My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6304 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6304 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:34:23 PM
Creation date
2/19/2025 2:01:45 PM
Metadata
Fields
Template:
Building Plans
Street #
6304
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5285
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />10 #14 to lights & outlets <br />NEMA 1 <br />#12 to appliances and GFI <br />150 AMP/ <br />200 AMP <br />10 #10 to WH <br />10 #8 to Range <br />10 #6 to HVAC <br />:' <br />n <br />200 amp <br />150 amp <br />UNDERGROUND [Dis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />150=2/0 <br />200=410 in 2" Conduit <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />GENERAL ELECTRICAL NOTES. <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />Zp3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1.5" VTR _III 3" VTR <br />I� <br />��I I <br />I� I <br />I I <br />I ^ I <br />I � I <br />3" VTR <br />I I ,,, I � ►III <br />m <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />A/C PAD <br />DISC. WP <br />GFI <br />/f11 <br />WALL MOUNTED LIGHT FIXTURE --------------------------I-------- I <br />O RECESSED LIGHT FIXTURE OZ Z GARAG E E NTRY I <br />Q I I <br />- H-------- I I I <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS - / U _j —�"�� GFI DB & GFI TO I I <br />06 L_ IGARAGE------- BE ALIGNED <br />TRACK LIGHT - w _ , IGHT AS VERTICALLY J <br />u_ I- I-------- / O I ---------- <br />FLUORESCENT LIGHT FIXTURE I 1 X w PER SPECS I I <br />O EXHAUST FAN Gil S ITCH FOR > w <br />Q EXHAUST FAN/LIGHT COMBINATION / DI POSAL f <br />GARAGE <br />-- I o WP ' I I <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) I I 10 GFI GFI I I I <br />J I IRRIGATION I I I <br />CH CHIMES (OPTIONAL) I I GFI @ 44" I I I <br />I x Fo� <br />I GF <br />PB PUSH BUTTON SWITCH (OPTIONAL) - N I A.F.F. <br />DEDICATED ED I [D]B PUSH BUTTON SWITCH -DOOR BELLRECEPTACLE FORI <br />MICROWAVE RANGE -- FGFI I I I I <br />SD SMOKE DETECTOR <br />HOOD PER SPECS GII l i DWI <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) L _ _ <br />_ I I I I <br />TELEPHONE (OPTIONAL) I `� "' -� 1 � I I <br />�USB TELEPHONE/USB(OPTIONAL) - ITCHEN------------------------------ I -------------------------------------- -1 <br />© TELEVISION (OPTIONAL) <br />_-IL <br />/ 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. — REF COACH LIGHTS "'COACH LIGHTS <br />W <br />OR <br />OR <br />O THERMOSTAT - - - - `� r' PER SPECS <br />E AS ` / / / PER SPECS <br />E AS <br />ELECTRIC METER <br />OPWI ELECTRIC PANEL <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />Q\�� <br />. <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4"=1'-0" <br />FIRST FLOOR ELECTRICAL PLAN -A SECOND FLOOR ELECTRICAL PLAN -A <br />cv <br />6V <br />00 <br />r-- <br />C� <br />0 <br />CD W <br />CD <br />pQ t <br />v <br />c+� <br />m <br />to N s. <br />Z <br />N Q � <br />o>, <br />E c <br />y r <br />� m m <br />u w <br />� c � <br />C= <br />E <br />N <br />0 <br />N <br />ti <br />N <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. <br />Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W E <br />a oo M $ <br />N p <br />O <br />tl✓ Ntir�.� ik <br />fA M v � LL <br />w <br />�wLL w Q. <br />Z a <br />Z13 M8 <br />i 5N (_p <br />O� <br />O <br />. w <br />W CD <br />IL <br />IL <br />6 <br />Z �; N Z a <br />J <br />;n N <br />V <br />OU 0 <br />Z <br />W pp <br />U 2 v <br />Z .0 c+> <br />o <br />z 00 <br />z o <br />— <br />—J <br />rid <br />U) <br />— N <br />(n <br />V O <br />4--+ <br />W <br />—� <br />O w S <br />NLy N <br />U <br />LLJ <br />a n_8 <br />x� <br />Q Ch <br />so <br />oCID <br />ww <br />Mz <br />� <br />o <br />za <br />dE <br />0 <br />:i <br />O <br />2 <br />¢¢O <br />W 0 <br />=O VO <br />Z <br />o IEo <br />[V <br />a� <br />a= <br />p <br />p <br />�W <br />WW <br />� <br />w�.. 1- <br />M <br />< <br />z <br />m i <br />O <br />Z <br />� <br />� <br />J <br />d <br />Ii <br />oW <br />uJ <br />° <br />W <br />d <br />U <br />o <br />a <br />Nw <br />ti� <br />w <br />L <br />aY <br />�� <br />O <br />w <br />ar <br />�3 <br />>M <br />� <br />M <br />(0 <br />r <br />O <br />T <br />T <br />V l <br />m <br />LO <br />� <br />O <br />O <br />N <br />.� <br />o <br />IBC) <br />CV <br />Q <br />^ <br />r <br />ai <br />E <br />C`V <br />M <br />o <br />Z <br />Z <br />E <br />O y <br />m <br />a <br />U <br />0 <br />JOB <br />NO: <br />22-08302 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.