My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6416 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6416 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:48:28 AM
Creation date
2/19/2025 2:07:48 PM
Metadata
Fields
Template:
Building Plans
Street #
6416
Location
Cobble Bliss St
Contractor
Lennar Home
Building Plans - Permit #
21544
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEMPORARY TAPE <br />'FLAP' TO NoLD FLAP <br />HOUSE <br />WRAP/7 <br />ZIP <br />Ar ING <br />9' <br />ROUGH <br />OPENING <br />HOUSE <br />WRAP <br />SHEATHING <br />—TEMPORARY TAPE <br />'FLAP' TO HOLD FLAP <br />HOUSE <br />WRAP 7 <br />SHEATHING <br />ROUGH <br />OPENING <br />4' <br />SILL WRAP SILL FLASHING <br />HOUSE <br />WRAP INSTALL FLEXIBLE <br />FLASHING <br />SHEATHING CORNERS AT <br />WINDOW SILL <br />WINDOW FLASHING METHOD 'A -I' WINDOW FLASHING METHOD 'A -I' <br />A A WINDOW INSTALLER WILL CUT THE BUILDING PAPER AT A 45- ANGLE TO A POINT 9' UP AND 9' OUT 3-6TEP PROCESS: <br />0FROM THE UPPER CORNERS OF THE ROUGH OPENING. OO A INSTALL SILL FLASHING (EXTENDING 4' BEYOND THE ROUGH OPENING ON EACH SIDE) <br />B. INSTALL CORNER SHIELD FLASHING (FASTEN WITH M015TOP SEALANT OR EQUAL) <br />B. THIS WILL MAKE A 'FLAP' THAT WILL BE USED TO COVER THE HEAD FLASHING IN STEP 6. C. INSTALL SILL WRAP (MUST COMPLETELY COVER ROUGH OPENING SILL (INCLUDING CORNER SHIELDS) <br />METAL FLASHING <br />DOUBLE LAYER SPLINE APPLIED <br />VERTICALLY (IF USING FELT, SPLIT <br />36' - WIDE SHEET IN HALF) <br />2' TO 4' LAP AT <br />HORIZONTAL JOINT <br />i� <br />2' TO 4' LAP AT <br />� I <br />HORIZONTAL JOINT <br />I <br />I I i i <br />I I 1 I <br />I I <br />i l <br />I I I <br />SHEATHING <br />I I i i <br />I I <br />i l <br />I I <br />I I i I <br />i 1 I <br />I 1 <br />-' BUILDING PAPER <br />' <br />HOUSEWRAP <br />I I <br />I I <br />I I <br />I I <br />I I <br />I -CUT I I <br />WINDOW I <br />�IING5 �c <br />EN <br />VI I I <br />SHEATHING WRAP <br />(BUILDING PAPER <br />OR HOUSEWRAP) <br />I <br />CARRIED I' TO 2' <br />BELOW BOTTOM <br />OF SHEATHING <br />4' TO 6' LAP AT <br />VERTICAL JOINT <br />9' (6' MINA BEYOND <br />CORNER BOARD <br />SHEATHING <br />WRAP DETAIL <br />SCALE: N.T.S, <br />'FLAP' <br />WINDOW FLANGE <br />WRAP <br />vzz,4111A <br />TEMPORARY TAPE <br />TO HOLD FLAP <br />HOUSE <br />WRAP <br />\—SHEATHING <br />CAULK BEHIND <br />WINDOW FLANGE <br />BEFORE <br />INSTALLATION. <br />SILL FLASHING <br />WINDOW FLASHING METHOD 'A -I' <br />03 A APPLY A CONTINUOUS BEAD OF CAULKING ON THE BACK SIDE OF THE WINDOW FLANGE. <br />B. INSTALL THE WINDOW ACCORDING TO THE MANUFACTURERS SPECIFICATIONS. <br />TEMPORARY TAPE <br />'FLAP' TO HOLD FLAP <br />HOUSE <br />WRAPP 7 <br />FLASHING <br />JAM FLASHING <br />WINDOW FLANGE <br />HOUSE <br />WRAP <br />_.._ ._....._ SILL FLASHING <br />WINDOW FLASHING METHOD 'A -I' <br />OA INSTALL HEAD FLASHING OVER THE WINDOW FLANGE, <br />B. EXTEND THE HEAD FLASHING V BEYOND THE ROUGH OPENING ON EACH SIDE. <br />TO ALLOW MOISTURE TO BE DIVERTED TO THE OUTSIDE SURFACE <br />-TEMPORARY TAPE <br />RFLAP ' TO HOLD FLAP <br />41 // <br />HOUSE <br />\ % WT�7 <br />SHEATHING <br />JAM FLASHING <br />WINDOW FLANGE <br />to <br />HOUSE <br />WRAP <br />SILL FLASHING <br />SHEATHING <br />WINDOW FLASHING METHOD 'A -I' <br />OA INSTALL JAMB FLASHING OVER THE WINDOW FLANGE ON EACH SIDE. <br />B. EXTEND THE JAMB FLASHING 4' ABOVE THE ROUGH OPENING AND 8' BELOW THE ROUGH OPENING. <br />C. INSTALL THE WINDOW ACCORDING TO THE MANUFACTURERS SPECIFICATIONS. <br />HOUSE <br />WRAP <br />HOUSE <br />WRAP 7 <br />'FLAP'7% ----- \ - i <br />----------------------------- 7 <br />AD FLASHING <br />L\— SILL FLASHING <br />WINDOW FLANGE <br />WINDOW FLASHING METHOD 'A -I' <br />OA ALLOW THE BUILDING PAPER 'FLAP' TO DRAPE OVER THE HEAD FLASHING. <br />'FLAP' <br />WEATHER RESISTANT - <br />CONSTRUCTION TAPE <br />HOUSE <br />WRAP <br />SILL PLAS14NG <br />SHEATHING WINDOW FLANGE <br />JAM FLASHING <br />FLASHING <br />JAM FLASHING <br />WINDOW FLASHING METHOD 'A -I' <br />OA APPLY WEATHER RESISTANT TAPE OVER THE 45. ANGLE CUT ON THE BUILDING PAPER <br />B. ON INSIDE PERIMETER OF WINDOW APPLY CONTINUOUS BEAD OF SEALANT OR EXPANDABLE FOAM <br />Fi1X:F.u:<':.1s1:r 3:i^r.,'?F'�ta a s `a:s'•:";::;d <br />r)s Via:).. 333A:<.>.a3<" • 3.3r' y. :..,. <br />11111, 11 <br />`FFtI'K F <br />s' . <br />a:`<i33f:i3i33"i:.a„f xssai� H ,<i tR^''r'aa:..;s:. <br />.;t.,.'>;.;z¢is%� i%'S1%s�,,.''is's `, rw':as2r �'•''s, �;;;i;s:s <br />tsf "! <br />yl <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineenng.com <br />CA 25948 <br />o <br />0 <br />N <br />Z w <br />Ln <br />o 0 <br />z <br />_ <br />0(nMr, <br />a`�L-i <br />W LL <br />LNn <br />z <br />00 <br />zZ 17) <br />W <br />Z� <br />w <br />J <br />0 <br />CD <br />x F— <br />w w <br />H <br />Lu = F_ <br />a- <br />LU V) <br />_ 25 <br />tV) <br />Q 1 W <br />V) Lu <br />Q O °° <br />Ill <br />O <br />z `O <br />0 <br />110 <br />CL <br />V) <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />02019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />©2019 - THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 <br />1.02 ROOF UNDERLAYMENT REV. <br />02.11.19 <br />1.03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSIQ,N 1 Oi ' 1`.031:02.1 1.19 <br />LJ ` ' r. <br />41 <br />c� <br />c�j <br />fr') <br />De <br />o <br />Lu <br />z O <br />w <br />Q one = U <br />W C� >N 3 <br />V)Q� =N _N <br />W w� _10 }00 <br />W <br />�* �* w* <br />Z =Lui Nu; <br />Qu; fie <br />W ❑ � ❑ <br />SHEET TITLE: <br />WINDOW FLASHING <br />DETAILS & NOTES <br />SHEET INFORMATION: <br />JOB NO.: 390442 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />WF-1 <br />00 <br />0 <br />CN <br />LO <br />r— <br />
The URL can be used to link to this page
Your browser does not support the video tag.