GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE <br />RESIDENTIAL AND 2009 SUPPLEMENTS <br />T.L. HANSON t ASSOCIATES A REGISTERED LICENSED, FLORIDA PROFESSIONAL <br />ENGINEERING COMPANY: HAS APPLIED " RATIONAL ANALYSIS" FOR THE STRUCTURAL <br />DESIGN OF THIS STRUCTURE <br />THE BUILDING l INCLUDING ALL COMPONENTS AND CLADDING$ SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS <br />FLOORS: <br />LIVE LOADS. - 40 P,S.F, <br />DEAD LOADS 10 P.S.F. <br />GARAGE SLAB: <br />LIVE LOADS - 50 P.S.F. <br />DEAD LOADS - 10 P.S.F. <br />ROOF: <br />LIVE LOADS (TRUSS TOP CORD) - 20 P.S.F. <br />DEAD LOADS (TRUSS TOP CORD) - 10 P.S.F, 18 P.S,F, WHEN TILE ROOF INSTALLED <br />DEAD LOAD (TRUSS BOTTOM CORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 1 P.S.F. <br />WIND DESIGN ASSUMPTIONS: <br />WIND SPEED 120 MPH <br />BUILDING EXPOSURE - B <br />BUILDING IMPORTANCE FACTOR - 1.0 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT t EXPOSURE ADJUSTMENTS COEFFICIENT - 1,0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT - + / - 0.18 <br />COMPONETS t CLADDING PSF ROOF - 14.9/-50.1 WALL - 25.9/-34.1 <br />OVER HANG - -81,2 <br />STUCCO THICKNES: <br />OVER FRAME GABLE 1/8" STUCCO OVER FELT BACKED GALV <br />LATH <br />OVER MASONARY WALL 1/2" 2 COAT STUCCO <br />GABLE ENDS WITH SIDING BACK WITH 015 FELT <br />SOIL BEARING t COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF <br />2000 P.S.F,( MINIMUM ) THE CONTRACTOR/PROPERTY OWNER IS RESPONSIBLE FOR VERIFYING <br />THAT THE SOIL ON THE SITE IS PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN <br />SUPPORT A 2000 P.S.F. FOUNDATION LOADING <br />T,L, HANSON t ASSOCIATES A REGISTERED LICENSED FLORIDA PROFESSIONAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATION$ WITHOUT VISITING THE CONSTRUCTION <br />SITE NOR PERFORMING ANY SOIL TESTING <br />T,L, HANSON t ASSOCIATES SHALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT <br />THE BUILDING LOADS <br />FOUNDATION i SLAB - ON- GRADE NOTES <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS:, <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P,S.F. FOUNDATION LOADING. SLAB <br />SHALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED <br />AND TERMITE POISONED SOIL <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 3000 P.S.F. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR <br />OS REBAR , 30" FOR 06 REBAR # 35" FOR 01 REBAR <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSE$ ( AFTER <br />FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ENGINEER WHEN MORE THAN 4 COURSE ARE REQUIRED <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A <br />STRING STRECTED FROM MARKER TO MARKER TO VERIFY REQUIRED SET BACKS <br />MASONRY WALLS: <br />CONCRETE MASONRY UNIT SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 <br />AND SHALL HAVE MINIMUM WM OF 1500 P,w. <br />MORTAR SHALL CONFORM TO ASTMC -210 AND SHALL BE EITHER TYPE M OR S <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTMA-615. LAP SPLICES WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 05 REBAR <br />30" FOR 06 REBAR AND 35" FOR 01 REBAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/8" PLACED AT 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH or- <br />2000 P.$.I, ( WHEN TESTED PER ASTM C-1O19 ) <br />PROVIDE CLEAN OUT OPENINGS ( 12 SO, IN, ) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, <br />A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL BE ISSUED, THE CERTIFICATE <br />SHALL STATE: (PER FBC R320.1) <br />THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT <br />OF AGRICULTURE AND CONSUMERS SERVICES <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION <br />SECTION R320.1 THROUGH R320.1.6 DO NOT APPLY. A SIGNED FIVER EYAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION. MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALIPRIOR TO FINAL BUILDING APPROVAL ( PER MC R320,1.1) <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION <br />BACKFIL.LING 4 COMPACTION ARE COMPLETE ( PER FBC 320.1.2.) <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE- TREATED <br />INCLUDING ANY BOX OR FORMED AREAS ( PER FBC R320,1.2) <br />BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAP$ SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT ( PER MC R320.1.3) <br />A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL <br />BE REQUIRED (PER FBC R320,1.4) <br />ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, ( PER FBC R320,1,5) <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC R320,1.6) <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED (PER FBC R320,1,6) <br />CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING <br />SIDE WALLS (PER FBC R320,1) <br />AFTER ALL WORK IS COMPLETE ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITH IN 12" OF THE BUILDING, THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS <br />PER (FBC R320,8,3,) <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" TO ALLOW FOR INSPECTION FOR FUTURE <br />TERMITE INFESTATIONS (PER FBC R104) <br />EXTERIOR WINDOWS E DOORS: <br />ALL EXTERIOR WINDOWS 4 GLASS DOORS OR ENTRANCE DOOR SHALL BE TESTED IN ACCORDANCE WITH <br />ANSI/AMMA/NWWDA 101/162 STANDARD AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURE <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TEST OR ENGINEERED TO TRANSFER <br />1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE <br />INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE MANUFACTURE ANCHORING RECOMMENDATIONS <br />TO ACHIEVE THE DESIGN PRESSURES SPECIFIED <br />ELECTRICAL, PLUMBING, 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES, THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON <br />ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />ALL ELECTRICAL OUTLETS IN BEDROOMS 4 FIXTURES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"AFI" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E.C, <br />DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR <br />CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL <br />BE CONSTRUCTED OF MINIMUM NO,26 GAUGE SHEET STEEL OR <br />OTHER APPROVED MATERIALS AND SHALL HAVE NO OPENINGS <br />INTO THE GARAGE ( FBC 2004 R309,1.1.) <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATION FOR THE PURPOSE OF <br />GLAZING <br />(1) GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF SLIDING DOORS <br />ASSEMBLIES <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60" ABOVE THE DRAIN INLET <br />(3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED <br />POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FINISH FLOOR OR <br />WALKING SURFACE <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE , THAT MEETS ALL OF THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 60, FT. <br />(B) BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY <br />OF THE PLANE OF THE GLAZING <br />REFER TO THE 2001 FLORIDA BUILDING CODE RESIDENTIAL - SECTION R308 FOR <br />ADDITIONAL AREAS THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE <br />PURPOSE OF GLAZING <br />DRAFTSTOPPING: <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPINGS SHALL BE PROVIDED ( PARALLEL TO THE MAIN <br />FRAMING MEMBERS) IN FLOOR / CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />SHALL BE CONSTRUCTED SUCH THAT THE FLOOR / CEILING ASSEMBLEY IS BROKEN UP INTO TWO OR MORE <br />APPROXIMATED AREAS WITH NO AREA GREATER THAN 1000 SQ.FT. <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ. FT, AND HAVING <br />MINIMUM 30 INCHES OF VERTICAL HEIGHT. ROUGH FRAMED OPENING NOT BE LESS THAN 22"X30" <br />INCHES, WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC IT SHALL BE INSTALLED IN <br />ACCORDANCE WITH 2O04 FLORIDA BUILDING CODE RESIDENTIAL - SECTION M1305,1.3 <br />TIMBER MATERIALS: <br />ALL TIMBERS MATERIALS SHALL BE AS FOLLOWS: <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE 02 SPRUCE ( OR BETTER) <br />ALL OTHER STUDS SHALL BE "STUD GRADE" SPRUCE SPACE 16" OC, ALL SPLICES AT <br />TOP PLATE MUST BE MINIMUM *0" AND NAILED 4" OC WITH 12D COMMON NAILS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 *2 SPRUCE OR BETTER WITH SINGLE 2 X 4 P,T, <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED PRIOR TO REQUESTING THE FRAMING INSPECTION, <br />GARAGE ADDITION ELECTRICAL PLAN 1/411 = 11 011 <br />ELECTRICAL LEGEND <br />220 V <br />G,F,1. IIO V <br />00 CHANDLER <br />J GROUND FAULT <br />(� RECEPTACLE <br />ON <br />awlrcH <br />A.F.I. 110 v <br />9 4 o VANITY LIGHT <br />d110 <br />ARC FAULT <br />V <br />RECEPTACLE <br />v v v TRACK LIGHT <br />WP <br />110 v <br />WATERPROOF <br />CEILING FAN <br />� EXTERIOR DSL FLOOD <br />OUTLET <br />11Ov LIGHT <br />CAN BE CEILING <br />FLUORESCENT <br />OR WALL (tYP) <br />CEILING <br />FIXTURE <br />FAN W/ LIGHT <br />SMOKE <br />DETECTOR <br />O CAN/ BALL FIXTURE <br />�p WALL SCONCE <br />IOV 80 CFM'S <br />®I <br />BATH FAN <br />ELECTRICAL PANEL <br />G.D.o. <br />■ <br />BATH FAN <br />TELEVISION <br />LIGHT COMBO <br />MIMI <br />MULTI MEDIA <br />® PHONE <br />CAT 6 <br />IN ACCORDANCE WITH CHAPTER 411,003 (2) (U OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON <br />ARE BASE UPON A DESIGN PROVIDED BY THE OWNER r0 ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN &' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GPI" CIRCUIT <br />ALL ELECTRICAL OUTLETS IN BEDROOMS t FIXTURES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"AFI" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C, <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED <br />DESIGNS AND FOUND IT TO @E IN COMPLIANCE WITH CHAPTER <br />Irv, SECTION 160E OF THE FLORIDA BUILDING CODE FOR 120 MPH <br />(3 SECOND GUST) WIND ZONE - 100 MP" FASTEST SPEED AND THE <br />ENTIRE 200.1 FLORIDA BUILDING CODE RESIDENTIAL AND ALL <br />200% SUPPLEMENTS <br />T.L. HANSON P.E. LICENSE NO. 38654 <br />P.O. BOX 1728, DADE CITY, FL 33526 <br />0 <br />h N <br />o Z <br />ti tits <br />Z_ V) O W <br />y Q La N 0 <br />M M <br />Q <br />W M L W <br />Z O L <br />h <br />O L' h <br />O <br />N N v <br />3 <br />F� <br />Q M <br />Z 000 <br />Z <br />4 mo M W <br />C� Lu In <br />U <br />LL W <br />LL <br />O <br />O <br />M <br />Z xm <br />m <br />V�q <br />O Z ul lu u <br />III ,� <br />z?cl) °� <br />a <br />o z <br />11 <br />z <br />z �=3 OU <br />�= d z z <br />'V <br />OW <br />n <br />u� <br />N <br />In <br />m <br />Q <br />O <br />rL <br />O <br />z <br />z <br />., <br />Q Q <br />�5 <br />O <br />wwnn _A <br />V!y <br />O <br />ED <br />� <br />� Z <br />Qa <br />O <br />Q <br />CARPORT <br />ADDITION 432 <br />LIVING <br />AREA 144 <br />TOTAL 51ro <br />P� <br />4OF4 <br />