My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38233 Daugherty Rd Buildings (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38233 Daugherty Rd Buildings (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 12:58:01 PM
Creation date
2/19/2025 1:57:51 PM
Metadata
Fields
Template:
Building Plans
Street #
38233
Location
Daugherty Rd Buildings
Contractor
Sealander Construction SVC Inc
Building Plans - Permit #
7612
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />1�1 <br />1 <br />1 <br />M � <br />1 <br />1 <br />1 <br />1 <br />C <br />L <br />4 <br />K <br />J � <br />1 <br />1 <br />1 <br />1 <br />1 <br />H j <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />G � <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />F � <br />1 <br />1 <br />1 <br />h1 <br />—i <br />1 <br />1 <br />1 <br />E j <br />1 <br />1 <br />4 <br />1 <br />1 <br />1 <br />1 <br />D 1 <br />1 <br />1 <br />1 <br />c; <br />1 <br />1 <br />lm <br />A <br />1 2 3 4 5 1 6 7 1 8 9 10 11 12 1 13 1 14 1 <br />ABBREVIATIONS <br />AA AREA ALARM <br />AFF ABOVE FINISHED FLOOR <br />CLG CEILING <br />EL ELEVATION <br />EXIST EXISTING <br />FL FLOOR <br />NC NORMALLY CLOSED <br />NIC NOT IN CONTRACT <br />NO NORMALLY OPENED <br />0 OXYGEN <br />TYP TYPICAL <br />UG UNDERGROUND <br />LION UNLESS OTHERWISE NOTED <br />VIF VERIFY IN FIELD <br />PIPING <br />2 0 i OXYGEN PIPING <br />2 <br />''� VALVE IN RISER <br />0. <br />DIRECTION OF FLOW <br />T <br />TOP CONNECTION, 45 OR 90 DEG. <br />x <br />BOTTOM CONNECTION, 45 OR 90 DEG. <br />T <br />SIDE CONNECTION <br />DROP IN PIPING <br />VALVE — SEE SPECIFICATIONS FOR TYPE, <br />GATE VALVE WHEN NOT SPECIFIED. <br />IYI <br />BALL VALVE <br />PRESSURE GAUGE <br />CAPPED OUTLET <br />® <br />AREA ALARM <br />® <br />NEW MEDICAL GAS ZONE VALVE BOX <br />1 <br />1 <br />m 1 <br />—l�8��8��8��81818�818��81818�81i���81818�B�Bs�8�8���B�B�B�B�B�BI•B�B�B��B�B��B�B����B�B� <br />1 2 3 4 <br />Z:\rbk\EAST PASCO MEDICAL CENTER\081040 - Hyperboric Treatment\Design\081040-MG-1.dwg Mar 05, 2008 - 228pm joy.mollison <br />MEDICAL GAS GENERAL NOTES <br />1. CONTRACTOR SHALL PROVIDE COMPLETE MEDICAL GAS SYSTEMS AS DETAILED ON THESE <br />DRAWINGS. WORK CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT, AND SERVICES <br />REQUIRED FOR COMPLETE SYSTEMS. INCLUDE ANY INCIDENTAL APPARATUS, <br />APPLIANCES, MATERIAL LABOR AND SERVICES NECESSARY TO MAKE NEW WORK <br />COMPLETE IN ALL RESPECTS AND FULLY READY FOR OPERATION. <br />2. ALL MEDICAL GAS WORK SHALL BE DESIGNED, IK_,10 <br />"50DEVEOU <br />�ES. <br />CLEANED IN ACCORDANCE WITH NFPA 99 AN NF <br />3. MAKE SUCH OFFSETS AND DEVIATIONS FROM WORK SHOWN ON THE DRAWINGS, AS MAY <br />BE NECESSARY TO FIT THE ACTUAL SPACE CONDITIONS. <br />4. WHERE VALVES OCCUR ABOVE DRYWALL OR PLASTER OR ARE CONCEALED BEHIND <br />WALLS, THIS CONTRACTOR SHALL FURNISH AND INSTALL ACCESS PANELS. PANELS <br />SHALL MATCH EXISTING. <br />5. THE PLANS AND DIAGRAMS OF MEDICAL GAS PIPING ARE SCHEMATIC ONLY AND SHOULD <br />NOT BE SCALED. INSTALLER SHALL COORDINATE AT SITE WITH ALL PLUMBING, HVAC, <br />FIRE PROTECTION, MEDICAL GASES, AND ELECTRICAL WORK SO AS NOT TO CONFLICT IN <br />LOCATION WITH OTHER WORK UNDER THIS CONTRACT OR THAT MAY BE EXISTING. <br />6. EXACT LOCATION NUMBER MEDICAL GAS SUPPLY SHALL BE DETERMINED FROM <br />ARCHITECTURAL DRAWINGS. VERIFY SUCH LOCATIONS BEFORE PROCEEDING ROUGH -IN. <br />7. INSTALLER SHALL NOT CUT ANY STRUCTURAL MEMBERS WITHOUT FIRST SECURING <br />WRITTEN APPROVAL FROM THE ARCHITECT. <br />8. PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS BETWEEN DISSIMILAR PIPING METALS. <br />9. WHEN CONFLICTS OCCUR IN SPECIFICATIONS OR IN THE DRAWINGS, OR BETWEEN EITHER, <br />THE ITEMS OF GREATER QUANTITY OR HIGHER COST SHALL BE PROVIDED. <br />10. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID <br />CONFLICTS. <br />11. ALL NEW MEDICAL GAS PIPING SHALL BE TYPE K COPPER. MINIMUM PIPE SIZE FOR <br />OXYGEN PIPING SHALL BE 1/2". ALL NEW PIPING SHALL BE PROVIDED PRECLEANED <br />IN ACCORDANCE WITH NFPA 99 REQUIREMENTS. <br />12. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. PENETRATIONS FOR PIPES, <br />CONDUITS, OR OTHER PURPOSES THROUGH ASSEMBLIES (FLOORS„ WALLS, PARTITIONS, <br />ETC.) WITH A REQUIRED FIRE STOP MATERIAL FIRE STOP MATERIAL SHALL BE U.L. <br />LISTED AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />REQUIREMENTS TO MEET OR EXCEED THE FIRE RATING OF THE PENETRATED ASSEMBLY. <br />13. THE INSTALLER SHALL VISIT THE JOB SITE AND INSPECT ALL EXISTING CONDITIONS <br />AFFECTING THE WORK. SUBMISSION OF HIS PROPOSAL SHALL BE CONSTRUED AS <br />INDICATING SUCH KNOWLEDGE. NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS <br />THAT ARISE FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. <br />14. CONTRACTOR SHALL PROVIDE ALL REQUIRED LABELING OF ALL OXYGEN PIPING <br />VALVES AS BY NFPA 99. <br />15. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO IDENTIFY ABOVE CEILING <br />CONFLICTS. THE CONTRACTOR IS RESPONSIBLE TO ALSO CHECK FIELD CONDITIONS <br />PRIOR TO BIDDING AND REPORT ANY PROBLEMS/CONFLICTS TO THE ENGINEER WITHIN 2 <br />DAYS OF DISCOVERY. ANY CHANGES RESULTING FROM CONDITIONS ARISING IN THE <br />FIELD WHICH WERE NOT BROUGHT TO THE ENGINEER'S ATTENTION ARE TO BE MADE BY <br />THIS CONTRACTOR WITH NO ADDITIONAL COST TO THE OWNER. <br />16. UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL <br />REMOVE ALL TOOLS, APPLIANCES, SURPLUS MATERIALS, AND SCRAP. ALL IDENTIFIED <br />EXISTING EQUIPMENT TO BE REMOVED SHALL BE TURNED OVER TO THE OWNER. <br />17. CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REINSTALLING ALL CEILING TILES AND GRIDS <br />AS NECESSARY TO INSTALL NEW MEDICAL GAS SYSTEM. <br />18. CONTRACTOR TO CONTINUOUSLY PURGE MEDICAL GAS PIPING WITH DRY NITROGEN WHILE BRAZING <br />ALL PIPING JOINTS. <br />19. COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF <br />MEDICAL GAS SUPPLY PIPING. <br />20. CONTRACTOR SHALL ARRANGE FOR, OBTAIN AND BEAR THE COST OF <br />SAY R IT BONDS AN['! <br />21. ALL EQUIPMENT USED IN BULK SYSTEM SHALL BE CLEANED IN ACCORDANCE TO <br />CGA G-4.1, BEFORE PLACING INTO SERVICE. DOCUMENTATION SHALL BE PROVIDED. <br />22. TANK AND BUILDING SHALL BE PLACARD NFPA 704 SYSTEM AND WITH SIGNAGE THAT <br />STATES OXGEN, NO SMOKING OR OPEN FLAME. „/ <br />NOTE: <br />THESE ARE STANDARD SYMBOLS AND GENERAL NOTES AND MAY NOT ALL APPEAR <br />ON THE PROJECT DRAWINGS; HOWEVER WHEREVER THE SYMBOL APPEARS ON THE <br />PROJECT DRAWINGS, THE REM SHALL BE PROVIDED AND INSTALLED. <br />DRAWING INDEX <br />MEDICAL GAS <br />MG-001 ABBREVIATIONS, LEGENDS AND GENERAL NOTES <br />MG-100 MEDICAL GAS FLOOR PLAN <br />INTERIOR SIDE OF <br />i WALL <br />GYPSUM WALL I <br />MIN. 5/8" THICKNESS OF FILL METAL STUDS <br />MATERIAL APPLIED WITHIN <br />ANNULUS FLUSH BOTH SURFACES <br />OF WALL <br />i <br />PIPE CENTERED <br />IN SLEEVE <br />i <br />li <br />NOTES: <br />1. UL SYSTEM U415 NONBEARING WALL RATING 2 HR <br />2 HOUR PIPE SLEEVE -WALL PENETRATION DETAIL NOT TO SCALE <br />NEW SENSOR <br />WIRING <br />PRESSURE <br />GAUGE <br />• i <br />OXYGEN <br />s <br />OXYGEN -- <br />4 <br />ZONE VALVE ENCLOSURE <br />MEDICAL GAS ZONE VALVE CABINET NOT TO SCALE <br />MAIN PIPING <br />IN. 16) <br />INSTRUCTIONS TO NOTIFY APPROPRIATE <br />MAINTENANCE PERSONNEL IMMEDIATELY <br />IN CASE OF ALARM - COORDINATE <br />WORDING WITH OWNER. <br />AREA ALARM PANEL DETAIL <br />NOT TO SCALE <br />1 <br />C <br />1 <br />1 <br />1 <br />1 <br />U I FIRE MARSHAL COMMENTS 103/07/08 I <br />REVISION NO.: I DESCRIPTION: DATE <br />CONSULTANT <br />KPI ENGINEERING. INC. <br />- _ <'- PROFESSpNAL ENOMEEIIS <br />FLORIDA <br />HOSPITAL <br />Zephyrhillr <br />rSEAL <br />3203 QUEEN PALM DRIVE <br />TAMPA, FLORIDA 33619 <br />PHONE (813) 241-6488 <br />FAX (813) 241-6498 <br />Board of Professional Engineers — Ucense / 27336 <br />Building "M" <br />Wound Care Renovations <br />LEGEND, ABBREVIATIONS <br />AND GENERAL NOTES <br />COMMISSION NUMBER DRAWING NUMBER <br />GUY VAN MEULEBROUCK, RE <br />. LIC. No. 53808 DATE: MG=001 <br />2-15-08 <br />Date <br />J SHEET OF <br />B.ti��Bti B���B���Bti 8�8�8�8��81����������81•��8����B�B��B��B���B�������B�B��B���B�����������B��B�B�����B���B��������������ti�������B�Bti�B������� <br />5 6 7 8 9 10 1 11 12 1 13 1 14 <br />I - -- -- _TT-1-T -�--I I i 11 . 111.. , uw aii i`:1--- 11 --'r r— 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.