDS, ROUTE AS SHOWN, SUPPORT TO BUILDING, PROVIDE <br />CONDENSATE PUMPS IF REQUIRED TO MAINTAIN A PITCH OF 1/8" PER FOOT. ALL INTERIOR PIPES SHALL BE <br />INSULATED WITH 3/4" THICK ARMAFLEX INSULATION SUITABLE FOR RETURN AIR PLENUMS. ALL ROOF PIPING SHALL <br />BE SECURED TO THE DECK AND CONNECTED INTO A ROOF DRAIN OR GUTTER. PROVIDE P-TRAPS AT UNIT AS PER <br />DETAIL <br />3.0 DUCTWORK AND ACCESSORIES <br />3.1 FIBERGLASS AIR DUCTS <br />1" THICK RIGID FIBERGLASS DUCTS (OWENS CORNING ENDURAGOLD) WITH INTERIOR ACRYLIC COATING, CONFORMING <br />TO SMACNA FGSDCS GUIDELINES. BONDED WITH THERMOSETTING RESIN, FIRE-RESISTANT, REINFORCED, FOIL -SCRIM <br />KRAFT PAPER FACE, R VALUE = 4.2. UL-181, UL CLOSURE, EI LABEL ON FACE. VAPOR BARRIER WITH 0.02 PERMEANCE. <br />NOISE REDUCTION OF 0.65 MIN COEFFICIENT. 250'F RATED. CLOSURE SHALL BE WITH PRESSURE SENSITIVE TAPE, PLASTIC <br />STRAPS AND GASKETING CONFORMING TO ENERGY CODE. (OWENS CORNING ENDURACOAT OR EQUAL). DUCTWORK INSTALLED <br />ABOVE ROOF INSULATION SWUl BE 1.5' THICK WITH AN R-VALUE OF 6 (MINUIMUM). <br />PROVIDE SMOKE DETECTORS WITH SERVICE ACCESS DOORS IN ALL SUPPLY AIR DUCTS AS SHOWN. ALL SMOKE <br />DETECTORS SHALL BE BY ONE MANUFACTURER, COORDINATE VOLTAGE, ETC. WITH ELECTRICAL CONTRACTOR AND <br />FIRE ALARM SYSTEM, BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHUT DOWN ASSOCIATED AIR <br />MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT AREA. <br />RIGID ROUND DUCT <br />A. DESCRIPTION: RIGID, CYLINDRICALLY MOLDED SECTIONS OF FIBER GLASS DUCT BOARD. <br />B. THICKNESS: 1 INCH. <br />C. END TREATMENT, FACTORY -MOLDED ROUND DUCT. PREMOLDED, HIGH -DENSITY, SUP JOINT. FACING EXTENDS ON END <br />WITH EXTERNAL PORTION OF JOINT TO FORM STAPLING TAB. <br />3.2 FLEXIBLE DUCTS <br />A. GENERAL' COMPLY WITH UL 181, CLASS 1. <br />B. FLEXIBLE DUCTS - INSULATED: FACTORY -FABRICATED, INSULATED, ROUND DUCT, WITH AN OUTER JACKET ENCLOSING <br />GLASS FIBER (1" THICK IN CONDITIONED AREAS, 1-1/2" THICK IN NON -CONDITIONED SPACES) INSULATION AROUND A <br />CONTINUOUS INNER LINER. <br />1. REINFORCEMENT: STEEL -WIRE HELIX ENCAPSULATED IN THE INNER LINER. <br />2. OUTER JACKET. GLASS -REINFORCED, SILVER MYLAR WITH A CONTINUOUS HANGING TAB, INTEGRAL FIBER GLASS <br />TAPE, AND NYLON WAGING CORD. <br />3. INNER LINER: POLYETHYLENE FILM. <br />3.3 SHEET METAL MAI ERUV S <br />A. SHEET METAL, GENERAL: PROVIDE SHEET METAL IN THICKNESSES INDICATED, PACKAGED AND MARKED AS SPECIFIED IN <br />ASTM A 700. <br />B. GALVANIZED SHEET STEEL: LOCK -FORMING QUALITY, ASTM A 527, COATING DESIGNATION G 90. PROVIDE MILL <br />PHOSPHATIZED FINISH FOR EXPOSED SURFACES OF DUCTS EXPOSED TO VIEW. <br />C. REINFORCEMENT SHAPES AND PLATES: UNLESS OTHERWISE INDICATED, PROVIDE GALVANIZED STEEL REINFORCING <br />WHERE INSTALLED ON GALVANIZED SHEET METAL DUCTS. FOR ALUMINUM AND STAINLESS STEEL DUCTS PROVIDE <br />REINFORCING OF COMPATIBLE MATERIALS. <br />D. TIE RODS: GALVANIZED STEEL, 1/4-INCH MINIMUM DIAMETER FOR 36-INCH LENGTH OR LESS; 3/8-INCH MINIMUM <br />DIAMETER FOR LENGTHS LONGER THAN 36 INCHES. <br />3.4 AIR DUCTS - EXHAUST AIR <br />SMACNA LOW PRESSURE CLASS GALVANIZED SHEET METAL DUCT SYSTEM WITH LOCK FORMING QUALITY. (SNAP - <br />LOCK IS OK) <br />3.5 SEALING MATERIALS <br />A. JOINT AND SEAM SEALANT. ONE -PART, NON -SAG, SOLVENT -RELEASE -CURING, POLYMERIZED BUTYL SEALANT COMPLYING <br />WITH FSTT-S-001657, TYPE I; FORMULATED WITH A MINIMUM OF 75% SOLIDS. <br />B. FLANGED JOINT MASTICS: ONE -PART, ACID -CURING, SILICONE ELASTOME RIC JOINT SEALANTS, COMPLYING WITH ASTM C <br />920, TYPE S, GRADE NS, CLASS 25, USE 0. <br />3.6 FIRE STOPPING <br />A. FIRE-RESISTANT SEALANT: PROVIDE ONE -PART ELASTOMERIC SEALANT FORMULATED FOR USE IN A <br />THROUGH -PENETRATION FIRE -STOP SYSTEM FOR FILLING OPENINGS AROUND DUCT PENETRATIONS THROUGH WALLS AND <br />FLOORS, HAVING FIRE -RESISTANCE RATINGS INDICATED AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES PER ASTM E <br />814 BY UNDERWRITERS LABORATORY, INC. OR OTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES <br />HAVING JURISDICTION. <br />B. PRODUCTS: (SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING:) <br />'DOW CORNING FIRE STOP SEALANT'; DOW CORNING CORP. <br />"3M FIRE BARRIER CAULK CP-25' ELECTRICAL PRODUCTS DN./3M. <br />"RTV 7403' GENERAL ELECTRIC CO. <br />"PYRE PUTTY"; STANDARD OIL ENGINEERED MATERIALS CO. <br />3.7 REINFORCEMENT <br />A. CHANNEL REINFORCEMENT. GALVANIZED -STEEL CHANNELS FABRICATED FROM ASTM A 527 AND HAVING G 60 OR G 90 <br />ZINC COATING WEIGHT. REFER TO FGDCS FOR CHANNEL SIZES AND SPACING. <br />B. TIE RODS REINFORCEMENT: 12-GAGE, GALVANIZED -STEEL WIRE, LENGTH TO SUIT TERMINATION METHOD. REFER TO FGDCS <br />FOR ROD SIZES AND SPACING. <br />C. REINFORCING ROD WASHERS: 2-1/2 INCHES SQUARE BY 0.028 INCHES THICK MINIMUM OR 0.020 INCHES THICK TO SUIT <br />TERMINATION METHOD, GALVANIZED -STEEL WASHER WITH TURNED EDGES. <br />D. INSTALL ANTI -SAG DEVICES IN DUCTS 48 INCHES WIDE AND LARGER. <br />E FOR NEGATIVE PRESSURE DUCTS, FASTEN REINFORCING CHANNELS THROUGH DUCTS TO 2-INCH, BY 6-INCH, BY 20-GAGE <br />GALVANIZED -STEEL CUPS AT TRANSVERSE AM AND 2-1/2-INCH-SQUARE GALVANIZED -STEEL WASHERS AT INTERMEDIATE <br />REINFORCEMENT. REFER TO SCHEDULES IN THE FGDCS FOR QUANTITIES. <br />3.8 CLOSURE <br />A MATERIALS: SELECT 1 OF THE FOLLOWING CLOSURE MATERIALS AS RECOMMENDED BY THE FIBROUS GLASS DUCT <br />MANUFACTURER: <br />1. PRESSURE -SENSITIVE TAPE: A MINIMUM OF 2-1/2 INCHES WIDE, FIBER GLASS -REINFORCED, ALUMINUM FOIL TAPE <br />COMPLYING WITH UL STANDARD 181A, PART P. AND IMPRINTED WITH THE REQUIRED INFORMATION. <br />2. HEAT -ACTIVATED TAPE: A MINIMUM OF 2-1/2 INCHES WIDE, FIBER GLASS -REINFORCED, FOIL/SCRIM TAPE <br />COMPLYING WITH UL STANDARD 181A, PART H, AND IMPRINTED WITH THE REQUIRED INFORMATION. <br />3. MASTIC AND GLASS FABRIC: A MINIMUM OF 3 INCHES WIDE, GLASS FABRIC AND DUCT MANUFACTURER'S <br />RECOMMENDED MASTIC THAT COMPLIES WITH UL STANDARD 181. <br />DRAWING INDEX <br />MECHANICAL <br />M-001 ABBREVIATIONS, LEGENDS AND GENERAL NOTES <br />M-100 MECHANICAL FLOOR PLAN <br />SPECIFICA11ONS -CONTINUED <br />3.9 HANGING AND SUPPORTING <br />A INSTALL UPPER ATTACHMENTS TO STRUCTURES WITH AN ALLOWABLE LOAD NOT EXCEEDING 1/4 OF THE FAILURE (PROOF <br />TEST) LOAD. <br />B. INSTALL CONCRETE INSERT BEFORE PLACING CONCRETE. <br />C. INSTALL POWDER -ACTUATED CONCRETE FASTENERS AFTER CONCRETE IS PLACED AND COMPLETELY CURED. <br />D. DUCT ATTACHMENT: SUPPORT HORIZONTAL DUCTS WITH TRAPEZE -TYPE HANGERS. <br />E. HANGER: SUSPEND DUCT ATTACHMENT FROM BUILDING ATTACHMENT WITH 1 OF THE FOLLOWING HANGER TYPES: <br />1. GALVANIZED -SHEET METAL STRIP, A MINIMUM OF 22 GAGE BY 1 INCH WIDE. <br />2. GALVANIZED -STEEL ROD, 1/4 INCH DIAMETER, THREADED ITS ENTIRE LENGTH. <br />3. GALVANIZED -STEEL WIRE, 12 GAGE MINIMUM. <br />F. ATTACH HUNGERS TO JOINT AND REINFORCEMENT CHANNELS THAT OCCUR WITHIN THE REQUIRED HANGER SPACING. ATTACH <br />HANGERS TO TRANSMIT LOAD TO THE SIDES AND BOTTOM CHANNELS AND NO MORE THAN 6 INCHES FROM SIDES OF DUCT. <br />G. SUPPORT EQUIPMENT AND METAL DUCT COMPONENTS AND ACCESSORIES INDEPENDENT FROM DUCT. <br />H. SUPPORT TERMINAL COMPONENTS SEPARATELY. <br />I. INSTALL SHEET -METAL SLEEVE TO SUPPORT DAMPERS. EXTEND SLEEVE FOR MOTORIZED DAMPERS TO SUPPORT OPERATOR. <br />4.0 AIR DEVICES <br />PROVIDE AIR DEVICES AS PER AIR DEVICE SCHEDULE. SUBSTITUTIONS MAY BE SUBMITTED FOR PRIOR APPROVAL. <br />4.1 FLEXIBLE CONNECTIONS <br />PROVIDE FLEXIBLE CONNECTIONS AT ALL EQUIPMENT CONNECTIONS. SWILL BE INSTALLED WITH A MINIMUM CLEARANCE <br />TO THE APPLIANCE AS SPECIFIED IN THE APPLIANCE'S INSTALLATION INSTRUCTIONS. <br />5.0 TESTING. ADJUSTING AND BALANCING <br />BALANCE AIR FLOWS FOR EQUIPMENT, INLETS AND OUTLETS FOR SPACE COMFORT. <br />6.0 SUBM <br />PROVIDE 6-SETS (EACH) OF MANUFACTURERS DATA, O&M MANUALS, ELECTRICAL DATA, DIMENSIONAL DATA AND <br />CLEARANCES, CONNECTION DATA, COLOR SAMPLES (IF REQUIRED) AND TEST DATA FOR THE FOLLOWING: <br />A/C EQUIPMENT, CONTROLS, EXHAUST FANS AND DIFFUSER/GRILLES. <br />SHOP DRAWINGS MUST BE SUBMITTED AND APPROVED PRIOR TO ORDERING EQUIPMENT. ENGINEER WILL REQUIRE <br />10 WORKING DAYS TO REVIEW DRAWINGS. <br />MECHANICAL GENERAL NOTES <br />1. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE AIR PASSAGE DIMENSIONS. <br />2. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 8'-0". <br />3. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS AND RECOMMENDATIONS. <br />4. CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL <br />EQUIPMENT AND MATERIALS. <br />5. MOUNT ALL SPACE THERMOSTATS AND/OR SENSORS 4 FEET ABOVE THE FLOOR, UNLESS OTHERWISE NOTED. <br />6. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT. <br />7. UNLESS OTHERWISE NOTED, INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO THE BOTTOM OF THE STRUCTURE. <br />COORDINATE ELEVATION AND LOCATION WITH RAIN LEADERS, WATER PIPING, PLUMBING VENTS, AND MAJOR ELECTRICAL <br />CONDUITS OR CABLE TRAY. <br />8. ALL WORK IS TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM <br />DATE OF FINAL ACCEPTANCE. ALL DEFECTS WHICH DEVELOP OR ARE DISCOVERED WITHIN THIS PERIOD SHALL BE <br />REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER. <br />9. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID CONFLICTS. <br />10. SUPPORT DUCTS PER SMACNA. <br />11. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (2004 WITH 2O05 REVISIONS), SMACNA <br />FGDCS & DCS, AND NFPA 90A. <br />12. ROUTE ALL DUCTWORK, PIPING, ACCESSORIES AS NECESSARY TO AVOID BUILDING STRUCTURE, COMPONENTS AND <br />LIGHTING. COORDINATE ANY TRANSITIONS MADE TO DUCTWORK WITH MAXIMUM FAN PRESSURE DROP REQUIREMENTS <br />FROM MANUFACTURER. ROUTE/SIZE ALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. <br />13. ALL DIMENSIONS ARE APPROXIMATE DO NOT SCALE DRAWINGS FOR CONSTRUCTION. <br />14. ALL FINISHED WORK SHALL BE FREE OF DEFECTS WITH EXISTING SURFACES MAINTAINED IN THE SAME <br />CONDITION AS ORIGINAL <br />15. ALL DEBRIS SHALL BE PROPERLY DISPOSED OF OFF SITE <br />16. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING <br />AND DUCT PENETRATIONS. <br />17. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL ACCESSORIES <br />INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE <br />18. THE WORK INDICATED ON THESE DRAWINGS IS GENERALLY DIAGRAMMATIC AND IS INTENDED TO CONVEY THE SCOPE OF <br />WORK AND INDICATE THE GENERAL ARRANGEMENT OF DUCTWORK AND EQUIPMENT, ETC. <br />19. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO IDENTIFY ABOVE CEILING CONFLICTS. THE CONTRACTOR IS <br />RESPONSIBLE TO CHECK FIELD CONDITIONS PRIOR TO BIDDING AND REPORT ANY PROBLEMS/CONFLICTS TO THE <br />ENGINEER WITHIN 2 DAYS OF DISCOVERY. ANY CHANGES RESULTING FROM CONDITIONS ARISING IN THE FIELD WHICH <br />WERE NOT BROUGHT TO THE ENGINEER'S ATTENTION ARE TO BE MADE BY THIS CONTRACTOR WITH NO ADDITIONAL <br />COST TO THE OWNER. <br />20. ALL ROOF ATTACHED EQUIPMENT AND APPURTENANCES INCLUDED IN THE SCOPE OF THIS PROJECT ARE REQUIRED TO <br />BE SECURED TO THE UNDERLYING BUILDING STRUCTURE THE FASTENING SYSTEMS SHALL BE INSTALLED TO RESIST THE <br />WIND PRESSURES ON THE EQUIPMENT AS DETERMINED IN ACCORDANCE WITH THE CURRENT BUILDING CODE. <br />21. HVAC WORK CONSISTS OF PROVIDING AIR CONDITIONING SYSTEMS FOR A COMPLETE OPERATING SYSTEM AS INDICATED ON <br />THE DRAWINGS. ALL WORK SHALL COMPLY WITH APPLICABLE CODES IN SPECIFICATIONS. IT IS THE INTENTION OF THE <br />CONTRACT DRAWINGS AND SPECIFICATION TO CALL FOR COMPLETE, FINISHED WORK, TESTED, AND READY FOR OPERATION. <br />NOTE: <br />THESE ARE STANDARD SYMBOW AND GENERAL NOTES AND MAY NOT <br />ALL APPEAR ON THE PROJECT DRAWNQM HOWEVER WHEREEi THE <br />SYMML APPEARS ON THE PROJECT DRAWNGS, THE R'EM SHALL BE <br />PRONDED AND WTALLED. <br />1 1 2 1 3 1 4 1 5 1 6 1 7 8 9 10 1 11 12 13 <br />Z:\rbk\EAST PASCO MEDICAL CENTER\081040 - Hyperbaric Treatment\Design\O8104O_M-1.dwg Feb 14, 2008 - 1:52pm alejandro.velez <br />14 <br />REVISION NO.: I DESCRIPTION: <br />CONSULTANT <br />79 G G ( <br />rA FESMO k darime <br />DATE <br />PROJECT NAME <br />FLORIDA Building"M" <br />HOSPITAL <br />Zephyrhillr Wound Care Renovations <br />SHEET CONTENTS <br />)� [SEAL <br />LEGEND, ABBREVIATIONS <br />AND GENERAL NOTES <br />-1 COMMISSION NUMBER <br />DEAN S. KENYON, P.E. DATE: <br />FL UC. No. 44012 <br />r <br />2-15-08 <br />DRAWING NUMBER <br />SHEET <br />m=001 <br />OF <br />