GENERAL F)RICK/5TONE NOTE5 (WHERE ARRLIGA5LE)
<br />BRICK/STONE 5HALL BE 5ELF SUPPORTING. MASON 5HALL PROVIDE ANGLE 5UPPORT AT
<br />OPENINGS 5UCH THAT IT 5PAN5 THE OPENING AND DOES NOT ADD WEIGHT TO HEADERS.
<br />HEADER5 PROVIDE LATERAL 5UPPORT ONLY,
<br />AT MASONRY, USE 6"X6"X3/8" STEEL ANGLE W/ 1/2" DIA. X 5" 51MP5ON TITEN HD ANCHOR5 9 24"
<br />O.C. W/ 4" LAP ONTO BRICK 5UPPORT ON EITHER 51DE MINIMUM, ANGLE 51ZE PER B.I.A. AND
<br />F.B.C. CRITERIA, OR BY OTHER5.
<br />AT FRAME, USE 5"X5"X3/8" STEEL ANGLE W/ 3/8" DIA. X 4" LAG 5CREW5 0 1? O.C. W/ 4" LAP
<br />ONTO BRICK 5UPPORT ON EITHER 51DE MINIMUM. ANGLE 51ZE PER B.I.A. AND FB.C. CRITERIA, OR
<br />BY OTHER5.
<br />BRICK/5TONE TIES, ANGLE5 5UPPORT5, AE5THETIC FIN15HE5 5HALL BE INSTALLED IN
<br />ACCORDANCE WITH THE TM5 402/ACI 530/A5CE 5 A5 APPLICABLE,
<br />VORTEX ENGINEERING, LLC.15 NOT RE5PON51BLE FOR BRICK/STONE INSTALLATION
<br />INFORMATION, A5 BRICK/STONE DESIGN 15 BY OTHERS.
<br />SECOND FLOOR AREAS NOT IN ALIGNMENT WITH FIRST FLOOR AREA5 HAVE BEEN A55UMED TO
<br />REQUIRE BRICK/5TONE BEARING ON TRU55 5Y5TEM BELOW. TRU55 MANUFACTURER TO INCLUDE
<br />ADDITIONAL DEAD LOAD FOR 5UCH AREAS, AND LIMIT DEFLECTION TO L/600 IN THESE AREA5
<br />FOR PURP05E5 OF BRICK SUPPORT,
<br />FOUNDATIONS HAVE BEEN 61ZED FOR THE ADDITIONAL DEAD LOAD DUE TO BRICK/STONE,
<br />BRICK/STONE AND ITS 5UPPORT EXCEPT A5 NOTED 15 BY OTHERS. NOTED CRITERIA 15 A
<br />MINIMUM STANDARD. TIES, FLA514ING5, WEEP5, CONTROL JOINT5, AND ALL OTHER BRICK/5TONE
<br />CRITERIA 15 BY OTHERS.
<br />THE NOTE5 ABOVE PERTAIN TO CLAY BRICK MA50NRY AND NATURAL STONE. 51MULATED
<br />PRODUCTS AND VENEER5 5HALL BE INSTALLED PER MANUFACTURER'5 5PECIFICATION5 AND
<br />THEIR FLORIDA PRODUCT APPROVAL OR MIAMI/DADE NOA.
<br />CHEMICAL TERMITE TREATMENT NOTE5
<br />I " A PEMANENT 51GN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR
<br />RE-IN5PECTION AND TREATMENT CONTRACT RENEWAL 5HALL BE PROVIDED, THE SIGN 5HALL BE
<br />P05TED NEAR THE WATER HEATER AND ELECTRICAL PANEL."
<br />2, CONDENSATE AND ROOF DOWN5POUT5 5HALL D15CHARGE AT LEAST 1'-0" FROM BUILDING
<br />51DEWALL5.
<br />3. IRRIGATION/SPRINKLER 5Y5TEM5 INCLUDING ALL R15ER5 AND SPRAY HEADS 5HALL NOT BE
<br />IN5TALLED WITHIN 1'-0" OF THE BUILDING 51DEWALL5,
<br />4. TERMITE PROTECTION 5HALL BE PROVIDED BY REGISTERED TERMITICIDE5 INCLUDING 501L
<br />APPLIED TERMITICIDE5, BAITING SYSTEM&, OR TERMITICIDE5 APPLIED TO WOOD OR OTHER
<br />APPROVED METHODS LABELED FOR PREVENTATIVE TREATMENT FOR NEW CONSTRUCTION. UPON
<br />COMPLETION OF TREATMENT/APPLICATION A CERTIFICATE OF COMPLIANCE SHALL BE 155UED BY
<br />A LICEN5ED PEST CONTROL OPERATOR
<br />5. BOXED AREA5 IN CONCRETE FLOOR5 FOR 5U55EQUENT INSTALLATION OF TRAP5, ETC., 5HALL
<br />BE MADE WITH PERMANENT METAL OR PLA5TIC FORM5.
<br />6. MINIMUM 6 MIL, VAPOR RETARDER MUST BE INSTALLED
<br />1. CONCRETE OVERPOUR AND MORTAT ALONG THE FOUNDATION PERIMETER MUST BE REMOVED
<br />8. ALL BUILDING5 ARE REQUIRED TO HAVE PRE-CON5TRUCTION TREATMENT.
<br />a A CERTIFICATE OF COMPLIANCE MUST BE 155UED TO THE BUILDING DEPARTMENT BY A
<br />LICEN5ED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE 1551JED,
<br />THE CERTIFICATE OF COMPLIANCE 5HALL 5TATE "THE BUILDING HA5 RECEIVED A COMPLETE
<br />TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITE5. THE TREATMENT 15 IN
<br />ACCORDANCE WITH THE RULE5 AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND
<br />CON5UMER SERVICES."
<br />10. NO WOOD, VEGETATION, 5TUMP5, CARDBOARD, TRA5H, ETC. 5HALL BE BURIED WITHIN 15'-0" OF
<br />ANY BUILDING OR PROP05ED BUILDING
<br />M/I SGD R.O. SCHEDULE
<br />SIZE
<br />"R.O. CMU
<br />(Flange)"
<br />"R.O. FRAME
<br />(Fin)"
<br />5068
<br />62 X 81 1/2
<br />60 1/2 X 80 1/2
<br />5080
<br />62 X 97 1/2
<br />60 1/2 X 96 1/2
<br />6068
<br />74 X 81 1/2
<br />72 1/2 X 80 1/2
<br />6080
<br />74 X 97 1/2
<br />72 1/2 X 96 1/2
<br />8068
<br />98 X 81 1/2
<br />96 1/2 X 80 1/2
<br />8080
<br />98 X 97 1/2
<br />96 1/2 X 96 1/2
<br />9080
<br />108 3/4 X 97 1/2
<br />107 1/4 X 96 1/2
<br />10080
<br />120 X 97 1/2
<br />119 X 96 1/2
<br />12080
<br />145 X 97 1/2
<br />145 3/4 X 96 1/2
<br />16080
<br />(4-panel)
<br />191 1/4 X 97 1/2 (from
<br />recess)
<br />189 1/2 X 96 1/2 (from
<br />recess)
<br />9080
<br />POCKET
<br />143 X 96 1/2 - finish 107
<br />X 96 1/2
<br />N/A
<br />12080
<br />POCKET
<br />(STD.)
<br />194 X 97 1/2 - finish 144
<br />X 97 j
<br />N/A
<br />12080
<br />POCKET
<br />(UPGRADED)
<br />194 X 99 - finish 144 X
<br />99
<br />N/A
<br />RO HEIGHT IN BLOCK TO BE FROM RECESS
<br />WINDOW SCHEDULE
<br />Size
<br />"R.O. CMU
<br />(Flange)"
<br />"R.O.
<br />(Fin)"
<br />Type
<br />13
<br />20 1/8 X 38 3/8
<br />18 5/8 X 37 7/8
<br />S.H.
<br />15
<br />20 1/8 X 63
<br />18 5/8 X 62 1/2
<br />S.H.
<br />22
<br />38 X 26
<br />N/A
<br />S.H.
<br />23
<br />38 X 38 3/8
<br />36 1/2 X 37 7/8
<br />S.H.
<br />24
<br />38 X 51 3/8
<br />36 1/2 X 50 1/8
<br />S.H.
<br />25
<br />38 X 63
<br />36 1/2 X 62 1/2
<br />S.H.
<br />26
<br />38 X 72
<br />36 1/2 X 71 1/2
<br />S.H.
<br />34
<br />54 1/8 X 63
<br />52 5/8 X 50 1/8
<br />S.H.
<br />35 RH
<br />54 X 70
<br />N/A
<br />S.H.
<br />35
<br />54 1/8 X 63
<br />52 5/8 X 62 1/2
<br />S.H.
<br />36
<br />54 1/8 X 72
<br />52 5/8 X 71 1/2
<br />S.H.
<br />1414
<br />17X16
<br />16X16
<br />P.W.
<br />1420
<br />17 X 24
<br />16 X 24
<br />P.W.
<br />1626
<br />N/A
<br />18 X 30
<br />P.W.
<br />1630
<br />N/A
<br />18 X 36
<br />S.H.
<br />1650
<br />N/A
<br />18 X 60
<br />S.H.
<br />2014
<br />25 x 16
<br />24 X 16
<br />P.W.
<br />2020
<br />25 x 24
<br />24 X 24
<br />P.W.
<br />2026
<br />25 1/5 x 30 1/2
<br />24 X 30
<br />P.W.
<br />2030
<br />N/A
<br />24 X 36
<br />S.H.
<br />2030
<br />25 X 36
<br />24 X 36
<br />P.W.
<br />2040
<br />N/A
<br />24 X 48
<br />S.H.
<br />2044
<br />N/A
<br />24 X 52
<br />P.W.
<br />2050
<br />N/A
<br />24 X 60
<br />S.H.
<br />2424
<br />29 X 28
<br />28 X 28
<br />P.W.
<br />2436
<br />N/A
<br />28 X 42
<br />S.H.
<br />2440
<br />N/A
<br />28 X 48
<br />S.H.
<br />2640
<br />N/A
<br />30 X 48
<br />S.H.
<br />2650
<br />N/A
<br />30 X 60
<br />S.H.
<br />3014
<br />37 1/2 X 16 1/2
<br />36 X 16
<br />P.W.
<br />3020
<br />37 3/4 X 24 1/2
<br />36 1/4 X 24
<br />P.W.
<br />3030
<br />N/A
<br />36 X 36
<br />S.H.
<br />3030
<br />37 X 36
<br />36 X 36
<br />P.W.
<br />3040
<br />N/A
<br />36 X 48
<br />S.H.
<br />3046
<br />N/A
<br />36 X 52 5/8
<br />S.H.
<br />3050
<br />N/A
<br />36 X 60
<br />S.H.
<br />3650
<br />N/A
<br />42 X 60
<br />S.H.
<br />4010
<br />49 X 12
<br />48 X 12
<br />P.W.
<br />4014
<br />49 X 16
<br />48 X 16
<br />P.W.
<br />4020
<br />N/A
<br />48 X 24
<br />P.W.
<br />4030
<br />N/A
<br />48 X 36
<br />S.H.
<br />4040
<br />N/A
<br />48 X 48
<br />S.H.
<br />4050
<br />N/A
<br />48 X 60
<br />S.H.
<br />4060
<br />49 X 72
<br />48 X 72
<br />S.H.
<br />4650
<br />55 X 60
<br />54 X 60
<br />S.H.
<br />5040
<br />N/A
<br />60 X 48
<br />H.R.
<br />6050
<br />73 1/2 X 60 3/4
<br />72 X 60 1/4
<br />P.W.
<br />6060
<br />73 1/2 X 72 1/2
<br />72 X 72
<br />P.W.
<br />2 (26)
<br />75 X 72 1/8
<br />N/A
<br />S.H.
<br />25 W/ Circle
<br />Top
<br />38 X 85
<br />36 1/2 X 84 1/2
<br />S.H.
<br />26 w/ Circle
<br />Top
<br />38 X 94
<br />36 1/2 X 93 1/2
<br />S.H.
<br />35 w/ Circle
<br />Top
<br />54 1/8 X 93
<br />52 5/8 X 92 1/2
<br />S.H.
<br />4650 P.W.
<br />55 X 60
<br />54 X 60
<br />P.W.
<br />H24
<br />27 1/2 X 50 5/8
<br />N/A
<br />S.H.
<br />H32
<br />27 1/2 X 26
<br />N/A
<br />S.H.
<br />H33
<br />27 1/2 X 38 3/8
<br />26 X 37 7/8
<br />S.H.
<br />H34
<br />27 1/2 X 50 5/8
<br />26 X 50 1/8
<br />S.H.
<br />H34 w/ Circle
<br />Top
<br />27 1/2 X 67 3/8
<br />25 3/4 X 63
<br />S.H.
<br />H35
<br />27 1/2 X 63
<br />26 X 62 1/2
<br />S.H.
<br />H36
<br />27 1/2 X 72
<br />26 X 71 1/2
<br />S.H.
<br />WALL
<br />PLAN VIEW
<br />1 CONTROL JOINT DETAIL
<br />SCALE: N.T.5,
<br />2x4 FRAI`
<br />WALL
<br />1/2" DRY
<br />PAPER BACKED
<br />METAL LATH
<br />3 COAT STUCCO FIN15H
<br />(CEMENT PLA5TER)
<br />CONTROL JOINT
<br />NOTE:
<br />TIE LATH TO FLANGE OF CONTROL
<br />JOINT AT 6" O.C. (NO PENETRATIONS
<br />5HALL BE MADE THROUGH THE
<br />CONTROL JOINT FLANGE)
<br />EXTERIOR WALL
<br />SHEATHING
<br />3 STUCCO CONTROL JOINT DETAIL OVER FRAM
<br />5CALE: N.T.5.
<br />6 JIV
<br />5CALE: N.T.5.
<br />SEAT IN CONCRETE 5LAB
<br />G�T 5 RE E 5LAB B
<br />TUCCO
<br />ZFRAME
<br />CONSTRUCTION 7
<br />LATH 15 REQUIRED TO
<br />BE D15CONTINUOU5
<br />BEHIND TH15 JOINT
<br />FRAME
<br />CONSTRUCTION
<br />MASONRY
<br />CONSTRUCTION
<br />CEMENT PL45TER(5TUCCO)
<br />5HEANING BOARD
<br />5ELF - FURRING LATH
<br />WATER RE515TANT BARRIER (2 LAYER5)
<br />LAP OVER WEEP SCREED AND BELOW
<br />END OF SHEATHING BOARD
<br />6" 5ELF ADHESIVE
<br />MEMBRANE TAPE
<br />TERMINATE THE 5ELF-FURRING LATH
<br />1/8" -1/4" ABOVE THE GROUND OF
<br />THE M.WW.5.
<br />WEEP 5CREED
<br />CONTROL JOINT
<br />STUCCO FIN15H
<br />A5TM 1063
<br />1.11.4.1 CONTROL JOINT5 - CONTROL (EXPAN510N AND CONTRACTION) JOINT5 5HALL BE IN5TALLED IN WALLS NOT MORE THAN 144 FT. 5Q.(13.4 M 5Q.) IN AREA
<br />AND NOT MORE THAN AREA5 OF 100 FT. 50. (9.30 M 5Q.) FOR ALL HORIZONTAL APPLICATION5, THAT 15, CEILING5, CURVES, OR ANGLE TYPE 5TRUCTURE5.
<br />1.11,41 THE D15TANCE BETWEEN CONTROL JOINT5 5HALL NOT EXCEED IS FT, (5.5M) IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 7✓ TO I. A CONTROL
<br />JOINT 5HALL BE INSTALLED WHERE THE CEILING FRAMING OR FURRING CHANGES DIRECTION,
<br />1,11.4.3 A CONTROL JOINT OR EXPAN51ON JOINT 5HALL BE INSTALLED WHERE AN EXPAN51ON JOINT OCCURS IN THE BASE EXTERIOR WALL.
<br />2 HORIZONTAL MID -WALL WEEP SCREED AT FRAME TO MASONRY
<br />SCALE: N.T.5.
<br />WATER RE515TANT
<br />BARRIER (CONTINUOU5
<br />BEHIND CONTROL JOINT)
<br />5ELF-FURRING V-GROOVE
<br />LATH, CONTINUOUS BEHIND
<br />CONTROL JOINT
<br />CONTROL JOINT
<br />ATTACH CONTROL JOINT
<br />TO LATH WITH GALV. WIRE
<br />TIE, METAL CORRO51ON
<br />WIRE TIE, OR 15 LB,
<br />TENSILE 5TRENGTH ZIP TIE
<br />1/5" NOMINAL CEMENT
<br />PLASTER OVER FRAME
<br />CON5TRUCTION (5TUCCO)
<br />-5HEATHING BOARD
<br />CONTROL JOINT HORIZONTAL OR
<br />4 VERTICAL AT FRAME
<br />5CALE: N.T.5.
<br />5HEATHING
<br />TWO LAYER5 WRB
<br />6" 5TRIP OF 5AF
<br />D15CONTINUOU5
<br />LATH BEHIND C.J.
<br />PER A5TM C1063
<br />LATH ATTACHED TO
<br />FRAMING MEMBERS ONLY
<br />CONTROL JOINT
<br />ATTACH CONTROL JOINT
<br />TO LATH WITH GALV, WIRE
<br />TIE, METAL CORRO51ON
<br />WIRE TIE, OR 15 LB.
<br />TEN5ILE STRENGTH ZIP TIE
<br />CONTROL JOINT DETAIL STUD
<br />5 TO STUD WALL DETAIL
<br />5CALE: N.T.5.
<br />WHERE CEMENT PLASTER (5TUCCO)15 TO BE APPLIED TO LATH OVER FRAME CONSTRUCTION, MEA5URE5
<br />5HALL BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PL45TER AND THE WATER RE515TIVE
<br />BARRIER A BOND BREAKER 5HALL BE PROVIDED BETWEEN THE WATER RE515TIVE BARRIER AND THE
<br />CEMENT PLASTER (5TUCCO) CON515TING OF ONE OF THE FOLLOWING: I. TWO LAYER5 OF AN APPROVED
<br />WATER RE515TANT BARRIER MATERIAL, OR 2. ONE LAYER OF AN APPROVED WATER IRE515TANT BARRIER
<br />OVER AN APPROVED PLASTIC HOUSE WRAP, OR 3. OTHER APPROVED METHODS OR MATERIAL5
<br />APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S IN5TALLATION IN5TRUCTIONS.
<br />5HEATHING BOARD - NOTE: 1/8" (3mm)
<br />GAP BETWEEN 5HEET5 OF PLYWOOD
<br />AND 055 AT VERTICAL AND
<br />HORIZONTAL JOINTS.
<br />WATER RE515TANT BARRIER - 2
<br />LAYERS (5EE NOTES ABOVE FOR
<br />LAYERING OPTIONS)
<br />5ELF-FURRING LATH
<br />LATH NAILED / 5TAPLED TO FRAMING
<br />MEMBERS MAX. 5PACING 6" O.C.
<br />CEMENT PLASTER BASE COAT
<br />(SCRATCH t BROWN)
<br />STUCCO TRADITIONAL
<br />(STUCCO)
<br />TWO COAT SYSTEM
<br />,
<br />FIN15H COAT
<br />(CEMENT PLASTER)
<br />MASONRY WALL STRIKE AND CUT TO A
<br />TEXTURE COAT
<br />LINE MIN. I" OR 2" MAX.
<br />BELOW 5LAB SEAT
<br />RMINATION ON C.M.U. AT FOUNDATION
<br />7
<br />11
<br />BEWS
<br />DESIGN GROVP
<br />150 STATE STREET EAST
<br />OLDSMAIt, FLORmA 346T7
<br />813 - 92.5 . 1300 TPL
<br />813 . 92S . 1800 FAX
<br />W W W.DAV4SBEW5.COM
<br />TAMPA • DEI�I�/F.R.
<br />EST. 1994 �
<br />O
<br />Z ON
<br />�o
<br />>U'SM0
<br />j rB U)
<br />tn
<br />N O lI
<br />ZQ u-
<br />Q V Q�
<br />z���
<br />w w0
<br />J O
<br />d'
<br />o�
<br />3>
<br />w�
<br />za
<br />z�
<br />�a
<br />w ¢ a
<br />� oQgo
<br />J<
<br />I-� j Z Z
<br />Q r 2 p �
<br />UO W w N
<br />w �Wo
<br />ON
<br />Q zz
<br />}o
<br />ZW
<br />z
<br />Z a
<br />O Q <
<br />W
<br />u- 0
<br />uj
<br />Q z Q o w
<br />Z
<br />Lu
<br />Z U Z zO
<br />OU
<br />Lu Z F
<br />O
<br />z ¢ u
<br />m z w �
<br />13- w l~O 00
<br />SCALE : AS NOTED
<br />DATE : 10-19-2018
<br />VERSION NO.
<br />imo
<br />SHEET NO.
<br />DAVISDT3
<br />��I li 111 llb �llit6i. :in c I ' IILI �.Im,iIIY