My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6322 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6322 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:16:21 AM
Creation date
2/19/2025 2:03:46 PM
Metadata
Fields
Template:
Building Plans
Street #
6322
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6032
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I <br />I <br />I <br />I <br />------------------------------J <br />CROSS BRACING DETAIL (TYP.) 1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. Cg <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />IT[ IT[ 14 <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. —� 1 A <br />�—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />- >E—'- <br />L. �y <br />1r Arr <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />, , .,,�., .. <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 42 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT—� CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />12" <br />*� <br />w <br />4" <br />Z <br />Cn <br />a <br />N <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />Iw <br />4 �� <br />Z <br />_U <br />W/ #3 STIRRUPS AT <br />c� Z <br />4'-0" WHEN DEPTH <br />, <br />T <br />EXCEEDS 30" <br />LOWER OR <br />GARAGE SLAB <br />1'-4" <br />SEE PLAN <br />LARGE <br />STEP <br />DOWN <br />17 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT, <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />USSES <br />(2) 12D NAILS —' <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />HIP <br />G.T <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />—\ PLAN <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />4" <br />#3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE 7 WHEN DEPTH <br />FOUNDATION PLAN EXCEEDS 30" <br />BADE <br />N Z <br />1 r�rr <br />ENTRY PORCH SILL �4 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN <br />REQUIRED INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 <br />W/ (1) #5 CON <br />REQ'D @ MID <br />I <br />I <br />fr -- <br />II <br />-__ <br />r <br />i <br />I <br />II <br />I <br />I <br />I <br />I <br />IDA <br />I <br />I <br />ll <br />T. FILLED CELL VERTICAL EACH <br />SPAN MAX 6'-8" CORNER FILLED <br />Ak MAX 3 SOLID. SEE ELEV. <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY- <br />-- <br />v <br />SLAB PORCH SLAB SEE <br />LEVEL FOUNDATION PLAN <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />—SEE ELEV. FOR <br />BLK HGT. <br />—#5 REBAR CONT <br />@ SLAB LEVEL <br />—EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ z <br />CONTRACTOR TO INSTALL SEE CUT #3 STIRRUPS AT 4'-0" '- <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />1-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL �16 <br />SCALE: N.T.S. <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />SIMPSON HUC410 <br />— — — — — <br />— <br />I <br />SEE PLAN <br />CENTERED AT <br />w/ (14) <br />FOR CANT. <br />SPLIT TO TIE <br />16d INTO HEADER & (6) <br />BEAMS TOGETHER <br />I <br />10d INTO BEAM -SEE <br />I <br />I <br />I <br />ROOF PLAN FOR MORE <br />1 <br />INFO <br />I <br />1 <br />SEE FLOOR PLAN FOR <br />I <br />I <br />COLUMN SIZE & BASE <br />I <br />I <br />I <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN <br />I <br />CONNECTION INFO <br />I <br />I <br />REQ'D ONLY WHEN <br />FOR COLUMN SIZE <br />— — — <br />— <br />INDICATED ON BM. <br />& ADDITIONAL INFO. <br />— — — — <br />— <br />— — — — — SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION <br />A <br />INDICATED ON <br />OPTION <br />B <br />CONNECTION INFO <br />OPTION C <br />SC EDULEIPLANM <br />EXTERIOR SHEATHING COMMON BM. TO POST ATTACHMENT KA� <br />ATTACHED PER SEE ROOF PLAN <br />NAILING SCHEDULE FOR BEAM SIZE & <br />CONNECTION INFO. <br />ti 2x4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />r - SIMPSON MTS12 w/ <br />- (14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A F__� A <br />SEE PLAN FOR <br />_J <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />CORNER I I— SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />im <br />SIMPSON (2) <br />HTS20 w/ (14) <br />10d NAILS <br />TYP. U.N.O. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = V-0" <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />' — - -- RUSS/ <br />J10-P WALL <br />-. - EE PLAN <br />y" CDX PLYWOOD OR 3/16" O.S.B. MIN. (2) 2x8 #2 SYP <br />SHEATHING REQ'D FROM BOTTOM HEADER. SEE Q/S4 FOR <br />OF WALL TO ROOF SHEATHING h REQ'D CONNECTIONS <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES <br />i 2x4 #2 SPF STUDS @ <br />��-'— 12" O.C. W/ USP SPT22 <br />f� " @ BASE & SPT24 @ <br />�, TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />%8' EPDXY ANCHOR OR <br />2„ J-BOLT OR Y TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />SEE PLAN MAX. MIN. 6 EMBEDMENT <br />24" STEPS <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS ° <br />FORMED & POURED MAIN HOUSE <br />W/ (1) #5 EACH STEP SLAB <br />a4. <br />4 <br />(2) #5's CONT. T&B <br />\T <br />. w/ #3 STIRRUPS AT <br />a 4 a 4'-0" WHEN DEPTH <br />a ° <br />4. -- EXCEEDS 30" <br />NZ <br />GARAGE OR <br />LOWER SLAB <br />i <br />SEE PLAN - = - <br />1r Arr <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />e+3 <br />N <br />0 <br />N <br />C" <br />LZ <br />N o <br />��_ <br />x <br />u Cn <br />11 <br />�Zmx <br />�",CL. <br />�p <br />to O !a <br />N Y <br />>Es� <br />E <br />o <br />0 <br />• <br />vl� <br />v <br />� 0 F 6 S S j0 <br />w l/1111111rIt���``�\ <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />CV <br />$_ �_� <br />0 N °° <br />fn � <br />to to r` r 816 <br />--Crn Ci 52 <br />Z <br />cl <br />� <br />re C iG <br />W <br />m 0 <br />W�pj°; <br />w <br />M <br />IL <br />..� <br />V N O C¢) y <br />Z <br />W ❑ El <br />z <br />J <br />Co <br />-� <br />O <br />N <br />c <br />W J <br />�.- <br />ago <br />�0 <br />o <br />w <br />ch <br />J <br />20 <br />z <br />� <br />L{,, <br />O <br />2 O <br />Y N <br />z® <br />as <br />�xa <br />Z <br />o <br />`� <br />t <br />W� <br />� <br />m a <br />�a°� <br />�x <br />a� <br />z <br />'S J <br />�m <br />�z <br />W <br />N <br />S <br />°offo <br />LL <br />T. <br />'f <br />�s <br />CCD <br />0 <br />C) <br />2 <br />.J <br />L6 <br />0 <br />m <br />c� <br />>` <br />N <br />0 <br />N o <br />Cr J <br />N <br />�.. <br />N <br />+� O <br />LO <br />�. <br />a..+ <br />O Y <br />LO <br />.0U t-0 <br />O <br />m O <br />N <br />T— <br />Q M N <br />T <br />ui <br />M <br />t 0 <br />M r <br />6 <br />z <br />E <br />a <br />v � ¢ o <br />JOB <br />NO : 23-00511 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.