My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2838 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2838 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:49:06 PM
Creation date
2/19/2025 3:49:56 PM
Metadata
Fields
Template:
Building Plans
Street #
2838
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
1231
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />n <br />200 amp <br />150 amp <br />POWER CO. FEED---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />NEMA 1 <br />200 AMP <br />copper to egms & outlets <br />copper to 20 emp clos <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />OGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�--� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />fOr <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FEN <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />t;a <br />ELECTRIC PANEL <br />—�► <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />1W If---- ----- cJ GFI @44'IRRIGATA F.F. <br />---- <br />ION <br />GFI � VERIFY LOCATION <br />I W H ELECTRICAL PANEL I I <br />I O I II <br />I I <br />OWNERS' Sy ITE W.I.C. _ <br />2 CAR GARAGE <br />GFI FOR I I I <br />/ ROUGH -IN FOR / F G <br />I R. DOOM I I <br />/ OPT. CLG. FAN/ 1 I I I I <br />LIGHT PRE -WIRE IL <br />GFI @ 44"A.F.F. <br />S.D.------------!//I I I I I <br />_ I I I <br />1.L. i l l i <br />c.M I 0 T. I OPT. I 1 1 I I I <br />/ o D. <br />I <br />L------------ <br />7 <br />GFI @ 44" <br />I <br />A.F.F. <br />FAMILY RM <br />/qpurCH <br />I 19FOYE <br />- I <br />ENTRY <br />ROUGH -IN FOR / ` —" -- _ <br />OPT. CLG. FAN/ WP I <br />I LIGHT PRE -WIRE � .41. I--- &GFI I <br />I <br />U.C. OUTLET <br />I FOR DW <br />I <br />U.C. OUTLET <br />1 __ T I 1 ;/1 1 1 <br />PA I�O CAFE <br />1 <br />A !II 10 <br />IPENDANT AS <br />PER SPECS <br />►�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIil111111111 <br />I <br />OPT. <br />REF.I BEDROOM 2 <br />--rt- <br />GFI <br />I OUGH-IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />� '%1 <br />BEDROOM 31 S. <br />y <br />i cz\� <br />1 V V <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />C.M <br />N-40�' <br />"7 v A i .` BEDROOM 4 <br />_ATH <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4"=1'-0" <br />cQv <br />N <br />0 <br />Tote best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential Oth Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />a <br />oprp, <br />48 NN 9! <br />G <br />LQ v <br />CN LL <br />7u7� J w <br />_j <br />a <br />Q <br />in n .- LL a <br />gyp10 C')m w vi <br />J_LLLL t1 d <br />V <br />3 <br />W <br />�j l0 fV <br />g�rn a <br />Woo Z <br />rR <br />N &Z <br />Z <br />o" ❑0❑ <br />W <br />z <br />z <br />z <br />�- <br />U) <br />A <br />— R <br />V) <br />vC� <br />z <br />f6 <br />.O <br />Nt` <br />W <br />o <br />l/N <br />c <br />r— <br />. <br />U <br />¢ <br />0 <br />C" <br />M <br />"-a <br />E <br />=o <br />Q <br />M <br />- <br />g�� <br />Z <br />N fO <br />CD � <br />w <br />ado <br />m> <br />ra <br />C <br />o <br />ZZ <br />Z <br />G J <br />�J <br />o <br />Z <br />aS <br />d <br />215 <br />0 <br />L) <br />1M <br />^L1 <br />W <br />B <br />m <br />0 <br />CL <br />N <br />T <br />C) <br />T <br />d <br />In <br />r <br />I CID <br />C - <br />00 <br />r <br />tEo <br />r <br />N <br />Z <br />Z <br />E <br />E <br />:; <br />c <br />a <br />v <br />¢ o <br />JOB <br />NO: <br />20-8072 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.