My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6404 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6404 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:14:04 PM
Creation date
2/19/2025 2:05:58 PM
Metadata
Fields
Template:
Building Plans
Street #
6404
Location
Cobble Bliss St
Contractor
Lennar Homes
Building Plans - Permit #
21539
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EJ <br />EJ <br />EJ <br />E <br />E <br />('') L0 <br />VS U U U <br />SPECIFICATION FOR LEDGER5 <br />(THE FOLLOWING 5HALL APPLY UN.0) <br />LEDGER A (LA) - � SYP. 2x4 PT W/ 1/4" DIA. x 3" TAPCON5 AT 12" O.C. 5ET AT 5HEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP. UNO AT LOUDER ROOF TO UPPER WALL AT PARALLEL TRU55E5). <br />NOTE: THI5 15 A REQUIRED TERMINATION FOR THE 5HEATHING DIAPHRAGM, AND PROVIDE5 LATERAL DIAPHRAGM 5UPPORT TO THE MA50NRY WALL. A TRU55 515TERED TO THE <br />WALL 15 NOT AN ACCEPTABLE 5U55TITUTE, UNLE55 THAT TRU6515 ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). <br />LEDGER B (LB) - #2 5YP. 2x4 W/ (3) 0,131" x 3-1/2" R5. NAIL5 AT EA. 5TUD (1(o" O.C. MAX.) 5ET AT 5HEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP, UNO). NOTE: THI5 15 A REQUIRED TERMINATION FOR <br />THE 5HEATHING DIAPHRAGM, AND PROVIDES LATERAL DIAPHRAGM 5UPPORT TO THE FRAME WALL, A TRUSS 515TERED TO THE WALL 15 NOT AN ACCEPTABLE SUBSTITUTE, UNLE55 <br />THAT TRU5515 ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). <br />LEDGER C (LC) - � 5YP, (2) 28 PT W/ 5/8" DIA. x 6" A.B. AT 12" O.C. 5TAG6ERED W/ 5IMP50N HU/HUC28 AT FACE ATTACHMENT OR HT516 AT TOP CHORD BEARING AT EA. TRU55 (TYP. UNO), <br />ALTERNATE EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE. <br />LEDGER D (LD) -12 SYP. (2) 2x8 PT W/ (4) 5IMP50N 5D525600 5CREW5 AT EA. STUD (16" O.G. MAX.) W/ 5IMP50N HU/HUC228 AT FACE ATTACHMENT OR HT5WI6 AT TOP CHORD BEARING AT EA. TRU55 (TYP. UNO). <br />ALTERNATE EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE. <br />LEDGER E (LE) - 02 5YP. (2) 2x12 PT W/ 5/8" DIA. x 8" A.B. AT 12" O.C. 5TAGGERED W/ RT4 MIN, OR EQUAL AT TOP CHORD BEARING OR EQUAL AT FACE BEARING AT EA. TRU55 (TYP. UNO AT PERPENDICULAR <br />FLOOR TRU55 5UPPORT ALONG MA50NRY WALL). <br />LEDGER F (LF) - � 5YP. 2x8 PT W/ 5/8" DIA. x 8" A.B. AT 24" O.C. STAGGERED 5ET AT 5HEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP. UNO AT FLOOR 5HEATHING 5UPPORT AT MA50NRY AT <br />PARALLEL FLOOR TRU55E5). NOTE: TH1515 A REQUIRED TEIMINATION FOR THE FLOOR DIAPHRAGM, AND PROVIDE5 LATERAL DIAPHRAGM 5UPPORT TO THE MA50NRY WALL. A <br />TRU55 515TERED TO THE WALL 15 NOT AN ACCEPTABLE 5U55TITUTE, UNLE55 THAT TRU55 15 ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). <br />LEDGER G (LG) -12 5YP. (U 2x8 W/ (4) 5IMP50N 5D525412 5CREW5 AT EA, 5TUD (16" O.G. MAXJ W/ 6IMP50N HU/HUC28 AT FACE ATTACHMENT OR HT% AT TOP CHORD BEARING AT EA. TRU55 (TYP. UNO). <br />ALTERNATE EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE. <br />LEDGER H (LC) - 12 5YP. (2) 2X8 PT W/ 1/2" DIA. X 6" TITAN5 AT 16" O.C. STAGGERED W/ 5IMP50N HU/HUC28 AT FACE ATTACHMENT OR HT516 AT TOP CHORD BEARING AT EA. TRU55 (TYP. UNO). <br />ALTERNATE EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE. <br />LEDGER I (LI) -' SYP. 2X4 PT W/ 1/4" DIA. X 3" TAPCON5 AT 6" 5TAGGERED W/ (1) 5IMP50N LU524 AT FACE ATTACHMENT AT EACH TRU55 BOTTOM CHORD AND (U 5IMP50N H3 AT TOP CHORD ORIENTED <br />HORIZONTALLY. ALT. EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE, AT TOP AND BOTTOM LEDGER, NAIL 5HEATHING TO LEDGER W/ TYPICAL EDGE NAILING PATTERN. <br />LEDGER J (LJ) - � 5YP. 2x4 PT W/ 1/4" DIA. X 3" TAPCON5 AT 4" O.C. 5TAGGERED W/ (U 51MP60N LU524 AT FACE ATTACHMENT AT EACH TRU55 BOTTOM CHORD AND (1) 5IMP50N H3 AT TOP CHORD ORIENTED <br />HORIZONTALLY. ALTERNATE EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE. AT TOP AND BOTTOM LEDGER, NAIL 5HEATHING TO LEDGER W/ 0.131" DIA R5. NAIL5 AT 3" O.C. <br />LEDGER M (LM) - � 5YP. 2X4 W/ (3) 5IMP50N 5D525600 5CREW5 AT EA. 5TUD (16" O.C. MAX.) W/ (U 5IMP50N LU524 AT FACE ATTACHMENT AT EACH TRU55 BOTTOM CHORD AND (U 5IMP50N H3 AT TOP CHORD <br />ORIENTED HORIZONTALLY. ALT. EQUAL OR BETTER CONNECTOR5 ARE ACCEPTABLE, AT TOP AND BOTTOM LEDGER, NAIL 5HEATHING TO LEDGER W/ TYPICAL EDGE NAILING PATTERN, <br />NOTE: AT LEDGER5 C D OR H, 5IMP50N HU/HUC28-2 OR HU/HUC28-3 MAY BE U5ED FOR 2 PLY OR 3 PLY HANGERED TRU55 ATTACHMENT RESPECTIVELY URO, <br />o(o 1118 <br />>o > > > > > > <br />- 0" Co I\ <br />H- <br />E- <br />c>il > > > > c>u r>) (LO � r- ago m <br />L7 <br />> <br />> <br />- <br />E_ <br />LD <br />;J1 <br />CJ1 <br />;J3 <br />GJ <br />;J5 <br />CJ`_ <br />_J7 <br />EJ-/ <br />_J7 <br />EJ/ <br />_J7 <br />EJi <br />_J7 <br />Q <br />EJi <br />_J7 <br />M <br />0Cw_ <br />� <br />LLJ <br />LL <br />0 <br />EJi <br />_J7 <br />7VC <br />7VB <br />7VA <br />~ <br />Q <br />J <br />W <br />Q <br />W <br />� <br />�- <br />Q <br />Q <br />� <br />E:] <br />z <br />� <br />W <br />Q <br />l� <br />v <br />EJi <br />EJi <br />EJ-/ <br />EJ/ <br />w <br />LD <br />> <br />3/12 <br />VAULT A <br />J7V <br />aj <br />M Q <br />EJi <br />EJ i <br />J <br />(\1 <br />EJ7VD <br />EJ <br />A <br />¢ <br />) <br />EJ7VE <br />l� <br />EJ7VF <br />X <br />x2 <br />L; <br />J <br />CJ <br />EJ7VG <br />-_J7w <br />-__J7W <br />V J <br />LD Q <br />Z W <br />0-X <br />> <br />�-Li <br />a <br />W Q <br />_J7 <br />x2 <br />7J7 <br />�I'- <br />W C] <br />Z <br />J7 <br />Q <br />W <br />CL <br />W <br />E: <br />ry <br />� � <br />W <br />= <br />W <br />:J5 <br />'J3 <br />J1 <br />11 <br />If <br />11 <br />If <br />11 <br />11 <br />11 <br />9= <br />w <br />1. 1119' <br />NN <br />pa <br />ry <br />as c>a <br />(y) Ln <br />U U U <br />CJ1 <br />CJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />EJ3 <br />CJ3 <br />CJ1 <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />O <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />HETA20 <br />1810 <br />- <br />9- 10d x 1 1/2" <br />HTA20 <br />1615 <br />1585 <br />10 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />- <br />9 - 10d x 1 1/2" <br />HTA16 <br />1615 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />600 <br />535 <br />10 - 8d <br />RT7A <br />670 <br />565 <br />10 - 8d x 1 1/2' <br />D <br />H3 <br />455 <br />320 <br />8 - 8d <br />RT3 <br />610 <br />525 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />- <br />B - 10d x 1 1/2' <br />HTA20-18 <br />1400 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2235 <br />- <br />11 - 10d x 1 1/2" <br />- <br />- <br />- <br />- <br />G <br />HIOA <br />1340 <br />1015 <br />18 - 10d x 1 1/2' <br />RT16A <br />1380 <br />1160 <br />9 - 10d x 1 1/2" & 8 - 10d <br />H <br />HTT4 <br />3610 <br />3105 <br />5/8" ANCH. / (18) 10d x 1 1/2" <br />HTT4 <br />2715 <br />- <br />5/8" ANCH. / 30d x 1 1/2" <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) lOd x 1 1/2" <br />HTT5 <br />3225 <br />- <br />5/8" ANCH. / (28) 10d x 1 1/2" <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />2345 <br />- <br />2 - 5/8" DIA. BOLTS <br />L <br />HD5B * <br />4505 <br />3785 <br />5/8" ANCH. 3/4" STUD BOLTS <br />TDX6 <br />5320 <br />- <br />2 - 7/8" DIA. BOLTS <br />M <br />HD76 * <br />6645 <br />5650 <br />7/8" ANCH. 3/4" STUD BOLTS <br />TDX10 <br />7845 <br />- <br />4 - 7/8" DIA BOLTS <br />N <br />LUS26 <br />1165/1070 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1115/1060 ** <br />- <br />8 - 10d <br />P <br />HUS26 <br />1550/3335 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />1925/3295 <br />- <br />20 - 16d x 3 1/2" <br />Q <br />HUS28 <br />2000/4220 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2570/4345 <br />- <br />30 - 16d x 3 1/2" <br />R <br />MTS12 <br />1000 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14 - 10d x 1 1/2" <br />S <br />MTS16 <br />1000 <br />860 <br />14 - 10d x 1 1/2" <br />MTW16 <br />1195 <br />1005 <br />14 -10d x 1 1/2" <br />T <br />MTS20 <br />1000 <br />860 <br />14 - 10d x 1 1/2" <br />MTW20 <br />1195 <br />1005 <br />14 - 10d x 1 1/2" <br />U <br />MGT/MUGT <br />3965 <br />3330 <br />22 - 10d x (1) 5/8" ATR W/ 12" EMBED W/ SIMPSON "SET' EPDXY <br />V <br />LGT2 <br />2150 <br />1850 <br />(16)16d SINKERS & <br />(7) 1/4" x 2 1/4" TITENS <br />LUGT2 <br />1850 <br />1810 <br />(16) 10d NAILS & <br />(5) 1/4" x 3" WEDGE BOLTS <br />W. <br />HTS20 <br />1450 <br />1245 <br />24 - 10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24 - 10d x 1 1/2" <br />SPI <br />585 <br />535 <br />10 - 10d <br />SPT22 <br />685 <br />- <br />8 - 10d <br />SP2 <br />1065 <br />605 <br />12-10d <br />SPT24 <br />1030 <br />- <br />12-10d <br />HCP2 <br />1 645 <br />555 <br />12 - 10d x 1 1/2" <br />- <br />- <br />- <br />- <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS USP CIA-7000C <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. <br />LOADS: <br />ROOF = L/360 <br />FLOOR = LJ480 W/ 3/8" MAX DEFLECTION <br />FLOOR JOIST SPACING SHALL BE MAX OF 192' O.C. FOR HARDWOOD & TILE AREAS & 24" O.C. FOR CARPET AREAS, <br />DROP HIP DETAIL <br />2-0-0 MAXIMUM 5PACING ON VERTICAL5 OF (5) TRU55E5 <br />al <br />I OR 2 PLY <br />CARRIER <br />I-a-0 CLEAR CHAP BETWEEN (5) TRU55E5 (+/- 6") <br />(• •) FASTEN EACH (5) TRU55 WEB TO EACH (A) TRU55 TOP CHORD AT EVERY (*) <br />INTER5ECTING POINT 5HOWN ON THE HIP TRU55 5Y5TEM BELOW. FASTEN TOP <br />GHORD5 OF EACH (5) TRU55 TO THE TOP CHORDS OF (A) TRU55E5 AT EVERY <br />OTHER INTER5ECTING POINT (") INTER5ECTING POINT TO BE FA5TENED WITH 2-15d <br />COMMON NAIL5 OR 0.125 x 3" GUN NAIL5. FA5TEN BOTTOM CHORD OF (B) TRU55 TO <br />TOP CHORD OF CARRIER TRU55 WITH THE 5AME 5PECIFIED COMMON NAIL5 OR FUN I OR 2 PLY CARRIER (A) <br />NAIL5 AT 48"OC (*). W/ 2x CONT, LEDGER <br />IN LIEU OF PREFABRICATED HIP PLANING TRU55E5, (B) 2x4 5YP NO, 2 OR NO, 2 PT <br />5TICK LUMBER (LAIC) FLAT WISE) MAY BE USED, FOLLOW FA5TENING 50HEDULE A5 <br />DEFINED FOR HIP PLANING TRU55E5 RI. <br />5TICK FRAMING SPLICING 15 ALLOWED BETWEEN TRU55E5 OR AT TRU55 <br />INTER5ECTION6 5PLICING, <br />TO BE 5TAGGERED BETWEEN COMMON TRU55E5 NO CA15 REQUIRED UNDER STICK <br />FRAMING 5PLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-O" ON A HORIZONTAL PROJECTION. <br />NOTE: 5EE 5HEET D-1 FOR ROOF FRAMING DETAIL5 <br />NOTES: <br />I. (2)12d TOENAIL5 EACH 51DE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW TYP. AT INT, BEARING U.N.O. <br />ALL TRU55 TO MA50NRY STRAPS TO BE O U.N.O. <br />ALL TRU55 TO FRAME 5TRAP5 TO BE U.N.O. <br />N <br />.......... ?,AN <br />N S..�fiO���i,, <br />q : NO. 8S 3 '•�Z <br />STATE OF <br />ij'n•'• ` CORV N <br />ONAL C�, �N <br />��lllIII11\� <br />ROOF FRAMING PLAN - B <br />SCALE: 1/4" = I'-0" <br />DAVIS BEWS <br />DESIGN GROUP <br />150 STATE STREET EAST <br />OLD&MR, FLORIDA 34677 <br />813. 925.1300 TEL <br />813.925.1800 FAX <br />WWW.DAVISBEWS.CAM <br />TAMPA • DFI`TVER <br />EST. 1994 <br />VORTEX ENGINEERING, LLC. <br />607 S. ALEXANDER ST., SUITE 103 <br />PLANT CITY, FLORIDA 33563 <br />1.877.6VORTEX (686-7839) <br />COA 28035 <br />PAUL D. KIDWELL, P.E. #52683 <br />NDREW J. MEISHEID, P.E. #83217 <br />ASBED A. AVEDIKIAN, P.E. #86623 <br />1 HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE <br />WITH SECTION R301 OF THE FLORIDA BUILDING CODE, <br />RESIDENTIAL 6TH EDITION (2017). <br />THE ENGINEER HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANI LAYOUT TO <br />DETERMINE ANY LOAD BEARING CONDITIONS AND <br />RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER <br />TRUSS LOAD INFORMATION IS SUPPLIED TO THE <br />ENGINEER. <br />SEALED FOR STRUCTURE ONLY <br />!I <br />cO <br />Z <br />O <br />" � "o <br />> ur) ro <br />C) II (0Lr) <br />�L N II <br />Ia- C)- M <br />U Q00 <br />z� u <br />w Wo <br />..J O <br />110 <br />0z <br />0 <br />� 7 <br />Lj <br />z d <br />�a <br />W¢z cery <br />uz00 <br />z°¢Q <br />_ 8 n z <br />� J <br />z <br />a <br />a�U_o <br />OU LL <br />N <br />Ll <br />H w <br />z <br />�U <br />zw <br />a <br />z <br />9 <br />4� <br />w <br />z <br />H <br />O0 <br />^^ <br />V / <br />J <br />z <br />��¢ <br />tVan <br />6Wo <br />a <br />LL <br />a�FO <br />U Q Z <br />l0 <br />Z <br />ZD <br />pQLCL'O <br />Q <br />z 0 z U <br />O <br />CJ <br />a0QCJ <br />z <br />(� <br />O <br />powz <br />dam- <br />c- <br />w <br />N <br />Lu <br />W <br />W <br />=000¢ <br />u) o z x <br />aLU E <br />O <br />Q <br />Q <br />0000 <br />00 <br />Z <br />Z <br />Z <br />Z <br />CY <br />m <br />,-( <br />a�� <br />om <br />O <br />m <br />a <br />a <br />SCALE : AS <br />NOTED <br />DATE : 4/9/2019 <br />VERSION NO. <br />1.0 <br />SHEET NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.