My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36935 Highland Meadows Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36935 Highland Meadows Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 4:26:44 PM
Creation date
2/19/2025 3:57:50 PM
Metadata
Fields
Template:
Building Plans
Street #
36935
Location
Highland Meadows Ct
Contractor
Pulte Home Company
Building Plans - Permit #
2800
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF FRAMING PI_u,N <br />GENERAL NOTES <br />1. REFER TO ARCHITECTURAL DRAWINGS FOR WALL HEIGHTS, <br />2. REFER TO STRUCTURAL DETAILS FOR STEPPED MASONRY WALL HEIGHT <br />DETAIL <br />3. ALL INTERIOR CEIUNG SHEATHING TO BE GYPSUM. <br />4. REFER TO DETAILS FOR ALL WALL SHEATHING REQUIREMENTS. ALL <br />OTHER SHEATHING TO COMPLY WITH MINIMUM CODE REQUIREMENTS <br />U.N.O. IN THESE DRAWINGS. <br />5, FLOOR SHEATHING (IF APPLICABLE) SHALL BE %" MIN. <br />6. REFER TO DETAILS FOR ROOF SHEATHING REQUIREMENTS. <br />7. U.N.O. INTERIOR SHEATHNG TO BE GYPSUM AS REQUIRED IN <br />ARCHITECTURAL DRAWINGS. <br />& PROMDE SOLID BLOCKING FROM ALL BEAMS & GIRDERS TO FOUNDATION <br />BELOW. <br />TRUSS NOTES <br />UNLESS OTHERIWSE NOTED ON PLANS: <br />1. ALL TRUSS STRAPS TO MASONRY ARE TO BE METAI6. <br />2. ALL TRUSS TO FRAME SCREWS ARE TO BE THE FOLLOWING: <br />A) TRUSS TO TOP PLATE TO BE (2) SIMPSON SDWC15600, <br />By MULTI —PLY TRUSS REQURE (2)SDWC15600 AT EA PLY. <br />C) (1)SDWC15600 MAY BE USED ON JACK TRUSSES. <br />3. THESE PLANS ARE ENGINEERED BASED ON TRUSS LAYOUTS AND <br />ENGINEERING PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />CHANGES OR MODIFICATIONS ARE NOT PERMITTED WITHOUT A <br />LETTER FROM THE ENGINEER OF RECORD. <br />LEGEND <br />DETAIL INDICATOR <br />CROSS HATCHED AREA INDICATES EXTENT OF <br />GABLE END BRACING <br />TRUSS LAYOUT SHOWN ON THIS SHEET IS FOR EXAMPLE <br />PURPOSES ONLY TO ILLUSTRATE TRUSS TO WALL CONNECTIONS. <br />THIS LAYOUT HAS BEEN PROVIDED BY A THIRD PARTY FOR <br />EXAMPLE PURPOSES ONLY; THE ACTUAL TRUSS MANUFACTURER <br />LAYOUTS ARE TO BE USED FOR ALL STRAP LOCATIONS. PER <br />BUILDING CODE STATUTES, THE ROOF AND/OR FLOOR SYSTEM <br />HAS BEEN DELEGATED TO THE TRUSS MANUFACTURERS <br />PROFESSIONAL ENGINEER. <br />00o Fieldstone <br />C.O.A# ARCHITECTURE: Qi •' <br />AA26002802 • <br />C.O.A.# ENGINEERING: 2 L <br />29349 <br />0 BENJAMIN NIESE, PE <br />P.E.# 86025 <br />❑ IAN MCCULLOUGH, PE <br />P.E.# 80956 <br />08/26/2021 <br />DATE SIGNED <br />ATE O <br />AI. 0� <br />*PulteGrouy- <br />allow" <br />I RELEASE I <br />DATE: XX /XX /XXXX <br />H <br />PROJECT TYPE I <br />Sinde Family <br />I S�+,� TION LEVEL I <br />PLAN NAME <br />Hi h ate <br />NPC CHI'M NU ER <br />2811.500 <br />SHEET <br />S301 <br />
The URL can be used to link to this page
Your browser does not support the video tag.