Laserfiche WebLink
Secondary Part Schedule <br />Mark <br />Part <br />G44 <br />40G2202417 <br />G45 <br />40G2502417 <br />G56 <br />01C1805417 <br />G58 <br />01C1911417 <br />G59 <br />01C2211417 <br />G98 <br />40GO511217 <br />G99 <br />40GO511317 <br />1 2'-4 3/4" <br />Dimension Key <br />Thick. <br />Depth <br />Lap <br />0.0590 <br />8 <br />1/2" <br />1'-0" <br />0.0590 <br />8 <br />1/2" <br />1'-0" <br />0.0590 <br />8 <br />1/2" <br />0.0590 <br />8 <br />1/2" <br />0.0590 <br />8 <br />1/2" <br />0.0590 <br />8 <br />1/2" <br />1'-0" <br />0.0590 <br />8 <br />1/2" <br />1'-0" <br />1. UNLESS NOTED, USE 1/2 X 1 1/2 A-325 SNUG TIGHTENED BOLTS FOR GIRT LAP, <br />GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT, <br />JAMB AND HEADER CONNECTIONS. <br />2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL <br />SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL <br />AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT <br />PRIOR AUTHORIZATION IS PROHIBITED. <br />18'-6'1 20'-O' -- 1, -- 23'-0" 20'-011 <br />THE VP ENGINEER'S SEAL APPLIES <br />ONLY .,0 THE WORK PRODUCT OF <br />VP AND DESIGN AND PERFORMANCE <br />REQUIREMENTS SPECIFIED BY VP. <br />THE VP ENGINEER'S SEAL DOES <br />NOT APPLY TO THE PERFORMANCE <br />OR DESIGN OF ANY OTHER PRODUCT <br />OR COMPONENT FURNISHED BY VP <br />EXCEPT TO ANY DESIGN OR PER- <br />FORMANCE REQUIREMENTS <br />SPECIFIED BY VP. <br />00'—O" <br />SECONDARY ELEVATION AT 1 <br />Shape Name = 100 X 200, Wall = 1 <br />THIS DRAWING, INCLUDING THE INFORMATION HEREON, <br />REMAINS THE PROPERTY OF VP BUILDINGS. <br />IT 13 PROVIDED SOLELY FOR ERECTING THE BUILDING <br />DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND <br />SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR <br />ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN <br />APPROVAL OF VP BUILDINGS. <br />THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY <br />RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP <br />IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS <br />DRAWING, DETAILS REFERENCED IN THIS DRAWING, <br />ALL APPLICABLE VP ERECTION GUIDES, <br />AND INDUSTRY STANDARDS PERTAINING TO PROPER <br />ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY <br />BRACING. <br />VP Buildings <br />3200 Players Club Circle Memphis TN 38125 <br />PERMIT SET- For Building Dept. Approval <br />SECONDARY ELEVATION AT 1 <br />REV DE1fiE BY DESCRIPTION BUILDER Canco General Contractors <br />CUSTOMER Mike Lynch <br />LOCATION Zephyrhills, Florida <br />PROJECT Wheelblast <br />NTS BUILDERS PO# 1162 <br />a <br />ruxt n <br />P.E. No. 57109 <br />VP BuUdings, Inc. <br />/ ii40 West Mountain West <br />KsrnersvHIO, NC 27284 <br />VP BUILDINGS <br />VARCO PRUDEN <br />A BlueScope Steel Company <br />VPC VERSION: 7.1 f <br />09-7858 <br />4/2/2009 <br />DRAWN/CHECK <br />FCJ <br />PAGE <br />15 <br />4/21/2009 9:29:20 NLVrvame: Mike Lynch eanopy3.VPC a division of BlueScope Buildings North America, Inc. <br />