My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7034-7046 Ripple Pond Lp
Zephyrhills
>
Building Department
>
Building Plans
>
7034-7046 Ripple Pond Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:25:43 PM
Creation date
2/19/2025 2:13:58 PM
Metadata
Fields
Template:
Building Plans
Street #
7034-7046
Location
Ripple Pond Lp
Contractor
Lennar Home
Building Plans - Permit #
5470-5473
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cn <br />3 <br />v <br />v <br />to <br />Q <br />a <br />I <br />00co <br />O <br />J <br />to <br />LO <br />to <br />t <br />L0 <br />a> <br />`v <br />Q <br />C'0O <br />0 <br />I <br />Q <br />J <br />O <br />ir) <br />b <br />1 <br />to <br />co <br />LO <br />0 <br />a> <br />v <br />cn <br />O <br />.a <br />a <br />Ot <br />Q <br />0 <br />d <br />C <br />F— <br />a <br />E <br />`v <br />i <br />`a <br />v <br />c <br />0 <br />U <br />0 <br />a <br />c <br />0 <br />a <br />0 <br />t� <br />N <br />4 <br />0 <br />a <br />N <br />N <br />0 <br />m <br />-v <br />rn <br />WALL LEGEND <br />8'-8" TOP OF MASONRY WALL <br />(GARAGE) <br />9'-4" TOP OF MASONRY WALL <br />18'-8" TOP OF MASONRY WALL <br />+ . . -2HOUR FIRE RATED SEPARATION <br />WALL <br />44" TOP OF MASONRY WALL <br />(LANAI) , W/ SHAFT LINER ABOVE <br />TO BOTTOM SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-18'-8" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />20'-0" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />TYP, INTERIOR WALL <br />BEARING WALL <br />I <br />I <br />I <br />r-------------------------- <br />(1666) <br />SYMMETRICAL <br />B <br />SYMMETRICAL <br />(1666) <br />I <br />— — — — — — — — — — — — — — — — — — — — — — — — — -- <br />(1787) <br />2nd FLR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />Riser Diagram <br />4 UNIT BUILDING <br />2/0 CU GEC <br />CONNECTED <br />TO UFER AND <br />(2) RODS <br />600 AMP <br />SERVICE <br />00 <br />150 AMP <br />00 <br />150 AMP <br />150 AMP <br />150 AMP <br />(2) 3" SCH 80 PVC CONDUITS <br />WITH (2) 500 MCM XHHW AL <br />AND (1) 350 MCM XHHW AL <br />EACH CONDUIT <br />(4) METERS PER BANK <br />(1) METER BANKS PER <br />4-UNIT BLDG. <br />(1) 1 " SCH 80 PVC CONDUIT <br />WITH (2) 2/0 XHHW AL <br />(1) #1 XHHW AL <br />(1) #4 XHHW AL <br />TYPICAL ALL UNITS <br />NOTE: <br />• ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH <br />APPLICABLE PROVISIONS OF THE NFPA 70 - 17, LOCAL CODES AND <br />THE LOCAL POWER CO. <br />• INSTALL 2" CONDUIT TO METER CAN <br />• INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended forbid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors, <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12, Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14, Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be Included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />104 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />�Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />GM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />tL <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W! ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />t <br />o �05 <br />cc <br />N A vQ <br />•N -6�� i <br />N W`C.t <br />d i3 Nr' <br />10 <br />yi:' C1 c4 y` <br />i' <br />f <br />N <br />N <br />0 <br />N <br />c� <br />0 <br />Co <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />II-- a E <br />QC C' M 8 <br />V <br />W Cc:N <br />po <br />h <br />QS <br />i nt-�� <br />d/i aj ch V suzzss <br />�\, C _I S <br />V J LL LL 5 <br />'C 0, <br />c <br />i.i W <br />a <br />d Y <br />Z N cc <br />0 <br />e2 <br />N r- <br />W (1) <br />Z co M Z <br />02 L1J <br />4 <br />0 N O U <br />< cs <br />W <br />❑❑ <br />M <br />ry o <br />z o <br />�c <br />N <br />-- <br />M <br />to Z a <br />CA s <br />(1) <br />� <br />c/7 <br />(a LLJ <br />U <br />0 <br />Ljj o <br />N w <br />V m <br />w_ J <br />x lr <br />8 <br />(� o <br />I c C/) <br />N <br />�w <br />< <br />E® <br />U <br />Z� <br />oa <br />L) p <br />EerCaes <br />wmZ3SZ>¢Y <br />0 <Z¢ <br />L <br />W0 <br />¢0 <br />u�® <br />OZ}Z°oT <br />0O <br />UO9 <br />O <br />83<ULLJOFF`u+ <br />c <br />O r <br />LL <br />O <br />>M <br />0 <br />17 <br />bi <br />117,111 <br />LL <br />0 <br />O - <br />LO <br />n04 <br />OHO <br />,Q <br />r <br />� O <br />oor <br />06 <br />C.0 <br />O <br />O <br />C fl <br />65 m <br />Q <br />a.•+ <br />NM <br />Lo <br />LO <br />N <br />r <br />M <br />E 00 <br />� <br />Z <br />pru <br />Z <br />N <br />a- <br />U _j Q 0 <br />JOB <br />NO: 22-06569-06566 <br />SCALE : AS NOTED <br />SHEET NO. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.