My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38444 5th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38444 5th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:52:12 PM
Creation date
2/19/2025 1:58:38 PM
Metadata
Fields
Template:
Building Plans
Street #
38444
Location
5th Ave
Contractor
Cross Construction
Building Plans - Permit #
15890
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POWER NOTES O <br />1 I I <br />4. <br />N3 <br />1. PROVIDE TX TX 3/4" FIRE RETARDANT PAINTED PLYWOOD TELEPHONE <br />BACKBOARD WITH TOP AT T AFF. EXTEND #6 CU FROM BACKBOARD TO <br />GROUNDING ELECTRODE SYSTEM. EXTEND 1"C WITH PULLWIRE TO EXISTING <br />TEL. SVC PNL LOCATED IN RM 120. <br />2. PROVIDE WIREMOLD SERIES ALA4800 TWO CHANNEL SATIN ANODIZED AL <br />WIREWAY WITH OUTLETS 18 ON CENTER (TOP CHANNEL MOUNT). LOWER <br />CHANNEL FOR DATA CABLES. <br />3. ENTIRE CIRCUIT TO BE ON GFCI BREAKER. <br />4. PROVIDE JUNCTION BOX WITH 120V CIRCUIT AS INDICATED ABOVE DOOR. <br />GENERAL NOTES <br />1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS <br />OF THE 2008 NATIONAL ELECTRICAL CODE. <br />2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER <br />NEC 250.52. <br />3. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO <br />#10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. INCREASE <br />CONDUIT SIZE FOR 40% FILL. <br />4. REFER TO HVAC WIRING SCHEDULE FOR CIRCUITING REQUIREMENTS OF <br />SAME. <br />5. WORKING CLEARANCE SHALL BE AFFORDED TO ALL ELECTRICAL <br />EQUIPMENT IN ACCORDANCE WITH NEC 110.26. <br />6. ALL 15 & 20A,120V RECEPTACLES WITHIN 6FT OF A SINK SHALL BE GFCI <br />PROTECTED. <br />7. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH <br />CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND <br />PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY <br />TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. <br />8. WHERE COMMUNICATIONS OUTLETS ARE SHOWN ADJACENT TO POWER <br />RECEPTACLES, BOTH SHALL BE INSTALLED AT THE SAME ELEVATION. <br />9. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION <br />CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. <br />HVAC & PLUMBING EQ. WIRING SCHEDULE <br />UNIT <br />NUMBER <br />MCA <br />MOCP <br />DISCONNECT <br />BRANCH CIRCUIT <br />SWITCH <br />FUSES <br />CONDUIT <br />WIRE <br />PANEL <br />AHU-1 <br />50 <br />50 <br />N1/60/2/240V <br />-- <br />1" <br />2 #6 & 1 #10 EG <br />L-61,63 <br />AHU-2 <br />45 <br />45 <br />N1/60/2/240V <br />-- <br />V <br />2 #6 & 1410 EG <br />L-65,67 <br />AHU-3 <br />45 <br />45 <br />N1/60/2/240V <br />-- <br />1" <br />2 #6 & 1 #10 EG <br />L-69,71 <br />AHU-4 <br />48 <br />50 <br />N1/60/2/240V <br />-- <br />1" <br />2 #6 & 1 #10 EG <br />L-73,75 <br />CU-1 <br />35 <br />60 <br />N3R/60/2/240V <br />-- <br />3/4" <br />2 #8 & 1 #10 EG <br />L-64,66 <br />CU-2 <br />20 <br />35 <br />N3R/60/2/240V <br />-- <br />1/2" <br />2 #12 & 1 #10 EG <br />L-68,70 <br />CU-3 <br />20 <br />35 <br />N3R/60/2/240V <br />— <br />1/2" <br />2 #12 & 1 #10 EG <br />L-72,74 <br />CU-4 <br />28 <br />50 <br />N3R/60/2/240V <br />-- <br />3/4" <br />2 #10 & 1 #10 EG <br />L-76,78 <br />EWH <br />12.5 <br />20 <br />NI/30/2/240 <br />-- <br />3/4" <br />2 #10 & 1 #10 EG <br />L-77,79 <br />TEF-1 <br />WTFH FAN <br />-- <br />1/2" <br />2 #12 & 1 #12 EG <br />WITH LIGHTS <br />TEF-2 <br />WITH FAN <br />-- <br />1/2" <br />2 #12 & 1 #12 EG <br />WITH LIGHTS <br />System No. W-L-1049 <br />F Ratings -1 and 2 Hr (See Item 1) <br />T Rating -0 Hr <br />L Rating At Ambient -Less Than 1 CFM/sq ft <br />L Rating At 400 F -Less Than 1 CFM/sq ft <br />Section A -A <br />Wall Assembly -The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in <br />the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and <br />shall include the following construction features: <br />A. Studs -Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 <br />by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-5/8 3-1/2 in. (89 mm) wide and spaced max 24 in. <br />(610 mm) OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be <br />framed on all sides using lengths of steel stud installed between the vertical studs and screw -attached to the steel studs at <br />each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 mm) wider and 4 to 6 in. (102 to 152 mm) higher <br />than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. (51 to 76 <br />mm) clearance is present between the penetrating item and the framing on all four sides. <br />B. Gypsum Board* -5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, <br />thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 <br />Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm) for steel stud walls. Max diam <br />of opening is 14-1/2 in. (368 mm) for wood stud walls. <br />The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is <br />installed. <br />1A. Metallic Sleeve -(Optional, Not Shown) - Cylindrical sleeve fabricated from min 0.016 in. (0.41 mm) to max 0.105 in. (2.7 <br />mm) thick sheet steel. Length of steel sleeve to be equal to the thickness of wall. Longitudinal seam of sleeve welded or <br />overlapped min 1 in. (25 mm). The ends of the steel sleeve shall be flush or recessed max 1/4 in. (6 mm) from wall surfaces. <br />2. Through Penetrant -One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the <br />firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. The <br />annular space between pipe, conduit or tubing and periphery of opening shall be min 0 in. (0 mm, point contact) to max 2 in. <br />(51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of <br />metallic pipes, conduits or tubing may be used: <br />A. Steel Pipe -Nora 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe -Nora 24 in. (610 mm) diam (or smaller) cast or ductile iron pipe. <br />C. Conduit -Nora 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing, nom 6 in. (152 mm) diam (or smaller) steel <br />conduit or nom 1 in. (25 mm) diam (or smaller) flexible steel conduit. <br />D. Copper Tubing -Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Copper Pipe -Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. <br />3. Fill, Void or Cavity Material* -Sealant -Min 518 in. (16 mm) thickness of fill material applied within annulus, flush with both <br />surfaces of wall. At the point contact location between through penetrant and gypsum board, a min 3/8 in. (10 mm) diam bead <br />of fill material shall be applied at the gypsum board/through penetrant interface on both surfaces of wall. <br />SPECIFIED TECHNOLOGIES INC -SpecSeal Series SSS Sealant or SpecSeal LCI Sealant <br />*Bearing the UL Classification Mark <br />led 1Ck <br />Architecture, Inc. <br />WIEDRICK ARCHITECTURE INC. <br />AA26001799 <br />2020 HEIDELBERG AVE. <br />DUNEDIN, FLORIDA, 34698 <br />STATE OF FLORIDA <br />PROFESSIONAL ENGINEER: <br />MATTHEW OTTO <br />PE 58722 <br />L\ <br />c-i <br />cm <br />r r� <br />V <br />m <br />w <br />w <br />H <br />� � <br />v <br />w <br />� � o0 <br />�J <br />F" "' Ln <br />o <br />N � <br />w M <br />o w <br />Ln <br />0 <br />z <br />00 <br />M <br />a, <br />N <br />N <br />VV <br />`eq�``�y,�p� ,,...•v.V, U� jttp'����s� <br />e <br />No.58722 <br />STATE OF '•�� <br />.,S N Z `e <br />a.i <br />Q <br />LO <br />00 <br />M <br />N <br />Ln <br />co <br />C`7 <br />J <br />LL <br />U) <br />---! <br />J_ <br />LLI <br />N <br />PROJECT ADDRESS: <br />38444 5TH AVE. <br />ZEPHYRHILLS, FL 33542 <br />CLIENT: <br />FLORIDA PHARMACY <br />SOLUTIONS, INC. <br />13933 17TH ST. SUITE 300 <br />DADE CITY, FL 33525 <br />EM DATE I DESCRIPTION I <br />POWER PLAN <br />Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 <br />Reproduced courtesy of Underwriters Laboratories, Inc. &W-L-1 <br />1 1 Created or Revised: December 14,20101 1 049 <br />(800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com PAGE 1 OF 1 <br />POWER FLAN <br />3/1(0"=1'-011 <br />MDO <br />PROJECT #: 14-87 <br />E201 <br />10/15/14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.