ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />n <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />NEMA 1 <br />200 AMP <br />14 copper to lights a outlets <br />12 copper to 20 amp ckts <br />10.2 copper to WH <br />t03 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is Intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be In accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />Within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rwl- <br />HALF -SWITCHED DUPLEX OUTLET <br />I Oh <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />I) <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e� <br />TRACK LIGHT <br />�--- <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />rOr <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />[P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />HD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />@)SMOKE/CARBON <br />MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />9 <br />ELECTRIC METER <br />JIMIL <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />DISC. <br />:ram <br />UI• <br />�i <br />r----- u� -� <br />I CFI I <br />O <br />DINING ROOM <br />12'-0" <br />VE IFY METER <br />LOCATION WITH <br />BUI DER H.B. <br />—I <br />I <br />VERIFY LOCATION IRRIGATION _ _ _ <br />I <br />ELECTRICAL PANEL GFI @ 44" A.F.F. I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />/ I I I <br />\ I I I I <br />I I I I <br />I <br />I I I j <br />GAR. I I I <br />GFI @ 44" DOOR I I I <br />A.F.F. GFI I I I <br />2 CAR GARAGE <br />/PENDANT AS <br />/ PER SPECS \ \ Cn 0 <br />/ M <br />ROUGH IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />FAMILY ROOM / <br />\ I <br />L------------ <br />GFI @ 44" <br />A.F.F. <br />C.M \ FOYER <br />� tl� <br />f• <br />�1FLEX <br />A <br />-OFOR <br />e1al01911lalala n •LIGHT PRE -WIRE <br />- <br />TO LIGHT ME <br />AND <br />SWITCH <br />ABOVE <br />I <br />I <br />I <br />I <br />I <br />I <br />DB TR)� <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />N <br />ca <br />N <br />To the beat of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drwMng pages bearing <br />Engineers signature and seal. <br />LQ 0 <br />T J etW <br />0 <br />LL LL a <br />0 <br />9�p""? I <br />LL a <br />0 <br />J LL <br />Z_ <br />c� Cs <br />�. <br />W <br />f6 N t0 <br />&6 Xoa <br />Z <br />EL IL <br />to MZ <R <br />Z <br />V ❑❑❑ <br />z <br />Q� <br />�a) <br />4-J <br />o <br />LL <br />fp <br />V <br />rn <br />W <br />� <br />0 <br />c <br />� <br />a <br />�o <br />o <br />o <br />oLL00. <br />W'i <br />IM <br />00. <br />Z <br />9 V�UU <br />t� <br />S E <br />�06 <br />QU <br />a% <br />w <br />Zg <br />J <br />ibg <br />8 <br />U <br />W <br />T <br />V <br />xxZ <br />W O <br />= <br />Illllllllll� <br />O� <br />N <br />a 2 <br />A <br />F <br />O <br />v <br />ZIP <br />8 <br />.2N <br />= <br />Lo <br />CC <br />ai <br />W\ <br />� <br />e= <br />Z <br />C) <br />^C1 m <br />Lo <br />o <br />04o <br />r <br />N <br />= <br />J <br />00 C <br />r <br />m <br />r <br />N r— <br />H <br />o <br />Z <br />m <br />E <br />E <br />U <br />B Y <br />v <br />c <br />tl <br />JOB <br />NO: <br />20-6578 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />