Laserfiche WebLink
SIMPSON HGAM11 <br />W/ <br />(4)1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & ( <br />1 /4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS—\\ <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />BACKNAIL w/ (2)16d NAILS --� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 MAX 9" <br />BACKNAIL w/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL <br />45' t <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO <br />BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAILY <br />2x4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8'-0" 0/C. <br />EXTEND AT LEAST 90% OF <br />EACH JOINT W/ (3) 10d <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />' <br />& (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3)10d & <br />FROM LEDGER TO <br />SILL <br />1/2" CDX PLYWOOD OR <br />d TOE NAILS @ EA. <br />BLOCKING <br />7/16" OSB SHEATHING <br />END <br />GYPSUM WALL BOARD <br />ATTACHED W/ 10d <br />GABLE TRUSS <br />NAILS @ 6" O.C. EDGES <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1/2" CDX PLYWOOD OR 7/16" <br />' <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />OSB SHEATHING ATTACHED <br />10dX3" @ 3" O/C <br />CORD ATTACHED W/ (2)16d TOENAILS <br />w/ 10d NAILS @ 6" O.C. <br />THROUGH CHORD <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />INTO 2"x6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2)16d <br />SEE STRUCTURAL NOTES <br />NAILING SCHEDULE FOR <br />DETAIL <br />2"x4" CROSS BRACE <br />NAILS <br />AND <br />SHEATHING <br />/ <br />APPROX. 8" FROM <br />RIDGE FASTENED AT <br />DOUBLE TOP PLATE <br />EACH JOINT w/ (3)1 Od <br />2x4 CROSS BRACE APPROX. 8" <br />& (2)10d TOE NAILS @ <br />FROM RIDGE FASTENED AT <br />EA. END <br />EACH JOINT w/ (3)1 Od & (2)1Od <br />(NOT REQ'D WHEN <br />/ <br />TOE NAILS @ EA. END <br />GABLE IS 4'-l" OR <br />2x FRAME WALL (SEE WALL <br />SHORTER) <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2)16d <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />TRUSSES FROM EA. <br />/ <br />\ \\NAILS <br />_\ <br />W/ 10d NAILS @ 6" O.C. EDGES <br />• AND 12" O.C. FIELD <br />END TYP. TOP & <br />BOTTOM ATTACHED <br />\\ <br />(2)16d NAILS <br />W/ (2)16d TOENAILS <br />\\ \ <br />2x4 "T' ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />FASTEN WITH 10dx3" 4" O/C SPACED WEEP SCREED — THE FIRST (4) ROWS OF TRUSSES <br />@ 1/2" 8" "J" BOLT 48" 0 C 2x4 T ON TOP OF PANEL <br />@ 48" O.C. :: <br />INSTALLED PER MANUF. x WEEP SCREED FROM EA. END TYP. TOP &BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"xi 1/2" SDS SCREWS TO <br />MOISTURE BARRIER SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />1/2"x 8" "J" BOLT @ 32' O.C. MINIMUM 6 FROM <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />PLATE SPLICES w/ 3/16"x2" PLATE WASHER <br />SIMPSON META12 w/ (7) <br />ALTERNATE SIMPSON MSTAM24 W/ (7) 10d NAILS <br />NOTE: IF EMBEDDED <br />1Odxl 1/2" NAILS AT EA. <br />& (4)1/4"x21/4" TITEN @ 4'-0' O/C ALIGNED WITH <br />STRAP MISSED VERTICAL <br />SECTION <br />TRUSS VERTICAL WEB (24" <br />1 <br />GABLE WEB SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />O.C. MAX) w/ MIN. 4" <br />1Od NAILS & (4)1/4"x2 1/4" SCALE: N.T.S. <br />S5 EMBEDMENT IN KO BLOCK <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J <br />N <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />M <br />X-BRACING, AND TOP <br />" <br />SEE STRUCTURAL <br />CHORD BLOCKING <br />N <br />NOTES AND NAILING <br />INFORMATION <br />`� <br />� <br />`° <br />SCHEDULE FOR <br />SHEATHING DETAIL BACKNAIL w/ <br />1 1 <br />1/ " <br />(2)16d NAILS <br />WOOD TRUSSES <br />iO <br />2"x4" CROSS BRACE <br />APPROX. 8" FROM <br />2x4 RAT RUN BRACING <br />RIDGE FASTENED AT <br />AT 24" O.C. ON TOP OF <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 <br />10d & (2)10d TOE <br />TRUSS SPANS <br />NAILS @ EA. END <br />ATTACHED W/ 2 -16d <br />AT EA. TRUSS JOINT <br />2) 2" x 4" LAMINATIONS W/ 1 ROW <br />( () <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW <br />" <br />(3) 2 x 6 LAMINATIONS W/ (2) ROWS OF <br />2x4 PANEL BLOCKING <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />@ 48 O/C FOR THE 2 1 <br />() 6d NAILS <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L - 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />FIRST (4) ROWS OF <br />O/C w/ (2)16d <br />TRUSSES FROM EA. <br />TOENAILS @ EA. END <br />NOTES: <br />END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />BOTTOM ATTACHED <br />MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />w/ (2)16d TOENAILS <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 314 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) <br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />NON - LOAD BEARING LOCATIONB.OU.C. SAMEMMON INUM ER OF ROWS, SAME LS. (ONE INTO EACH OUTSIDE <br />SPACING) <br />OF <br />rD ) <br />SEE TYP, WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. S5/ <br />11NIMUM 2x <br />'ROSS BRACING <br />3EE PLAN FOR <br />OCATIONS) TOENAIL i <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />2"x4" MIN SFF M/S5 <br />CROSS BRACING DETAIL J <br />SCALE: N.T.S. S5 <br />GABLE END BRACING DETAIL <br />12" <br />ISH SCHEDULE <br />TTTACHMENT <br />? SYP BLK'G @ 16" O.C. <br />1 x 0.131" <br />AILS EA. SIDE <br />2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. CJ'CJ <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />MINIMUM (2)16d PER JOINT <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 10d NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />-2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING 2x4'7" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE 1" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ NAILS @ 4" O.C' <br />TYPICAL <br />GABLE TRUSS WEB -� <br />SINGLE "L" BRACING DETAIL s <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />DBL. TOP PLATE SIMPSON SP2 w/ (12)10d 2 2"x8" "L" BRACE J11 <br />2x4 LEDGER (MATCH BOTTOM CHORD NAILS AT EACH STUD FASTENED WITH (3) <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) 16d PER SIDE <br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE('_7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. <br />REV. 06.08.22 S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, 8d @ 6"0/C <br />IF >9" SEE 10/S5 r-WOOD TRUSSES <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />SIMPSON HGAM10KTA W/ (4) <br />E ES AND 12" O.C. FIELD <br />1/4"xl 1/2" SDS SCREWS TO <br />JACK TRUSS <br />BLOCKING & (4)1/4"X2 3/4" <br />SEE PLAN FOR <br />TITEN TO CMU <br />---- 11',Lt__CONNECTION <br />2x4'T' ON TOP OF PANEL--� <br />BLOCKING, FASTEN WITH 2X4 BLOCKING W/ <br />1 Odx3" @ 4" O/C (2)12d TOENAILS <br />SECTIONK" 9.L_ <br />SCALE: N.T.S. SCJ <br />MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/(3) 10d x 3" AT I = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. @ NON - LOAD <br />BEARING LOCATION (UNEVEN CLG.) rE <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-0" <br />T-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGAIOKT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />`CONT. BEARING <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />I V-0" MAX. <br />tiq <br />Cr <br />0 <br />U <br />9- <br />2 <br />�q L <br />CORNERJACK <br />Y <br />4 <br />� <br />a <br />W <br />z <br />0 <br />U <br />HIP FRAMING REFERENCE PLAN <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 n I f- CONTINUOUS BOTTW CHORD BRACING 2X4 MIN. <br />ON <br />ON <br />III�I <br />AEINo <br />a <br />g <br />NOTE: ZTOP CHORD 2X4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS <br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING <br />2)'T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0' O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />en <br />= %, <br />N <br />is <br />� w � <br />> W <br />O = <br />i p <br />U G� O_ <br />rO V CV <br />"m ac <br />d- <br />CIO r= <br />fR .a N L <br />N O fq <br />°i <br />d c� � <br />2 d <br />> b .G C <br />U.3a <br />3 <br />� w rz <br />d <br />�o <br />N O-� <br />E <br /><O G <br />a U <br />0 <br />wX1l�li <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 71h Edition. Enginee(s signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />1- o a g <br />! 00 � �i <br />h tgnr�a► <br />y My su <br />a m LL u-�: w a <br />Z -9rn d <br />;04 i0 <br />W/J�91 <br />m W <br />. <br />LL= <br />C14MZdJ <br />Z OU U <br />W13 <br />� <br />z <br />Z n <br />g <br />Q <br />a <br />z <br />N <br />cf) 5 <br />a--r �, <br />�U <br />0 w g <br />N [_ N <br />t/1 <br />U d <br />iv <br />10� <br />U � <br />c <br />¢ �' <br />• <br />� <br />S <br />O <br />�J <br />z <br />W <br />z <br />M <br />J <br />0. <br />q <br />ri <br />E <br />z o <br />oLL <br />» <br />E <br />�_ o <br />' <br />Z® <br />. <br />X O <br />o <br />y' U <br />zM <br />�S <br />�W <br />U> <br />4z <br />O U <br />aN <br />hm <br />mp <br />t5 <br />z <br />m J <br /><p <br />s`" <br />-Z <br />8 <br />C <br />os <br />2. <br />g� <br />az <br />W <br />y <br />m <br />a � <br />LL <br />$z <br />ll� FWF <br />i� <br />0 <br />1116 <br />�.}0 <br />V <br />rn <br />� <br />m <br />0 <br />^, <br />i <br />� <br />N <br />LO ° <br />CV <br />LO <br />CT g <br />CL <br />N <br />CID0 <br />N <br />-lid <br />v <br />04 <br />m <br />� <br />N <br />T <br />Q <br />T <br />E <br />.9' CD ` <br />N <br />Z° <br />M <br />r <br />E Ch Iv <br />a <br />U ¢ p <br />JOB <br />NO: 23-00511 <br />SCALE : AS NOTED <br />SHEET NO. <br />S5 <br />