Laserfiche WebLink
MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />F RESISITIVE <br />IJ/ BARRIER <br />(ASSEMBLED WINDOW) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING -� <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />1-L/1JI IILIV <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC <br />R703.2.1 AND FBCR 703.7.3 <br />Detail Instructions <br />Refer to the number marked as # in each detail that corresponds to the <br />numbered items in the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />WEATHER <br />JE BARRIER & <br />tARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN --� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOIE <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />8 2 <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />i� SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHII <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />FLASHING REQUIREMENTS <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall include <br />flashing as described in Section R703.4. A water -resistive barrier is described as a material behind an exterior wall covering that is intended to <br />resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. An exterior wall covering <br />is described as a material or assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weather -resistive <br />barrier, insulation, or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish systems, architectural trim and <br />embellishments such as cornices, soffits, and fascias. <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches <br />(152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a <br />manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a <br />Q <br />water-resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be <br />installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) <br />intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or greater than <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER 1 that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed <br />drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity <br />FLASHING SELF -ADHERED FLASHING --,,,,,or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All <br />exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class <br />SCORED 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the <br />RELEASE PAPER type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface <br />(BEFORE FOLDING, SCORE of the exterior wall finish. Approved corrosion resistant flashings shall be installed at the following locations: <br />RELADHESIVEASSHOWN) SE PAPER TO SE 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish <br />L <br />SELF -ADHERED FLASHING I � O . � �<�c�a� I � I / \ ( /�-•� <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8"CMU <br />4" OR 8" CMU <br />(PER SEAT DEPTH <br />FILL WITH GROUT <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />E <br />AM <br />SELF-ADHEF <br />J IYII1� <br />iCIL�»71Ie\�I <br />SHOWER SEAT <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />z <br />a <br />cc <br />W <br />a <br />CO <br />W <br />U <br />W <br />IX <br />er <br />3r <br />O <br />rn <br />SELF -ADHERED FLASHING <br />PATCH <br />,HERED FLASHING <br />Alt <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />8 2 <br />a <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />�Ground� <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2 INCH FLANGE <br />III <br />THIS <br />NATU <br />DO N( <br />DRIP <br />ACCE <br />SOFFIT/CANTILEVER <br />or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall <br />comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />2 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />5 1.2. In accordance with the flashing design or method of a registered design professional. <br />4 1.3. In accordance with other approved methods. <br />6 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco <br />7 copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -0 o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS SxSSt` 4 <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact, Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/211 to 211 <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />With ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />0 <br />N <br />i <br />o_ <br />To the best of the Engineers knowledge, IMorrnation and Wilef, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />F <br />� E <br />cc <br />X', <br />iv <br />O <br />t <br />7GCP N <br />LL <br />J # <br />a <br />a <br />to n & <br />y J C7 <br />W <br />LL <br />a W <br />0 <br />LL LL <br />1 <br />� <br />Z <br />� <br />' <br />L <br />{r CO <br />O t- <br />m So- <br />W <br />7 NN <br />pp <br />��pa <br />ILZGo <br />� NZ�$rn <br />ZN <br />O k� <br />❑❑❑ <br />W <br />CD <br />z <br />z � <br />z <br />�NQ) <br />- N <br />(D <br />LL <br />C1 <br />'' <br />r <br />C/1 <br />a <br />O <br />w � <br />d <br />u � <br />t <br />IN®~ <br />A <br />Q <br />� <br />M <br />N� <br />Zw <br />LJL <br />ao <br />wZ <br />Q <br />> <br />Z <br />Q <br />d EO <br />N U <br />s° <br />_® <br />Wp <br />96 <br />o E <br />�o <br />Ru <br />dyo <br />§U <br />Q¢ <br />2$ <br />Z�a <br />N<Z <br />:,_D L <br />wo <br />QO <br />WZ <br />W� <br />(0� <br />M <br />N <br />- a <br />tix <br />wo <br />ZLL <br />Z <br />� W <br /><W <br />�C <br />8 <br />aZ <br />W <br />c-3 <br />LL <br />= G <br />~� <br />JCID <br />J <br />^L1 <br />e <br />W <br />■ _>Nit <br />O <br />X <br />co <br />(DCL <br />Q <br />C -6 <br />m <br />tor**- <br />= <br />f <br />7 <br />O <br />C <br />0) <br />d' <br />■_ <br />J N <br />N <br />.- <br />�- <br />� \ <br />r <br />E <br />T_ <br />N � <br />o <br />Z <br />M <br />E C) <br />E <br />to <br />H <br />m ci <br />c <br />a <br />tJ � <br />Q p <br />JOB <br />NO: <br />20-6220 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />