OPTIONAL OVERHEAD 5ERVICE 5AME A5 -
<br />UNDERGROUND 150 OR 200 AMP 5ERVICE
<br />METER
<br />REFER TO FLOOR PLAN FOR
<br />NOTED AMP5. REQUIRED
<br />UNDERGROUND 5ERVICE
<br />BY POWER COMPANY
<br />14 GROUNDING WIRE WITH CODE
<br />APPROVED CLAMP PER 250.50
<br />AND 25052 OF THE 2014 NEC.
<br />150 = 01 COPPER OR 2/0 ALUMINUM
<br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT,
<br />TYPICAL A/C
<br />n[)15C. ELECTRICAL D15CONNECT PANEL 12 COPPER TO APPLIANCE5 AND GFI
<br />114 COPPER TO LIGHTS AND OUTLET5
<br />110 COPPER TO WATER HEATER
<br />18 COPPER TO RANGE
<br />#6 COPPER TO HVAC
<br />INTER5Y5TEM BONDING TERMINATION PER NEG 08, 250.94
<br />ELECTRICAL RISER DIAGRAM
<br />NOTE:
<br />ELECTRICAL MATERIAL5 AND IN5TALLATION5 SHALL COMPLY W/ APPLICABLE PROVI51ON5
<br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY
<br />5TAIR NOTES
<br />RAILING
<br />BALU5TER5 5NALL BE 5LACED 50 THAT A 4" 5PHERE CANNOT PA55 THROUGH.
<br />HANDRAILS
<br />HANDRAIL5 FOR 5TAIRWAY5 5NALL BE CONTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF
<br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWE5T R15ER. HANDRAIL END5 5NALL BE RETURNED OR 5NALL TERMINATE IN NEWEL P05T5 OR
<br />5AFETY TERMINAL5. HANDRAIL5 ADJACENT TO A WALL SHALL HAVE A 5PACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS,
<br />GONTINUOU5 GRA5PABLE HANDRAIL MJ5T MEET TYPE ONE OR TYPE TWO CRITERIA
<br />UNDER-5TAIR PROTECTION
<br />ENCL05ED ACCE551BLE 5PACE UNDER 5TAIR5 5NALL HAVE WALL5, UNDER-5TAIR 5URFACE AND ANY SOFFIT PROTECTED ON THE
<br />ENCLO5ED 51DE W/ 1/2 INCH GYP5UM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11
<br />5TAIRWALL FRAME NOTE
<br />ALL 5TAIRWELL 5URROUNDING WALLS AND KNEE WALL5 ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD
<br />CCGUPANCr AND CONSTRUCTION T''PE:
<br />TN15 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-B CLASSIFICATION,
<br />CEILING CONSTRUCTION:
<br />I. THE GARAGE 5NALL BE 5EPARATED FROM THE RE5IDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD APPLIED
<br />TO THE GARAGE 51DE. GARAGE5 BENEATH HABITABLE ROOM5 5NALL BE 5EPARATED FROM ALL HABITABLE ROOM5 ABOVE BY NOT LE55 THAN
<br />5/0 INCH (15.9 mm) TYPE "X" GYPSUM 50ARD OR EQUIVALENT, WHERE THE 5EPARATION 15 A FLOOR -CEILING A55EMBLY, THE STRUCTURE
<br />5UPPORTING THE 5EPARATION 5NALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD OR EQUIVALENT.
<br />DUELLING / GARAGE OPENING5:
<br />1. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOOR5 NOT LE55 THAN 13/0" IN THICKNE55,
<br />SOLID CORE (5.C.) OR HONEYCOMB CORE 5TEEL DOOR5 NOT LE55 THAN 1 3/8" THICK, OR 20 MINUTE FIRE RATED DOOR5.
<br />2. ALL DOOR5 FROM GARAGE ADJACENT TO LIVING 5PACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTE5,
<br />EGRE55:
<br />EACH BEDROOM MU5T HAVE ONE WINDOW THAT COMPLIE5 WITH EGRE55 CODE5, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE
<br />WINDOW MU5T HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15P FLOOR LINE OF THAT PARTICULAR ROOM.
<br />WINDOW INSTALLATION:
<br />WINDOW5 5NALL BE IN5TALLED AND FLA5HED IN ACCORDANCE WITH THE MANUFACTURER5 WRITTEN IN5TALLATION IN5TRUCTION5, WRITTEN
<br />IN5TALLATION IN5TRUCTION5 5NALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.
<br />TERMITE PROTECTION:
<br />I. PENETRATION. PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LAB-ON-GRADE FLOOR5 5NALL NOT BE OF GELLUL05E
<br />CONTAINING MATERIAL5. IF 501L TREATMENT 15 U5ED FOR 5U5TERRANEAN TERMITE PROTECTION, THE 5LEEVE 5NALL HAVE A MAXIMUM WALL
<br />THICKNE55 OF 0.010 INCH, AND BE 5EALED WITHIN THE 5LA5 U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PACE
<br />BETWEEN THE PIPE AND THE 5LEEVE. NO TERMITICIDE5 5NALL BE APPLIED IN51DE THE 5LEEVE.
<br />2. PROTECTION AGAIN5T DECAY AND TERMITE5. - CONDEN5ATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR 5PRAY HEAD5, AND ROOF
<br />DOWN5POUT5 5NALL D15CHARGE AT LEA5T I FOOT (305 mm) AWAY FROM THE 5TRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL
<br />EXTEN51ON5, OR 5PLA51-1 BLOCK5, GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDING5 WITH EAVE5 OF LE55 THAN 6 INCHE5 (152 mm)
<br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKE5 OR ON A ROOF ABOVE ANOTHER ROOF,
<br />I
<br />TOP RAILING
<br />NOTE: 5UBFLOOR ADHE51VE 15 U5ED IN ADDITION
<br />BALUSTERS TO NAILS ON WOOD COMPONENT5.
<br />MAX 5PACING 4"
<br />1 X 0 PAINTED WD. CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO
<br />OGEE 5TOP THE 51ZE OF A 2 X 12 5.Y.P, AND 15 NAILED TO EACH
<br />TREAD W/ 16d NAIL5 FROM THIRD LAMINATE TO TREAD—
<br />OPT, 2 X 2 BLOCKING NAILED /
<br />TO TREAD AND R15ER.
<br />3-2 X 12 5TRINGER 2 X BLOCKING NAILED TO 5TRINGER, Z 1
<br />3/4" R15ER5 R15ER, AND TREAD. +
<br />2 X TREADS± RIP FROM 2x12 I X 5PRUCE #3 OR 3/4" CDX. + +
<br />TO 51ZE NOTED ON PLAN PLYWD, RISER +
<br />2 X 5OUTHERN YELLOW PINE #1
<br />(ACTUAL THICKNE55 15 1 1/2") TREAD,
<br />TYP. OPT. RAILING ELEVATION
<br />5CALE: 1/2" : I'-0"
<br />NEWEL P05T
<br />TOP RAILING
<br />BALU5TER 4" D.C.
<br />SHOE RAIL (REMOVE
<br />W/ METAL 5PINDLE5)
<br />I X 8 PAINTED WE). CAP
<br />OGEE 5TOP
<br />rwuK LINt
<br />OPTIONAL
<br />A RAILING DETAIL
<br />5CALE. I I 0
<br />CLOSED RISER DETAIL
<br />CARPf
<br />CARPf
<br />TREAC
<br />R15ER
<br />SCALE: 1/2" = 1'-0"
<br />2 X 4 WALL
<br />1/2" GYP BD,
<br />3/4" SKIRT BD,
<br />2 X 4 SPACER
<br />2X12
<br />5TRINGER
<br />TYPICAL STAIR
<br />FRAMING DETAIL
<br />B SCALE: 3/4" : 1'-0"
<br />GENERAL CONSTRUCTION NOTES
<br />CHAPTER5 AND 5ECTION5 REFER TO F.B.C. RE5IDENTIAL 6th EDITION (2011)
<br />MECHANICAL AND NYAC
<br />I. ENERGY CALCULATION5 FOR HEATING AND COOLING CAPAGITIE5 5NALL BE FURN15HED BY THE GENERAL CONTRACTOR 45 AN ATTACHMENT TO
<br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT.
<br />2. MECHANICAL APPLIANCES 5NALL BE ACCE551BLE FOR I1\15PECTION, 5ERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT
<br />CON5TRUCTION, OTHER APPLIANCE5, OR ANY OTHER PIPING OR DUCT5 NOT CONNECTED TO THE APPLIANCE BEING I1\15PECTED, 5ERVICED,
<br />REPAIRED, OR REPLACED. A LEVEL WORKING 5PACE AT LEA5T 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE 5NALL BE PROVIDED IN
<br />FRONT OF THE CONTROL 51DE TO 5ERVICE AN APPLIANCE.
<br />3. DUCT5 IN THE GARAGE AND DUCT5 PENETRATING THE WALL5 OR CEILING5 5EPARATING THE DWELLING FROM THE GARAGE 5NALL BE
<br />CON5TRUCTED OF A MIN.126 GAUGE (0.48 mm) 5HEET 5TEEL OR OTHER APPROVED MATERIAL AND 5NALL HAVE NO OPENING5 INTO THE GARAGE,
<br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 5NALL BE RAI5ED AT LEA5T 3 INCHE5 (16 mm) ABOVE THE FINISHED
<br />GRADE AND 5NALL AL50 CONFORM TO THE MANUFACTURER'5 IN5TALLATION IN5TRUCTION5.
<br />5. AUXILIARY DRAIN PAN, CATEGORY IV CONDEN51NG APPLIANCE5 SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO
<br />ANY BUILDING COMPONENT WILL OCCUR A5 A RE5ULT OF 5TOPPAGE IN THE CONDEN54TE DRAIN PIPING 5Y5TEM. THE5E PANS 5NALL BE
<br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV1510N5 OF 5ECTION5 M1411.3,
<br />EXHAUST FAN5 AND VENTING:
<br />(.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST 5Y5TEM 5NALL BE D15CHARGED TO THE OUTDOOR5. AIR 5NALL
<br />NOT BE EXHAU5TED INTO AN ATTIC, 5OFFIT, RIDGE VENT OR CRAWL 5PACE.
<br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOM5 5NALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND
<br />5NALL BE EXHAU5TED DIRECTLY TO THE OUTDOOR5. EXHAU5T AIR FROM BATHROOM5 AND TOILET ROOM5 5NALL NOT D15CHARGE INTO AN ATTIC,
<br />CRAWL SPACE, OR OTHER AREA5 IN51DE THE BUILDING.
<br />3, DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHE5 DRYER EXHAUST DUCT 5NALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE
<br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT 5NALL BE REDUCED 25 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND
<br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOE5 NOT INCLUDE THE TRANSITION
<br />DUCT.
<br />EXCEPTION - WHERE A CLOTHE5 DRYER 5005TER FAN 15 IN5TALLED AND 115TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF
<br />THE EXHAU5T DUCT, INCLUDING ANY TRAN51TION DUCT, 5NALL BE PERMITTED TO BE IN ACCORDANCE WITH THE B005TER FAN MANUFACTURER15
<br />INSTALLATION IN5TRUCTION5. WHERE A CLOTHE5 DRYER B005TER FAN 15 IN5TALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN WHICH
<br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL 5NALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTER5 THE WALL. THE
<br />LABEL 514ALL BEAR THE WORD5 "THIS DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED B005TER FAN."
<br />4. PROVIDE LOUVER DEvIGE5 AT INTAKE AND EXHAU5T LOCATION5 IN ACCORDANCE WITH
<br />AMGA 5TANDARD 550 IN FBC.
<br />ROU6N=IN IN5PECTION REQUEST NOTE
<br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MU5T BE
<br />COMPLETE, IN5PECTED AND APPROVED BEFORE REQUE5TING THE
<br />FRAMING IN5PECTION,
<br />WINDOW FALL PROTECTION
<br />IN DWELLING UNIT5, WHERE THE OPENING OF AN OPERABLE WINDOW 15
<br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FIN15HED GRADE OR
<br />5URFACE BELOW, THE LOWE5T PART OF THE CLEAR OPENING OF THE
<br />WINDOW 5NALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FIN15HED
<br />FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE
<br />5ECTION5 OF WINDOW5 5NALL NOT PERMIT OPENING5 THAT ALLOW
<br />PA55AGE OF A 4 INCH DIAMETER 5PHERE WHERE 5UCH OPENING5
<br />ARE LOCATED WITHIN 24 INCHE5 OF THE FIN15HED FLOOR PER RRC,
<br />RE51DENTIAL 6th EDITION (2011) - 5ECTION R312.2.
<br />WINDOW FALL PREVENTION DEVICE5 AND WINDOW GUARD5, WHERE
<br />PROVIDED, 5NALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090
<br />PER F.B.C. RE5IDENTIAL 6th EDITION (2011) - 5ECTION R3122.
<br />IN5ULATION NOTE5
<br />• CMU WALLS:----- R-FOIL 4.1 KNEE WALL5 THAT
<br />BACK UP TO CEILING
<br />• FRAME WALLS:-------- R-13 AREA ONLY:----------- R-19
<br />• CEILING:------------- R-30
<br />ON51TE FOUNDATION 5URI/E'' NOTE
<br />A FOUNDATION 5URVEY 5NALL BE PERFORMED AND A COPY OF THE
<br />5URVEY 5NALL BE ON THE 511E FOR THE BUILDING IN5PECTOR'5 U5E,
<br />OR ALL PROPERTY MARKER5 5NALL BE EXP05ED AND A 5TRING
<br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED
<br />5ETBACK5.
<br />CELING AT ENTRY' NOTE
<br />ALL ENTRY CLG5. TO BE 15/32 056. CEMENTITOU5 FINISH (U.N.0)
<br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE
<br />PROTECTION OF GA5 APPLIANCE5 IN RE51DENTIAL GARAGE5:
<br />MINIMUM 3" DIAMETER 5CH 40 STEEL PIPE, 2 FT. BELOW CONCRETE
<br />5LAB AND 3 FT. ABOVE FINISHED FLOOR,
<br />GENERAL NOTES
<br />• DUE TO VARIATION5 IN CITY REQUIREMENT5, 5U5DIVI510N
<br />5PECIFICATION5, CON5TRUCTION TECHNIQUES, DIVER51TY IN
<br />MATERIAL5, AND PLAN REV1510N5, ALL DIMEN51ON5 AND
<br />ELEvATION5 MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD
<br />CONDITION5 MAY VARY AND MU5T BE VERIFIED BEFORE
<br />PROCEEDING WITH CON5TRUCTION.
<br />• ELECTRICAL LOCATION5 5HOWN ON DRAWING5 MAY BE CHANGED
<br />AT THE 50LE D15GRETION OF CALATLANTIC HOME5 OR IT5
<br />LICEN5ED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND
<br />MUNICIPAL BUILDING AND ELECTRICAL CODE5, CALATLANTIC
<br />HOME5 WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLET5
<br />AND / OR 5WITCHE5 5HOWN.
<br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER
<br />LINE OF THE FIXTURE TO THE EXTERIOR 5LAB EDGE. IT 15 THE
<br />RE5PON51BILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF
<br />ALL PLUMBING DIMEN51ON5.
<br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWING5 REFERENCING
<br />LUMBER 51ZE5 OR WALL THICKNESSES ARE TO BE CONSIDERED "NOMINAL DIMEN51ON5"
<br />CHIMNE'' HEIGHT REQUIREMENTS:
<br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE IN5T4LLED THE CHIMNEY MU5T EXTEND 3'-0" PA5T THE HIGHER POINT WHERE IT
<br />EXTEND5 THROUGH THE ROOF AND MU5T BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'-0" AWAY OR CLO5ER.
<br />TUE3 AND SHOWER AREAS:
<br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYP5UM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM C1288, C1325, OR CI118
<br />AND IN5TALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION5 5NALL BE U5ED A5 BACKERS FOR WALL TILE IN TUB AND
<br />5HOWER AREA5, AND WALL PANEL5 IN SHOWER AREA5.
<br />FLOOD ZONE REQUIREMENTS:
<br />PLAN MEET5 OR EXCEED5 FEMA FLOOD FIN15HED GARAGE FLOOR ELEVATION.
<br />BEWS
<br />DESIGN GROUP
<br />150 STATE STREET EAST
<br />OLDSMAR, FLORIDA 346T7
<br />813. 925 .1300 TEL
<br />813 . 92S . 1800 FAX
<br />W W W.DAVISBEWS.COM
<br />TAMPA • DIIWER
<br />�--�-a FST. 1994 ���
<br />0
<br />zC)
<br />N
<br />O : O
<br />> to M o
<br />0
<br />� a
<br />Q aL
<br />M
<br />Q V c �
<br />z�'F-
<br />wWo
<br />J �
<br />�o
<br />0z
<br />�°
<br />�o
<br />z d
<br />z�
<br />r F.
<br />Lu
<br />0Qgo
<br />J
<br />o w Z
<br />Q �ao
<br />a c cu-
<br />UU Lu c-
<br />W �Wo
<br />o�
<br />Q zz
<br />}o
<br />�w
<br />z z g
<br />0 ��
<br />o U oQ
<br />z
<br />p� w
<br />L
<br />i �
<br />z Q�W
<br />z 0
<br />z
<br />Lu
<br />z o�
<br />w z I— (D
<br />57 0
<br />z Q ui
<br />m z
<br />° g W m
<br />SCALE : AS NOTED
<br />DATE : 10-19-2018
<br />VERSION NO.
<br />ino
<br />SHEET NO.
<br />DT1
<br />4f-
<br />DAVIS
<br />
|