Laserfiche WebLink
zz <br />INTERIOR ELECTRICAL OUTLET LOCATIONS Ci <br />NAILED 6" O.C. TO <br />TOP & BOTTOM <br />PLATES W/8d NAILS <br />NAILED 12" O.C. <br />W/8d NAILS <br />2X4 BLOCKING <br />ALL JOINTS <br />PLYWD. NAILED AS SHOWN, CREATES PERFORATED <br />EXTERIOR SHEAR WALL <br />$H.EAR WALL NAIL PATTERN <br />Scale: NTS <br />WIND DESIGN INFORMATION I <br />1. Wind Speeds of 110 MPH <br />2. Importance Factor = 1,0 <br />3. Exposure Catagory B <br />4. Internal Pressure Coefficient = +/- 0.18 ENC, <br />5, Component & Cladding Pressures (PSF)i <br />R = 12,5/-42.1 W = 21,8/-29.1 OH= -68.3 <br />NOTE, WIND LOAD CALCULATIONS ARE BASED ON <br />'WORST CASE' , ALL CONNECTORS WILL BE UNIFORM <br />FOR SIMILAR USES. <br />EXISTING ROOF <br />FRAMING <br />A7 <br />EXIST. OVH. <br />HVAC SYMBOL LIST <br />// <br />7a <br />EXISTING CEILING <br />FINISH TO REMAIN <br />EXISTING 2X BEAM <br />2X4 TOP PLATE <br />NAIL TOP PLATE TO BEAM W/16d <br />NAILS EVERY 2'-0" <br />'Xss <br />1/2" GYPSUM BOARD <br />T-111 EXTERIOR SIDING <br />2X4 SPF STUDS ® 16" O.C. <br />EXISTING PIPE COLUMNS TO <br />REMAIN -FRAME NEW WALL / <br />AROUND THEM i <br />R-11 BATT <br />INSULATION <br />2X4 P.T. BOTTOM PLATE ! <br />i <br />STUD WALL ANCHORED TO SLAB W/3/8"OX5" <br />BOLTS EVERY 2'-0" ` <br />MirEXISTING SLA-B <br />I <br />EXT. I N FI LL WALL SECTION <br />SCALE: 1/2 of =1 1 —0 $1 <br />SUPPLY DIFFUSER <br />RETURN DIFFUSER <br />RETURN RISER <br />SUPPLY RISER <br />THERMOSTAT <br />ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES SUCH AS THE NATIONAL <br />ELECTRICAL CODE,LOCAL ORDINANCES AND POWER COMPANY REGULATIONS. <br />SUBCONTRACTOR SHALL BE LICENSED, CARRY ALL APPLICABLE INSURANCE, AND HAVE A CURRENT <br />Le e n d <br />COUNTY OCCUPATIONAL LICENSE. <br />O <br />SUBCONTRACTORS SHALL INCLUDE ALL SPECIAL FEES AND PERMITS,. LABOR AND MATERIAL, EQUIPMENT <br />AND ELECTRICAL ENGINEERING NECESSARY TO PROVIDE AN APPROVED WORKING SYSTEM. LIGHT FIXTURES <br />EXCLUDED EXCEPT FOR FLUORESCENT FIXTURES AND RECESSED LIGHTS. <br />CONCRETE -ENCASED ELECTRODE. AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED <br />WITHIN AND NEAR THE BOTTOM OF THE CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT <br />WITH THE EARTH, CONSISTING OF AT LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED OR <br />0 <br />OTHER ELECTRICITY CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 <br />INCH DIAMETER, OR CONSISTING OF AT LEAST 20 FEET OF BARE COPPER CONDUCTOR NOT SMALLER <br />THAN 4 AWG. REINFORCING BARS SHALL BE PERMITTED TO BE BONDED TOGETHER BY THE USUAL STEEL <br />TIE WIRES OR OTHER EFFECTIVE MEANS." <br />ALL SLEEPING ROOMS <br />AFCI RECEPTACLES IN ALL SLEEPING ROOMS PER SECTION 210.12 OF THE NATIONAL ELECTRICAL CODE <br />3 <br />2002 EDITION. <br />210.12 ARC -FAULT CIRCUIT INTERRUPTER PROTECTION. <br />(A) DEFINITION. AN ARC -FAULT CIRCUIT INTERRUPTER IS A DEVICE INTENDED TO PROVIDE PROTECTION <br />FROM THE EFFECTS OF ARC FAULTS BY RECOGNIZING CHARACTERISTICS UNIQUE TO ARCING AND BY <br />FUNCTIONING TO DE -ENERGIZE THE CIRCUIT WHEN AN ARC FAULT IS DETECTED. <br />(B) DWELLING UNIT BEDROOMS. ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE-PHASE, 15- AND <br />20- AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN <br />ARC -FAULT CIRCUIT INTERRUPTER LISTED TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT. <br />440.65 LEAKAGE CURRENT DETECTION AND INTERRUPTION (LCDI) AND ARC FAULT CIRCUIT INTERRUPTER <br />(AFCI). <br />SINGLE-PHASE CORD -AND -PLUG -CONNECTED ROOM AIR CONDITIONERS SHALL BE PROVIDED WITH <br />FACTORY -INSTALLED LCDI OR AFCI PROTECTION, THE LCDi OR AFCI PROTECTION SHALL BE .AN INTEGRAL <br />PART OF THE ATTACHMENT PLUG OR BE LOCATED IN THE POWER SUPPLY CORD WITHIN 12 INCHES OF <br />THE ATTACHMENT PLUG. <br />EXISTING CLASSROOMS <br />O <br />«0 <br />x <br />cm <br />U) <br />4-, Co <br />U <br />� <br />a� <br />I <br />a� <br />6" RECESSED CAN FIXTURE <br />WALL MOUNTED INCANDESCENT FIXTURE <br />SURFACE MOUNTED INCANDESCENT FIXTURE <br />SURFACE MOUNTED FLUORESCENT FIXTURE <br />CEILING FAN/LIGHT <br />3 WAY SWITCH <br />STD. SWITCH <br />110 VOLT OUTLET <br />220 VOLT OUTLET <br />DBL. FLOOD LIGHT <br />SMOKE DETECTOR <br />EXHAUST FAN <br />I I <br />II <br />I 1 <br />1 1 <br />I I <br />I 1 I <br />• L ------ -- -� ,-------------- r-------------------------------------- ----- <br />------------------------------------r� <br />-}� j /• III A` 11 -� � � / II <br />IIW ii i ii W <br />I <br />1 <br />I <br />1 <br />I <br />I <br />I <br />i t i <br />Ep�POPSIGN <br />R' GIP SIGN <br />------------------- ---y:c <br />RGIP SIGN <br />1 <br />- - - - - -------------------- -- - - - - - - = ---------- - - `f-----� <br />ro - _ _ _ <br />r <br />ELECTRIC/HVAC PLAN <br />SCALE 1 /4"=1'-0" <br />ELECTRICAL SUB -CONTRACTOR TO <br />PROVIDE ACTUAL SYSTEMS DESIGN & <br />TIE IN TO EXISTING SERVICE <br />These plans were prepared for this building as a minimum service by the designer. The <br />Contractor and/or Owner must verify all dimensions and actual site conditions. The <br />designer does not accept any responsibility for omissions or errors contained heroin. The <br />client understands that the designer carries no liability Insurance and therefore agrees to <br />hold harmless and defend the designeir. fr m all claims. losses- and expenses. (including.. <br />reasonable attorney fees) prising out of or resulting from the project. The designer will in <br />good faith attempt to provide error free construction drawings. but in the event errors <br />occur, the designer will not be liable for cost of repairs or delay to the construction. <br />10�1 I I I Im61 <br />�ttnNN CL <br />W <br />Zama z <br />VZd <br />LLJ <br />U1 cry o <br />to <br />U <br />? on v 1-- <br />Q <br />W <br />LU <br />� <br />U W <br />00 <br />CIO <br />u) <br />I <br />N <br />V) <br />N <br />c � <br />Ia <br />ca <br />�` M 'S <br />e ca <br />CIO <br />CU-!2 ILL <br />m n a 4)o <br />�, .to e <br />0 <br />v <br />J <br />�1 <br />z <br />U) <br />Z <br />LLj <br />— <br />O <br />z <br />—' <br />LL <br />Z <br />W <br />> <br />♦ ) <br />U <br />0 <br />Q <br />J <br />Q <br />W <br />W <br />O <br />Q <br />�U <br />z <br />= <br />� <br />c� <br />LU <br />W <br />Q <br />c <br />N <br />J <br />0 <br />pp <br />I— <br />M <br />J <br />REVISIONS: <br />Issue Date: <br />07/16/08 <br />Drawn By: <br />WWM <br />0407-04 <br />ELECTRICIHVAC PLAN <br />B3 <br />y�}� <br />YT... - .. ,..�:V .. .. :. ... .. �.1, t'..�:. �, �'r�F.l• a... .. ... - _,Ti•_".u�iT.'. i <. I•..... Y. _, . .. -.. .- ..-1 a ._�.i l"'.F 5- i'. :.I�' r - .- ..1 . :if^t � �V h _ V[.. i...-�1•.0 _. _ Y. .Y._ •`1 i L• '-�:_ • . i n. .. ..sr.... ...�_,`. e.. .-� ..... ........ _. _ .. <br />