My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2841 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2841 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:31:09 AM
Creation date
2/19/2025 3:50:30 PM
Metadata
Fields
Template:
Building Plans
Street #
2841
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
1024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n�1'I��I[111A�R'1® <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF • <br />HOME H C G <br />GARAGE SIDE 00 0 <br />5'-0" <br />STUB -OUT FOR O <br />GAS METER o F <br />(V <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />101-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 2 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />81-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />Pir)r.F 1 INF <br />+ + <br />+ + + + + -+ + + + <br />+ + + + + + + + + + + + + + <br />-}. <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + +io <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />'-0" (TYP.) <br />+ + <br />6'-0" <br />+ <br />+ + <br />6'.0" <br />+ + <br />10 <br />+ + + <br />+ + <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />t + <br />+ + <br />+ + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />.+ i + + + + + + + + <br />+ + <br />+ + <br />+ + + + + * + 4 <br />+ ++ <br />+ + + + + + + + + <br />L <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + <br />+ + <br />+ + <br />i' + ♦ <br />+ ++ <br />+ + + + + <br />+ <br />t� <br />`-RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 1140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />NOTE: I .. ......� .. ............_ ........ _ ......._....... __ . __ <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6", <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />v r h=20 block nd <br />*Non -stacking walls o e squas s a <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />areas=20 of high / <br />lateral load. <br />Squash block / <br />(2x4 minimum) —J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />i1/16" <br />One 10d box <br />or-20 sinker <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />- Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL -- STD. 90° HOOK IF BOND BEAM <br />w <br />STD.90° <br />CONT. #5 I HOOK <br />BAR <br />BOND BEAM STEP <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />=� OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" max. 4" max. -- Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />4 Series _ _Depth _End I_Intermediate <br />® 9-1/2" 2 8d 2 8d <br />BCI 5000s _ 11-7/8" 2 8d _ _ 3 8d <br />Clinch nails 14" 2-8d 5-8d - when 9-1/2" 2-8d 2-8d <br />BCI 6000s® 11-7/8" 2-8d 3-8d <br />possible BCI6500s® 14" 2-8d 5-8d <br />V_ 16" 2-8d 6-8d <br />11-7/8" 2-8d 3-8d <br />BCI 60s® 14" 2-8d 5-8d <br />Tight fit _" _ 16" 2-8d 6-8d <br />11-7 3-16d 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. I BCI 90s® 14 5-16d 5-16d <br />required when indicated or 4' max. 16" 6-16d 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />�- blocking and wall or beam below.* <br />Use 10dx3" nails at I <br />blocking panel *Non <br />require additional ca.valuala.ivi I. <br />6.� A 1Yz" ROUND HOLE MAY <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN %22" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT, <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />1-When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />SIMPSON MGT <br />w/(22)10d <br />�GIRDERTRUSS <br />NAILS TYP. <br />2X TOP PLATE <br />5/81 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />VAIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />,Install tight to, top flange. <br />Joist hanger <br />Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap --- � <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist henger. doesn't meet <br />height <br />- ] requirements <br />-0.6 X Joist <br />o depthlo <br />I —JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM--' • <br />SEE PLAN FOR--'•• Q . • <br />FOUNDATION INFO ' ' d• <br />STEM FOUNDATION <br />GRADE <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A * (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'4" <br />CENETERED @ PIPE <br />PENETRATION <br />1 <br />WWOi� <br />1 !1 1 �1.. <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />W <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />.� 4'd ,d <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d 4 d d <br />4. d d4 G <br />•4 <br />a G <br />4 , d 4 d <br />T <br />rr <br />4 <br />SEE FND. PLN. <br />00 SIZE & REINF. <br />'D VVIV <br />:w` <br />< <br />rn <br />5� <br />•�'••. L <br />o •••.....••' <br />Nttlkotl <br />" <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 0th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4 <br />8 a N ik <br />do <br />�i <br />a. <br />ycN�M W US�LLa as <br />W <br />0�rn d <br />Z <br />La <br />o <br />° °y <br />M <br />Z <br />Q O J <br />❑[]� <br />W <br />z <br />z <br />o <br />v <br />-, - <br />d N <br />13 <br />N <br />� <br />z <br />U <br />0, <br />f13 <br />�n <br />� <br />W-O <br />LnU <br />ftS <br />�-- <br />U <br />w <br />�— E <br />$ <br />i <br />_ <br />U � <br />• <br />Q Y <br />� ° <br />S� <br />ti <br />Cw <br />J <br />_ <br />IQ <br />w <br />00 <br />zn <br />�a <br />Q <br />~ C6 <br />� <br />O <br />a6 <br />o <br />_ <br />a E <br />�Q <br />�8 <br />W, <br />�z <br />N� <br />'0 <br />ow <br />W <br />�3 <br />a�Ln <br />i; LL <br />O <br />O <br />1z <br /><$ <br />�5 <br />O <br />2 <br />SI4 <br />e CV <br />Lo <br />L <br />T <br />D <br />> <br />.2 <br />m <br />tv <br />CO <br />Lo <br />-0 <br />o <br />a <br />O) <br />N <br />.� <br />1:C <br />r- <br />10 <br />00 � <br />2 <br />T <br />E <br />N <br />z <br />C <br />d <br />O <br />E <br />U -J <br />J <br />Q O <br />J <br />JOB <br />NO: <br />20-6578 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SIN 1 <br />its <br />w <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.