My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3011 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3011 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:36:20 PM
Creation date
2/19/2025 3:53:32 PM
Metadata
Fields
Template:
Building Plans
Street #
3011
Location
Nubbin Ridge Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
247
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
maw :wu Ai - <br />3 <br />v <br />m <br />0C <br />J <br />N <br />0 <br />i <br />m <br />rn <br />0 <br />1 <br />N <br />0 <br />C <br />3 <br />FV— <br />Q <br />N <br />N <br />E <br />411 <br />tE <br />E <br />-) <br />i <br />X <br />t� <br />N <br />N <br />S <br />a <br />N <br />N <br />J9 <br />z <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE v r <br />15/32" CDX <br />co PLYWOOD OR <br />C7 7116" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+++ <br />+++ <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />/++ <br />++ <br />+ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />5000s 1.8/1.7 <br />3/4" p nel <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />,Hood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />woad panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />w <br />> <br />STD. 90° <br />CONT. #5 <br />BAR I <br />HOOK <br />�(�� BAR <br />CC <br />i CONT. <br />IOM <br />)UNDATION <br />) HIGHEST <br />)ND BEAM <br />i CONT. <br />IOM <br />)UNDATION <br />) HIGHEST <br />)ND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2 max ) <br />gap <br />• � 4 max. <br />-4 <br />Clinch nails <br />when <br />possible <br />1) Support batik of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y"GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth Guts. N.T.S. <br />-- -- - - Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non -stacking walls wall or beam below.* <br />require additional <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />11 lateral load. nail each side <br />10 -0 at bearing. <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" <br />STUB -OUT FOR j 1_011 p a <br />GAS METER O o <br />N _ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-51' <br />1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" 16" O.C. <br />1 T-3" <br />1) SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" f 10dl nails at 6" o.c. <br />�/ Provide adequate hearing <br />for each lapped joist. <br />lodnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />Id (see table below) <br />DO NOT cut, notch <br />or drill flanges it <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />1n14" <br />3-16d <br />3-16d <br />5-16d <br />5-16d <br />6-16d <br />6-16A <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* C <br />pits When joists meet over wall, provide <br />�1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6�1 A l 2' ROUND HOLE 6�� 6,1 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />V-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />1'-0" <br />1'-7" <br />1'-11" <br />2'-4" <br />2'-9" <br />3'-2" <br />3'-7" <br />Any 16" joist 12 <br />V-0" <br />1'-1" <br />1'-2" <br />V--2" <br />1'-3" <br />1'-9" <br />2'-4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />Span (it) 16 <br />V-0" <br />1'-1" <br />1'-2" <br />V-2" <br />1'-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />7' 2" <br />20 <br />V-0" <br />1'--1" <br />1'-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11" <br />W-11" <br />24 <br />V-0" <br />1'-1 " <br />1'-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10" <br />7' 2" <br />8'-4" <br />9'-0" <br />1 W-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />5/81 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />V1N. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. 7THR <br />Installtight totop flange.SLESTEM • FOR •• • . • • • <br />FOUNDATION INFO q ' d' ' • ' <br />STEM FOUNDATION <br />GRADE \ REINF. SEE PLAN Filler block. <br />Nail with <br />10-10d nails. <br />d <br />Backer block required where top E { <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />FUR A <br />d Q — <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />00 <br />I -JOISTS BUCKETS <br />N.T.S. <br />>1 <br />} r <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON 1OA.5i <br />(WHEN <br />w/ (18)10d REQUIRED) <br />NAILS <br />UPLIFT =1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />1'111'1r \ /r 1"1T1/1 A 1 TI lr'%i 1 r\ t11 <br />TOP (2) #5's x 4'-0" <br />PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />d d <br />Q d <br />•' d'd ' •d <br />CO ? \ • v• '••� <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />dam' d { dV L <br />a <br />A . <br />e 4 <br />e d o a <br />P <br />•e <br />SEE FND. PLN. <br />SIZE & REINF. <br />•+ <br />NSA • N <br />' <br />G� <br />Q G <br />FL <br />i���','�O <br />7"1111i ��`� �t <br />t1111 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />FW- � $ - <br />a W V <br />V 0 N °Np LL <br />M r <br />O <br />5_J LL_Jw <br />a 7U.N U. <br />di <br />■f M w N <br />a LL aaw <br />0zXo <br />Z �0VM <br />W09 Wm0 <br />°`��� <br />Q�� <br />�E�rn spa <br />�' sp co QO :1NaLo <br />ruZ U H <br />ILW <br />Z � � DO❑ <br />W <br />z � <br />z <br />d C. <br />c� z u <br />o <br />� � LL <br />. V W <br />� <br />o <br />V `- <br />0 <br />c <br />U� <br />� � o <br />U C° <br />a. W <br />• <br />W <br />M <br />lJL <br />z�o <br />i ii <br />� <br />Q <br />ce <br />aE <br />s <br />Z <br />oa <br />E' <br />(V <br />t� <br />CL <br />O <br />o <br />X U <br />ao <br />08 <br />z <br />N � <br />i <br />�o <br />ao <br />%z <br />.�-. <br />ffl <br />rj C <br />Hx <br />m� <br />F O <br />W <br />2, <br />z <br />� <br />yy a� <br />V) J <br />y <br />< b� <br />� <br />Z <br />�o <br />W <br />3: <br />8 <br />SOaLL <br />U <br />a <br />t <br />�r <br />05 <br />. � <br />yN <br />_T_ <br />ca <br />to <br />W <br />■ <br />Q <br />C <br />O <br />^' m <br />CEO <br />c <br />o <br />� <br />7—= <br />CD <br />0) <br />Z N <br />0 <br />T-- <br />L0 <br />r <br />I O) r <br />Qi O d' <br />E <br />-k . M <br />N N <br />Z <br />Z <br />E w <br />€ <br />a <br />ci ¢ o <br />JOB <br />NO : 20-2748 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.