Laserfiche WebLink
1 REFER TO GENERAL NOTE H. 7"x7" (1,500 FPM VELOCITY) WELDED BLACK STEEL <br />DUCTWORK FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. SEE <br />DETAIL F ON SHEET M2.0. <br />2. EXHAUST HOODS SHALL BE INSTALLED & SUPPORTED PER MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />FRYER EXHAUST HOOD IS LISTED UNDER UL FILE NUMBERMH18450. THE FILE <br />DESCRIBES THE ALTERNATE CLEARANCE METHOD AND MATIMrSMUSED ON THE <br />EXHAUST HOOD AS DETAILED IN NFPA 96. THE HOOD IS PROVIDED WITH 3" <br />INSULATED REAR AIRSPACE. <br />4. CONTRACTOR SHALL FURNISH AND INSTALL 24 GA. MIN. STAINLESS STEEL <br />BEHIND AND 18" OUTSIDE PERIMETER OF HOOD, ATTACHED TO WALL. <br />5. PROVIDE CLEAN OUT ACCESS DOORS AS INDICATED ON PLAN. CLEAN OUT <br />ACCESS DOOR TO BE 4"x7" OPEN AREA ON THE VERTICAL SIDE OF DUCT. <br />6. REBALANCE EXISTING UNIT'S ECONOMIZER/OUTSIDE AIR DAMPER TO VOLUME <br />INDICATED ON PLAN. <br />HVAC NOTES D <br />RIU <br />P <br />G <br />U <br />- <br />,IPE SLOPING DOWN <br />LWAY FROM SHROUD <br />IIN. 24 GA. G.I. PIPE <br />NCLOSURE COVER <br />- HEAD NAIL @ 6- O.C. <br />!CREW THRU NEOPRI <br />VASHER, 3 PER SIDE <br />2) 2x12 WD CURB OVER <br />;ECURED TO DECK <br />ASE FLASHING <br />MULTIPLE PIPE FLASHING 1 1/2" 11-0"1 E <br />MIN. 24 GA. G.I. CAP FLASHING <br />SECURE W/ SCREW THRU <br />STEELlNEOPRENE WASHER AS <br />NEEDED FOR PROPER <br />SECUREMENT (4 SIDES)-� <br />2X6 @ 16-0.c;-�� <br />z <br />NOTE: <br />SET SUPPORTS ON SOLID <br />NON -RIBBED NEOPRENE, AND <br />SECURE LAG BOLTS THROUGH <br />STEEL/NEOPRENE WASHER <br />518"CDX PLYWOOD <br />(2)2xl2, RIP FOR LEVEL <br />PLATFORM <br />BITUTHENE CAP SHEET <br />OVER TOP OF SLEEPER <br />EXTEND DOWN SIDES BY 2" <br />BASE FLASHING <br />FIBER CANT STRIP W/ 4" <br />LEGS - NNL TO PLYWOOD <br />0,T 12- O.C. <br />OOFING MATERIAL <br />20.- 20.- 2w <br />1 Od @ 6- O.C. CrypicAL) cR <br />2x6 BLOCKING 0 <br />>; <br />SLEEPER SUPPORT F <br />A. ALL WORK AND MATERIALS SHALL COMPLY WITH STATE AND LOCAL CODE <br />REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY, <br />INCLUDING APPLICABLE SECTIONS OF NFPA, UBC, OSHA, OR ANY INTERIM <br />AMENDMENTS AT THE TIME OF THE PROPOSAL. PURCHASE ALL PERMITS <br />ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. <br />B. CONTRACTORS AND SUB -CONTRACTORS SHALL CAREFULLY REVIEW THE <br />CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK <br />IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY <br />DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. <br />C. EXISTING CONDITIONS ARE BASED ON "AS -BUILT" DRAWINGS PROVIDED BY THE <br />OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO <br />ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. <br />CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. <br />D . ALL EQ U I P M ENT AN D AP P LIAN C ES S HALL BE I NSTALLED AS REQU I RED BY TH E <br />TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE CONDITIONS OF THE <br />LISTING, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE LOCAL <br />CODE. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON <br />THE JOB SITE AT THE TIME OF INSPECTION. <br />E. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO RECEIVE, OFF- LOAD, <br />STORE, INSURE, CARRY UP, DISPOSE OF DEBRIS AND SET IN PLACE ALL OWNER <br />FURNISHED ITEMS AND EQUIPMENT. <br />_*_�F. EXHAUST FANS SHALL BE LOCATED A MINIMUM OF 10'-0" HORIZONTAL DISTANCE <br />FROM FRESH AIR INTAKES OR SHALL HAVE A VERTICAL SEPARATION OF 3'-0" <br />ABOVE FRESH AIR INTAKES. <br />G. CONTRACTOR SHALL INSTALL THE FOLLOWING EQUIPMENT PROVIDED BY THE <br />OWNER: <br />'—l. EXHAUST HOOD WITH PRE -PIPED ANSUL SYSTEM, HANGER BRACKETS AND GAS <br />SOLENOID VALVE. <br />CONTRACTOR SHALL PROVIDE AND INSTALL COMMERCIAL KITCHEN GREASE <br />EXHAUST DUCTWORK THAT SHALL BE THE FOLLOWING TYPE: <br />16 GAUGE BLACK STEEL DUCTWORK, ALL JOINTS AND SEAMS SHALL BE WELDED <br />LIQUID TIGHT. ALL ELBOWS SHALL BE RADIUS AND THE DUCT SYSTEM SHALL BE <br />FABRICATED SO AS TO HAVE NO DIPS, TRAPS, OR POCKETS WHERE GREASE CAN <br />ACCUMULATE. PROVIDE APPROVED ACCESS PANELS FOR INSPECTION AND <br />CLEANING AT ALL CHANGES IN DIRECTION, AND TO GAIN ACCESS TO THE BYPASS <br />DAMPER AND FUSIBLE LINK WHERE APPLICABLE. INSULATE EXTERIOR OF DUCT <br />WITH INSULATION APPROVED BY LOCAL AUTHORITY TO REDUCE CLEARANCE TO <br />COMBUSTIBLES TO 0". PROVIDE FIRE RATED ACCESS PANELS IN THE DUCT <br />ENCLOSURE AT ALL DUCT ACCESS PANEL LOCATIONS. MAINTAIN 1/4" PER FOOT <br />SLOPE TOWARDS THE HOOD ON ALL HORIZONTAL GREASE DUCT. INSTALLATION <br />SHALL BE IN ACCORDANCE WITH NFPA 96. <br />1. CONTRACTOR SHALL PROVIDE DUCTWORK SUPPORTS AND HANGERS PER CODE. <br />PROVIDE THREADED ROD, WASHERS, AND NUTS FOR CONNECTION TO HOOD <br />HANGER BRACKETS. <br />J. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING PROPOSED <br />FABRICATION AND INSTALLATION COORDINATED WITH EXISTING FIELD <br />CONDITIONS AND OTHER TRADES. <br />K. CONTRACTOR SHALL ENSURE EXISTING HVAC UNITS ARE INTERLOCKED WITH NEW <br />FRYER EXHAUST FAN FOR CONTINUOUS OPERATION WHEN EITHER UNIT OR FAN IS <br />RUNNING. <br />GENERAL NOTES <br />C <br />THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL <br />CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE <br />VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR THE EQUIPMENT <br />ROUGH -IN DRAWINGS. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY <br />MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS <br />SHOWN ON THE PLAN. THEREFORE, THE ARCH ITECT/ENGI NEER SHALL BE <br />IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION OF ANY DEVIATIONS FROM <br />WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE <br />APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL <br />PACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR <br />ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR. <br />MECHANICAL PLAN 1/4"=V-0" <br />�j NEW ROOF MOUNTED NEW FRYER EXHAUST FAN TO BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR ON FLAT ROOF. 510 <br />CFM AT 1500 FPM. PROVIDE CURB EXTENSION SO TOP OF EXHAUST FAN IS LEVEL WITH EXISTING R90FTOP UNIT. VERIFY IN FIELD. <br />0,y"�ao L-keve� C-�ap <br />2 HINGED ACCESS PANEL FOR NEW FRYER EXHAUST FAN, SHOWN FOR REFERENCE. <br />CONTRACTOR AND YUM CONSTRUCTION MANAGER SHALL COORDINATE LOCATION OF NEW FRYER EXHAUST FAN TO MAINTAIN A <br />MINIMUM OF 10'-0" FROM ANY FRESH AIR INTAKE. <br />NEW TYPE I EXHAUST HOOD - PART OF WINGSTREET PACKAGE #WSIB3-36-FLAT.K3. SEE DETAILS ON DRAWING SHEET M2.0 AND M3.0. <br />G.C. TO PROVIDE AND INSTALL 24 GA. STAINLESS STEEL BEHIND HOOD AND 18" OUTSIDE OF PERIMETER OF HOOD FOR CONSISTENCY <br />AND CLEANABILITY. <br />CONTRACTOR TO LOCATE NEW ANSUL PULL STATION FOR NEW FRYER HOOD AT LEAST 10'-0" TO 20'-0" AWAY FROM FRYER HOOD. <br />T'x7" EXHAUST DUCT WITH WELDED SEAMS UP FROM EXHAUST RISER ON HOOD TO EXHAUST FAN EF-4 ROOF. PROVIDE A DUCT <br />ENCLOSURE FOR THE GREASE DUCT ABOVE CEILING PENETRATION TO THE OUTSIDE OF BUILDING. A ONE -HOUR ENCLOSURE IS <br />REQUIRED IN ALL BUILDING AND A TWO-HOUR RATED ENCLOSURE ON TYPE 1 OR 2 FIRE RESISTIVE BUILDINGS (AS PER 2004 FLORIDA <br />MECHANICAL CODE 507.9). REFER TO GREASE EXHAUST DUCT DETAIL ON DWG. M2.0 FOR ADDITIONAL INFORMATION. <br />16 GAUGE BLACK STEEL DUCT WITH LIQUID TIGHT CONTINUOUS EXTERNAL WELD. PROVIDE CLEAN -OUT ACCESS. WRAP WITH ONE (1) <br />LAYER OF 3M FIRE BARRIER DUCT WRAP 15A, 1-1/2" THICK WITH 3" PERIMETER AND LONGITUDINAL OVERLAPS. PROVIDE ONE OR TWO <br />HOUR FIRE RESISTIVE RATING AND ZERO CLEARANCE TO COMBUSTIBLES AT OVERLAP OR COLLAR. 3M FIRE BARRIER DUCT WRAP IS <br />LISTED BY OMEGA POINT LAB DESIGN NUMBER GD532F AND Ul. #1978. INSTALL PER MANUFACTURER'S INSTRUCTIONS. REFER TO <br />GREASE EXHAUST DUCT DETAIL ON DWG. M2.0 FOR ADDITIONAL INFORMATION. <br />CONTRACTOR SHALL REMOVE EXISTING SUPPLY AIR DIFFUSER AND REPLACE WITH A TITUS MODEL #8FF OR METAL-AIRE MODEL #7650 <br />PERFORATED DISCHARGE PANEL DIFFUSER WITH A HINGED FACE AND NO FILTER. FIELD VERIFY LOCATION. LOCATE A MINIMUM OF 6.4, <br />AWAY FROM NEW FRYER HOOD. COORDINATE EXACT LOCATION WITH CEILING GRID & LIGHT FIXTURES. MODIFY S.A. DUCT AS <br />REQUIRED. INSTALL PER MANUFACTURERS INSTRUCTIONS. <br />(-1-0-) CONTRACTOR SHALL VERIFY EXISTING THERMOSTAT QUANTITY AND LOCATIONS. REWIRE AS PART OF MAKEUP AIR INTERLOCK. <br />COORDINATE WITH ELECTRICAL CONTRACTOR. - SEE DETAIL 2 ON SHEET E1.0 FOR TYPICAL WIRING DIAGRAM. <br />_11-) NEW CONDENSING UNIT TO BE LOCATED AT SITE OF EXISTING CONDENSING UNIT FOR EXISTING STAND-ALONE ICE MACHINE TO BE <br />REMOVED. PROVIDE NEW REFRIGERANT PIPING AS REQUIRED DUE TO NEW ICE MACHINE INSTALLATION. ROUTE NEW PIPING TO <br />OPENING IN ROOF. VERIFY EXISTING ROOF CONDITIONS (CRICKETS, FANS, ROOFTOP UNITS) AND ADJUST PIPE ROUTING AS REQUIRED. <br />INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. REFER TO MULTIPLE PIPE FLASHING DETAIL, E/M1.0 AND SLEEPER SUPPORT <br />DETAIL, F/M1.0 FOR INFORMATION <br />CONTRACTOR SHALL VERIFY IN FIELD LOCATION OF EXISTING ROOFTOP EQUIPMENT (SATELITES, ROOFTOP UNIT, ETC.) AND ADJUST <br />NEW FRYER EXHAUST FAN LOCATION AS PER ACTUAL SITE CONDITIONS. <br />CD EXISTING ROOF PARAPET SHOWN FOR REFERENCE. <br />� 6 <br />o� <br />w <br />a4 <br />KEY NOTES <br />J <br />a <br />0 <br />0 <br />c) LL <br />a: <br />w <br />UJ 1� <br />M X: <br />U. <br />04.24.08 HAND SINK ADDITION <br />CONTRACT DATE: 03.21.08 <br />BUILDING TYPE: ???7.??' <br />STORE NUMBER: 95343 <br />ARCV NUMBER: 080406 <br />6548 GALL BLVD. <br />ZEPHYRHILLS, FIL 33542 <br />HVAC PLAN & <br />SPECS. <br />m 1 0 <br />PLOT DATE: <br />02.19.08 <br />14� <br />�\)'Nmuv_ UN <br />