My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6429 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6429 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 5:31:07 PM
Creation date
2/19/2025 2:08:35 PM
Metadata
Fields
Template:
Building Plans
Street #
6429
Location
Ten Acre Ct
Contractor
Lennar Home
Building Plans - Permit #
5280
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />u <br />ROOF FRAMING PLAN (ELEV B. <br />1 /411 = 1'-091 <br />6'-0" 6'-11" <br />0 <br />TRUSS NOTES: <br />THE FLOOR AND ROOF TRUSS LAYOUT ON THESE PLANS <br />ARE SCHEMATIC DESIGN ONLY. FINAL FLOOR AND ROOF <br />TRUSS LAYOUTS TO BE DEVELOPED BY TRUSS <br />MANUFACTURER. TRUSS LAYOUTS AND TRUSS SHOP <br />DRAWINGS MUST BE REVIEWED AND APPROVED BY <br />DESIGN STYLES, INC. AND/ OR THE ENGINEER OF RECORD <br />PRIOR TO CONSTRUCTION. <br />TRUSS MANUFACTURER TO VERIFY ADEQUACY OF ALL <br />SPECIFIED LVL BEAMS AND MAKE ANY ADJUSTMENTS <br />NECESSARY DUE TO FINAL TRUSS DESIGN OR <br />CALCULATED REACTIONS. ALL MODIFICATION TO BE <br />REPORTED TO DESIGN STYLES, INC. AND THE ENGINEER <br />OF RECORD PRIOR TO CONSTRUCTION. <br />ELECTRICAL & HVAC LAYOUTS ARE BASED ON THESE <br />FRAMING LAYOUTS. ANY DEVIATIONS ARE TO BE <br />APPROVED BY DESIGN STYLES, INC. PRIOR TO <br />CONSTRUCTION. <br />TYPICAL TRUSS CONNECTORS <br />1. ALL CONNECTORS ARE "SIMPSON, STRONG -TIE". U.N.O. <br />2. USE MTS20'S OR H10A'S FOR ROOF TRUSS TO FRAME <br />CONNECTIONS. <br />3. ATTACH ALL FRAMING ABOVE ROOF TRUSSES TO <br />TRUSSES W/ MTS16'S. <br />4. USE HETA20 FOR ROOF TRUSS TO MASONRY <br />CONNECTIONS. <br />5. USE (2) HETA20 FOR GIRDER TRUSS TO MASONRY <br />CONNECTIONS. <br />6. USE (2) HTS30 OR H10A FOR GIRDER TRUSS TO FRAME <br />CONNECTIONS. <br />7. THE PREVIOUS CONNECTORS APPLY UNLESS <br />OTHERWISE NOTED. <br />8. SEE FLOOR PLAN AND FOUNDATION SHEETS FOR <br />OTHER CONNECTIONS. <br />DESIGN STYLES, INC. AND THE ENGINEER RESERVE THE <br />RIGHT TO MAKE ANY CHANGES AFTER FINAL TRUSS <br />INFORMATION IS SUPPLIED FROM TRUSS MANUFACTURER. <br />NOTE: <br />ALL VALLEY KITS MARKED "VK" OR "MVK" ARE <br />CONVENTIONALLY FRAMED. PLEASE REFER TO <br />ENGINEERING PACK FOR DETAILS <br />NOTES: <br />• FLOOR TRUSSES ARE CUTBACK 3/4" FROM EXTERIOR BLOCK <br />WALLS. <br />• FLOOR TRUSSES ARE CUT BACK 1/2" FROM FRAME WALLS. <br />• SEE ENGINEERING FOR FLOOR TRUSS CHASE AND STRONG <br />BACK LOCATIONS. <br />• SECOND STORY TRUSSES ARE CUTBACK 3/4" FROM EXTERIOR <br />WALLS. <br />NOTE: <br />DO NOT CUT OR ALTER TRUSSES WITHOUT CONSENT OF THIS <br />OFFICE. BACK CHARGES WILL NOT BE ACCEPTED WITHOUT PRIOR <br />WRITTEN APPROVAL BY OUR SERVICE DEPARTMENT AT <br />CARPENTER CONTRACTORS OF AMERICA, INC. 877-293-9487 <br />NOTE: <br />MULTI -PLY GIRDER CONNECTION. <br />ALL PLIES SHALL BE FASTENED TOGETHER BOLTS, NAILS, AND <br />OR SCREWS) PRIOR TO INSTALLATION AND BEFORE ANY LOADS <br />ARE APPLIED. PER THE SUPPLIED ENGINEERING SHEETS. <br />NOTE: <br />ALL BEARING WALLS MUST BE ADEQUATELY DESIGNED TO CARRY <br />THE LOADS IMPOSED BY THE TRUSS OR TRUSSES, AND MUST BE <br />IN PLACE AND IN SERVICE BEFORE THE TRUSSES ARE SET IN <br />ORDER TO AVOID REPAIRS. <br />COLUMN NOTE: <br />REFER TO FOUNDATION PLAN FOR COLUMN SIZES <br />AUG 2 n Z64Z <br />VV\ <br />VIRTUAL REVIEW ASSIS' <br />Virtual Review Ass <br />Plans Review colr , i,- c' d appi-co-,,ed <br />for compliance with t.-,4_ t=BC 7th <br />Edition by Debra Anlle Klahr PX2300 <br />HEEL= 4-1/16" <br />PLUMB <br />CUT/ <br />12" <br />5.9 F 12 <br />12 <br />Z�lk IF. <br />2X4 <br />LABELED END MARK <br />REFER TO ENG. <br />PACK FOR <br />TYPICAL 5' SETBACK CORNER -SET <br />LABELING AND SPACING <br />REFER TO ENG. <br />PACK FOR CONNECTION <br />CJ5 <br />CJ3 <br />U <br />CJ11 <br />U <br />U <br />1'-0 5/16" 1.2'-0" I, 2'-0" <br />TYPICAL T SETBACK CORNER -SET <br />LABELING AND SPACING <br />ATTENTION! <br />DON'T LIFT SINGLE TRUSSES <br />VATH SPANS LONGER THAN <br />30' BY THE PEAK <br />CONSULT BCSI -B1 <br />NY Span or less 30 to 60' <br />ade <br />/ 80 degrees Sp <br />re <br />1 or less <br />1 112 I 2/3 to t/2 1 <br />line F span approx. Ta Gne span approx. <br />REFER TO BCSI -131 <br />Truss must be set this way if crane used. <br />Truss is an example, your truss may not match. <br />Insist crane operator sets truss this way. <br />General Notes <br />1. ALL PARALLEL CHORD TRUSSES, FLAT TRUSSES <br />AND FLAT GIRDERS HAVE THE TOP CHORD <br />PARTIALLY PAINTED GREEN TO BE INSTALLED <br />GREEN SIDE UP. <br />2. ALL HANGERS TO BE SIMPSON HUS26 UNLESS <br />OTHERWISE NOTED. <br />3. ALL TRUSS SPACING IS 24" O.C. UNLESS <br />OTHERWISE NOTED. <br />4. PER TRUSS PLATE INSTITUTE BCSI-B1 <br />RECOMMENDATION PERMANENT X-BRACING <br />SHOULD BE PLACED AT A MAXIMUM SPACING 15' <br />O.C. ACROSS THE SPAN, TO BE REPEATED AT A <br />MAXIMUM OF 20' BETWEEN EACH X-BRACE <br />THROUGHOUT THE STRUCTURE. <br />* PLEASE REFER TO BCSI-131 FOR ANY ADDITIONAL <br />BRACING DETAILS. <br />ROOF LOADING <br />SCHEDUL <br />TCLL = <br />20 <br />PSF <br />TCDL = <br />7 <br />PSF <br />BCLL = <br />* <br />PSF <br />BCDL = <br />10 <br />PSF <br />TOTAL = <br />37 <br />PSF <br />DURATION = <br />1.25 <br />WIND SPD/TYPE= 145 <br />ENCLOSED <br />BLDG EXPOSURE = C <br />USAGE = RESIDENTIAL <br />CAT <br />II <br />WIND IMPORTANCE FACTOR = <br />1 <br />UPLIFTS BASED ON= 9.2 <br />PSF <br />DESIGN CRITERIA <br />FBC 2020 <br />TPI 2014 <br />Truss member design & connector plates <br />are designed for ASCE 7-16 and maximum <br />forces from both components and claddings <br />and main wind force resisting systems. <br />* These trusses have been reviewed to carry an <br />additional 10# psf non -concurrent bottom chord live <br />load. <br />FLOOR LOADING SCHEDUL <br />TCLL = 40 PSF <br />TCDL = 10 PSF <br />BCDL = 5 PSF <br />TOTAL = 55 PSF <br />ROOF DESIGNED FOR <br />SHINGLE <br />ALL REACTIONS <br />AND UPLIFTS <br />ARE SHOWN ON ENGINEERING. <br />WALL KEY <br />09 <br />DESCRIPTION INIT. DATE <br />Created from BID 6312288A AS <br />8/62015 <br />REV. ENTRY & ADD HIP @ REAR SHM <br />9/18115 <br />KR <br />Add Vaulted ceiling in Great nn, <br />nin then Fo AS <br />12/29/2015LC9 <br />AND FBC2017 HAB <br />12/07/2017RE-CALC <br />A7G B.C. AS <br />7/23/2019LCA <br />JTH <br />1/4/21 <br />LOAD# DESCRIPTION INIT. DATE N <br />alts I revision blodc for alts only. <br />CARPENTER <br />CONTRACTORS <br />J OF AMERICA <br />3900 AVENUE G, N. W, <br />WINTER HAVEN FLORIDA 33880 <br />PH❑NE: (800) 959-8806 <br />FAX: (863) 294-2488 <br />BUILDER : LENNAR HOMES <br />PROJECT: <br />MODEL : 1450 <br />CCA PROJ/MODEL/ALT <br />7A2 / 1450B 1325 <br />ALT DESC <br />OTC : <br />LOT 1331 BLOCK 40 <br />DESIGNER I PAGE <br />DATE 1 <br />8 O6 2 )15 1 <br />LAN �321594L <br />SCALE <br />1 4 "=1 ' <br />C` <br />N <br />N <br />N <br />- rFL <br />LID <br />OD <br />LO <br />mod- �• <br />0 <br />w <br />0 <br />za <br />^N N LO ; E <br />�M <br />_W L U <br />�MN N <br />— } In M <br />in �° ! M <br />C E =o <br />28 <br />O LLo Q <br />� U � a� a <br />_ Ci � <br />�L1' LU a; <br />TN L o En <br />a @ <br />C7 W <br />0 LLI C/j W O H <br />1Yz2J<0QW<,UO JO <br />Q0<dXJ(oZmooH— <br />,0 <br />OzzQL)1. ,96WM� <br />fZ <br />WA Y Jjj <br />wOwZQ�gz (o <br />LL <br />U)QwOW 0<o <br />LL <br />IR <br />0 <br />z N <br />OW <br />z <br />M O <br />Q M LO <br />_j <br />U) L1 ^ P <br />z <br />< W Li') <br />F-- W a (Y) <br />ao <br />Q Q <br />Z U <br />WQ <br />W <br />J C) <br />I <br />I <br />i <br />I <br />I <br />i <br />I <br />I <br />O <br />N <br />N <br />N <br />N <br />O <br />N <br />O <br />N <br />M <br />o <br />N <br />in <br />`p <br />Z <br />0 <br />N <br />U) <br />W <br />o <br />O <br />O <br />Lo <br />�l , <br />L <br />> <br />.— <br />N <br />ri <br />I <br />00 �^ <br />Z� <br />VJ <br />Qz <br />w <br />O <br />0)O <br />w_ <br />Woo <br />U <br />U U <br />pW_5; <br />H 0 <br />Z <br />aixIa <br />r- Q <br />= <br />w=Q <br />mg-W <br />0�0 <br />�0v <br />w <br />N <br />0 <br />�3:2 <br />Z0fo <br />Z <br />U <br />gZLL <br />. <br />o_ z <br />U <br />3C <br />Q <br />F- <br />U <br />_j <br />O <br />_p <br />W <br />z <br />z <br />z <br />z <br />w <br />WC) <br />04 <br />0 <br />LAST PLOT DATE <br />• <br />July 15, 2022 <br />Z <br />J <br />ROOF FRAMING <br />PLANS B <br />
The URL can be used to link to this page
Your browser does not support the video tag.