Laserfiche WebLink
Existing <br />Landscape <br />Area <br />CONDENSER PAD <br />BY CONTRACTOR <br />Fp <br />+b <br />Elec A�� <br />Elec FE EXIT <br />IGI <br />LAB <br />120 <br />DW <br />table <br />iL711 <br />m <br />hand <br />I I mop <br />I sink <br />R <br />i sink <br />I I <br />L---- J <br />O <br />fd <br />WASH RM <br />12i <br />I I I <br />hand i eye <br />I sink I wash <br />� I I <br />I I I <br />ACCOUNTING <br />114 <br />RAMP <br />DN <br />Elec <br />F--F—T-7 <br />I I I ! <br />SHIPPING <br />122 <br />DISPENSING <br />121 <br />CASED <br />OPENING <br />r------------------�■ <br />3'-10%" 6'-0" 3'-6" 6'-OU 3'-6" 6'-0" <br />rack rack <br />rack rack <br />LIFE SAFETY LEGEND <br />• _ EXISTING AND/OR NEW RATED WALL ASSEMBLY. <br />REFERENCE DETAIL 3/AI00 FOR UL INFORMATION. <br />® EXISTING AND NEW EMERGENCY EXIT LIGHT FIXTURE WITH <br />ILLUMINATED FACE. <br />EXIT <br />111111111111 PRIMARY TENANT/BUILDING EXIT. <br />F.E. NEW WALL MOUNTED FIRE EXTINGUISHER <br />ADJACENT OCCUPIED TENANT SUITE. NO WORK IN THIS AREA. <br />r--®. <br />IT LOR7 <br />f] M <br />L_ <br />G D <br />BREAK <br />ROOM <br />124 <br />1 ��---T� MEN <br />LA5 1 I I I\ I 106 <br />�I i <br />119 1------ - <br />I <br />1 t TOILET <br />1 I VESTIBULE <br />1 101 <br />i <br />---� L L <br />105 <br />� <br />------- <br />� 1 a� <br />CONF. 1 <br />II PHARMACY <br />I�D ; ii 104 <br />1 24X-,8 , 1 <br />® II <br />1 <br />O 114X48 <br />1 � <br />EXISTING COLUMN TO 1 <br />W--MAIN - COORDINATE 1 <br />WITH OWNERS 1 24X48 <br />ADMIN e ■ CONSTRUCTION ■ <br />all REPRESENTATIVE ON <br />1®8 FINAL FINISH 1 <br />PHARMACY <br />1 1 24X48 , SALES <br />o 1 103 <br />1 1 24X48 , <br />1 F.E. 1 <br />COFFEE <br />LOUNGE <br />� 102 <br />----------- EXIT — — — — — — — — — — — - <br />F.E. display I�I <br />• <br />EXIT EXISTING ENTRY <br />IAI DOORS TO REMAIN <br />Elec <br />LIFE <br />5APET� PLAN <br />1 <br />mp <br />I- <br />- - — - <br />- <br />Poo" Np* 41# <br />t� r <br />iftubovdfmt000aOn Earls Side >n€ <br />UL 419 AND UL90(o <br />N.T.S. <br />ENLARGED 517E IMAGE. <br />LIFE 5AFET ' NOTE5 <br />1. THIS PLAN IS FOR GENERAL INFORMATION ONLY. PLEASE REFERENCE MECHANICAL <br />AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION <br />2. INTERIOR AND EXTERIOR ELEMENTS ARE EXISTING - CONTRACTOR TO ENSURE THAT <br />FINISH FLOOR SURFACE ELEVATIONS ARE LESS THAN 1/2" DIFFERENCE AT ALL <br />EXTERIOR AND INTERIOR DOOR LOCATIONS. <br />5COPE OF UJ0f--1;;N <br />THIS IS AN ALTERATION TO THE EXISTING FIRST FLOOR TENANT SUITE LOCATED AT 3844 5TH AVE. <br />ZEPHRHILLS FLORIDA 33542. THE AFFECTED AREA IS APPROXIMATELY 5950 SQUARE FEET. THE <br />EXISTING SUITE IS APPROXIMATELY 5,550 SQUARE FEET. THE PURPOSE OF THIS ALTERATION IS TO <br />BUILD -OUT THE SPACE INTO A FUNCTIONING MIXED USE (MERCANTILE AND BUSINESS) OCCUPANCY. <br />THE SCOPE INCLUDES MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. <br />THIS ALTERATION IS SUBMITTED USING THE PRESCRIPTIVE METHOD AS DEFINED IN THE FLORIDA <br />BUILDING CODE - EXISTING BUILDING. <br />THE FOLLOWING IS A BRIEF SUMMARY OF THE APPLICABLE CODE SECTIONS FROM THE 2010 <br />FLORIDA BUILDING CODE - EXISTING BUILDING AND THE FLORIDA FIRE PREVENTION CODE: <br />CHAPTER ONE - SCOPE AND ADMINISTRATION <br />SECTION 101BA COMPLIANCE METHODS: <br />REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY COMPLYING WITH <br />CHAPTER 3 OF THIS CODE IN BUILDINGS COMPLYINS WITH THE FLORIDA FIRE PREVENTION <br />CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE. <br />CHAPTER 3- PRESCRIPTIVE COMPLIANCE METHOD <br />SECTION 303 ALTERATIONS: <br />EXCEPT AS PROVIDED BY SECTION 3012 OR THIS SECTION, ALTERATIONS TO ANY BUILDING <br />OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING: CODE, <br />BUILDING FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING <br />BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THE FLORIDA <br />BUILDING CODE, BUILDING THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE <br />ALTERATION. <br />2010 FLORIDA FLORIDA FIRE PREVENTION CODE <br />CHAPTER 14 - MEAN OF EGRESS <br />SECTION 14.2 EXIT ACCESS CORRIDORS: <br />CORRIDORS USED AS EXIT ACCESS AND SERVING AN OCCUPANT LOAD EXCEEDING 30 <br />SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING BY WALLS HAVING NOT LESS <br />THAN A 1-HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 12.1 UNLESS <br />OTHERWISE PERMITTED BY THE FOLLOWING: <br />*L THIS REQUIREMENT SHALL NOT APPLY TO EXISTING: BUILDINGS PROVIDED THAT THE <br />OCCUPANCY CLASSIFICATION DOES NOT CHANGE. <br />2. THIS REQUIREMENT SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 11 <br />THROUGH 43 OF NFPA 101:1.13.1 <br />THE EXISTING SPACE 16 NOT SPRINKLED <br />ALL FIRE ALARM WORK, INCLUDING CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS, AND/OR <br />MODIFICATIONS TO THE FIRE ALARM SYSTEM MUST BE DONE PER NFPA -12 2001 EDITION BY A <br />LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS <br />PLEASE REFERENCE THE CODE SUMMARY (COVER SHEET) AND BUILDING DATA SECTIONS FOR <br />ADDITIONAL INFORMATION <br />UILIDINC; DATA <br />BASED ON THE 2010 FBC <br />AFFECTEDAREA.............................................................................. 5,950 SF <br />OCCUPANCY TYPE ...........................................BUSINESS AND MERCANTILE <br />CONSTRUCTION TYPE ..................................... EXISTING (V-B) - NO CHANGE <br />SPRINKLERED.................................................................................... I ...... NO <br />OCCUPANT LOAD - TABLE 1004.1.1 <br />MERCANTILE - GRADE FLOOR AREAS (100 5QFT/30 GROSS) ................ 24 <br />5U5INE55 - (3,335 SQFT/100 GROSS)........................................................ 34 <br />KITCHEN (FRONT OF HOUSE) - (192 5QFT/200 GROSS) .............................. 1 <br />STORAGE - (1135 5QFT/300 GROSS).......................................................... 4 <br />TOTAL OCCUPANT LOAD..................................................................... : ..... 63 <br />MEANS OF EGRESS <br />TOTAL EGRESS WIDTH REQUIRED (63 OCCUPANTS X 0.2).........................1311 <br />PROVIDED................................................................................................16011 <br />MINIMUM NUMBER OF EXITS REQUIRED (FBC 1021.1).................................... 2 <br />PROVIDED AND MARKED W/EMERGENCY LIGHT 51GNAGE ....................... 4 <br />New Exit 'A' Width 0 3211 <br />Existing Exit 'B' Width 66411 <br />Existing Exit 'C' Width 6 3211 <br />TOTAL 128" <br />MAXIMUM TRAVEL DISTANCE ALLOWED - FBC TABLE 1016.1 <br />MERCANTILE....................................................................................... 150 FT. <br />BUSINESS............................................................................................200 FT. <br />PROVIDED........................................................................................... 122 FT. <br />PLEASE REFERENCE THE SCOPE OF WORK FOR ADDITIONAL INFORMATION <br />W <br />a <br />0 <br />a <br />0 <br />0 <br />U <br />In <br />w <br />a <br />W <br />m <br />z <br />0 <br />a <br />0 <br />z <br />Z <br />X <br />w <br />00 <br />ied ick <br />Architecture, Inc. <br />WIEDRICK ARCHITECTURE INC. <br />AA26001799 <br />2020 HEIDELBERG AVE. <br />DUNEDIN, FLORIDA, 34698 <br />727.736.8627 <br />STATE OF FLORIDA <br />REGISTERED ARCHITECT: <br />MATTHEW WIEDRICK <br />AR94577 <br />of a <br />aj U') <br />Q M <br />LL <br />}' Cn <br />LO J <br />� J <br />Nl- m <br />w <br />M 2 <br />PROJECT ADDRESS: <br />38444 5TH AVE. <br />ZEPHYRHILLS, FL 33542 <br />CLIENT: <br />FLORIDA PHARMACY <br />SOLUTIONS, INC. <br />13933 17TH ST. SUITE 300 <br />DADE CITY, FL 33525 <br />DATE DESCRIPTION <br />12/11/14 REV 01 - OWNER COMMENTS <br />LIFE SAFETY PLAN <br />MJW <br />PROJECT #: 14022 <br />Al <br />00 <br />10/15/14 <br />