Laserfiche WebLink
12 <br />5� <br />HEEL <br />--------------------- —------- <br />12 <br />o 5 <br />T.O.M. -- —-------------F4------------ <br />HDR HGT. - - <br />TEXTURED <br />o CEMENTICIOUS <br />9 � FINISH ON C.M.U. <br />iI. <br />o (TYP.) <br />F. FL. <br />- -----------1--------------- <br />N <br />14'-0" RIDGE VENT <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />-- <br />_J <br />1' 0" <br />IE]aa177000 <br />�E] <br />FRONT ELEVATION — Al <br />---� - --- 12 <br />1...- <br />SCALE: 1 /4"= V-0" <br />WIDAZIl RZC14vl\h <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be Installed Independently such that each layer provides a <br />separate continuous plane and any flashing Intended to drain to <br />the water -resistive barrier Is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material In <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof Intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />12 <br />- <br />5_�—�,. 3 TAB SHINGLES. ROOF <br />I <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />"�`=JJ�_-_-._-��� ,-�_�:._.,-_, -. s �-_.�_-_ -.fit—���•�_-_ �, .� _ y._-.� _ �_ _ _ "---�--.as. -_ <br />J T.O.M. <br />-------------- <br />6" FASCIA <br />(TYP) <br />2'-0" <br />TEXTURED _ <br />CEMENTICIOUS 00 00 <br />FINISH ON C.M.U. Zo <br />(TYP.) <br />- - _ F.FL. <br />LEFT ELEVATION — Al <br />: 1 /4"=1'-011 <br />IN <br />v ( <br />.� C> 0, <br />_ j O� <br />o <br />Sl <br />To the best of the Engineer's knowledge, informadon and belief, <br />the structural plans and spedflcadons contained within these <br />drawings comply with the 2017 Florida Building Code . <br />Residential 6th Edition, Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />�_ <br />g g8� <br />Lo h <br />N aC ID LL <br />� i2 J 7! W <br />04I� <br />LL a <br />R <br />Q1NN . <br />�`p J �-- of W 111L�N�,,,��� <br />LL iL <br />ZgY <br />J <br />� O <br />a <br />01- <br />_ m-m0 <br />N � <br />I L <br />o �g� <br />Z <br />,w <br />V <br />o 6 <br />Z <br />000 <br />W <br />N <br />Z � <br />Z <br />Z rop <br />Q v <br />LZ � <br />- N <br />v <br />l <br />T <br />IIILLL <br />l.Ll <br />OW <br />V) <br />c <br />_W <br />U <br />c <br />r. 0 <br />H <br />Q <br />M <br />_J <br />E <br />cc Q <br />S <br />cc <br />E.8 <br />X <br />W <br />Z <br />�o <br />MIN <br />�IN <br />Z{_CI) <br />M <br />�v <br />J <br />�$z <br />r O <br />g <br />0 <br />W <br />� � <br />N_Z <br />F <br />�Ig <br />3 <br />�ul <br />M <br />� <br />W\ <br />0 <br />.� <br />Q <br />> <br />T <br />nC <br />W m <br />o <br />r <br />O N <br />N <br />�• <br />r <br />T <br />pJp � <br />T <br />i <br />r4I <br />00 <br />T_ <br />M <br />T— <br />O <br />N <br />Z <br />a. <br />U _J <br />Q <br />c <br />JOB <br />NO: <br />20-8072 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />