Laserfiche WebLink
6'-5" <br />5' <br />5'-10"1 <br />N <br />zo <br />BEDROOM <br />#4 <br />BEDROOM <br />#5 <br />/' '___1 <br />0 <br />BEDROOM <br />#6 <br />6'-7" <br />OWNERS <br />BEDROOM <br />CV <br />. i;o <br />BATHROOM <br />1 1 -7 I 7 #2 <br />�. GFI <br />A <br />I <br />iAHU /\ <br />CS <br />L— �J <br />A <br />\ LIGHT AND <br />SWITCH IN <br />,69ATTIC <br />8 <br />5'-11 " <br />EDRO <br />I I I GFI IM <br />3'-9" <br />GFI& LAUNDRY <br />LOFT <br />F <br />1'_7" <br />/ cs <br />/ --- -- <br />--- -L <br />OWNERS <br />BATHROOM T01ST <br />^, r;Fi FLR ELEC <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATIONS A & B' <br />1 /4„ = 1'-0„ <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />SEP 0 8 2021 <br />VIRTUAL R E v tv �^; <br />Virtual Re\, IE?', a QSS`CI. Illo. <br />Plans Rev<ie p,/ roved <br />for compliance with tht! 2020 FL-D;` 7tb <br />Edition by Debra Anric Klahr PAN'2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />r <br />SWITCH Uj <br />° <br />4 1/2" <br />DOOR JAMB DUPLEX <br />OUTLET Zh <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o z <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />0 FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />4 TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-6 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />---a DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />} CLG MNT PREWIRE - FIXTURE BY OWNER <br />-�- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />41 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />O APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />A} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />Q SMOKE DETECTOR <br />r-U-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 - UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 ^ DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24-;g 24" VANITY LIGHTING <br />rm-=36:;-uR 36" VANITY LIGHTING <br />r-_-4848" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W1. INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />THERMOSTAT <br />011 SECURITY PAD <br />:LECTRICAL SPECIFICATION NOTES: <br />:LECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />;PECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />IXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />�.: <br />: ° a <br />e AR0 , <br />4 <br />fip <br />n, LO "'A) E <br />0 <br />010 <br />`- <br />W 0 <br />)M 7 <br />N -0 -0W <br />CO <br />E`� _CO <br />o 2 o <br />° �.0 Q <br />t <br />.� — <br />N <br />n` <br />W <br />L 0O Eri <br />a � <br />w 0 W <br />ow0hw -zw DQ W XQ~ fr z <br />of��2OaQZLU010 <br />aa <br />H <br />�a'0<122°o�Q¢ <br />�0z0oomz <br />�0W�WwW� <br />OZ <br />Q�a<ujK� Q <br />LL <br />❑ <br />0D<w00 0<LLQ <br />O LL <br />0 <br />0 <br />N <br />Z <br />O� <br />_ ti <br />F co O <br />a w M � <br />�LL ti <br />W <br />M <br />� IL <br />zv� <br />Z <br />Lu <br />W0 <br />O <br />d0` <br />t <br />t <br />I <br />t <br />I <br />� <br />, <br />I <br />t <br />O <br />o0000 <br />O <br />O <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />� <br />r <br />(h <br />M <br />f <br />O <br />O <br />CD <br />CD- <br />O <br />N <br />(0O <br />N <br />I <br />i <br />z <br />O <br />wo <br />> <br />r <br />A <br />lV <br />O <br />M <br />O <br />4 <br />O <br />t(') <br />M�CT <br />W vJ <br />Qz <br />O <br />zw <br />W <br />o O O_ <br />-1--r <br />0) 0 <br />V <br />UU� <br />Lo <br />z)zj <br />owo <br />_azaQ <br />r a <br />rl <br />F— <br />wLr)=mftw2L <br />N <br />w <br />p~O <br />�OM: <br />W <br />>- <br />0- <br />QED <br />■ ■ <br />CAI <br />0 <br />2-2 <br />zwo <br />� <br />a-ZLL <br />z <br />az <br />Z <br />U <br />� <br />0 0 <br />zA6m2't <br />z <br />z <br />z <br />w <br />J <br />LLI <br />0 <br />LAST PLOT DATE <br />April 21, 2022 <br />z� <br />J <br />2ND FLOOR <br />ELECTRICAL PLAN <br />