Laserfiche WebLink
Covering Schedule <br />Id Qty Type Start Length <br />#6 17 PR 7'-9" <br />#1 17 PR 7'-9" <br />Oper. Code:l=SQ,SQ <br />Finish:K=KXL <br />Color:ZG=Zinc Gray <br />T <br />O <br />i <br />0) <br />N <br />H <br />Gage OP Fin. Color Incremeat <br />26 1 K ZG 3" <br />26 1 K ZG 3" <br />Direction <br />Left to Right From Peak <br />Right to Left From Peak <br />T3-50'-2 1/16" <br />Trim Schedule <br />Id Parts <br />T1 (5) BA1, (10) FDT10 <br />T2 CT20 <br />T3 (7)RCHB15,(5)RKF20,RKF10 <br />Color Details <br />Match Wall Color EN52A1,RC00AI,WC01A7,WC04A1 <br />Match Wall Color WC20A1 <br />Cool Colonial Red RC30Bl <br />F t t t t t t F C C L t t t C t t t C C t <br />O\ O M 1D D1 O M �D Qf O M I,D Ot Ol \D M O D1 �D M O <br />I I I I I I I I I I I I I 1 1 I I 1 I I I <br />a� Ln n In In ID w I` !` h I- r b ID %D <br />(17)#1 <br />1. PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS <br />MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP <br />LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS <br />2. WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, <br />REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. <br />3. PANELS SHOWN WITH A LENGTH LESS THAN 1-0, 5-0 FOR SSR, MAY HAVE <br />TO BE FIELD CUT. <br />4. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. <br />THE VP ENGINEER'S SEAL APPLIES <br />ONLY TG THE WORK PRODUCT OF <br />VP AND DESIGN AND PERFORMANCE <br />REQUIREMENTS SPECIFIED BY VP. <br />THE VP ENGINEER'S SEAL DOES <br />NOT APPLY TO THE PERFORMANCE <br />OR DESIGN OF ANY OTHER PRODUCT <br />OR COMPONENT FURNISHED BY VP <br />EXCEPT TO ANY DESIGN OR PER- <br />FORMANCE REQUIREMENTS <br />SPECIFIED BY VP. <br />00'-0" <br />COVERING ELEVATION AT 1 <br />Shape Name = 100 X 200, Wall = 1 <br />THIS DRAWING, INCLUDING THE INFORMATION HEREON, <br />REMAINS THE PROPERTY OF VP BUILDINGS. <br />IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING <br />DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND <br />SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR <br />ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN <br />APPROVAL OF VP BUILDINGS. <br />THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY <br />RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP <br />IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS <br />DRAWING, DETAILS REFERENCED IN THIS DRAWING, <br />ALL APPLICABLE VP ERECTION GUIDES, <br />AND INDUSTRY STANDARDS PERTAINING TO PROPER <br />ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY <br />BRACING. <br />(17)# <br />VP Buildings <br />3200 Play#rs Club Circle Memphis TN 38125 <br />REV <br />BY <br />NTS <br />u <br />0 <br />In <br />a <br />a <br />v� <br />v <br />M i <br />N <br />E <br />PERMIT SET- For Building Dept. Approval <br />COVERING ELEVATION AT 1 <br />DESCRIPTION BUILDER Canco General Contractors <br />CUSTOMER Mike Lynch <br />LOCATION Zephyrhills, Florida <br />PROJECT Wheelblast <br />BUILDERS PO# 1162 <br />N <br />E+ <br />W. Truxton <br />AI ��09 57109 <br />VP�M d ngs, kv- <br />K �y 1140 West MoumdWn Sh 8 <br />r Kennomwift NC 2M4 <br />JOBNO <br />09-7858 <br />DATE <br />PVP BUILDINGS 4/2/2009 <br />VARco PRUDEN DRAWN/CHECK <br />A BlueScope Steel Company FCJ <br />PAGE <br />VPC VERSION: 7.1 f 20 <br />4/21/2009 9:29:26 """"" Mike Lynch canopy3.VPC <br />a alvision or timescope rsuuaings rvortn America, inc. <br />