OPTIONAL OVERHEAD SERVICE SAME AS
<br />150 = 01 COPPER OR 2/0 ALUMINUM
<br />UNDERGROUND 150 OR 200 AMP SERVICE
<br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT,
<br />METER
<br />TYPICAL A/C
<br />MAIN D15G. ELECTRICAL DISCONNECT
<br />150 OR PANEL
<br />REFER TO FLOOR PLAN FOR
<br />200 AMP 012 COPPER TO APPLIANCES AND GFI
<br />NOTED AMPS. REQUIRED
<br />114 COPPER TO LIGHTS AND OUTLETS
<br />010 COPPER TO WATER HEATER
<br />UNDERGROUND SERVICE
<br />S COPPER TO RANGE
<br />BY POWER COMPANY
<br />06 COPPER TO HvAC
<br />#4 GROUNDING WIRE WITH CODE
<br />APPROVED CLAMP PER 250.50
<br />AND 250.52 OF THE 2014 NEG.
<br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94
<br />ELECTRICAL RISER DIAGRAM
<br />NOTE:
<br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS
<br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY
<br />STAIR NOTES
<br />RAILING
<br />5ALU5TER5 SHALL BE 5PACED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH.
<br />HANDRAIL5
<br />HANDRAILS FOR 5TAIRWAY5 5HALL BE GONTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF
<br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST R15ER. HANDRAIL ENDS 5HALL BE RETURNED OR 5HALL TERMINATE IN NEWEL P05T5 OR
<br />54FETY TERMINALS. HANDRAIL5 ADJACENT TO A WALL 5HALL HAVE A SPACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS.
<br />CONTINUOUS GRASPABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA
<br />UNDER -STAIR PROTECTION
<br />ENCL05ED ACCESSIBLE SPACE UNDER 5TAIR5 5HALL HAVE WALLS, UNDER -STAIR 5URFAGE AND ANY SOFFIT PROTECTED ON THE
<br />ENCL05ED 51DE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11
<br />5TAIRWALL FRAME NOTE
<br />ALL STAIRWELL SURROUNDING WALLS AND KNEE WALLS ARE TO BE FRAMED AT V' O.C. TO PROTECT FROM FALLING HAZARD
<br />OCCUPANCY AND CONSTRUCTION TYPE:
<br />TH15 UNIT HA5 AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA551FICATION,
<br />CEILING CONSTRUCTION:
<br />1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED
<br />TO THE GARAGE 51DE. GARAGES BENEATH HABITABLE ROOMS 5HALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN
<br />5/8 INCH (15.9 mm) TYPE I'X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION 15 A FLOOR -CEILING A55EMBLY, THE STRUCTURE
<br />5UPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT.
<br />DUELLING / GARAGE OPENING5:
<br />I. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 1 3/8" IN THICKNE55,
<br />SOLID CORE (5.C.)OR HONEYCOMB CORE STEEL DOOR5 NOT LE55 THAN 1 3/S" THICK, OR 20 MINUTE FIRE RATED DOORS,
<br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN, FIRE RATING OF 20 MINUTE5.
<br />EGRE55:
<br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE
<br />WINDOW MUST NAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM.
<br />WINDOW INSTALLATION:
<br />WINDOW5 SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN
<br />INSTALLATION IN5TRUCTION5 SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.
<br />TERMITE PROTECTION:
<br />I, PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE 5LA15-ON-GRADE FLOORS 5HALL NOT BE OF GELLUL06E
<br />CONTAINING MATERIALS. IF 501L TREATMENT 15 USED FOR 5UBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL NAVE A MAXIMUM WALL
<br />THICKNE55 OF 0.010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PACE
<br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDE5 SHALL BE APPLIED IN51DE THE SLEEVE.
<br />2, PROTECTION AGAINST DECAY AND TERMITES. = CONDENSATE LINES, IRRIGATION / SPRINKLER 5Y5TEM R15ER5 FOR SPRAY HEAD5, AND ROOF
<br />DOWN5POUT5 SHALL DISCHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL
<br />EXTEN51ON5, OR 5PLA5H BLOCKS, GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHE5 (152 mm)
<br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF.
<br />TOP RAILING
<br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION
<br />54LU5TER5 TO NAILS ON WOOD COMPONENTS.
<br />MAX 5PACIN6 4"
<br />1 X 8 PAINTED WD, CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO
<br />OGEE STOP THE SIZE OF A 2 X 12 S.Y.P. AND 16 NAILED TO EACH
<br />TREAD W/ 166 NAILS FROM THIRD LAMINATE TO TREAD-
<br />OPT. 2 X 2 BLOCKING NAILED /
<br />TO TREAD AND RISER,
<br />3-2 X 12 STRINGER 2 X BLOCKING NAILED TO STRINGER, Z+
<br />3/4" R15ER5 RISER, AND TREAD. +
<br />2 X TREADS} RIP FROM 2x12 I X 5PRUCE 03 OR 3/4" GDX. + +
<br />+
<br />TO SIZE NOTED ON PLAN PLYWD. RISER,
<br />2 X SOUTHERN YELLOW PINE 01
<br />(ACTUAL THICKNE55 15 1 1/2") TREAD.
<br />TYP. OPT. RAILING ELEVATION
<br />SCALE: 1/2" - I'-0"
<br />NEWEL POST
<br />TOP RAILING
<br />BALUSTER 4" O.C.
<br />SHOE RAIL (REMOVE
<br />W/ METAL SPINDLES)
<br />I X 8 PAINTED WE). CAP
<br />OGEE STOP
<br />3
<br />OPTIONAL
<br />&MMN5-aw;�
<br />CLOSED RISER DETAIL
<br />SCALE: 1/2" - 1'-0"
<br />CARPS
<br />CARPS
<br />TREAC
<br />R15ER
<br />2 X 4 WALL
<br />1/2" GYP BD.
<br />3/4" 5KIRT BD.
<br />2 X 4 SPACER
<br />2X12
<br />STRINGER
<br />TYPICAL STAIR
<br />FRAMING DETAIL
<br />B SCALE: 3/4" = I'-0"
<br />GENERAL CONSTRUCTION NOTES
<br />CHAPTERS AND 5ECTION5 REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011)
<br />MECHANICAL AND HYAC
<br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO
<br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT.
<br />2, MECHANICAL APPLIANCES SHALL BE ACCE5515LE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT
<br />CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED,
<br />REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE SHALL BE PROVIDED IN
<br />FRONT OF THE CONTROL 51DE TO SERVICE AN APPLIANCE.
<br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
<br />CONSTRUCTED OF A MIN. 126 GAUGE (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE,
<br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 SHALL BE RA15ED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FINISHED
<br />GRADE AND SHALL AL50 CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS,
<br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO
<br />ANY BUILDING COMPONENT WILL OCCUR A5 A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING 5Y5TEM. THE5E PANS SHALL BE
<br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV15ION5 OF 5ECTION5 MI411.3.
<br />EXHAUST FANS AND VENTING
<br />(.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE D15CHARGED TO THE OUTDOORS, AIR SHALL
<br />NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL 5PACE.
<br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND
<br />SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM 5ATHROOM5 AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC,
<br />CRAWL SPACE, OR OTHER AREAS IN51DE THE BUILDING.
<br />3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE
<br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND
<br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION
<br />DUCT.
<br />EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF
<br />THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE B005TER FAN MANUFACTURER'S
<br />INSTALLATION IN5TRUCTION5. WHERE A GLOTHE5 DRYER 5005TER FAN 15 INSTALLED AND NOT READILY ACCE5515LE FROM THE ROOM IN WHICH
<br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE
<br />LABEL 5HALL BEAR THE WORDS "TH15 DRYER EXHAUST 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN.('
<br />4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH
<br />AMGA STANDARD 550 IN FBC,
<br />ROUGH- IN INSPECTION REQUEST NOTE
<br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MUST BE
<br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE
<br />FRAMING INSPECTION.
<br />WINDOW FALL PROTECTION
<br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15
<br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FINISHED GRADE OR
<br />5URFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE
<br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED
<br />FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE
<br />5ECTION5 OF WINDOW5 SHALL NOT PERMIT OPENINGS THAT ALLOW
<br />PA55AGE OF A 4 INGH DIAMETER SPHERE WHERE SUCH OPENINGS
<br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER F.B.C.
<br />RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2.
<br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE
<br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090
<br />PER F.B.C. RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2,
<br />INSULATION NOTES
<br />• GMU WALL5:=---- R-FOIL 4.1 • KNEE WALLS THAT
<br />BACK UP TO CEILING
<br />• FRAME WALLS:-------- R-13 AREA ONLY: --- =------ = R-19
<br />• CEILING:------------- R-30
<br />ON51TE FOUNDATION 5URVEY NOTE
<br />A FOUNDATION SURVEY 5HALL BE PERFORMED AND A COPY OF THE
<br />SURVEY 5HALL BE ON THE SITE FOR THE BUILDING IN5PECTOR'5 U5E,
<br />OR ALL PROPERTY MARKERS 5HALL BE EXPO5ED AND A STRING
<br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED
<br />5ETBACK5.
<br />CELING AT ENTRY NOTE
<br />ALL ENTRY CLG5. TO BE 15/32 056. CEMENTITOU5 FINISH (U.N.0)
<br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE
<br />PROTECTION OF GAS APPLIANCES IN RESIDENTIAL GARAGES:
<br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE
<br />SLAB AND 3 FT, ABOVE FINISHED FLOOR,
<br />GENERAL NOTES
<br />• DUE TO VARIATIONS IN CITY REQUIREMENTS, SUBDIV1510N
<br />5PECIFICATION5, CONSTRUCTION TECHNIQUES, DIVERSITY IN
<br />MATERIALS, AND PLAN REV151ON5, ALL DIMEN51ON5 AND
<br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD
<br />CONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE
<br />PROCEEDING WITH CONSTRUCTION.
<br />• ELECTRICAL LOCATIONS 5LIM ON DRAWINGS MAY BE CHANGED
<br />AT THE 50LE DISCRETION OF CALATLANTIC HOMES OR IT5
<br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND
<br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC
<br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLETS
<br />AND / OR 5WITCHE5 5HOWN.
<br />• ALL PLUMBING DIMENSIONS ARE APPROXIMATE FROM THE CENTER
<br />LINE OF THE FIXTURE TO THE EXTERIOR 5LA5 EDGE. IT 15 THE
<br />RESPONSIBILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF
<br />ALL PLUMBING DIMEN61ON5.
<br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWINGS REFERENCING
<br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CONSIDERED "NOMINAL DIMEN51ON5"
<br />CHIMNEY HEIGHT REQUIREMENTS:
<br />WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLED THE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT
<br />EXTENDS THROUGH THE ROOF AND MUST BE 2'-0'I NIGHER THAN THE ROOF OR RIDGE THAT 15 10'=0" AWAY OR CL05ER.
<br />TUB AND 5HOWER ARE45:
<br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH 45TM 0280, C1325, OR CI118
<br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION6 SHALL BE U5ED 45 BACKER5 FOR WALL TILE IN TUB AND
<br />5HOWER AREAS, AND WALL PANELS IN 5HOWER AREAS.
<br />FLOOD ZONE REQUIREMENTS:
<br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION.
<br />BEWS
<br />DESIGN GROVP
<br />150 STATE STREET FAST
<br />OLDSMAR, FLORIDA 346T7
<br />813.92,5.1300 TEL
<br />813.925.1800 FAX
<br />W W W.DAVLSBEWS.COM
<br />TAMPA • DENVER.
<br /><-=-�--a EST. 1994 �
<br />i
<br />0
<br />z o
<br />ON
<br />o
<br />(/) M O
<br />���U)
<br />tn
<br />Q CL
<br />M
<br />oC V Q 00
<br />z���
<br />w wo
<br />J �
<br />ko
<br />d'
<br />J
<br />oz
<br />�o
<br />�s
<br />W�
<br />za
<br />z�
<br /><a
<br />w Q a
<br />. ^ oQ�O
<br />LLJ
<br />F--1 o W z
<br />y _l
<br />d � LL O
<br />UU w N
<br />w mWo
<br />o�
<br />zz
<br />rg
<br />zW
<br />z z g
<br />0 ��
<br />Ov p Q
<br />Ow
<br />Cn w
<br />oC
<br />z Q�w
<br />Q O \
<br />z
<br />LLJU z o0
<br />w z F-
<br />z � � �
<br />m z
<br />° g W � m
<br />SCALE : AS NOTED
<br />DATE : 10-19-2018
<br />VERSION NO.
<br />ino
<br />SHEET NO.
<br />DT1
<br />DAVIS
<br />I
<br />
|