General Notes <br />1. Structure suitable when empty for ground water not higher than 6" above main drain. <br />2. Permanent Tile depth markers, minimum 4" high with contrasting color, slip resistant flush on <br />deck or top of beam not more than 2 feet from water edge and inside back of gutter (glaze <br />minimum 4" high. <br />3. Permanent Red International NO DIVE Tiles, non -slip flush minimum 4" high, on top of the <br />deck not more than 2 feet from water edge every 25 feet of perimeter maximum see detail. <br />4. All equipment shall have NSF, UL, or appropriate approval. <br />5. All electrical, grounding, wiring & bonding to comply with Florida building code <br />FBC 2020, 7th Edition, Chapter 27, NEC 2017, Section 680 and 680.26(C). <br />No overhead power within 10 feet. <br />Electrician must certify compliance to engineer. NEC 680.26(C) requires that all parts <br />specified in 680.26(B) shall be connected to an equipotential bonding grid with solid copper <br />conductor, insulated, covered. or bare, not smaller than 8 AING or rigid metal conduit of brass <br />or other identified corrosion -resistant metal conduit. Connection shall be made by exothermic <br />welding or by listed pressure connectors suitable for the purpose and are of stainless steel, <br />brass, copper, or copper alloy. <br />6. Pool make-up water is from an approved source with air gap. <br />7. No direct connections between water and sanitary systems, minimum 3" gap. <br />8. Vacuum breakers on all hose bibs in pool area. <br />9. Minimum 7'vertical clearance above deck and pool water <br />10. No food or drink services to be within 12 feet of inner edge pool deck. <br />11. Walkways between pool and sanitary facilities shall be impervious, slip resistant for the first <br />15 feet from pool water edge. <br />12. If night swimming is allowed, overhead lighting shall provide at least 3 foot candles of <br />illuminations at the water and wet deck level. <br />13. Overhead illumination of 30 foot candles at floor level in equipment room. <br />14. Owner to provide storage of chemicals under roof, protected from access by unauthorized <br />persons. <br />15. Owner to provide traffic barriers at deck if needed. <br />16. Main drain(s) to meet ANSI/APSP 16 NSF50, 64E-9 and comply with Virginia <br />Graeme Baker Act. <br />17. Feeders to be interlocked with recirculation pump. <br />18. Pipe: PVC schedule 40 NSFpw <br />19. Gauges: 2" minimum; 0-60 psi. <br />20. Test Kit: Taylor 2006 or Equal; Taylor K-1766 Sodium Chloride Testking Kit <br />where applicable <br />21. All electric and ground to meet NEC or local code. <br />22. The equipment area or collector tank or chemical containers shall not be accessible to <br />unauthorized individuals. <br />23. Install new equipment and plumbing per manufacturers instructions. <br />24. Plastic pipe subject to a period of prolonged sunlight exposure must be coated to protect it <br />from ultraviolet light degradation <br />25. ALL EQUIPMENT MUST BE LABELED AND EASILY READ, THIS INCLUDES THE <br />FLOWMETER. <br />26. All equipment (pumps, motors, pressure gauges, valves, auto and manual fills, piping, filters, <br />flow indicators and flow meters ) must be operating properly before calling this <br />office and/or the Health Department for inspection. <br />27. Lighting certification is not part of this submittal. Contact a Lighting or Electrical engineer for <br />certification. <br />28. Direct access to equipment is required. <br />29. The equipment enclosure, area or room floor shall be of concrete or other nonabsorbent <br />material having a smooth slip -resistant finish and shall have positive drainage, including a <br />sump pump if necessary. <br />30. Equipment rooms shall either forced draft or cross ventilation. <br />31. Pool and Bathhouse electrical outlets to be GFCI with trip points 6mA or less with cover. <br />32. Pool chemicals to be stored away from other materials in a cool, dry , ventilated area with <br />restricted access. <br />33. Only NSF-60 approved chemicals shall be provided <br />34. Pool to have Shepherd's Hook, Straight Pole, Ring Buoy for safety equipment. <br />35. The deck must not have pits and crevices more than 3" deep. <br />16 <br />36. A flow meter shall be provided with properly located and proper clearances upstream and <br />down stream. <br />37. A gate to the equipment area must be provide within 10' of the equipment area. <br />38. The equipment room area must provide clearances for all equipment as prescribed by the <br />manufacturer to allow normal maintenance and removal. <br />39. All equipment meets NSF/ANSI Standards 50-2007. <br />40, Recirculation pump must have a hair and lint strainer. <br />41. All exposed PVC piping will be painted for UV protection. <br />42. The plans meet FBC 2020, 7th Edition, Section 454.1. <br />43. The plans meet 2017 National Electric Code <br />44. All depth markers are to indicate actual depths within 3". <br />45. Horizontal tile used in less than 5' (1524 mm) of water must be slip resistant. <br />Fence <br />Florida Building Code requires that all public pools shall be surrounded by a minimum 48" high <br />fence. The fence shall be continuous around the perimeter of the pool area that is not otherwise <br />blocked or obstructed by adjacent buildings or structures and shall adjoin with itself or abut to the <br />adjacent members. Access through the barrier other than from doored exits of adjacent <br />building(s) shall be through self -closing, self -latching, lockable gates of 48" minimum height with <br />the latch located a minimum of 54" from the bottom of the gate or at least 3" below the top of the <br />gate on pool side. Gates shall open outward away from the pool area. <br />Pool Information <br />Area: 5,455 Square Feet <br />Perimeter: 547 Linear Feet <br />Capacity: 134,300 Gallons <br />Design Flow Rate: 515 GPM <br />Turnover: 4.3 Hours <br />Unit Count: 715 Non -Transient <br />Max. Depth: 5-0" <br />Min. Depth: 0'-0" (Zero -Entry) <br />Bather Load: 103 Persons <br />Vacuum System: Recreonics portable vacuum pump with filter. <br />Valves: Proportional flow, ball globe, or butterfly for return line, main drain, gutter and <br />heater by-pass or approved equal, otherwise gate.Feeders to be wired with failure proof <br />interlock with the recirculation pump. <br />Pipe: PVC Schedule 40 NSFpw <br />Level (Static) Line Grate: S P 10 19 <br />Gutter: Pentair 2.5" x 6" <br />Main Drain: [2] 12"xl 2" VGB Compliant <br />Anchors: Hayward SP 1392 <br />[1 ] 18"xl 8" VGB Compliant <br />Transformers: Area Lighting LG-300/12 Volt <br />Inlets: Hayward SP 1425 <br />Leaf Skimmer: Lion 10 10 <br />Escutcheons: Frost 41661 <br />Vacuum Head: Rainbow 214 <br />Lights: Pentair 5G Intellibrite, RGB Color <br />Brush: A&B 3004 <br />Changing <br />Vacuum Hose: Plastiflex <br />NEC 2017, Section 680.26 <br />Shell: Concrete, 4,000 P.S.I., 28 Day, <br />Florida Building Code 2017 Chapter 27 <br />Rigid Construction #4 Rebar <br />Life Ring: (2) 24" W/ 30'Throw Line, Jim Buoy <br />12" O.C.E.W. <br />Hook: (2) Rainbow 153 <br />Steel: ASTM GR40, A615 <br />Test Kit: Taylor K-2006, Taylor K-1 766 Sodium <br />Poles: (3) Jed, 16'Straight <br />Chloride <br />Heater: None <br />Testing Kit Where Applicable <br />ADA Lift: This pool is for the sole use of private <br />Ladder: SR Smith Custom <br />residents and their guests and will not be <br />See detail sheet <br />open for general public use - therefore this <br />Tread: 6" Maximum from wall, 3" Minimum <br />pool is exempt from ADA requirements. <br />from wall. <br />Finish: Floors and walls shall be white or <br />Crossed braced stainless steel, slip -resistant <br />pastel in color and shall have the <br />treads, 28" <br />characteristics of reflecting rather than <br />minimum above deck. Must have caps or <br />absorbing light. The finish coating shall have <br />bumpers that rest firmly against pool wall. <br />a dry ug"Iness level 1%,,IL: L UlUt=:) UI OV.V UI <br />greater and a wet luminous reflectance <br />value of (CIE Y) value of 50.0 or greater, as <br />determined by the test results provided by <br />the manufacturer, utilizing testing <br />methodology from American Standard ASTM <br />D4086, <br />ASTM El 477, ASTM El 347. <br />Eauioment Substitutions <br />Post Pool Rule S <br />NO FOOD OR BEVERAGES IN THE POOL OR ON POOL WET <br />DECK. COMMERCIALLY BOTTLED WATER IS ALLOWED ON <br />THE POOL WET DECK FOR POOL PATRON HYDRATION. <br />NO GLASS OR ANIMALS IN THE FENCED POOL AREA OR 50 <br />FEET FROM UNFENCED POOL. <br />BATHING LOAD 103 PERSONS. <br />POOL HOURS: DAWN TO DUSK. <br />SHOWER BEFORE ENTERING. <br />DO NOT SWALLOW THE POOL WATER IT IS RECIRCULATED. <br />DO NOT PLACE FURNITURE IN THE POOL. -90 <br />POOL MAXIMUM DEPTH: 5 FEET <br />NO DIVING -as <br />WARNING: DROP OFF AT <br />SUN -SHELF IS 4 FEET DEEP <br />0 <br />PUMPS TO BE INTERLOCKED WITH CHEMICAL FEEDERS. SYSTEM WILL SHUT DOWN AND <br />AUDIBLE ALARM WILL SOUND IF THE CHEMICAL FEED PUMPS ARE NOT IN OPERATION OR <br />PROPER CHEMICAL TREATMENT IS MAINTAINED. <br />SUBSTITUTIONS: ALL PRODUCTS SHALL <br />BE PROVIDED (AS SPECIFIED HEREIN) BY THE CONTRACTOR WITHOUT <br />EXCEPTION. <br />a. HOWEVER, IF A POSSIBLE SUBSTITUTION MIGHT RESULT IN A <br />SUBSTANTIAL COSTS SAVINGS FOR THE OWNER / CLIENT AND IT IS <br />DETERMINED BY GARDNER COLLINS ENGINEERING THAT THE PRODUCT SUBSTITUTION IS <br />ACCEPTABLE AND SUBSTANTIALLY EQUAL TO THE SPECIFIED <br />PRODUCT, A WRITTEN APPROVAL OF THE SUBSTITUTION WILL BE <br />ISSUED BY GARDNER COLLINS. THE CONTRACTOR SHALL NOT <br />PROCEED WITH THE POSSIBLE SUBSTITUTION UNLESS THE WRITTEN <br />APPROVAL IS PROVIDED BY GARDNER COLLINS. ALL SUBSTITUTION REQUESTS <br />SHALL BE MADE IN WRITING AND APPROVED PRIOR TO BID BY THE <br />CONTRACTOR AND SHALL INCLUDE THE FOLLOWING INFORMATION: <br />L NAME AND ADDRESS OF PROJECT <br />NAME OF CONTRACTOR <br />iii. NAME AND DESCRIPTION OF THE ORIGINAL SPECIFIED <br />EQUIPMENT OR MATERIAL <br />iv. THE SPECIFIC AMOUNT OF COSTS SAVINGS TO BE RETURNED <br />TO THE OWNER IF THE SUBSTITUTION IS APPROVED BY GARDNER COLLINS <br />(NOTE: WITHOUT A SUBSTANTIAL COSTS SAVINGS TO THE <br />OWNER, GARDNER COLLINS WILL MOST LIKELY DECLINE TO APPROVE ANY <br />SUBSTITUTION REQUEST). <br />vi. FOR THE NEW PRODUCT: A COMPLETE MANUFACTURERS'CUT <br />SHEET, DESCRIPTIVE BROCHURE AND OR MANUFACTURERS' INSTALLATION INSTRUCTIONS, <br />Vii. ALL THE ABOVE INFORMATION SHALL BE PROVIDED IN <br />ELECTRONIC FORMAT (PDF OR SIMILAR) TO GARDNER COLLINS <br />b. THE USE OR INSTALLATION OF UNAUTHORIZED EQUIPMENT OR <br />MATERIAL(S) SUBSTITUTIONS (THOSE NOT AUTHORIZED IN WRITING <br />BY GARDNER COLLINS), ALTERNATE, INADEQUATE, SUB -STANDARD WORKMANSHIP, <br />OMISSIONS, DEVIATIONS, IMPLEMENTATION OF UNAUTHORIZED <br />DETAILS AND/OR UNAUTHORIZED DIMENSIONS SHALL TOTALLY <br />RELIEVE GARDNER COLLINS FROM ALL LIABILITY AND RESPONSIBILITY FOR THE <br />SAFETY OR PERFORMANCE OF THE PROJECT DESCRIBED HEREIN. <br />*NOTES: <br />1) NO NIGHT SWIMMING ALLOWED PRIOR TO <br />PROVIDING THE DOH WITH AN ENGINEER'S <br />APPROVED DECK ILLUMINATION DESIGN AND <br />PHOTOMETRIC CALCULATIONS STUDY AND <br />RECEIVING APPROVAL FROM THE DOH FOR NIGHT <br />SWIMMING. <br />2) OWNERSHIP MAY ADD ADDITIONAL RULES TO <br />SIGN. <br />3) POOL RULES LETTERS TO BE I " HIGH MIN. <br />EXCEPT "NO DIVING", "WARNING: DROP OFF AT <br />SUN -SHELF IS X FEET DEEP" AND "POOL MAXIMUM <br />DEPTH: X FEET" SHALL BE 4" HIGH MIN. <br />4) MAX. POOL DEPTH TO BE 2" LETTERING. <br />I" HIGH LETTERS MIN. [TYP.1 <br />2" HIGH LETTERS MIN. <br />4" HIGH LETTERS MIN. <br />0 <br />RESTROOM LOCATOR SIGN_ <br />REST ROOMS <br />=0* <br />PROVIDED BY OWNERSHIP <br />Restrooms <br />Outside access to facilities shall be provided for bathers at outdoor pools and if they are not <br />visible from any portion of the pool deck, signs shall be posted showing directions to the <br />facilities. These directions shall be legible from any portion of the pool deck and the letters <br />shall be a minimum of one inch high. Walkways shall be provided between the pool and the <br />sanitary facilities, and shall be constructed of concrete or other nonabsorbant material <br />having a smooth slip resistant finish for the first 15 feet of the walkway measured from the <br />nearest pool water's edge. <br />Floors: smooth, non -slip, impervious, pitched to floor drains, cove wall to floor, no carpet, <br />duckboard or footbaths. Provide permanent towel, tissue, soap dispensers and waste <br />baskets. Label doors. Install hose bib w/ vacuum breaker, either in resorts or outside nearby <br />Water shall be from an approved potable source with air break. Diaper changing tables shall <br />be provided at facilities that cater to families with small children. <br />NOTE: Restrooms are located within 200 FT walking distance of pool <br />waters edge. <br />RESTROOM FACILITIES: <br />• ARE WITHIN 200 FEET WALKING DISTANCE FROM THE WATERS EDGE. <br />• SHALL BE AT LEAST AS INDICATED ON THE FOLLOWING TABLE: <br />TOTAL AREA <br />IN SQ. FT. <br />MEN'S RESTROOM <br />URINAL W/C LAVATORY <br />WOMEN'S RESTROOM <br />W/C LAVATORY <br />0-2,500 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2,501 - 5,000 <br />2 <br />1 <br />1 <br />5 <br />1 <br />5,001 - 7,500 <br />2 <br />2 <br />2 <br />6 <br />2 <br />17,501 -10,000, <br />3 <br />1 3 <br />1 3 <br />1 9 <br />1 3 1 <br />OCCUPANT LOAD CALCULATIONS <br />IN ACCORDANCE WITH NFPA 101, 2018 EDITION <br />(FROM TABLE 7.3.1.2 ) <br />SWIMMING POOL WATER SURFACE: <br />SWIMMING POOL DECK AREA: <br />SWIMMING POOL OCCUPANT LOAD <br />TOTAL OCCUPANT LOAD: <br />5,455 / 50 = 109.1 <br />+ 6,707 / 30 = 223.5 <br />332.6 <br />MINIMUM REQUIRED EGRESSES PER SECTION 7.4.1: 1 - 500 2 <br />PANIC HARDWARE REQUIRED WHEN OCCUPANCY LOAD 501-1000 3 <br />IS GREATER THAN 100 .> 1001 4 <br />332 <br />2 <br />MINIMUM BATHER LOAD & FLOW RATE CALCULATIONS <br />IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, SEVENTH EDITION <br />(FROM SECTION 454. 1. 1.1 ) <br />UNIT COUNT: 715 NON -TRANSIENT UNITS <br />715 LIVING UNITS 17 = 103 MINIMUM REQUIRED BATHER LOAD <br />103 REQUIRED BATHERS X 5 GALLONS PER MINUTE PER BATHER = 515 MIN. REQD FLOW I <br />POOL ILLUMINATION REQUIREMENT <br />(incandescent equivalent or 10 Lumens: <br />5,455 SF X 0.5 2,727.5 SF <br />2,727.5 SF/300 6.78 MIN. # OF U/W LIGHTS REQ'D = 9 <br />TOTAL NUMBER OF LIGHTS PROVIDED = 11 <br />11, <br />0 <br />J <br />(L <br />�e <br />M <br />Cib <br />Q <br />0 <br />0 <br />W <br />a: <br />0 <br />LL <br />2 <br />4 <br />20) <br />0 <br />0 <br />2 Lo <br />0 OD <br />U <br />M <br />-q- <br />(y) <br />o�, <br />F" <br />CS4 <br />Z <br />< <br />LU <br />t: <br />:D <br />(y) <br />00 <br />-0 <br />-q- <br />(Y) <br />< <br />0 <br />1`14 <br />(y) <br />--1 <br />--t <br />o? <br />04 <br />"14- <br />0 <br />< <br />F- <br />rl� <br />0 <br />Z <br />Q <br />Q:� <br />0 <br />LL <br />'= <br />(3) <br />> <br />-;:r <br />C-4 <br />0 <br />F- <br />=) <br />< <br />LL- <br />0 <br />LL1 <br />F- <br />0, <br />LLJ <br />I.- <br />< <br />Z <br />F- <br />0 <br />0 <br />0 <br />(y) <br />J <br />0 <br />0 <br />(L <br />LO <br />Z <br />0 <br />0 <br />Z <br />LL <br />< <br />LO <br />LLJ <br />IL <br />U) <br />W <br />Z <br />UJI <br />M <br />0 <br />0 <br />LLI <br />UJ <br />0 <br />N <br />Z <br />REV. I DESCRIPTION I DATE I <br />DRAWN <br />Z-10 <br />DATE <br />12-17-2021 <br />PERMIT SET 1 12-10-2021 <br />CHECKED <br />RIVIT <br />SCALE <br />SHEET 2 OF 121 <br />N <br />PE-2 <br />