Laserfiche WebLink
42" KNEE WALL WITH <br />CAP & CASING OR <br />- <br />36" RAILING <br />36" <br />3/4" PLYWOOD <br />DECKING <br />PRE-ENG FLOOR <br />-- - <br />TRUSS <br />10 '`;. <br />1xTREAD(TYP.) <br />3/4" PLYWOOD <br />DECKING <br />7 _. <br />1x RISERS (TYP.) <br />2x6 LANDING­--,,,�'A <br />. <br />2x4 FRAMING <br />5 <br />42" KNEE WALL WITH F <br />STRINGERS <br />4 <br />1x8 CAP & CASING OR <br />3 <br />36" RAILING <br />- <br />DECKINGOOD <br />M <br />2 <br />UST <br />2x6 LANDING - <br />1 <br />BLOCK <br />2x4 FRAMING <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />T� <br />---- <br />CONT. HANDRAIL <br />H. GRASPAABLEBLE RETURN TO <br />GRASPABLE <br />RAILING <br />WALL D E T A I L <br />SCALE: NTS <br />TYP. STAIR SECTION <br />2x4 THRUST <br />BLOCK <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />1/2 inches between the wall and the handrails. <br />Grip -size: <br />andrails with a circular cross section shall have an outside diameter of not less than 11 /4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />uards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />nches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />nches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />phere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1, <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOi <br />STRINGERS - <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />25'-0" <br />6'-7" 16'-1" 2'-4" <br />1 <br />D2 H1 D Fi1 O 2x4 #2 SPF STUDS @ 16" @ <br />TYP. @ O 6 B 6 O.C. TYP, 2nd FLOOR <br />CORNERS (2) 25-SH 1/2 33 SH e EXTERIOR WALLS <br />EGRESS D2 TEMP D2 <br />in 4-SH � CC <br />1668I I B P <br />B.F. SPECS. <br />�- 2,-4„ 5 -6" 4:-4„ <br />4 L___- I <br />3 <br />D2 246 0, BATH 1 I o TEMP. GL. <br />FLAT C iG I ENCL. ON 42" <br />SIM. w/ (1) G.T.. o R/SH HIGH KNWL. <br />MSTAM36--------' iv --=� <br />@ BASE' 48x42 ; <br />12'-10" T-2" -0" 1 T a I. 7,_ <br />\0' $HIO 3 <br />D2 <br />iv F---�� i i -- TtLETO SIM.w/(1) <br />7'A.F.F. MSTAM36 <br />36" x22" I ----�J I - @ BASE <br />OWNERS ATTIC I h <br />(; <br />ACCESS 8'-0" F T CLG la N <br />AR T _�__ " SUITE C <br />8'-0" FLAT CLG 2468 I P <br />;n CARPET <br />F- <br />N <br />4068 <br />B.F. <br />10 <br />ao CD <br />40 <br />- - - - - R/SH - - - - BEDROOM 2 <br />- - 8'-0" FLAT CLG <br />CARPET <br />7-6" A4. 4'-8" 4' 12'-2" <br />u 6 <br />ih 19 N W D2 n <br />V7 T <br />� A H1 � <br />1 g 42" H 1 /2 WALL 2668 5068 <br />15 OR RAILING PER B.F. <br />`r <br />SPECS <br />14 J <br />CO S6 <br />c=n 13 N <br />D2 N NA R/SH TYP. @ 2 <br />12 0, STORY. SEE <br />H1 O 11 TECH ao o 1 o JJ/S6 FOR <br />CENTER u STEMWALL <br />10 OPT. <br />T- <br />3'-11" 9 T-3" 5'-8- 3'-4" b'-7" 3'-3" <br />1 8 ti6�6 - -H I LE TO <br />L1 7 � -11 0" FLAT CL T A.F.F. <br />2868 TIL <br />6 <br />3 I <br />t <br />D2 ) N <br />SIM. w/ (1) 4 <br />fV <br />MSTAM36 <br />@ BASE 68 <br />N BEDROOM 3 D2 <br />o, 8'-0" FLAT CLG SIM. w/ (1) <br />- - - - - - - G.T. - I - - - - - CARPET MSTAM36 <br />@ BASE <br />11'-2" 2'-4 1 11 6- <br />-) - - - - - - <br />------- G.T. - - I-------� <br />00 <br />SIM. w/ (1) <br />MSTAM36 <br />3 BEDROOM 4 T r @ BASE <br />CARPET G ( C7 I 3 <br />D2 <br />D2 8'-0 <br />SIM. w/ (1) I r <br />MSTAM36 0 = <br />@ BASE a I m 1/2 33 SH <br />I H1 B 6 I <br />I D2 I N <br />I <br />25-SH 22 25-SH <br />GRESS D2 EGRESS e I <br />D2 � <br />H1 O D1 O(D I "' <br />I <br />----------� <br />2'-11" 13'-6• 2'-11" Z-l(r 2'-10" <br />1914" V-8" <br />2S-(r I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L--------------------------------------I <br />hEVISION NOTES 12/1712009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 71/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />i;SEE <br />SN SHEET SEE SN SHEET <br />\K <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X25 <br />S.H. <br />13 <br />20 X 38 J <br />181 X 37 i <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 2' <br />S.H. <br />16 <br />20 X 72 <br />18 2'X 71' <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 J <br />S.H. <br />1H3 <br />27 1/4 X 38 J <br />26 x 37 1 <br />S.H. <br />1 H4 <br />271 X 508 <br />26 x 50 <br />S.H. <br />1 H5 <br />2714 X 63 <br />26 X 621 /2 <br />S.H. <br />1 H6 <br />2714 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 $ <br />36 � X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 8 <br />36 1 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 2 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />3612 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 <br />S.H. <br />33 <br />54 X 38 J <br />5212 X 37 <br />S.H. <br />34 <br />54 X 501 <br />52 2 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 621 <br />S.H. <br />36 <br />54 X 72 <br />5212 X 7112 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />ueneral N01155 <br />R302.5 Dwelling/Garage Open Ino/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />11302.9.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA <br />2073 S.F. <br />GARAGE <br />396 S.F. <br />LANAI <br />104 S.F. <br />ENTRY <br />32 S.F. <br />TOTAL SQ. FT. <br />2605 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - A <br />eD <br />.--- <br />as WLU <br />� <br />O <br />O <br />C tt1 C �t <br />CO <br />Co CS i <br />N C-4 t7 <br />Q d C-4 <br />•j � L C <br />0 <br />is a <br />!2 c <br />� .� cu <br />i C tm <br />N =- <br />2E <br />a <br />0 <br />;t�y 0 w 1501 <br />FJ <br />N �t10 <br />. <br />. J `� <br />✓/,r90PESS1ONr <br />ryu0111l11110110 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />t» <br />g <br />E <br />co <br />0 <br />` N ib <br />0 <br />N <br />000 <br />0 <br />tnnQ <br />Q <br />N O'�T <br />M J LL W <br />Z <br />Ju_u o. <br />@ �rn a <br />W <br />L;a`r9 <br />� '16 04 <br />i211- n <br />Z <br />LLW <br />IL <br />U-) 0 7 <br />04 M Z d l= <br />ZN <br />< <br />O L) <br />W <br />❑❑ <br />R ; <br />Z N M <br />J - <br />13 <br />N <br />C1 <br />v <br />V <br />Cll <br />� <br />U <br />W <br />O <br />w 8 <br />�r <br />C� <br />L <br />x <br />N d7 <br />M <br />W <br />M <br />M <br />� <br />Z <br />a <br />U_za <br />f <br />o 'oLL <br />s <br />Q <br />E 0 <br />(O <br />w <br />izz <br />z0 <br />oa <br />UO <br />F <br />- <br />X U <br />D U <br />oZ <br />z <br />O <br />N <br />aZ <br />z <br />r9 <br />- <br />ZZ <br />yg <br />mo <br />W 2 <br />Z <br />a�i <br />CZ <br />J <br />7 <br />< <br />Q <br />Z <br />g° <br />d <br />�w <br />W <br />= <br />� <br />C) <br />Z <br />wa <br />F <br />'_ <br />Illlllllllll� <br />ca <br />a' <br />>M <br />O <br />rn <br />O <br />� <br />M <br />Co ,- <br />O <br />TT <br />V ! <br />ca <br />rrO <br />4-0 O <br />� <br />CV <br />C:) <br />-0 <br />O <br />Ln <br />N <br />Q <br />^ <br />r <br />E <br />a M <br />N <br />z <br />z <br />c <br />O <br />E <br />N <br />a <br />U J <br />Q 0 <br />J <br />JOB <br />NO: <br />22-08302 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />t <br />M� <br />I <br />