2 <br />14 <br />RE <br />P <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />Must Provide U <br />( Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SO. IN. of <br />b Upper <br />y PPe <br />SQ, IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />See Elev <br />( ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />23.00000 <br />1.000000 <br />Floor <br />2008 <br />1928 <br />275 <br />964 <br />69 <br />482 <br />0 <br />483.0 <br />345.0 <br />138.0 <br />(Zone 1) <br />**NOTE — <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: Y4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />a <br />O <br />0 <br />0 <br />U in <br />z N <br />z <br />z g <br />N ''znn <br />V LL <br />LU <br />0 WW <br />t,n � <br />U <br />U <br />< m <br />;rs- <br />§t <br />f1 z <br />d N1 o <br />���Zos � <br />w <br />I <br />� W 0 = -1.t <br />Z O lox <br />LLto <br />LU <br />Q\N <br />L." A+ <br />_! ilj• <br />U 9� � <br />1?, INco <br />� <br />•• <br />0 <br />O F E <br />h rf+lEl111!ll�l <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Oth Edition. Engineer's signature and seal is orgy for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />co <br />M <br />w <br />J <br />L.L. <br />@ E <br />7� <br />z <br />o <br />> <br />�® <br />E <br />�0. <br />0 <br />go <br />� <br />w� <br />8U <br />z <br />O C <br />O E <br />N <br />t <br />°d z <br />°d go <br />Z <br />� lJl <br />m X <br />z <br />.N. <br />M <br />CO C <br />z <br />YU <br />W O <br />O <br />Zz <br />a Z <br />to <br />8 <br />U <br />U <br />°z <br />�W <br />= <br />0 <br />CDj <br />w <br />Lrpp <br />W 2 <br />pr <br />CC)ow <br />� <br />zlt <br />U 3 <br />0 <br />> M <br />L <br />> <br />Ln <br />•— <br />T— <br />M <br />.-. <br />> <br />O <br />Q <br />C o <br />N <br />m CU <br />= <br />r <br />LC� <br />O <br />r <br />LO <br />Lo r <br />o <br />� Lsn O � <br />T <br />ci <br />z <br />,Z• T M CV <br />3 M "' <br />o <br />C <br />E Q •' <br />- <br />C <br />0.0 <br />J Q 0 <br />J <br />JOB <br />NO: 19-5908 <br />SCALE : AS NOTED <br />SHEET NO. <br />5.0 <br />