Laserfiche WebLink
t <br />6 <br />0 <br />y <br />List Of Abbreviations <br />A A/C AIR CONDITION E EL ELEVATION L LAV LAVATORY S SC SOLID CORE <br />AB ANCHOR BOLT ELEC ELECTRICAL LBL LABEL SCHED SCHEDULE <br />ACT ACOUSTICAL CEILING TILE ELEV ELEVATOR LBS POUNDS SCP SCUPPER <br />AD ADJUSTABLE, ADJACENT EMER EMERGENCY LF LINEAR FEET SD SOAP DISPENSER <br />AFF ABOVE REF FINISHED EQ EQUAL LT WT LIGHT WEIGHT SEAL SEALANT <br />FLOOR (SLAB) EQUIP EQUIPMENT SECT SECTION <br />AHU AIR HANDLER UNIT ESC ESCALATOR M MAS MASONRY SF SQUARE FEET <br />ALT ALTERNATE EWC ELECTRIC MAX MAXIMUM SHT SHEET <br />ALUM ALUMINUM WATER COOLER MECH MECHANICAL SIM SIMILAR <br />ANOD ANODIZED EXIST EXISTING MFR MANUFACTURER SPEC SPECIFICATION <br />APPROX APPROXIMATE EXP EXPANSION MH MANHOLE SS STAINLESS STEEL, <br />ARCH ARCHITECT EXT EXTERIOR MIN MINIMUM SERVICE SINK <br />AUTO AUTOMATIC MIN MINIMUM, MINUTE STD STANDARD <br />F FACP FIRE ALARM MISC MISCELLANEOUS STL STEEL <br />B B 0 BOTTOM OF CONTROL PANEL MLDG MOLDING STOR STORAGE <br />BD BOARD FD FLOOR DRAIN MO MASONRY OPENING STRUC STRUCTURAL <br />BLDG BUILDING FDN FOUNDATION MR MOISTURE RESISTANT SUSP SUSPENDED <br />BM BEAM FIN FINISHED MTD MOUNTED SY SQUARE YARD <br />BRG BEARING FLR FLOOR MTL METAL <br />BTM BOTTOM FR FIRE RESISTANT MUL MULLION T T TREAD <br />BUR BUILT UP ROOF FR-S FIRE -RETARDANT T&G TONGUE & GROOVE <br />WOOD TREATMENT N NIC NOT IN CONTRACT TBL TABLE <br />C CB CATCH BASIN FT FEET, FOOT NOM NOMINAL TELE TELEPHONE <br />CG CORNER GUARD FTG FOOTING NTS NOT TO SCALE TEMP TEMPERED <br />CI CAST IRON FURR FURRING THK THICK <br />CJ CONTROL JOINT FUT FUTURE 0 OC ON CENTER TLT TOILET <br />CL CENTER LINE OD OUTSIDE DIAMETER TO TOP OF <br />CLG CEILING G GA GAUGE OPP OPPOSITE TPD TOILET PAPER <br />CLO CLOSET GAL GALLON OVFL OVERFLOW DISPENSER <br />CLR CLEAR GALV GALVANIZED TS TUBE STEEL <br />CMU CONCRETE GB GRAB BAR P PL PLATE TV TELEVISION <br />MASONRY UNIT GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TYP TYPICAL <br />CO CLEAN OUT GYP GYPSUM pLg� PLASTER <br />COL COLUMN PLUMBING U UON UNLESS OTHER- <br />CONC CONCRETE H HB HOSE BIBB PLWD PLYWOOD WISE NOTED <br />CONST CONSTRUCTION HC HOLLOW CORE PNL PANEL UTIL UTILITY <br />CONT CONTINUOUS HDW HARDWARE PR PAIR <br />CONTR CONTRACTOR HM HOLLOW METAL PREFAB PREFABRICATED V VB VINYL BASE <br />CORR CORRIDOR HORIZ HORIZONTAL PT POINT VCT VINYL COMPOSITE TILE <br />CT CERAMIC TILE HR HOUR PT PRESSURE TREATED VERT VERTICAL <br />CTR CENTER HT HEIGHT PTD PAPER TOWEL DISPENSER VEST VESTIBULE <br />CU CONDENSING UNIT HTG HEATING PVC POLY VINYL CLORIDE VIF VERIFY IN FIELD <br />CW COLD WATER HVAC HEATING, VENTILATING VTR VENT THRU ROOF <br />& AIR CONDITIONING Q QT QUARRY TILE VWC VINYL WALL COVERING <br />D DBL DOUBLE HW HOT WATER R R RADIUS, RISER, W W WIDTH <br />DEPT DEPARTMENT <br />DIET DETAIL I ID INSIDE DIAMETER THERMAL RESISTANCE W/ WITH <br />DF DRINKING FOUNTAIN IN INCH RD ROOF DRAIN WIO WITHOUT <br />DIA DIAMETER INCL INCLUDING RECP RECEPTACLE WC WATER CLOSET <br />DIM DIMENSION INSUL INSULATION REF REFERENCE WD WOOD <br />DISP DISPENSER INT INTERIOR REFR REFRIGERATOR WH WATER HEATER <br />DN DOWN INV INVERT REG REGLET WP WATERPROOF <br />DS DOWNSPOUT REINF REINFORCEMENT WT WEIGHT <br />DWG DRAWING J JAN JANITOR REQ REQUIRED WWF WELDED WIRE FABRIC <br />JB JUNCTION BOX REV REVISION WWM WELDED WIRE METAL <br />E EA EACH JT JOINT RM ROOM <br />EB EXPANSION BOLT RND ROUND Y YD YARD <br />EIFS EXTERIOR INSULATING L L LENGTH RO ROUGH OPENING <br />FINISH SYSTEM LAM LAMINATE RTU ROOF T P UNIT <br />EJ EXPANSION JOINT <br />Legend <br />x -- GRID DESIGNATION BUILDING SECTION <br />A301-2 A301-2 <br />102 ROOM NUMBER SHEET NUMBER SECTION NUMBER <br />102A DOOR NUMBER '4� WALL SECTION <br />A30�2� <br />® WINDOW TYPE SHEET NUMBER SECTION NUMBER <br />O2 STOREFRONT TYPE A501-6 SECTION DETAIL <br />WALL TYPE SHEET NUMBER DETAIL NUMBER <br />O5 KEY NOTE A888-88 DETAIL REFERENCE <br />© REVISION NUMBER SHEET NUMBER DETAIL NUMBER <br />TO SOMETHING ELEVATIONS TAGS '? EXTERIOR ELEVATION <br />XX'-xx A201-2 MARKERS <br />;y� SHEET NUMBER ELEVATION NUMBER <br />SPOT ELEVATION TAG <br />• <br />4 A401 2 INTERIOR ELEVATION <br />NORTH ARROW MARKERS <br />N <br />SHEET NUMBER 3 ELEVATION NUMBER <br />BRICK . ° • CONCRETE PLYWOOD <br />MASONRY \���\�� ECOOMPHACTED STEEL <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL <br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS, THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR <br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />GYPSUM <br />: • ' • D <br />■■■■■■RIGID <br />■■■■■■ <br />i l�r:% <br />. <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS A <br />FULL FIRE ALARM SYSTEM. THESE SYSTEMS SHALL BE MODIFIED <br />AS NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED <br />TENANT SPACES. THE CONTRACTOR SHALL SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE <br />LOCAL JURISDICTION FOR PERMITTING. NO WORK ON THE FIRE <br />PROTECTION SYSTEMS SHALL TAKE PLACE UNTIL THE REQUIRED <br />PERMITS ARE OBTAINED BY THE FIRE PROTECTION SUB <br />CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity Map "NDNTS <br />Tenant Buildout for Space B 1 B2 <br />Building B at Zephyr Commons <br />7952 & 7954 Gall Blvd, Zephyrhills, FL <br />AREA OF INTERIOR <br />WORK FOR B1B2 <br />Scope of Work- <br />1. THE SCOPE IS LIMITED TO TENANT SPACE 131132 IN BLDG B. <br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES, <br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES.. <br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER <br />THAN BLDG B. <br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE <br />AREAS IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS. <br />5. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE FINISHES, AWNINGS, STONE WORK, OR DECORATIVE <br />TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS. <br />6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE STOREFRONT SYSTEMS OR DECORATIVE WINDOWS. <br />7952 & 7954 GALL BLVD, ZEPHYRHILLS, FLORIDA 7. THE SCOPE INCLUDES MAKING ONE OF THE EXISTING REAR DOORS INOPERABLE. THE SCOPE DOES NOT <br />INCLUDE ANY OTHER WORK ON ANY OTHER REAR DOORS. <br />8. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS <br />REQUIRED TO ADD AN EXHAUST FAN AND A VENT FOR THE NEW RESTROOMS. THE SCOPE DOES NOT <br />INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS. <br />2Y ZEPHY S, I E�MARSHAUS OFFICE <br />Date: \ 9. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE <br />Code Information"'''"5` - NEW TENANT DEMISING WALL. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED. <br />10. THE SCOPE INCLUDES ONE NEW TENANT DEMISING WALL. <br />JURISDICTION AUTHORITY 11. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING AND RIGID INSULATION ON THE INSIDE <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT Cur be adv�ed this r�e"w of plans submitted is a OF THE ENTIRE SIDE MASONRY WALL AND ON THE REAR MASONRY WALL INSIDE THE RESTROOM ONLY. <br />5335 8TH STREET (813) 780-0020 - PHONE assist the contractor in compliance with 12. THE SCOPE INCLUDES INSTALLING TWO NEW RESTROOMS PER ADA REQUIRMENTS. <br />safety co ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX des. This review is t <br />ADOPTED CODES: <br />BUILDING: <br />FIRE: <br />PLUMBING: <br />MECHANICAL: <br />ELECTRICAL: <br />FUEUGAS: <br />ACCESSIBILITY: <br />ENERGY: <br />to be a dal approval of the submitted plans. <br />intendedt is con13. THE SCOPE INCLUDES INSTALLING A GYP BOARD CEILING IN THE RESTROOMS. THE SCOPE DOES NOT <br />tractors sole responsibility to ensure th e plans mare in INCLUDE ANY CEILINGS IN THE REST OF THE SPACE. <br />ate wmpficm with all aP*abie NFPA codes and 14. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF <br />FLORIDA loser' Inthewent ft further examination or DECK OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK ON ANY OF THE MASONRY <br />soleFLORIDA FIRBUILDIPREVENTION CODE BUILDINGNG CODE, - 2007W20077 (2009 AMENDMENTS)I 2009 the site�s� tion reveals areas p{ , it be OR LIGHT GAUGE FRAMING. <br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDME � Sareas MSy, at � sote expense 10 <br />FLORIDA BUILDING CODE, PLUMBING - 2007 (WI 2009 AMENDMENTS) a�on�• lire City assumes no 15. THE SCOPE INCLUDES SAW -CUTTING THE EXISTING FLOOR SLAB AS NEEDED TO PROVIDE THE NEW <br />FLORIDA BUILDING CODE, MECHANICAL - 2007 (WI 2009 AMENDMENTS)ponsibility for ailure to be in canoe RESTROOMS. <br />FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) With all VPk" NFPA Codes and loci Or tmce0, NATIONAL ELECTRIC CODE)g <br />LAB THAT IS SA*CUT. IT <br />FLORIDA BUILDING CODE(CHAPTER 27 - NFPA?FUEUGAS 2007 (WI2009 AMENDMENTS) 1fi INCLUDES POURING A NEW SLAB IN THE AREA OFF THE EXISTING SLAB . THE SCOPE INCLUDES RE -POURING ANY PORTION OF THE EXISTING LEAVE -OUT UNDER THE NEW ALS0 <br />FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) RESTROOMS AND THE NEW TENANT DEMISING WALL ONLY. <br />(CHAPTER 11- FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) 17. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). INCLUDES TURNING DOWN THE SPRINKLER HEADS AND MOVING THEM AS NEEDED TO FIT THE CEILING <br />LAYOUT. THE SCOPE INCLUDES DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S <br />SPECIALTY ENGINEER THROUGH HIS SHOP DRAWINGS. <br />BUILDING AND CONSTRUCTION DATA <br />18. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE WATER SERVICE FOR THE RESTROOMS. <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE 11-13, FULLY SPRINKLERED <br />19. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT <br />5 IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 5031D WORK TO ANY OF THE EXISTING CLEAN OUTS. <br />MAXIMUM HEIGHT 56-0" - FOUR STORIES <br />ACTUAL HEIGHT 38'-6" - ONE STORY <br />MAXIMUM AREA 50,000 SF" <br />ACTUAL AREAS 15,137 SF <br />"- THE MAXIMUM AREA ALLOWED BY TABLE 503 HAS BEEN INCREASED <br />FROM 12,500 SF TO 50,000 SF AS ALLOWED BY FBC 506.1 & 506.3 <br />NOTE: <br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY <br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS <br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />CLIENT: PRIMERICA GROUP ONE, INC. <br />3629 MADACA LANE <br />TAMPA, FL. 33618 <br />(813) 933-0629 PHONE <br />(813) 935-3420 FAX <br />CONTACT: ADAM ROBINSON <br />CIVIL AVID GROUP <br />ENGINEER: 8659 BAYPINE ROAD, STE 304 <br />JACKSONVILLE, FLORIDA 32256 <br />(904) 7374001 PHONE <br />(904) 252-7030 FAX <br />frA U <br />A-e_� ` E DATE - �-(C <br />(Ilk ITY OF ZEPHYRHILLS <br />PLANS EXAMINER <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUILDING <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />MECHANICAL CUHACI & PETERSON, ARCHITECTS, LLC <br />AND 1925 PROSPECT AVE <br />ELECTRICAL ORLANDO, FL 32814 <br />ENGINEERS: (407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />SHEET NO. <br />ARCHITECTURAL <br />20. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF THE EXISTING ABOVE GROUND STUBS -IN <br />FOR SPACE 131 B2. <br />21. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO <br />THE SANITARY OR VENT SYSTEMS OTHER THAN WHAT IS SHOWN ON P101. <br />22. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE COLD WATER MAIN, OR ANY OF <br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE COLD WATER BRANCH LINE OTHER <br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER PIPING. <br />23. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR <br />FUTURE CONNECTION TO THE COLD WATER SYSTEM OTHER THAN WHAT IS SHOWN ON P101. <br />24. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE. <br />25. THE SCOPE DOES NOT INCLUDE ANY WORK TO EITHER OF THE EXISTING 4 TON RTU'S THAT ARE ABOVE <br />SPACE 131 B2. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY OF THE OTHER RTUS OR ANY OF THE <br />EXISTING CONDENSATE LINES. <br />26. THE SCOPE DOES NOT INCLUDE PROVIDING ANY HVAC DISTRIBUTION. COMPLETE DISTRIBUTION <br />INCLUDING DUCTING, SUPPLY DIFFUSERS, RETURN GRILLES, ETC SHALL BE PROVIDED AS PART OF THE <br />FUTURE TENANT BUILD OUT SCOPE OF WORK. <br />27. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT, <br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METERS OR TENANT DISCONNECTS. <br />28. THE SCOPE INCLUDES RELOCATING THE EXISTING ELECTRICAL CONDUIT STUB -INS. THE SCOPE ALSO <br />INCLUDES PROVIDING TWO NEW 200 AMP TENANT PANELS CONNECTED TO THE EXISTING DISCONNECTS <br />VIA NEW WIRE PULLED THROUGH THE EXISTING EMPTY CONDUITS. <br />29. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANELS. <br />30. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOXES ON THE FRONT <br />AND SIDE OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANELS. <br />31. THE SCOPE INCLUDES WIRING THE EXISTING RTU'S AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM <br />TO THE TENANT PANELS. <br />32. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE <br />BUILDING OR THEIR WIRING. <br />33. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURES ON <br />THE REAR OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANEL VIA A LIGHT SWITCH. <br />34. THE SCOPE INCLUDES RELOCATING ONE OF THE EXISTING EXIT LIGHTS. THE SCOPE ALSO INCLUDES <br />REWIRING THE EXISTING EXIT AND EMERGENCY LIGHTS TO THE NEW TENANT PANELS. <br />35. THE SCOPE INCLUDES PROVIDING NEW 2' x 4' FLUORESCENT LIGHT FIXTURES INSIDE THE RESTROOMS <br />ONLY. THE REMAINDER OF THE LIGHTING SYSTEM SHALL BE PROVIDED AS PART OF THE FUTURE TENANT <br />BUILD OUT SCOPE OF WORK. <br />36. THE SCOPE INCLUDES RELOCATED THE EXISTING TELEPHONE CONDUIT STUB -INS. THE SCOPE DOES NOT <br />INCLUDE ANY OTHER CHANGES TO THE EXISTING TELEPHONE SYSTEM. <br />37. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM AS <br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE <br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS. <br />Drawing Index <br />TITLE ON SHEET PERMIT SET <br />2010 11-19 <br />COVER SHEET <br />X <br />PROJECT SITE PLAN <br />X <br />SPACE 131132 PLANS <br />X <br />SPACE 131132 DETAILS <br />X <br />SPACE 13162 DETAILS <br />X <br />61132 SPECIFICATIONS <br />X <br />131 B2 SPECIFICATIONS <br />X <br />B1 B2 SPECIFICATIONS <br />X <br />FIRE PROTECTION NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE 61132. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL BE <br />DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING <br />P101 PLUMBING GENERAL INFORMATION FLOOR PLAN & RISERS X <br />MECHANICAL <br />M101 MECHANICAL GENERAL INFORMATION & FLOOR PLAN X <br />ELECTRICAL <br />E101 <br />E301 <br />E501 <br />FIRE ALARM NOT <br />ELECTRICAL PLANS <br />X <br />ELECTRICAL LEGEND SCHEDULES & RISER DIAGRAMS <br />X <br />ELECTRICAL SPECIFICATIONS <br />X <br />E - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE <br />ALARM SYSTEM <br />SHALL BE MODIFIED <br />AS NEEDED FOR SPACE 131132. ALL MODIFICATIONS <br />TO THE <br />FIRE ALARM <br />SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />En <br />- E <br />U <br />Cn$ <br />a <br />N <br />.--� <br />o <br />o <br />U_ <br />T <br />gCD <br />Q�d <br />oCD <br />ui <br />o <br />0 <br />C� <br />U <br />a rn <br />W Ia <br />~ <br />a <br />w <br />N = <br />r' a <br />