Laserfiche WebLink
I 1 I 2 1� <br />3 4 1 5 I 6 I 7 I 8 I 9 I 10 I 11 I 12 I 13 I 14 I <br />—X}wwwwwwwwwww�--wwww—wwwwww—wwwwwwwwwEwwwwwwwwwww w■-wwww'wwwww �� ��wwwwwwwwwww.o-wwwwwwwwwww��wwwwwwwwwww.��wwwwwwwwwwwul0.wwwwwwwwwww��wwwwwwwwwww.l��wwwwwwwwwww.��wwwwwwwwwww�.wwwwwwwwwww.� <br />L <br />H <br />G <br />F � <br />1 <br />1 <br />1 <br />Y <br />1 <br />1 <br />1 <br />1 <br />E � <br />1 <br />4 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />D � <br />1 <br />1 <br />1 <br />i <br />1 <br />-<i <br />Ij <br />ABBREVIATIONS <br />A <br />AMPERE <br />AF <br />AMPERE FRAME <br />AFF <br />ABOVE FIND FLOOR <br />AFG <br />ABOVE F110 GRADE <br />AHU <br />AIR HANDILNG UNIT <br />AL <br />ALUMINIUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AWG <br />AMERICAN WIRE GAUGE <br />C <br />CONDUIT <br />CAT <br />CATEGORY <br />CB <br />CIRCUIT BREAKER <br />CH <br />CHILLER <br />CKT <br />CIRCUIT <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />CU <br />COPPER <br />DWG <br />DRAWING <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />EM <br />EMERGENCY <br />EMT <br />ELECTRICAL METALLIC TUBING <br />ENCL <br />ENCLOSURE <br />EWH <br />ELECTRIC WATER HEATER <br />EXIST, EX <br />EXISTING <br />FA <br />FIRE ALARM <br />FCP <br />FIRE ALARM CONTROL PANEL <br />FACC <br />FIRE ALARM COMMAND CENTER <br />FATC <br />FIRE ALARM TbIMI NAL CABINET <br />FO <br />FIBER OPTIC <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GND,G <br />GROUND <br />HOA <br />HAND -OFF -AUTO <br />HACR <br />HEATING/AIR CONDITIONING -RATED <br />HID <br />HIGH INTENSITY DISCHARGE <br />HPF <br />HIGH POWER FACTOR <br />HPS <br />HIGH PRESSURE SODIUM <br />HP <br />HORSEPOWER <br />IG <br />ISOLATED GROUND <br />JB <br />JUNCTION BOX <br />KCMIL <br />THOUSAND CIRCULAR MILS <br />KVA <br />KILOVOLT AMPERE <br />KW <br />KILOWATT <br />MCB <br />MAIN CIRCUIT BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MH <br />METAL HALIDE <br />MLO <br />MAIN LUGS ONLY <br />MTD <br />MOUNTED <br />NC <br />NORMALLY CLOSED <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NEMA <br />NATIONAL ELECTRICAL MANUFACTURERS ASSOC. <br />NF <br />NON -FUSED <br />NFPA <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NIC <br />NOT IN CONTRACT <br />NIL <br />NIGHT LIGHT <br />NO <br />NORMALLY OPEN <br />PNL <br />PANEL <br />0 <br />PHASE <br />PB <br />PUSHBUTTON <br />PVC <br />POLYVINYL CHLORIDE CONDUIT <br />RGC <br />RIGID GALVANIZED STEEL CONDUIT <br />SW <br />SWITCH <br />SWBD <br />SWITCHBOARD <br />TVSS <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />TS <br />TIME SWITCH <br />XFMR <br />TRANSFORMER <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UH <br />UNIT HEATER <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />UON <br />UNLESS OTHERWISE NOTED <br />VAV <br />VARIABLE AIR VOLUME <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />V <br />VOLT <br />WP <br />WEATHER PROOF <br />ISM A 1■/1A In C%V\ Ar%^1 Nn <br />LIGHTING LEGEND <br />A <br />a <br />CEILING MTD. 2'x4' LIGHT FIXTURE (SEE SCHEDULE) <br />1 �a <br />A <br />CEI.NG MOUNTED 2'x2' LIGHT FIXTURE (SEE SCHEDULE) <br />0 a <br />CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 a <br />A <br />WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />AO a <br />CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 <br />A Q a <br />WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A ❑ 0 <br />CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A 4 a <br />WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />F--C a <br />FLUORESCENT STRIP (SEE SCHEDULE) <br />A 0-0 <br />POLE MOUNTED LUIM AIRE (SEE SCHEDULE) <br />At <br />OQ <br />2 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 i _ <br />A _ <br />3 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />11 <br />A+ <br />4 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />11 1 <br />EXIT SIGN. SINGLE OR DOUBLE FACE (SEE SCHEDULE) <br />A <br />EMERGENCY LV4T11NG FDRURE WITH BATTERY BACK-UP (SEE SCHEDULE) <br />A v v v a <br />TRACK UGiiT. MIMIBER OF HEiDS AS SHOWN (SEE SCHEDULE). <br />LIGHTING CONTROLS <br />o SINGLE POLE SWITCH 20A 120/277V LION CENTERLINE MOUNTED 48" AFF <br />M S K K: KEY TYPE M: MOTOR RATED <br />S2 DOUBLE POLE 20A 240V SWITCH - UON CENTERLINE MOUNTED 48" AFF <br />S 3 THREE WAY 20A 120/277V SNITCH - UON CENTERLINE MOUNTED 48" AFF <br />SO4 FOUR WAY WALL MOUNTED SWITCH - UON CENTERLINE MOUNTED 48' AFF <br />SD DIMMER SWITCH - LION CENTERLINE MOUNTED 48' AFF <br />TIME SWITCH AS INDICATED. UON MOUNT TOP OF ENCLOSURE 66" AFF <br />OS CEILING MOUNTED OCCUPANCY SENSOR. SEE SPECIFICATIONS <br />WALL MOUNTED OCCUPANCY SENSOR. LION CENTERLINE MOUNTED 6" <br />BELOW CEILING. SEE SPECIFICATIONS. <br />COMMUNICATIONS LEGEND <br />0 WALL MOUNTED TELEPHONE OUTLET. <br />LION CENTERLINE MOUNTED 18" AFF <br />V WALL MOUNTED DATA COMMUNICATION OUTLET, <br />UON CENTERLINE MOUNTED 18" AFF <br />0❑ FLOOR MOUNTED COMMUNICATION OUTLET <br />® POWER/DATA COMMUNICATION POLE AS INDICATED. WITH <br />(2) 20A 120V DUPLEX RECEPTACLES. <br />® COMMUNICATION EQUIPMENT RACK, SEE SPECIFICATIONS. <br />POWER LEGEND <br />HOMERUN TO PANEL INDICATED (CONCEALED). MINIMUM 3/4"C. UNLESS <br />OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY <br />NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL <br />LPLP�� CONDUCTORS. FOR HOMERUNS EXCEEDING 100' IN LENGTH PROVIDE #10 <br />CONDUCTORS IN LIEU OF 112 AS INDICATED ABOVE. THERE SHALL BE A <br />MAXIMUM OF 3 BRANCH CIRCUITS PER HOMERUN (AS INDICATED ON <br />PLANS). TEXT SHOWN BY HOMERUN INDICATES PANELBOARD DESIGNATION <br />AND CIRCUIT NUMBER(S). <br />CONDUIT CONCEALED IN WALL OR ABOVE CEILING SPACE. UNLESS OTHERWISE <br />NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 1/2"C. <br />UNDERGROUND CONDUIT OR BELOW SLAB. UNLESS OTHERWISE NOTED <br />PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4"C. <br />- - - - - EXISTING CONDUIT. AS INDICATED. <br />CEILING OR WALL MOUNTED JUNCTION BOX. LION SIZE AS REQUIRED <br />BY NEC. <br />r�. MOTOR. AS INDICATED. <br />6 120/240V 10 3W PANELBOARD. AS INDICATED. <br />HEAVY DUTY DISCONNECT SWITCH, NON FUSIBLE. SEE SPECIFICATIONS. <br />UON MOUNT TOP OF ENCLOSURE 66" AFF <br />HEAVY DUTY FUSIBLE DISCONNECT SWITCH. FUSED AS INDICATED ON <br />PLANS. SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 65" Arr F. <br />DUPLEX RECEPTACLE. 20A 12C`V UON CENTERLINE MOUNTED 18" AFF <br />DUPLEX RECEPTACLE. 20A 120V UON CENTERLINE MOUNTED 42" AFF <br />DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V LION CENTERLINE" <br />MOUNTED 18" AFF. <br />3* DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V LION CENTERLINE <br />MOUNTED 42" AFF. <br />FIRE ALARM LEGEND <br />© <br />PULL STATION. LION CENTERLINE MOUNTED 48" AFF. <br />oi <br />HORN CENTERLINE MOUNTED 80" AFF OR <br />6" BELOW CEILING, WHICHEVER IS LOWER. <br />® <br />STROBE. MOUNTED 80" AFF OR 6" BELOW CEILING <br />WHICHEVER IS LOWER <br />HORN/STROBE. MOUNTED 80" AFF OR 6" BELOW CEILING <br />WHICHEVER IS LOWER <br />CHIME/STROBE. MOUNTED 80" AFF OR 6" BELOW CEILING <br />WHICHEVER IS LOWER <br />i0 <br />HEAT DETECTOR CEILING MOUNTED <br />Q2 <br />SMOKE DETECTOR CEILING MOUNTED <br />DUCT MOUNTED SMOKE DETECTOR <br />FCP <br />FIRE ALARM CONTROL PANEL <br />UON MOUNT TOP OF ENCLOSURE 72" AFF. <br />FSA <br />FIRE ALARM SYSTEM REMOTE ANNUNCIATOR. <br />LION MOUNT TOP OF ENCLOSURE 66" AFF. <br />V <br />FLOW SWITCH <br />TAMPER SWITCH <br />0 <br />SHUT -DOWN RELAY <br />(DH <br />MAGNETIC DOOR HOLDER . <br />REMOTE ALARM INDICATOR WITH TEST SWITCH. FLUSH <br />CEILING MOUNTED. (WALL MOUNTED, CENTER LINE 48" <br />AFF IN MECHANICAL ROOMS). <br />ItcP <br />HALON CONTROL PANEL <br />LION MOUNT TOP OF ENCLOSURE 66" AFF <br />FIRE ALARM TRANSPONDER <br />UON MOUNT TOP OF ENCLOSURE 66" AFF <br />p <br />FIRE SERVICE JACK <br />lid <br />LION CENTERLINE MOUNTED 48" AFF <br />(� <br />FIRE SERVICE HANDSET <br />l� <br />H <br />UON CENTERLINE MOUNTED 48' AFF <br />tFIRE <br />DAMPER (FURNISHED UNDER DIV. 15.) <br />I <br />SMOKE DAMPER (FURNISHED UNDER DIV. 15) <br />ELECTRICAL SPECIFICATIONS <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH: <br />NFPA 70, 2005 EDITION <br />NFPA 72, 2002 EDITION. <br />NFPA 101, LIFE SAFETY CODE 2003 EDITION. <br />FLORIDA BUILDING CODE 2004 EDITION. INCLUDING THE 2005 AND 2006 <br />AMENDMENTS. <br />FLORIDA FIRE PREVENTION CODE 2004. <br />ALL APPLICABLE RULES AND REGULATIONS OF LOCAL CODES. <br />2. ALL WIRING SHALL BE COPPER TYPE THHN/THWN. SOLID FOR #10 AND <br />SMALLER, STRANDED FOR ALL CONDUCTORS 18 AND LARGER. <br />3. UNLESS OTHERWISE NOTED ALL CABLES AND CONDUCTORS SHALL BE INSTALLED <br />(CONCEALED WHERE POSSIBLE) IN AN APPROVED RACEWAY, AS FOLLOWS: <br />INTERIOR (CONCEALED OR EXPOSED): <br />a) EMT, SET SCREW TYPE FITTINGS OR COMPRESSION TYPE FITTINGS IN DAMP <br />LOCATIONS. <br />b) FLEXIBLE CONNECTION WHIPS (MAXIMUM 6'-0" LENGTH). <br />FLEXIBLE METAL CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO <br />MOTORS, LIGHTING FIXTURES AND OTHER VIBRATING EQUIPMENT. <br />ALL INTERIOR CONDUITS SHALL BE CONCEALED EXCEPT IN ELECTRICAL AND <br />MECHANICAL ROOMS. <br />EXTERIOR (CONCEALED OR EXPOSED): <br />o) RIGID GALVANIZED CONDUIT OR INTERMEDIATE METAL CONDUIT, (THREADED <br />FITTINGS AS MANUFACTURED BY CONDUIT MANUFACTURER). <br />b) FLEXIBLE LIQUIDTIGHT CONNECTION WHIPS (MAXIMUM 6'-0' LENGTH). <br />FLEXIBLE LIQUIDTIGHT CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS <br />TO MOTORS AND OTHER VIBRATING EQUIPMENT. <br />ALL RACEWAYS SHALL BE INSTALLED PERPENDICULAR AND PARALLEL <br />TO MAJOR STRUCTURAL ELEMENTS AND IN A NEAT AND WORKMAN LIKE <br />MANNER. <br />EXTERIOR (UNDERGROUND): <br />a) SCHEDULE 40 PVC. <br />4. DISCONNECTING MEANS SHALL BE OF THE HEAVY—DUTY TYPE. UNLESS <br />OTHERWISE INDICATED PROVIDE NEMA 1 ENCLOSURE. <br />5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIALS INDICATED <br />TO BE REMOVED AS PART OF DEMOLITION WORK OF THIS PROJECT. <br />CONTRACTOR SHALL CLEAN EACH AREA WHERE WORK IS PERFORMED ON A <br />DAILY BASIS. <br />5. ALL CUTTINC AND PATCHING SHALL BE RESTORED TO MATCH EXISTING <br />SURFACE AND FINISH. WHERE NECESSARY TO DRILL THROUGH EXISTING FIRE <br />RATED PARTITIONS OR FLOORS CONTRACTOR SHALL PATCH USING MATERIALS <br />OF AN EQUIVALENT FIRE RATING. <br />7. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO <br />NEW OR EXISTING WALLS, FLOOR, FURNITURE ETC. AND SHALL REPLACE ANY <br />DAMAGED ITEMS WITHOUT ADDITIONAL COST TO OWNER. USE TEMPORARY <br />COVERS TO AVOID SPREAD OF DUST AND CONSTRUCTION DEBRIS. <br />8. UPON COMPLETION OF THE WORK THE ELECTRICAL CONTRACTOR SHALL <br />TEST ALL NEW EQUIPMENT, DEVICES, ETC. FOR PROPER OPERATION. <br />REPLACE MALFUNCTIONING UNITS AND RE —TEST TO FULFILL REQUIREMENTS. <br />9. PANELBOARDS SHALL BE ACCURATELY LABELED TO IDENTIFY FINAL CIRCUIT <br />NUMBERS UTILIZED, THEIR LOAD AND LOCATION. <br />10. ELECTRICAL INSTALLATION SHALL BE CLOSELY COORDINATED WITH ALL OTHER <br />WORK. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WRIT <br />ILL—TIMED INSTALLATION INCLUDING ANY ASSOCIATED REPAIRS OR <br />REPLACEMENTS. <br />11. "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". <br />12. LIGHTING TOGGLE SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE <br />TOGGLE TYPE SWITCHES. ALL SWITCHES AND COVERPLATES SHALL BE IVORY. <br />ALL ADJACENT SWITCHES SHALL BE GANGED IN ONE COMMON COVERPLATE/BOX. <br />LOCATIONS AND HEIGHTS SHALL BE COORDINATED WITH DOOR SWINGS AND <br />COUNTER HEIGHTS. <br />13. DUPLEX AND DOUBLE DUPLEX RECEPTACLES SHALL BE 20 AMP, 125 VOLT <br />RATED, SPECIFICATION GRADE. RECEPTACLES SHALL HAVE A GREEN <br />GROUNDING SCREW TERMINAL AND A SELF GROUNDING CLIP. ALL <br />RECEPTACLES SHALL BE YVORY. <br />EXACT LOCATIONS AND MOUNTING HEIGHTS SHALL BE COORDINATED <br />WITH THE COUNTER HEIGHTS AND ALL LOCATIONS SHALL BE VERIFIED WITH <br />THE OWNER PRIOR TO ROUGH —IN. <br />GFCI TYPE RECEPTACLES SHALL BE 20 AMP 125V, NON FEED—THRU TYPE. <br />14. PANELBOARDS SHALL BE EQUIPPED W.1H COPPER BUS, 98% CONDUCTIVITY. <br />CIRCUIT BREAKERS SHALL BE OF THE BOLT —ON TYPE, SERIES CONNECTED <br />A.IC. RATINGS SHALL BE ACCEPTABLE AS PER MANUFACTURER'S UL SERIES <br />CONNECTED RATINGS DATA. AVAILABLE MANUFACTURERS SHALL BE: <br />SQUARE D, CUTLER HAMMER AND GE. <br />15. SUPPORTING DEVICES <br />DAMP LOCATIONS AND OUTDOORS: HOT DIP GALVANIZED MATERIALS, U CHANNEL <br />SYSTEM. COMPONENTS. <br />DRY LOCATION: STEEL MATERIALS. <br />STRENGTH OF SUPPORTS: ADEQUATE TO CARRY THE LOAD TIMES A SAFETY <br />FACTOR OF FOUR; MINIMUM 200—LB DESIGN LOAD. <br />16. ELECTRICAL IDENTIFICATION <br />ENGRAVED PLASTIC LAMINATE. INSTALL ON EACH UNIT OF EQUIPMENT. THIS <br />INCLUDES POWER, LIGHTING AND ALL SYSTEMS. <br />USE THE FOLLOWING COLORS FOR SERVICE, FEEDERS MID BRANCH CIRCUITS: <br />1. 120/208V: PHASE A. BLACK. PHASE B: RED. PHASE C: BLUE. <br />2. 277/48OV: PHASE A. YELLOW. PHASE B: BROWN. PHASE C: ORANGE. <br />DRAWING INDEX <br />ELECTRICAL <br />E-001 LEGEND, ABBREVIATIONS AND GENERAL NOTES <br />E-100 ELECTRICAL FLOOR PLAN AND POWER RISER DIAGRAM <br />RISER SYMBOLS LEGEND <br />GROUND FAULT SENSOR <br />bl <br />ql CIRCUIT BREAKER. AS INDICATED <br />I <br />�l <br />DRAWOUT CIRCUIT BREAKER. AS INDICATED <br />1 STARTER / CONTACTOR <br />T <br />OGENERATOR <br />b <br />/ SWITCH <br />TPFRMAL OVERLOAD ELEMENT <br />TRANSFORMER <br />FUSE <br />1 GROUND <br />— RELAY COIL, NOTED WITH TEXT <br />b <br />FUSED SWITCH <br />p <br />AUTOMATIC TRANSFER SWITCH <br />L <br />® METER SOCKET <br />17. TEMPORARY ELECTRICAL SERVICE <br />COST OR USE CHARGES FOR TEMPORARY FACILITIES ARE NOT CHARGEABLE TO <br />THE OWNER, ARCHITECT OR ENGINEER. <br />PROVIDE RECEPTACLE OUTLETS ADEQUATE FOR CONNECTION OF POWER TOOLS <br />AND EQUIPMENT. ' <br />PROVIDE TEMPORARY LIGHTING WITH LOCAL SWITCHING THAT PROVIDES ADEQUATE ' <br />ILLUMINATION FOR CONSTRUCTION OPERATION AND TRAFFIC CONDITIONS. ' <br />REVISION NO.: <br />DESCRIPTION: <br />DATE <br />RBK <br />Architects <br />I nc. <br />177 1 <br />East Ninth Avenue <br />Tel, 813.247.5223 <br />• <br />: <br />AAC000500 Copyright 2006• <br />• <br />CONSULTANT <br />3203 QUEEN PALM DRIVE <br />KPI ENGINEERING, INC. <br />PHONE �(813) 12413 6488 <br />FAX (813) 241-6498 <br />Board of Professional Engineers — Lioense / 27336 <br />PROFES510M ENWNEERS <br />— —� <br />iPROJECT <br />NAME <br />■ <br />FLORIDA <br />HOSPITAL <br />' Zepy <br />h rhills <br />SHEET CONTENTS <br />Building "MB1 <br />Wound Care Renovations <br />LEGEND, ABBREVIATIONS <br />AND GENERAL NOTES <br />rSEAI COMMISSION NUMBER <br />Q 1 <br />A i RICHARD, No. .E C. <br />i <br />Amt <br />mgna;rti�, L— Dote <br />�—�Ewwwwwwwwwww.l�.wwwwwwwwwww.o-wwwwwwwwwww�IQ.wwwwwwwwwl�waE�l�.wwwwwwwwwww��nEwwwwwwrsw•woerw.�••�w�aw.wwwwwwwwa��wwwwwwwwwwwE��wwwwwwwwwww��wwwwwwwwwwwmQl.wwwwwwwwwwwE�.•wwwwwwwwwww��wwwwwwwwwww>E.�•wwwwwwwwwww.l� �� <br />1 I 2 I 3 I 4 I 5 I 6 I 7 1 8 I 9 I 10 I 11 1 12 I 13 I 14 I <br />Z:\rbk\EAST PASCO MEDICAL CENTER\081040 — Hyperbaric Treatment\Design\081040_E-1.dwq Mar 06. 2008 — 6:56om richie.ramsaUer <br />CATE: <br />2-15-08 <br />DRNNING NUMBER <br />11' <br />SHEET OF <br />i"T �___.._ <br />