Laserfiche WebLink
DISCONNECT <br />WP <br />GFI <br />Ll <br />3 <br />zZ, <br />FAMILY �. <br />�o ROOM / C C <br />1 F / <br />6-7" \ <br />\\ \ 6-5" <br />I <br />OWNER <br />SUITE <br />REF FI <br />KITCHEN -00 <br />GFI AT_T\ 30" A.F.F. GFI — <br />77 oI FOR <br />4'-3' i - HOOD <br />0 <br />A w TO Cio I GFI GFI <br />o ISP / <br />w o a, . J ® OWNER 1' 5" N <br />B " o �n' BATH <br />4 � � <br />DINING /� ---- <br />ROOM GFI AT u I I 1 GFI <br />\ 30" A. F F. ° _ _ DIN <br />\ 3�_8 3 _0 4' 0 . <br />I A <br />i4 (4 � GFI \ I <br />_ 2'_7" <br />GFI <br />j 2,-3„ I <br />° GFI ANTRITILITY <br />GF✓ 0 FI A <br />A A A I I <br />PWDR <br />BATH G <br />3 <br />'-2" - — <br />—� — C <br />TO 2ND <br />FLR ELEC <br />kfrFl <br />*0 <br />' LINE OF <br />FLOOR <br />LIGHT AND <br />ABOVE <br />SWITCH IN 0 <br />_ <br />rT � —ATTIC <br />I L_--J <br />\ <br />ELEC <br />I PANEL <br />FOYER <br />48 <br />TfW u <br />GFI N <br />I C <br />4'-5" ENTRY <br />110V CLG <br />q ! —MNT. <br />OUTLET <br />GFI <br />i GF <br />i <br />i <br />r------ --------------i <br />q ! I <br />I <br />Q <br />i <br />i <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /411 = 1 1-011 <br />METER <br />LINE OF ROOF <br />— —.1 <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /411 = 11-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 10 <br />#12 copper to 20 amp ckts <br />200 AMP <br />0110 <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAI N <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />OUNDING PER 250.50 AND <br />F <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />SEP 0 8 2022 <br />VIRTUAL R , <br />virtual <br />ompIE�e 202E F � <br />Plans Review c <br />3C <br />for Compliance With tt e <br />Edition by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />r <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET in <br />TRIM--- <br />BASE--- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />- 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />{- CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />WALL MNT FIXTURE <br />NOTE: <br />30 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />60 50W MR16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />10 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9724:R 24" VANITY LIGHTING <br />9;;F 36 :;;R 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p,� DOUBLE FLOOD LIGHT W/ COVERS AND <br />ti 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />IMKF MASTER STATION <br />711111iZI ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />EM A/C REGISTER <br />(1) THERMOSTAT <br />0 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />3.. <br />,. <br />N <br />co <br />G <br />: a on. v . <br />LO <br />to <br />s <br />tCo <br />o <br />icln <br />' <br />��- <br />w <br />k : <br />_ <br />O0 <br />w <br />0 <br />z <br />�VI <br />W <br />o (D O <br />L c '0M 0 <br />8 <br />co 5 <br />NU <br />ay <br />-0-0- <br />M <br />W O u o <br />.}. QoQ <br />O LL 8 c Q <br />S <br />�N <br />N <br />w a� 2 <br />EM m <br />L. <br />a 'D <br />W <br />wN <br />w <br />wul w J w -0 Z <br />(D w <br />< Q V <br />Q <br />Wj�_j oo�xc,)LL000_j0 <br />:OXJz0�OZ�00,Q~ <br />0 <br />F <br />O <br />00 Z <br />C)V)W OxO000Z <br />Ow0-wfnwww5ww <br />W�2KEZOWUCQ- <br />� J <br />W <br />¢F_< <br />OQ 0 0 C'ZQ <br />LL <br />� <br />O <br />O <br />Z CN <br />O �. <br />5; (n O <br />I:) F-7`c`YMO <br />aJ L0 <br />W L0 <br />QUQ00 <br />Z F- <br />Z <br />ww <br />J o <br />O <br />N <br />N <br />0 <br />N <br />h <br />N <br />0 <br />0 <br />00. <br />(0 <br />r <br />00 <br />O <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />C) <br />CO <br />un <br />o0 <br />A <br />e. <br />T - <br />N <br />O <br />cM <br />N <br />' - <br />0 <br />- <br />0 <br />A <br />0 <br />CDO <br />— <br />0 <br />W <br />0 <br />� <br />c <br />LO <br />j <br />o <br />0 <br />N <br />0 <br />co <br />Cl <br />It <br />0 <br />LO <br />0 <br />O <br />0 <br />rl- <br />T- <br />C <br />CO <br />Z Z <br />z O <br />O <br />_ <br />WL <br />wCD <br />w <br />> <br />4—a <br />Uo-o <br />F-O <br />a <br />LO <br />Zw�¢ <br />ZW <br />r�nmOZ <br />v <br />Z J <br />f'V <br />00 <br />�Mzw <br />M <br />Z Z LL <br />CV <br />w N <br />O-32z <br />Q <br />Ua} <br />n <br />LOZ Z <br />I..L <br />z <br />Z <br />�Qo <br />C.) <br />a <br />OU <br />O <br />W <br />� <br />1z <br />z <br />A6 <br />w <br />w <br />J <br />W <br />LAST PLOT DATE <br />>T-- <br />0 <br />Apr. 26, 22 <br />z <br />0 <br />1 ST & 2ND FLOOR <br />J <br />ELECTRICAL <br />PLAN <br />A <br />