Laserfiche WebLink
0 <br />v <br />F <br />P @ 2 STORY <br />H.B. <br />= <br />60 <br />I <br />I <br />1 <br />= <br />N <br />N <br />N <br />24 - Y4 OPT. <br />- - - - REF. _ <br />12'- " <br />16" <br />5-SH <br />DEEP <br />- <br />D <br />S3 <br />2x6 WALL <br />r------------ <br />I I <br />I I <br />I I <br />266 <br />B.F <br />-- <br />- <br />I <br />I I j <br />I IS <br />'-8" <br />- <br />- <br />- <br />2 68 <br />OA <br />N <br />�.. <br />EDI <br />3 <br />-+ <br />7-- <br />KITCHEN <br />j 8'-9' FLwT <br />- G-- <br />LG. - <br />H1 i <br />- <br />- <br />CC <br />EDGE OF SLAB 2" <br />BEYOND WALL - <br />20'-6" <br />I I <br />I I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />j< <br />10 <br />I 1u_ <br />I tY 10 <br />I Iw <br />I � IZ <br />f p I J <br />w I <br />I > I <br />l o <br />I C <br />cO <br />N <br />a:36 35 <br />Li U <br />4'-0" <br />l _- -� <br />A <br />'' <br />--�- <br />6'-2" <br />6-6" <br />4'-10" <br />I I I <br />= <br />2 CAR GARAGE <br />I <br />PATIOo DINING ROOM <br />8'-8" FLAT CLG. <br />CARPET <br />o O <br />u7 <br />io <br />(3) 2X4 #2 SPF W/ <br />(3)16d TOENAILS @ <br />BASE <br />TYP @ 2 STORY <br />J <br />S6 <br />16'-48 <br />CrI <br />8 <br />i <br />8'-8" FLAT CLG. AFF <br />BUILDER TO PROVIDE <br />2'-6" io APPLIANCE PROTECTION <br />WHEN REQUIRED PER FBC <br />O <br />(3)2X4#2SPF W/ <br />(3)16d TOENAILST <br />N @ BASE <br />W.H. <br />I I I <br />I 1 <br />I I I <br />I I I <br />I I I <br />I I I <br />I D I I <br />I 33 I I <br />L----- -- --- <br />(3) 2X4 #2 SPF W/ 4'-0" '-0" <br />(3)16d TOENAILS <br />@BASE <br />I <br />FOYER- <br />8'-8" FLAT CLG.- <br />TILE _ B <br />1. 6'-0" ,-2„ I. <br />Q <br />v <br />N <br />0pf- <br />�I <br />g1 O <br />u i <br />T-8" T-8„ 3,-6" <br />4 <br />4 <br />2 #5'S <br />(' <br />9 <br />N <br />� <br />N <br />I <br />2068 B.F. <br />„DEE <br />�._-___ <br />---HDRAT7'-4--- <br />----------- <br />TRIG <br />8'_8"FLAT_C_L <br />- AFF <br />= <br />4 <br />5-SH <br />aD <br />r <br />_ <br />ON <br />M <br />WALL <br />+ FL 0 G <br />S3 - -- <br />PLUMBING LINE <br />TO SECOND <br />FLOOR �I <br />4'-0" <br />,_0„ <br />(2) #5'S N <br />co <br />= <br />00 <br />f4 <br />FAMILY ROOM f` <br />8'-8" FLAT CLG. <br />CARPET <br />FLOOR G.T. <br />- <br />a <br />(3) 2X4 #2 SPF 1__ <br />WI (3)16a 18'-8' F T G.1 <br />TOENAILS @ T <br />BASE __! __ L_ _ _. _ _ <br />42" SLOPING 12 <br />HALF WALL ° 11 <br />_ 10 <br />1 1 21 31 I 1 61 1 I9 <br />Up I I I I I I I I <br />G <br />I I I I I IS3r-11 I <br />FLEX <br />8'-8" FLAT CLG. <br />CARPET I <br />1 <br />I <br />Cl) O <br />TYP @ 2 STORY <br />J <br />S6II <br />rn <br />go <br />N <br />AC PAD AC PAD <br />°� <br />fO <br />in <br />H.B.. <br />J <br />S6 <br />TYP @ 2 STORY <br />(3) 2X4 #2 SPF W/ (3)16d 1 <br />TOENAILS @ BASE 8 <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 251 <br />S.H. <br />13 <br />20X38j <br />18}X37j <br />S.H. <br />14 <br />20 X 50j <br />18 } X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 } <br />S.H. <br />16 <br />20 X 72 <br />18 } X 714 <br />S.H. <br />11-12 <br />271/4X26 <br />26X254 <br />S.H. <br />11-13 <br />27 1/4 X 38 j <br />26 x 371 <br />S.H. <br />1 H4 <br />271 X 501 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 J X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 j X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 } X 50 <br />S.H. <br />25 <br />37 } X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 1 X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 } <br />S.H. <br />33 <br />54 X 38 Ij <br />52 } X 37 <br />S.H. <br />34 <br />54 X 501 <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FIRST FLOOR PLAN - 61 <br />SCALE: %4'=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculatlon of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />O G <br />SEE SN SHEET HO SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 <br />FIRST FLOOR LIVING 1093 <br />AREA <br />SECOND FLOOR LIVING 1489 <br />AREA <br />LIVING TOTAL 2582 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />EXT FRAME 2 x 4 1 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 1 R-19 KRAFT FACED <br />CONDITIONED CEILING I <br />(INS <br />TALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />"° .Owk <br />�. NS'E <br />C14 <br />t <br />lb ¢ <br />. <br />0`E <br />S J`Olk <br />��"'frfflf(il4ttl``ti�� <br />\`\ <br />. <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Englneer's signature and seal. <br />W <br />v <br />0 A LL <br />04 LL <br />to to J it W <br />(» <br />r/1NN� LL 6. <br />W r� <br />J <br />LL LL a <br />Z <br />J <br />rM 0 <br />It 0mm OJ <br />IL Z <br />m NCj 0 <br />N Q J <br />z <br />U <br />°" ❑DD <br />W <br />z <br />z <br />Q � <br />a <br />.o <br />�� <br />0 <br />EL <br />0 <br />to <br />o <br />c <br />U <br />0 <br />C%1 <br />O <br />M <br />J <br />E <br />S <br />Q <br />� � <br />t- <br />f•'� <br />oa <br />U <br />S <br />�z <br />z <br />a'.g <br />6 <br />- <br />° <br />?o <br />w <br />z�� <br />13J <br />J <br />� <br />gym• <br />8 <br />< <br />��z o <br />U <br />W4 <br />a <br />�w <br />r <br />04 <br />Lo <br />L <br />iu <br />c� <br />` <br />./ <br />a. <br />C s <br />CO <br />m <br />to <br />� <br />o <br />0)'� <br />■� <br />J N <br />T <br />r <br />(V r- <br />o <br />z <br />40 <br />z <br />E <br />N <br />B ui <br />` <br />m <br />c <br />a. <br />o <br />U J <br />< p <br />JOB <br />NO: <br />20-6578 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.0 <br />