Laserfiche WebLink
OPTIONAL OVERHEAD 5ERVICE 5AME A5 - <br />UNDERGROUND 150 OR 200 AMP 5ERVICE <br />METER <br />REFER TO FLOOR PLAN FOR <br />NOTED AMP5. REQUIRED <br />UNDERGROUND 5ERVICE <br />BY POWER COMPANY <br />14 GROUNDING WIRE WITH CODE <br />APPROVED CLAMP PER 250.50 <br />AND 25052 OF THE 2014 NEC. <br />150 = 01 COPPER OR 2/0 ALUMINUM <br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT, <br />TYPICAL A/C <br />n[)15C. ELECTRICAL D15CONNECT PANEL 12 COPPER TO APPLIANCE5 AND GFI <br />114 COPPER TO LIGHTS AND OUTLET5 <br />110 COPPER TO WATER HEATER <br />18 COPPER TO RANGE <br />#6 COPPER TO HVAC <br />INTER5Y5TEM BONDING TERMINATION PER NEG 08, 250.94 <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIAL5 AND IN5TALLATION5 SHALL COMPLY W/ APPLICABLE PROVI51ON5 <br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />5TAIR NOTES <br />RAILING <br />BALU5TER5 5NALL BE 5LACED 50 THAT A 4" 5PHERE CANNOT PA55 THROUGH. <br />HANDRAILS <br />HANDRAIL5 FOR 5TAIRWAY5 5NALL BE CONTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWE5T R15ER. HANDRAIL END5 5NALL BE RETURNED OR 5NALL TERMINATE IN NEWEL P05T5 OR <br />5AFETY TERMINAL5. HANDRAIL5 ADJACENT TO A WALL SHALL HAVE A 5PACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS, <br />GONTINUOU5 GRA5PABLE HANDRAIL MJ5T MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER-5TAIR PROTECTION <br />ENCL05ED ACCE551BLE 5PACE UNDER 5TAIR5 5NALL HAVE WALL5, UNDER-5TAIR 5URFACE AND ANY SOFFIT PROTECTED ON THE <br />ENCLO5ED 51DE W/ 1/2 INCH GYP5UM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11 <br />5TAIRWALL FRAME NOTE <br />ALL 5TAIRWELL 5URROUNDING WALLS AND KNEE WALL5 ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD <br />CCGUPANCr AND CONSTRUCTION T''PE: <br />TN15 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-B CLASSIFICATION, <br />CEILING CONSTRUCTION: <br />I. THE GARAGE 5NALL BE 5EPARATED FROM THE RE5IDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD APPLIED <br />TO THE GARAGE 51DE. GARAGE5 BENEATH HABITABLE ROOM5 5NALL BE 5EPARATED FROM ALL HABITABLE ROOM5 ABOVE BY NOT LE55 THAN <br />5/0 INCH (15.9 mm) TYPE "X" GYPSUM 50ARD OR EQUIVALENT, WHERE THE 5EPARATION 15 A FLOOR -CEILING A55EMBLY, THE STRUCTURE <br />5UPPORTING THE 5EPARATION 5NALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD OR EQUIVALENT. <br />DUELLING / GARAGE OPENING5: <br />1. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOOR5 NOT LE55 THAN 13/0" IN THICKNE55, <br />SOLID CORE (5.C.) OR HONEYCOMB CORE 5TEEL DOOR5 NOT LE55 THAN 1 3/8" THICK, OR 20 MINUTE FIRE RATED DOOR5. <br />2. ALL DOOR5 FROM GARAGE ADJACENT TO LIVING 5PACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTE5, <br />EGRE55: <br />EACH BEDROOM MU5T HAVE ONE WINDOW THAT COMPLIE5 WITH EGRE55 CODE5, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE <br />WINDOW MU5T HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15P FLOOR LINE OF THAT PARTICULAR ROOM. <br />WINDOW INSTALLATION: <br />WINDOW5 5NALL BE IN5TALLED AND FLA5HED IN ACCORDANCE WITH THE MANUFACTURER5 WRITTEN IN5TALLATION IN5TRUCTION5, WRITTEN <br />IN5TALLATION IN5TRUCTION5 5NALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />TERMITE PROTECTION: <br />I. PENETRATION. PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LAB-ON-GRADE FLOOR5 5NALL NOT BE OF GELLUL05E <br />CONTAINING MATERIAL5. IF 501L TREATMENT 15 U5ED FOR 5U5TERRANEAN TERMITE PROTECTION, THE 5LEEVE 5NALL HAVE A MAXIMUM WALL <br />THICKNE55 OF 0.010 INCH, AND BE 5EALED WITHIN THE 5LA5 U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PACE <br />BETWEEN THE PIPE AND THE 5LEEVE. NO TERMITICIDE5 5NALL BE APPLIED IN51DE THE 5LEEVE. <br />2. PROTECTION AGAIN5T DECAY AND TERMITE5. - CONDEN5ATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR 5PRAY HEAD5, AND ROOF <br />DOWN5POUT5 5NALL D15CHARGE AT LEA5T I FOOT (305 mm) AWAY FROM THE 5TRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTEN51ON5, OR 5PLA51-1 BLOCK5, GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDING5 WITH EAVE5 OF LE55 THAN 6 INCHE5 (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKE5 OR ON A ROOF ABOVE ANOTHER ROOF, <br />I <br />TOP RAILING <br />NOTE: 5UBFLOOR ADHE51VE 15 U5ED IN ADDITION <br />BALUSTERS TO NAILS ON WOOD COMPONENT5. <br />MAX 5PACING 4" <br />1 X 0 PAINTED WD. CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO <br />OGEE 5TOP THE 51ZE OF A 2 X 12 5.Y.P, AND 15 NAILED TO EACH <br />TREAD W/ 16d NAIL5 FROM THIRD LAMINATE TO TREAD— <br />OPT, 2 X 2 BLOCKING NAILED / <br />TO TREAD AND R15ER. <br />3-2 X 12 5TRINGER 2 X BLOCKING NAILED TO 5TRINGER, Z 1 <br />3/4" R15ER5 R15ER, AND TREAD. + <br />2 X TREADS± RIP FROM 2x12 I X 5PRUCE #3 OR 3/4" CDX. + + <br />TO 51ZE NOTED ON PLAN PLYWD, RISER + <br />2 X 5OUTHERN YELLOW PINE #1 <br />(ACTUAL THICKNE55 15 1 1/2") TREAD, <br />TYP. OPT. RAILING ELEVATION <br />5CALE: 1/2" : I'-0" <br />NEWEL P05T <br />TOP RAILING <br />BALU5TER 4" D.C. <br />SHOE RAIL (REMOVE <br />W/ METAL 5PINDLE5) <br />I X 8 PAINTED WE). CAP <br />OGEE 5TOP <br />rwuK LINt <br />OPTIONAL <br />A RAILING DETAIL <br />5CALE. I I 0 <br />CLOSED RISER DETAIL <br />CARPf <br />CARPf <br />TREAC <br />R15ER <br />SCALE: 1/2" = 1'-0" <br />2 X 4 WALL <br />1/2" GYP BD, <br />3/4" SKIRT BD, <br />2 X 4 SPACER <br />2X12 <br />5TRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B SCALE: 3/4" : 1'-0" <br />GENERAL CONSTRUCTION NOTES <br />CHAPTER5 AND 5ECTION5 REFER TO F.B.C. RE5IDENTIAL 6th EDITION (2011) <br />MECHANICAL AND NYAC <br />I. ENERGY CALCULATION5 FOR HEATING AND COOLING CAPAGITIE5 5NALL BE FURN15HED BY THE GENERAL CONTRACTOR 45 AN ATTACHMENT TO <br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCES 5NALL BE ACCE551BLE FOR I1\15PECTION, 5ERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CON5TRUCTION, OTHER APPLIANCE5, OR ANY OTHER PIPING OR DUCT5 NOT CONNECTED TO THE APPLIANCE BEING I1\15PECTED, 5ERVICED, <br />REPAIRED, OR REPLACED. A LEVEL WORKING 5PACE AT LEA5T 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE 5NALL BE PROVIDED IN <br />FRONT OF THE CONTROL 51DE TO 5ERVICE AN APPLIANCE. <br />3. DUCT5 IN THE GARAGE AND DUCT5 PENETRATING THE WALL5 OR CEILING5 5EPARATING THE DWELLING FROM THE GARAGE 5NALL BE <br />CON5TRUCTED OF A MIN.126 GAUGE (0.48 mm) 5HEET 5TEEL OR OTHER APPROVED MATERIAL AND 5NALL HAVE NO OPENING5 INTO THE GARAGE, <br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 5NALL BE RAI5ED AT LEA5T 3 INCHE5 (16 mm) ABOVE THE FINISHED <br />GRADE AND 5NALL AL50 CONFORM TO THE MANUFACTURER'5 IN5TALLATION IN5TRUCTION5. <br />5. AUXILIARY DRAIN PAN, CATEGORY IV CONDEN51NG APPLIANCE5 SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR A5 A RE5ULT OF 5TOPPAGE IN THE CONDEN54TE DRAIN PIPING 5Y5TEM. THE5E PANS 5NALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV1510N5 OF 5ECTION5 M1411.3, <br />EXHAUST FAN5 AND VENTING: <br />(.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST 5Y5TEM 5NALL BE D15CHARGED TO THE OUTDOOR5. AIR 5NALL <br />NOT BE EXHAU5TED INTO AN ATTIC, 5OFFIT, RIDGE VENT OR CRAWL 5PACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOM5 5NALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND <br />5NALL BE EXHAU5TED DIRECTLY TO THE OUTDOOR5. EXHAU5T AIR FROM BATHROOM5 AND TOILET ROOM5 5NALL NOT D15CHARGE INTO AN ATTIC, <br />CRAWL SPACE, OR OTHER AREA5 IN51DE THE BUILDING. <br />3, DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHE5 DRYER EXHAUST DUCT 5NALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT 5NALL BE REDUCED 25 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND <br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOE5 NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A CLOTHE5 DRYER 5005TER FAN 15 IN5TALLED AND 1­15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAU5T DUCT, INCLUDING ANY TRAN51TION DUCT, 5NALL BE PERMITTED TO BE IN ACCORDANCE WITH THE B005TER FAN MANUFACTURER15 <br />INSTALLATION IN5TRUCTION5. WHERE A CLOTHE5 DRYER B005TER FAN 15 IN5TALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL 5NALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTER5 THE WALL. THE <br />LABEL 514ALL BEAR THE WORD5 "THIS DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED B005TER FAN." <br />4. PROVIDE LOUVER DEvIGE5 AT INTAKE AND EXHAU5T LOCATION5 IN ACCORDANCE WITH <br />AMGA 5TANDARD 550 IN FBC. <br />ROU6N=IN IN5PECTION REQUEST NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MU5T BE <br />COMPLETE, IN5PECTED AND APPROVED BEFORE REQUE5TING THE <br />FRAMING IN5PECTION, <br />WINDOW FALL PROTECTION <br />IN DWELLING UNIT5, WHERE THE OPENING OF AN OPERABLE WINDOW 15 <br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FIN15HED GRADE OR <br />5URFACE BELOW, THE LOWE5T PART OF THE CLEAR OPENING OF THE <br />WINDOW 5NALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FIN15HED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE <br />5ECTION5 OF WINDOW5 5NALL NOT PERMIT OPENING5 THAT ALLOW <br />PA55AGE OF A 4 INCH DIAMETER 5PHERE WHERE 5UCH OPENING5 <br />ARE LOCATED WITHIN 24 INCHE5 OF THE FIN15HED FLOOR PER RRC, <br />RE51DENTIAL 6th EDITION (2011) - 5ECTION R312.2. <br />WINDOW FALL PREVENTION DEVICE5 AND WINDOW GUARD5, WHERE <br />PROVIDED, 5NALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 <br />PER F.B.C. RE5IDENTIAL 6th EDITION (2011) - 5ECTION R3122. <br />IN5ULATION NOTE5 <br />• CMU WALLS:----- R-FOIL 4.1 KNEE WALL5 THAT <br />BACK UP TO CEILING <br />• FRAME WALLS:-------- R-13 AREA ONLY:----------- R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URI/E'' NOTE <br />A FOUNDATION 5URVEY 5NALL BE PERFORMED AND A COPY OF THE <br />5URVEY 5NALL BE ON THE 511E FOR THE BUILDING IN5PECTOR'5 U5E, <br />OR ALL PROPERTY MARKER5 5NALL BE EXP05ED AND A 5TRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />5ETBACK5. <br />CELING AT ENTRY' NOTE <br />ALL ENTRY CLG5. TO BE 15/32 056. CEMENTITOU5 FINISH (U.N.0) <br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE <br />PROTECTION OF GA5 APPLIANCE5 IN RE51DENTIAL GARAGE5: <br />MINIMUM 3" DIAMETER 5CH 40 STEEL PIPE, 2 FT. BELOW CONCRETE <br />5LAB AND 3 FT. ABOVE FINISHED FLOOR, <br />GENERAL NOTES <br />• DUE TO VARIATION5 IN CITY REQUIREMENT5, 5U5DIVI510N <br />5PECIFICATION5, CON5TRUCTION TECHNIQUES, DIVER51TY IN <br />MATERIAL5, AND PLAN REV1510N5, ALL DIMEN51ON5 AND <br />ELEvATION5 MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD <br />CONDITION5 MAY VARY AND MU5T BE VERIFIED BEFORE <br />PROCEEDING WITH CON5TRUCTION. <br />• ELECTRICAL LOCATION5 5HOWN ON DRAWING5 MAY BE CHANGED <br />AT THE 50LE D15GRETION OF CALATLANTIC HOME5 OR IT5 <br />LICEN5ED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODE5, CALATLANTIC <br />HOME5 WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLET5 <br />AND / OR 5WITCHE5 5HOWN. <br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR 5LAB EDGE. IT 15 THE <br />RE5PON51BILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMEN51ON5. <br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWING5 REFERENCING <br />LUMBER 51ZE5 OR WALL THICKNESSES ARE TO BE CONSIDERED "NOMINAL DIMEN51ON5" <br />CHIMNE'' HEIGHT REQUIREMENTS: <br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE IN5T4LLED THE CHIMNEY MU5T EXTEND 3'-0" PA5T THE HIGHER POINT WHERE IT <br />EXTEND5 THROUGH THE ROOF AND MU5T BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'-0" AWAY OR CLO5ER. <br />TUE3 AND SHOWER AREAS: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYP5UM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM C1288, C1325, OR CI118 <br />AND IN5TALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION5 5NALL BE U5ED A5 BACKERS FOR WALL TILE IN TUB AND <br />5HOWER AREA5, AND WALL PANEL5 IN SHOWER AREA5. <br />FLOOD ZONE REQUIREMENTS: <br />PLAN MEET5 OR EXCEED5 FEMA FLOOD FIN15HED GARAGE FLOOR ELEVATION. <br />BEWS <br />DESIGN GROUP <br />150 STATE STREET EAST <br />OLDSMAR, FLORIDA 346T7 <br />813. 925 .1300 TEL <br />813 . 92S . 1800 FAX <br />W W W.DAVISBEWS.COM <br />TAMPA • DIIWER <br />�--�-a FST. 1994 ��� <br />0 <br />zC) <br />N <br />O : O <br />> to M o <br />0 <br />� a <br />Q aL <br />M <br />Q V c � <br />z�'F- <br />wWo <br />J � <br />�o <br />0z <br />�° <br />�o <br />z d <br />z� <br />r F. <br />Lu <br />0Qgo <br />J <br />o w Z <br />Q �ao <br />a c cu- <br />UU Lu c- <br />W �Wo <br />o� <br />Q zz <br />}o <br />�w <br />z z g <br />0 �� <br />o U oQ <br />z <br />p� w <br />L <br />i � <br />z Q�W <br />z 0 <br />z <br />Lu <br />z o� <br />w z I— (D <br />57 0 <br />z Q ui <br />m z <br />° g W m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />ino <br />SHEET NO. <br />DT1 <br />4f- <br />DAVIS <br />