()Frame Member Schedule <br />Part <br />Mem <br />Width <br />Thick <br />WebThk. <br />Depthl <br />Depth2 <br />CX003 <br />1 <br />6" <br />.5000 <br />.1875 <br />1'-0" <br />3'-2" <br />RBX003 <br />2 <br />6" <br />.5000 <br />.1875 <br />3'-3" <br />1'-4" <br />3 <br />6" <br />.3125 <br />.1345 <br />1'-4" <br />1'-4" <br />4 <br />6" <br />.3125 <br />.1644 <br />1'-4" <br />2'-4" <br />RBX004 <br />5 <br />6" <br />.3125 <br />.1644 <br />2'-4" <br />1'-4" <br />6 <br />6" <br />.3125 <br />.1345 <br />1'-4" <br />1'-4" <br />7 <br />6" <br />.5000 <br />.1875 <br />1'-4" <br />3'-3" <br />CX004 <br />8 <br />6" <br />.5000 <br />.1875 <br />1'-0" <br />3'-2" <br />F <br />O Q <br />tn OD <br />O p <br />N � <br />L <br />o w <br />a N <br />h _. <br />it9X003 <br />Approx.Lgth <br />1 8 ' — 7 " <br />46'-6 5/8" <br />46'-6 11/16" <br />18' -7" <br />`.Bolt connection & Plate Schedule <br />Id <br />Qty <br />ASTM <br />Bolt <br />Bolt <br />Plate <br />Rows <br />Ruws Tension <br />Dia. <br />Length <br />Thick. <br />Out <br />In Bolt <br />A <br />16 <br />A325 <br />3/4" <br />2" <br />1/2" <br />4 <br />4 <br />B <br />10 <br />A325 <br />3/4" <br />2" <br />3/8" <br />2 <br />3 <br />C <br />12 <br />A325 <br />3/4" <br />2 1/4" <br />5/8" <br />4 <br />2 <br />G'-2 1/16" 1.000:1 <br />L- 4'-6 <br />Washer <br />0 0 <br />Ln Ln <br />0 0 <br />v m O Pq M Pq <br />Lu <br />RBX004 <br />100'-01, <br />FRAME CROSS SECTION AT FRAME LINES) 2 <br />O <br />.-1 <br />Cq <br />[u <br />1.000;12 <br />-9 @ <br />Frame Clearances <br />Horiz. Clearance between members 1(CX003) and 8(CX004): 92'-2 9/16" <br />Vert. Clearance at member 1(CX003): 15'-1 1/2" <br />Vert. Clearance at member 8(CX004): 15'-1 1/2" <br />Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) <br />w <br />W <br />O <br />C <br />N <br />.-1 <br />Cv <br />N <br />T <br /><P O <br />O LO <br />O O <br />LO <br />�+ O <br />a <br />1(2)FB4050 -j <br />I <br />I <br />I <br />I <br />� I <br />0 <br />0 <br />� 1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />a <br />9 23'-2" Ridge Ht. <br />8 3 1/2" <br />7 2 @ 3'-10 15/16" W isZ� <br />6 1 ' - 6 11 / 16" Oq yp BuNdings, Inc. <br />_ 1v %y 1114o west Mount M SO9 <br />5 3 0 1 <br />4 3 ' -11 1 / 2 " Ksmesvft, NC 2rA4 <br />3 3'-5 1/4" <br />2 4'-0" <br />1 8 1/2" PERMIT SET- For Building Dept. Approval <br />u Dimension Key Shape Name = 100 X 200 Wall 4, Frame 2 <br />THIS DRAWING, INCLUDING THE INFORMATION HEREON, <br />1. USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO THE VP ENGINEER'S SEAL APPLIES REMAINS THE PROPERTY OF VP BUILDINGS. VP Buildings <br />FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS ONLY TO THE WORK PRODUCT OF IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING FRAME CROSS SECTION AT FRAME LINE(S) 2 <br />VP AND DESIGN AND PERFORMANCE DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND 3200 Players Club Circle Memphis TN 38125 <br />UNLESS NOTED OTHERWISE. REQUIREMENTS SPECIFIED BY VP. SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR <br />THE VP ENGINEER'S SEAL DOES ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN REV DATE BY DESCRIPTION BUILDER JOBNO <br />2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME APPROVAL OF VP BUILDINGS. <br />NOT APPLY TO THE PERFORMANCE Canco General Contractors 09-7858 <br />SIDE OF THE WEB AS THE HILLSIDE WASHER. OR DESIGN OF ANY OTHER PRODUCT CUSTOMER <br />OR COMPONENT FURNISHED BY VP THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY Mike Lynch DATE <br />RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP LOCATION 4/2/2009 <br />EXCEPT TO ANY DESIGN OR PER- IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS Zephyrhills, Florida FVAR0 <br />DINGS <br />FORMANCE REQUIREMENTS DRAWING, DETAILS REFERENCED IN THIS DRAWING, EN DRAWN/CHECK <br />SPECIFIED BY VP. ALL APPLICABLE VP ERECTION GUIDES, PROJECT Wheelblast FCJ <br />AND INDUSTRY STANDARDS PERTAINING TO PROPER A BlueScope Steel Company <br />ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BUILDERS PO# PAGE <br />BRACING. NTS 1162 VPC VERSION: 7.1 f 6 <br />4/21/2009 9:29:07 FILFNAME: Mike Lynch canopy3.VPC a division of BlueScope Buildings North America, Inc. <br />