OPTIONAL OVERHEAD SERVICE SAME AS <br />150 = 01 COPPER OR 2/0 ALUMINUM <br />UNDERGROUND 150 OR 200 AMP SERVICE <br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT, <br />METER <br />TYPICAL A/C <br />MAIN D15G. ELECTRICAL DISCONNECT <br />150 OR PANEL <br />REFER TO FLOOR PLAN FOR <br />200 AMP 012 COPPER TO APPLIANCES AND GFI <br />NOTED AMPS. REQUIRED <br />114 COPPER TO LIGHTS AND OUTLETS <br />010 COPPER TO WATER HEATER <br />UNDERGROUND SERVICE <br />S COPPER TO RANGE <br />BY POWER COMPANY <br />06 COPPER TO HvAC <br />#4 GROUNDING WIRE WITH CODE <br />APPROVED CLAMP PER 250.50 <br />AND 250.52 OF THE 2014 NEG. <br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94 <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS <br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />STAIR NOTES <br />RAILING <br />5ALU5TER5 SHALL BE 5PACED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH. <br />HANDRAIL5 <br />HANDRAILS FOR 5TAIRWAY5 5HALL BE GONTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST R15ER. HANDRAIL ENDS 5HALL BE RETURNED OR 5HALL TERMINATE IN NEWEL P05T5 OR <br />54FETY TERMINALS. HANDRAIL5 ADJACENT TO A WALL 5HALL HAVE A SPACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS. <br />CONTINUOUS GRASPABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER -STAIR PROTECTION <br />ENCL05ED ACCESSIBLE SPACE UNDER 5TAIR5 5HALL HAVE WALLS, UNDER -STAIR 5URFAGE AND ANY SOFFIT PROTECTED ON THE <br />ENCL05ED 51DE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11 <br />5TAIRWALL FRAME NOTE <br />ALL STAIRWELL SURROUNDING WALLS AND KNEE WALLS ARE TO BE FRAMED AT V' O.C. TO PROTECT FROM FALLING HAZARD <br />OCCUPANCY AND CONSTRUCTION TYPE: <br />TH15 UNIT HA5 AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA551FICATION, <br />CEILING CONSTRUCTION: <br />1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED <br />TO THE GARAGE 51DE. GARAGES BENEATH HABITABLE ROOMS 5HALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN <br />5/8 INCH (15.9 mm) TYPE I'X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION 15 A FLOOR -CEILING A55EMBLY, THE STRUCTURE <br />5UPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT. <br />DUELLING / GARAGE OPENING5: <br />I. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 1 3/8" IN THICKNE55, <br />SOLID CORE (5.C.)OR HONEYCOMB CORE STEEL DOOR5 NOT LE55 THAN 1 3/S" THICK, OR 20 MINUTE FIRE RATED DOORS, <br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN, FIRE RATING OF 20 MINUTE5. <br />EGRE55: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE <br />WINDOW MUST NAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. <br />WINDOW INSTALLATION: <br />WINDOW5 SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN <br />INSTALLATION IN5TRUCTION5 SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />TERMITE PROTECTION: <br />I, PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE 5LA15-ON-GRADE FLOORS 5HALL NOT BE OF GELLUL06E <br />CONTAINING MATERIALS. IF 501L TREATMENT 15 USED FOR 5UBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL NAVE A MAXIMUM WALL <br />THICKNE55 OF 0.010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PACE <br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDE5 SHALL BE APPLIED IN51DE THE SLEEVE. <br />2, PROTECTION AGAINST DECAY AND TERMITES. = CONDENSATE LINES, IRRIGATION / SPRINKLER 5Y5TEM R15ER5 FOR SPRAY HEAD5, AND ROOF <br />DOWN5POUT5 SHALL DISCHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTEN51ON5, OR 5PLA5H BLOCKS, GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHE5 (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. <br />TOP RAILING <br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION <br />54LU5TER5 TO NAILS ON WOOD COMPONENTS. <br />MAX 5PACIN6 4" <br />1 X 8 PAINTED WD, CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO <br />OGEE STOP THE SIZE OF A 2 X 12 S.Y.P. AND 16 NAILED TO EACH <br />TREAD W/ 166 NAILS FROM THIRD LAMINATE TO TREAD- <br />OPT. 2 X 2 BLOCKING NAILED / <br />TO TREAD AND RISER, <br />3-2 X 12 STRINGER 2 X BLOCKING NAILED TO STRINGER, Z+ <br />3/4" R15ER5 RISER, AND TREAD. + <br />2 X TREADS} RIP FROM 2x12 I X 5PRUCE 03 OR 3/4" GDX. + + <br />+ <br />TO SIZE NOTED ON PLAN PLYWD. RISER, <br />2 X SOUTHERN YELLOW PINE 01 <br />(ACTUAL THICKNE55 15 1 1/2") TREAD. <br />TYP. OPT. RAILING ELEVATION <br />SCALE: 1/2" - I'-0" <br />NEWEL POST <br />TOP RAILING <br />BALUSTER 4" O.C. <br />SHOE RAIL (REMOVE <br />W/ METAL SPINDLES) <br />I X 8 PAINTED WE). CAP <br />OGEE STOP <br />3 <br />OPTIONAL <br />&MMN5-aw;� <br />CLOSED RISER DETAIL <br />SCALE: 1/2" - 1'-0" <br />CARPS <br />CARPS <br />TREAC <br />R15ER <br />2 X 4 WALL <br />1/2" GYP BD. <br />3/4" 5KIRT BD. <br />2 X 4 SPACER <br />2X12 <br />STRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B SCALE: 3/4" = I'-0" <br />GENERAL CONSTRUCTION NOTES <br />CHAPTERS AND 5ECTION5 REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011) <br />MECHANICAL AND HYAC <br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO <br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT. <br />2, MECHANICAL APPLIANCES SHALL BE ACCE5515LE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, <br />REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE SHALL BE PROVIDED IN <br />FRONT OF THE CONTROL 51DE TO SERVICE AN APPLIANCE. <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE <br />CONSTRUCTED OF A MIN. 126 GAUGE (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE, <br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 SHALL BE RA15ED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FINISHED <br />GRADE AND SHALL AL50 CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR A5 A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING 5Y5TEM. THE5E PANS SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV15ION5 OF 5ECTION5 MI411.3. <br />EXHAUST FANS AND VENTING <br />(.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE D15CHARGED TO THE OUTDOORS, AIR SHALL <br />NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL 5PACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND <br />SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM 5ATHROOM5 AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, <br />CRAWL SPACE, OR OTHER AREAS IN51DE THE BUILDING. <br />3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND <br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE B005TER FAN MANUFACTURER'S <br />INSTALLATION IN5TRUCTION5. WHERE A GLOTHE5 DRYER 5005TER FAN 15 INSTALLED AND NOT READILY ACCE5515LE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE <br />LABEL 5HALL BEAR THE WORDS "TH15 DRYER EXHAUST 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN.(' <br />4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH <br />AMGA STANDARD 550 IN FBC, <br />ROUGH- IN INSPECTION REQUEST NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MUST BE <br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE <br />FRAMING INSPECTION. <br />WINDOW FALL PROTECTION <br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 <br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FINISHED GRADE OR <br />5URFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE <br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE <br />5ECTION5 OF WINDOW5 SHALL NOT PERMIT OPENINGS THAT ALLOW <br />PA55AGE OF A 4 INGH DIAMETER SPHERE WHERE SUCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER F.B.C. <br />RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2. <br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE <br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 <br />PER F.B.C. RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2, <br />INSULATION NOTES <br />• GMU WALL5:=---- R-FOIL 4.1 • KNEE WALLS THAT <br />BACK UP TO CEILING <br />• FRAME WALLS:-------- R-13 AREA ONLY: --- =------ = R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URVEY NOTE <br />A FOUNDATION SURVEY 5HALL BE PERFORMED AND A COPY OF THE <br />SURVEY 5HALL BE ON THE SITE FOR THE BUILDING IN5PECTOR'5 U5E, <br />OR ALL PROPERTY MARKERS 5HALL BE EXPO5ED AND A STRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />5ETBACK5. <br />CELING AT ENTRY NOTE <br />ALL ENTRY CLG5. TO BE 15/32 056. CEMENTITOU5 FINISH (U.N.0) <br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE <br />PROTECTION OF GAS APPLIANCES IN RESIDENTIAL GARAGES: <br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE <br />SLAB AND 3 FT, ABOVE FINISHED FLOOR, <br />GENERAL NOTES <br />• DUE TO VARIATIONS IN CITY REQUIREMENTS, SUBDIV1510N <br />5PECIFICATION5, CONSTRUCTION TECHNIQUES, DIVERSITY IN <br />MATERIALS, AND PLAN REV151ON5, ALL DIMEN51ON5 AND <br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD <br />CONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE <br />PROCEEDING WITH CONSTRUCTION. <br />• ELECTRICAL LOCATIONS 5LIM ON DRAWINGS MAY BE CHANGED <br />AT THE 50LE DISCRETION OF CALATLANTIC HOMES OR IT5 <br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC <br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLETS <br />AND / OR 5WITCHE5 5HOWN. <br />• ALL PLUMBING DIMENSIONS ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR 5LA5 EDGE. IT 15 THE <br />RESPONSIBILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMEN61ON5. <br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWINGS REFERENCING <br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CONSIDERED "NOMINAL DIMEN51ON5" <br />CHIMNEY HEIGHT REQUIREMENTS: <br />WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLED THE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT <br />EXTENDS THROUGH THE ROOF AND MUST BE 2'-0'I NIGHER THAN THE ROOF OR RIDGE THAT 15 10'=0" AWAY OR CL05ER. <br />TUB AND 5HOWER ARE45: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH 45TM 0280, C1325, OR CI118 <br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION6 SHALL BE U5ED 45 BACKER5 FOR WALL TILE IN TUB AND <br />5HOWER AREAS, AND WALL PANELS IN 5HOWER AREAS. <br />FLOOD ZONE REQUIREMENTS: <br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. <br />BEWS <br />DESIGN GROVP <br />150 STATE STREET FAST <br />OLDSMAR, FLORIDA 346T7 <br />813.92,5.1300 TEL <br />813.925.1800 FAX <br />W W W.DAVLSBEWS.COM <br />TAMPA • DENVER. <br /><-=-�--a EST. 1994 � <br />i <br />0 <br />z o <br />ON <br />o <br />(/) M O <br />���U) <br />tn <br />Q CL <br />M <br />oC V Q 00 <br />z��� <br />w wo <br />J � <br />ko <br />d' <br />J <br />oz <br />�o <br />�s <br />W� <br />za <br />z� <br /><a <br />w Q a <br />. ^ oQ�O <br />LLJ <br />F--1 o W z <br />y _l <br />d � LL O <br />UU w N <br />w mWo <br />o� <br />zz <br />rg <br />zW <br />z z g <br />0 �� <br />Ov p Q <br />Ow <br />Cn w <br />oC <br />z Q�w <br />Q O \ <br />z <br />LLJU z o0 <br />w z F- <br />z � � � <br />m z <br />° g W � m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />ino <br />SHEET NO. <br />DT1 <br />DAVIS <br />I <br />