My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6306 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6306 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:38:48 PM
Creation date
2/19/2025 2:02:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6306
Location
Back Forty Lp
Contractor
Lennar Homes
Building Plans - Permit #
5932
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />I <br />a <br />2 <br />a- <br />t <br />0 <br />0 <br />J <br />t2 <br />LEI <br />I <br />N <br />a <br />N <br />N <br />E <br />l-- <br />0 <br />r <br />i <br />c <br />ti <br />N <br />N <br />N <br />S <br />a <br />0 <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />2 x 8 45' DIAGONAL — <br />BRACE(S) <br />BUILT UP PLWD. BUCK <br />SCRIBE (NOTCH) <br />BACKSIDE TO FIT ARCH <br />CONNECT W/ 8d NAILS <br />DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO PRODUCT <br />1x4 <br />1/2" DRYWALL <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />P.T. <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />— <br />1x4 <br />APPROVAL FOR CONN. <br />r` 1 X 4 <br />ix4 P.T. <br />X <br />C <br />LL� FURRING <br />3-1/4" LONG X 3/16"71 <br />0 <br />FURRING <br />3/16"� 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCON 16" O.C. & 4" <br />LiX8 <br />2X8 <br />BLOCK@ SPACING 11 <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/ MINI. <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH �� <br />1-1/2 DETAIL <br />1x8 w/ (2) ROWS 8d NAILS <br />3" DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />ix4 <br />1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />TO PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />(2) ROWS 3/16" x 3-1/2" <br />x 3-1/2" TAPCON @ 16" <br />O.C. & 4" FROM EACH <br />ix4 <br />❑ <br />TAPCON 16" O.C. & <br />@ <br />END w/ MIN. 2" EDGE DIST. <br />FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />2x DETAIL <br />21 /4" <br />DETAIL <br />STAGGERED @ 12" O.C. <br />3-1/4" DETAIL <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />1/4" MAX <br />iSOLID BLKG. AT TOP BTWN, <br />ARCH BLKG. & BUCK —� <br />2'-0" <br />SECTION <br />A -A <br />V. <br />8d NAILS AT 8" O.C. AT BUCK <br />(4)10d NAILS INTO \ — <br />2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />ARCH PANEL CUT HOLE IN O.S.B. FOR <br />POLY -CELL IN THIS AREA <br />(4)10d NAILS INTO 2 x 8 <br />BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />Ffi <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —� <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO K.) <br />2-0" <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />1 X 4 FURRING <br />BLKG. &BUCK l <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />PROVIDE 2 x 8 DIAG. BRACE B <br />VERT. BRACES WHEN HGT. OF <br />_ <br />BRACE EXCEEDS 24" <br />LEAVE A CUT OUT IN O.S.B. ON T <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />INSTALL WDW, SCREW <br />THRU OSB INTO 2 x 8 <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />ARCH DETAIL rK <br />B-B <br />SCALE: N.T.S. SS <br />1/4" x 31/4" TAPCONS <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />---2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN, OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX. 8 <br />FILL SOLID <br />CELLS.7 <br />#5 REBi <br />(TYP,) <br />STD. 90' <br />HOOK 0BOTH <br />#5" <br />NOTCH WEB AT <br />Li FIRST 2 COURSI <br />CAPACITY = 805 # FOR 1 STRAP <br />= 1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED W/ (3) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS / <br />2X6 TO 2X4 <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />SEALANT <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />* PRESS PANEL REINFORCING INTO PLACE. <br />�. ,: <br />;; °: •;. <br />- 6" MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />;: <br />_,,...: <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />,, :::.. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6'MIN. LAP <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE NOTE: <br />REMAIN FREE OF MORTAR. <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />SIMPSON <br />H2.5A w/ (10) <br />8d NAILS <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —� <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY KI <br />SCALE: 3/4" = V-0" SS <br />#5 CONT. TOP & MID <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 6'-0" <br />• • v� ►--6---�-a— <br />o <br />?- <br />GRADE <br />CV • ' 'P <br />th - Z <br />0 <br />\ • <br />(2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />00, <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION 0 <br />DO NOT DO THIS ♦♦ <br />♦ <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />�4*4* #5 REBAR (TYP,) ♦♦♦ <br />�� <br />3/4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />�R ♦♦ <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />O.C., 2 ROWS STAGGERED <br />♦ <br />• ��S�D. 90' HOOK (TYP.) <br />�� l ♦" <br />�4f. <br />2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />YP.) ♦♦♦ <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />— <br />[D <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />�'' <br />BOTTOM OF BAND <br />♦♦♦ <br />' <br />JOIST TYPICAL <br />♦♦ ±2" NOTCH�V�B @ FIRST COURSE <br />SIMPSON HGAMIOKTA @ 12" O.C. <br />♦♦ 4W' <br />w/ (4) 1/4x1 1/2" SDS SCREWS <br />♦ <br />�4s'.' <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />rHE <br />TITEN INTO K.O. BLOCK <br />:S ♦♦♦♦♦ <br />♦♦ �1 <br />FILLED CELL INSTALLATION Ze H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />BRG WALL TYPE —J-- j ALUM FASCIA <br />PER PLAN I I 1-3/4" TRIM PAINTED <br />I I SS NAIL w/ 5/16" HEAD <br />F CHANNEL, I DIA. @ 24" O.C. <br />FASTENED PER <br />NOTE 2 BELOW--- CONT VENTED OR SOLID SOFFIT <br />CONT 2X4 NAILED TO 2x BLOCKING NAILED TO TOP <br />BLOCKING w/ 2-12d NAILS (**) CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**} <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />- CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />WOOD w/ (3) 16 GA. 3/4"xl/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />SUB FASCIA w/ 16 GA. 3/4"x1/4" CROWN STAPLE @ EACH GROOVE <br />&RC <br />TRUCTURAL SOFFIT <br />ALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />V. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />/ 2k O�FRHq <br />+ [FNOrN <br />+ <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />* DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />PLYWOOD SHEATHING <br />BLOCKING AS <br />/ + REQUIRED TO <br />+ SUPPORT SOFFIT <br />ENTER <br />I , IfJJLJ' SEE ELEVATION ' <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION rM <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET' <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: <br />CFF cuFFT m Amr1 <br />z <br />O <br />U_ <br />O <br />w <br />U <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />a: <br />* <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />OVERHAN <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D, <br />M11 <br />• . ►.. ' #5 BAR <br />.. .• CENTERED W/ g <br />► ..' • ,ti ► IN TOP o <br />to .0. KNOCKOUT / <br />it CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN •• <br />AND SECTION DETAILS <br />CLEAN FILL .► • • • <br />DIRT 6 z <br />M <br />•, • STANDARD o <br />i 9N <br />#5 BAR IN 0' HOOK <br />r . <br />FILLED CELL, • -. <br />L99 <br />STEMWALL FOOTING SIZE AND <br />REINF. PERLAN AND STEMWALL <br />MONO TO STEMWALL FOOTING SECTION DETAILS <br />SCALE. 3/4 -1-0 <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />g <br />EXISTING FOOTING <br />(2) #5x6' IN CONC. <br />N <br />FILLED CELL <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />4" SAW CUT <br />A <br />SECTION <br />EXISTING FOOTING <br />SCALE: N.T.S. <br />RETROFIT <br />FILLED CELL DETAIL <br />SCALE: N.T.S. <br />C" <br />N <br />0 <br />N <br />C%A <br />oC d <br />Q O W <br />ro V CV <br />m x <br />.r c LA- a <br />In ro O <br />lA D N -% <br />rn o to <br />Q .d eV Y <br />a� ,y <br />.� ova <br />ro w w r' <br />c c= <br />-8-.= <br />V7 E <br />ro <br />o�"%N <br />�;���41;19PillfIif <br />f •, •K <br />F S45 <br />LU <br />�'• <br />t,.' .......•NPR <br />�'�' i/rl•ttlll�ll�\\\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Floride Building Code - <br />Resldentlal 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />W <br />cv E <br />Q N 8 <br />qR' � c <br />%00 <br />N inr--r,v 2 <br />M` QMv u <br />` -� U. W <br />u_ <br />J LL d <br />Z m -6;; ga <br />W. 0 <br />W 0aY 2rnrn m <br />ZLLM d r_ <br />IL <br />0 N <br />U <br />Z U y <br />W <br />z � <br />z <br />sr <br />(Z N <br />-- N <br />Z M <br />CD 9 <br />Cz <br />0 w s <br />Ln N <br />�N <br />c <br />Q <br />ID <br />� <br />n <br />zx <br />E <br />o <br />Q <br />0 <br />go <br />_ <br />g <br />oa <br />9¢ <br />Z <br />cq <br />N <br />U <br />o <br />2 <br />>z <br />Z <br />J <br />3 <br />b <br />g <br />w <br />z <br />o <br />W <br />$ 3o <br />o <br />E� <br />> LO <br />J <br />0 <br />E <br />Co Ln <br />M <br />00"IN <br />:3Q a <br />N <br />Cr N S <br />V) CO <br />CV <br />I.... <br />+-� 0 <br />LO <br />0 L <br />Y <br />m co <br />04 <br />CD <br />cp N <br />Lo <br />r <br />Q M <br />r <br />E <br />d- CD <br />z <br />r0 <br />C <br />7 y T <br />M Iv <br />= <br />a <br />N <br />" <br />0 ¢ o <br />_ <br />JOB <br />NO : 23-00513 <br />SCALE : AS NOTED <br />SHEET NO. <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.