My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6322 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6322 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:16:21 AM
Creation date
2/19/2025 2:03:46 PM
Metadata
Fields
Template:
Building Plans
Street #
6322
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6032
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STAIRCALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />42" KNEE WALL WITH <br />1x8 CAP &CASING <br />36" H. CONT. B <br />GRASPABLE <br />RAILING <br />1x8 CAP & <br />CASING <br />(3) 2x12 <br />STRINGERS 2 <br />1 <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMING <br />(2) 2x HDR. <br />REQ'D @ ENI: <br />LANDING FOI <br />STRINGERS - <br />CONNECT TC <br />UG <br />i14 <br />�13 <br />CO) ,, <br />12 <br />i <br />�10 <br />,1W %g STORAGE ;o o <br />UNDER <br />i7 STAIRS 00 <br />� "6 1x TREAD <br />/ TYP. <br />�4i 5 1xRISERS <br />(TYP.) <br />3 2x FRAMED 2xFRAMED <br />N <br />WALL WALL <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />"sIN <br />•SIN <br />CONT. HANDRAIL <br />42" KNEE WALL RETURN TO <br />WITH 1x8 CAP <br />& CASING V1/A L L D E T�Al L <br />DE PLYWOOD <br />DECKING .•..•. � � ,��„� <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-0" <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest deer height within any flight of stairs shall not exceed the smallest by <br />more than 318 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the Intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the dear width of the stair. <br />Nosing*: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/ inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways, The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handralls: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 Inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less then 11/2 inches between the wall and the <br />handrails. <br />Grip-aize: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH <br />FLOOR SYSTEM <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />V-0" MAX LANDING LENGTH <br />(i) <br />TYP, @ <br />CONERS <br />E6 <br />3 <br />Sim. w/(1) <br />MSTAM36 <br />FLAT STRAP <br />J <br />S6 <br />TYP. <br />3 <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />DRYER VENT- <br />THRU ROOF. <br />HANSON BOX @ <br />36" A.F.F. <br />LAU N <br />8'-0" FLAT CLG. <br />TILE <br />12' <br />107 <br />TB 60" X 36" <br />9'-6" <br />H1 ,25 SH D2 <br />r=raor=c <br />- JSHOWER <br />O <br />' <br />FI BERG LASS <br />16,-4" <br />SURROUND <br />31�TP <br />-°T <br />_ - <br />5'-5" <br />OWNER'S <br />SUITE <br />- BATH --! <br />" ' CLG.' 2668 ! <br />8'-0" FLAT CLG. <br />2068, <br />TILE <br />' _1 <br />CARPET <br />BF ` <br />- <br />G.T. <br />4SH <br />C30 <br />o o <br />R&S - t'l;iz-1 <br />I I <br />I WIC �gce�55 <br />COI 8'4" FLAT CLG. 2068 <br />�I CARPET 2668 <br />TILE TO 7' o x'6�� CHASE <br />A.F.F. <br />Y <br />I <br />BEDROOM 3 <br />2 I <br />8'-0" FLAT CLG. <br />4SH <br />'-0" T CLG. ° rn m CARPET <br />TILE TB 2468 X I _� <br />BF I L q <br />3'-0" T-3" I r <br />2668 - co G.T. <br />61-7 2' A" 10'-4" <br />+ -2 26680 I �, <br />U. - --- <br />D. u- - <br />W I 00 42" HIGH 1/2 I I I I I ( I ( I I I I I I <br />45 WALL W/ 1x I I I I I I I I I I I I I I I _J <br />CAP <br />� W' � DNI I I I I I I I C I I I I I I o}'ogg <br />1161 114113112111110 9 18 I 16 15 14 13 12 11 cG <br />24 SH <br />c00o 22 H1 O I <br />N I D1 D2 <br />fn I I <br />T-8" V-0.1 in 2I <br />4068 BF I I <br />BEDROOM 2 ' � --- -----� <br />8'-0" FLAT CLG. <br />CARPET _ G.T. <br />I I I <br />22 j I <br />D1 I I <br />co 4068 BF I I I <br />- - - ---- <br />I 1 <br />I <br />25 SH 1 <br />D2 B RESS 22 j <br />I H1 D1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I 1 <br />I I <br />I I <br />I 1 <br />I I <br />I I <br />L--------------------------------------� <br />10'-2" <br />25'-0" <br />R <br />f_ <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />O <br />CD <br />N <br />4 <br />r <br />WITITO <br />REV 10.1.20 CAR <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'4" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />' WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.' <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />" WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS"' <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 251 <br />S. H. <br />13 <br />20X38J <br />18}X37J <br />S.H. <br />14 <br />20 X 50 1 <br />18 J X 50 <br />S. H. <br />15 <br />20X63 <br />18JX62i <br />S.H. <br />16 <br />20X72 <br />18JX71} <br />S.H. <br />11-12 <br />271/4X26 <br />26X25J <br />S.H. <br />1H3 <br />271/4X38J <br />26x371 <br />S.H. <br />1H4 <br />27JX501 <br />26x50 <br />S.H. <br />1H5 <br />27JX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37JX26 <br />36JX251/2 <br />S.H. <br />23 <br />37 J X 38 ii <br />36 J X 37 3/4 <br />S. H. <br />24 <br />37 J X 50 1 <br />36 } X 50 <br />S. H. <br />25 <br />37 J X 63 <br />36 } X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 J X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 } <br />S.H. <br />33 <br />54 X 3811 <br />52 J X 371 <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 } X 62 J <br />S. H. <br />36 <br />54 X 72 <br />52 J X 71 J <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91 /4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />FLITCH LATE <br />P <br />Follow Q/S4. See Plan for <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />O <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />( <br />+28.3 / -37.0 <br />+26.6 / -29.1 <br />+26.6 / -33.5 <br />1 <br />SEE SN SHEET SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />SECOND FLOOR PLAN - A <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the Interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed, Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA <br />2ND FLOOR LIVING AREA <br />721 S.F. <br />807 S.F. <br />TOTAL <br />GARAGE <br />LANAI <br />ENTRY <br />1528 S.F. <br />397 S.F. <br />60 S.F. <br />30 S.F. <br />TOTAL SQ. FT. <br />2015 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />R-11/R-13 KRAFT FACED <br />sw <br />� o <br />C" <br />::L� Lu <br />NI <br />w o <br />tom. <br />_19C <br />C.7 C2_ <br />°DX <br />H f0 O <br />�n cc is <br />� <br />4 N Y <br />is y 4j w <br />1= = o <br />��.e <br />E <br />o <br />0 <br />�\�Jlkllll Hill/ B <br />_- Y) <br />tX <br />`\\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition, Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />,mSS,, E <br />O <br />0 <br />N <br />04 <br />6g'N5� <br />w <br />B � cc <br />u" <br />06 <br />dJ <br />V, J <br />M 0 Ys LL <br />C0 <br />�eLLLL SS 4 <br />Z <br />rig <br />en4 <br />W <br />$ OO <br />m <br />W <br />Z <br />(S2T . <br />'2 & Z3 <br />a <br />a o <br />Z <br />W <br />uu)) <br />❑❑ <br />CD co.) <br />N lh <br />z o <br />a <br />A <br />M <br />--d <br />Il.. <br />.0 <br />o <br />0 <br />g <br />wLn <br />tJ I <br />C N <br />r <br />0 <br />Q Nc <br />a <br />ri <br />Eo <br />E <br />wLLze <br />o E <br />�. <br />pU <br />Iz <br />Z <br />cD ro <br />°d i <br />I z <br />m0 <br />ZVi2 <br />� J <br />w� <br /><q <br />� w <br />�Z <br />S <br />�S <br />W <br />�LL <br />� <br />zl� <br />c <br />� <br />J <br />>LO <br />o� <br />m <br />� <br />N <br />M <br />N <br />LO <br />Cr <br />g <br />N <br />U) m <br />N <br />I- <br />o <br />0 <br />r. <br />x <br />N <br />m o <br />Cr) <br />N N <br />t.C) <br />.- <br />Q <br />M CV <br />r <br />E <br />N <br />6 <br />f0 <br />E M <br />y T <br />a <br />0 ° <br />i1i <br />M <br />a o <br />CD <br />JOB <br />NO: <br />23-00511 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />