Laserfiche WebLink
FLASHING REQUIREMENTS <br />WEATHER RESISTIVE <br />FLASHING AND SEALANTS FOR EXTERIOR WINDOW AND DOOR OPENINGS SHALL COMPLY WITH <br />BARRIER <br />WINDOW UNIT <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />SECTION R703.4. <br />DOOR ROUGH OPENING <br />SLOPE <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />R703.2 WATER -RESISTIVE BARRIER. ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND <br />= <br />0.3 in: 12.0 in <br />BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED WATER -RESISTIVE <br />WOOD FRAME CONSTR. ::' _ <br />{ <br />(0.6 cm: 30.5 Cm) <br />BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELT OR <br />SELF -ADHERED FLASHING „t <br />BY LAPPING DOWN __ _ <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />ELF -ADHERE A <br />S D FLASHING S H I N G <br />MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER <br />OVER RIM JOIST AND UP •'' <br />THRESHOLD OF DOOR AND RETURN <br />LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT <br />WALL BY 6 IN. = _ <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />KIN <br />OR EQUAL WEATHER PROOF CAULKING <br />EXTERIOR <br />PRODUCTS DETAILS <br />LESS THAN 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATEDA T PENETRATIONS AND BUILDING APPENDAGES I <br />U G GES N A <br />CEMT. FIN. <br />MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN <br />"-..........SELF-ADHERED <br />FLASHING <br />BUILDING PAPER <br />SECTION R703.1. THE WATER -RESISTIVE BARRIER IS NOT REQUIRED FOR DETACHED ACCESSORY <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />BUILDINGS. <br />SEAL TOPS OF JOISTS <br />WIRE LATH <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />UNDER DECKINGSUBIFLOOR <br />SEE DETAIL WP07 " - <br />R703A FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED <br />E <br />RIM JOIST <br />Detail Instructions <br />MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />Refer to the number marked as in each detail that corresponds to <br />PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT <br />COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT <br />the numbered items in the lis of instructions below: <br />EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS <br />APPROPRIATE FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN <br />2 <br />O <br />1. Install self -adhered flashing in order as shown by numbers <br />EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />INSTALLED AT THE FOLLOWING LOCATIONS: <br />SELF -ADHERED FLASHING <br />W P <br />SELF -ADHERED FLASHING <br />W P03 <br />3. Self -adhered flashing can be substituted for building paper <br />1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE <br />EXTERIOR DOOR WITH DECK - SECTION <br />A <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />4. Split the release paper using the ripcord (Split release on <br />WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT <br />EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing material <br />9 q P 9 <br />MORE OF THE FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR <br />WEATHER <br />THRESHOLD OF DOOR AND RETURN <br />FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING; <br />(6" X 6" Minimum) <br />FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S <br />rRESISITIVE <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />FLANGED WINDOW <br />rw <br />INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. <br />1 BARRIER <br />OR EQUAL WEATHER PROOF CAULKING <br />(SEE DETAIL WP01) <br />6. Fold as shown by arrows <br />WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE <br />TAPE <br />EXTERIOR <br />Y_ <br />„:;:;- " SCORED <br />7. Angle of corner may vary, adjust folding of the flashing <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL <br />SHEATHING <br />RELEASE PAPER <br />accordingly to fit tight to corner <br />BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE <br />�u rt " <br />inwir (MEEIN7LEO NANOOW) �'{:"i: l�.Z-: <br />irGf'• :iis: <br />�7 •:�: <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />r (BEFORE FOLDING, SCORE <br />POSE <br />RELEASE PAPAS TO SHOWN) <br />ADHESIVE AS SHOWN) <br />8. Mechanically necessary fasten as n <br />EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER FOR SUBSEQUENT <br />DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR <br />,%": <br />VERTICALLY FROM <br />PROTECTION AT THE HEAD AND SIDES. <br />'t: <br />"x •`: <br />n:r •r^ ., <br />_ ^'•°rr•,••n••• WEATHER <br />''' " :" RESISITIVE <br />2 ,:;�,;;` T5 <br />' <br />BorroM of <br />THRESHOLD <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN <br />PROFESSIONAL. <br />h �: <br />BARRIER <br />SECTION -A (SEE DETAIL WP02) <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. <br />:rr+K <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/ AAMA 200, FMANVDMA 250, FMA/AAMA/ WDMA 300 <br />SELF -ADHERED FLASHING <br />O <br />OR FMA/AAMA/WDMA 400. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR <br />2 <br />HEAD FLASHING TIE-IN INSTRUCTIONS: <br />= <br />STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />1. Cut, fold up & temporarily secure weather resistive <br />`: <br />SELF -ADHERED FLASHING <br />5 <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. <br />barrier above header to allow for flashing <br />' " <br />installation <br />4 <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />SEAL TOPS OF JOISTS <br />6 <br />S. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />3. Fold weather resistive barrier back over head <br />2 <br />UNDER DECKING <br />DETAIL WP07) <br />2 <br />7 <br />6. AT WALL AND ROOF INTERSECTIONS. <br />flashing and seal with tape <br />(SEE <br />7. AT BUILT-IN GUTTERS. <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />WPM 1 <br />SELF -ADHERED FLASHING <br />WP05 <br />SELF -ADHERED FLASHING <br />WP06 <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING � <br />Ground I�- <br />SHEATHING <br />._. n` {{ ;, <br />7/8" Cement Plaster <br />7/8" Cement Plaster <br />REFER TO TECHNICAL <br />%>i`,:''"'*% az:,. <br />1 <br />in accordance with <br />in accordance With <br />LETTER ON CHEMICAL <br />"i:Y "......;.:>•iz•• <br />Water Resistant Barrier <br />ASTMC926 <br />ASTMC926 <br />COMPATIBILITY • <br />SELF -ADHERED FLASHING • <br />'`'ss` r=`».r;i:... <br />Lath <br />Felt backed metal <br />Felt backed metal <br />SELF -ADHERED FLASHING <br />Sheathing <br />lathe in accordance <br />lathe in accordance <br />�° <br />"• ' <br />PATCH <br />with ASTMC1063 <br />with ASTMC1063 <br />.:.ss:..0 v:: .:xr..:::: • <br />e <br />.Stucco <br />Building Paper <br />Building Paper <br />:vs:•:xr vvr. r . liuia.x�•4'x°'•• <br />«x <br />- <br />-- <br />•4 <br />4 <br />............. N <br />............. / <br />7/1 6 OSB <br />-::::;::;;•�::::.:.:.::::::::_:......_J.....,::::::::-::•::::x.:::::::::._...:ls,;;;;;;;;;:i:.....:::.:::::::::::::;:::•_,_::... <br />• <br />a <br />............ sheathing <br />sheathing <br />:....:.. <br />• <br />SELF -ADHERED FLASHING <br />••:_::::::::x.,: .---...... .:six.; .....,••vx....:....... ........... <br />............:............._..... ............ ........::• . CIF <br />::::^' <br />....... ...........v :vn::(wAx eh, <br />•I ' • <br />/ <br />:•r«� . <br />:., . <br />. . ........vJ.•L:t�EG..:_," <br />:::.:.v::::r«•,•:;:..,::::•. :,:.:.-r;:;;;•• <br />::« ; •:{rri;%N:aN; ::.-z,.','.''' �...:":aii:s ' SELF -ADHERED FLASHING <br />Foundation Wall • .: ' <br />............. <br />Metal <br />• 2 e•. <br />.,:::. <br />SELF -ADHERED FLASHING <br />,� <br />• ; • ' •., . .: ... <br />• <br />............. .:. Flashing <br />_ <br />NAILING FLANGE <br />1 <br />= <br />3" MIN <br />2 <br />, • <br />: •• • ' <br />4: A = <br />Weep Screed <br />Installed As Per <br />Stampede or similar <br />2 <br />4 <br />&uk <br />DO NOT FLASH OVER <br />FRC R 03.7p21 <br />bottom <br />BOTTOM NAILING <br />g <br />5 <br />joint only <br />FLANGE <br />Maintain <br />Bottom of <br />Weep Screed <br />SELF -ADHERED FLASHING <br />WP04 <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />WP <br />FOUNDATION WEEP SCREED <br />WP09 <br />Weep Screed <br />2" Above Roof <br />Installed As Per <br />Manufact. Specs. & <br />HALF ROUND WINDOW <br />FRC R703.7.2.1 <br />Sheathing <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />Cement Plaster <br />butt joints need to <br />in accordance <br />becaulked using <br />with ASTMC926 <br />over wood 2nd <br />Stampede or sim. <br />floor <br />caulk for all <br />DOUBLE <br />JOIST <br />SINGLE <br />WOOD BEAM <br />JOIST <br />BELOW <br />.... <br />:�i.•ri4k:.-...... ': lna�n'vifi. , rmvmyyvi:i::•x:: <br />SELF -ADHERED <br />SELF -ADHERED <br />FLASHING <br />FLASHING O <br />Cement <br />SELF -ADHERED FLASHING <br />�/rr/PO� <br />DECK JOIST <br />V V <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. WEEP <br />SCREED DETAIL <br />NOT USED <br />NOT USED <br />NOT USED <br />SCALE: NOT TO SCALE <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p.813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineedng.com <br />CA 25948 <br />g <br />z UJ <br />a 0� <br />0 <br />�t;MC^ <br />Z aN <br />M <br />Z 00 <br />z� <br />W zCD <br />o <br />U <br />IZ <br />V) LU tTJ <br />LLJ <br />LU <br />LU� c~/> <br />v <br />� � J <br />I m <br />N LU <br />Q O co <br />Li ll- m <br />Z LU U O <br />Q Z Lo <br />Z <br />�O <br />CL <br />T) <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WRH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vosd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = i0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE R IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />19 LENNAR CORP.-THIS PLAN MAY NO <br />T OT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />2019-THES DRAWINGS AND N TH © E DESIGNS ARE E <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 1.02 ROOF UNDERLAYMENT REV. <br />02 11 19 1.03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSION NO. 1.03 / 02.11.19 <br />-3 <br />CV <br />� Ole O <br />Lw <br />m J <br />Z O <br />w <br />Q � = U <br />W c) <br />LO <br />a N = -LU UJI CV) <br />UJ 2� �* <br />Z Q ui = U-i LLi <br />V)C �� ad <br />LU ❑ ❑ <br />SHEET TITLE: <br />WATERPROOFING DETAILS <br />SHEET INFORMATION: <br />JOB NO.: 390446 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />W P <br />