A. GENERAL: <br />1. WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CDOE FLORIDA RESIDENTIAL BUILDING CODE 7th EDITION. <br />2. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWNGS. NOTES ON STRUCTURAL PLANS SHALL TAKE PRECEDENCE <br />OVER THE STRUCTURAL GENERAL NOTES ON THIS SHEET. <br />3. EXCEPT AS SHOWN ON STRUCTURAL DRAWINGS, REFER TO ARCHITECTURAL, ELECTRICAL PLUMBING AND MECHANICAL DRAWINGS FOR <br />DIMENSIONS, LOCATIONS, SIZES AND CONDITIONS, INCLUDING WINDOWS, DOORS, WALLS, CONCRETE CURBS, PITS, DRAINS, TRENCHES, <br />FLOOR AND ROOF SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, FLOOR AND ROOF OPENINGS, STAIRS, PIPE AND DUCT RUNS, <br />SLEEVES AND HANDERS, ELECTRICAL, CONDUITS AND OUTLETS, ITEMS EMBEDDED OR ATTACHED TO STRUCTURAL MEMBERS, EQUIPMENT, <br />BASES AND ANCHORAGE, ETC. <br />4. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. THE SEAL DOES NOT INCLUDE <br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, OR SAFETY PRECAUTIONS, WHICH SHALL REMAIN THE RESPONSIBILITY OF THE <br />CONTRACTOR. ALL DIMEN90NS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS OR DISCREPANCIES ON <br />THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER OF RECORD. BACKCHARGES WILL NOT BE ACCEPTED, <br />REGARDLESS OF FAULT, WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-HOURS AND INVESTIGATION BY FIELDSTONE. <br />5. ASTM SPECIFICATIONS INDICATED SHALL BE THE LATEST EDITIONS OF THE STANDARDS, UNLESS NOTED OTHERWISE. <br />6. ALTERNATE NAILING: PASLODE FASTENERS MAY BE USED ON SIMPSON HARDWARE. REFER TO SIMPSON TECHNICAL BULLETIN <br />T-PO91VENL06: POSITIVE PLACEMENT NAIL APPLICATIONS WITH PASLODE FASTENERS. <br />B. DESIGN CRITERIA: <br />1. DESIGN LOADS: <br />ROOF DEAD LOADS <br />METAL ROOF TC DEAD LOADS _---___-__-_-_ 10.0 PSF <br />SHINGLE ROOF TC DEAD LOADS _-_-------- 7.0 PSF <br />TILE ROOF TC DEAD LOADS -_-__ 15.0 PSF <br />ROOF BC DEAD LOADS __-_ _ 10.0 PSF <br />ROOF LIVE LOADS <br />TC LIVE LOAD ______-__--__- 20.0 PSF (REDUCIBLE) <br />BC LIVE LOAD w/o STORAGE ___ 10.0 PSF <br />BC LIVE LOAD w/ STORAGE 20.0 PSF <br />FLOOR DEAD LOADS 11.0 PSF <br />WOOD FRAMED DEAD LOAD---_11.0 PSF <br />FLOOR LIVE LOADS ----------------_-_--- 4RO PSF (REDUCIBLE) <br />BALCONY DEAD LOAD ____ 15.0 PSF <br />BALCONY LIVE LOAD 60.0 PSF <br />EXTERIOR WD WALL---18.0 PSF <br />INTERIOR WD WALL 7.0 PSF <br />STAIRS/LANDING __---__-__- 40.0 PSF <br />WIND SPEED PER ASCE 7-16 140 MPH <br />(THE NOMINAL WIND SPEED SHOWN HAS BEEN BASED ON LINEAR INTERPOLATION OF THE SITE LOCATION) <br />INTERNAL PRESSURE COEFFICIENT +/- 0.18 (FULLY ENCLOSED STRUCTURE) <br />RISK CATEGORY II <br />EXPOSURE 'C' <br />2. <br />ALL GUARDRAILS AND HANDRAILS SHALL MEET THE MINIMUM CODE REQUIREMENT WITHSTANDING A <br />MINIMUM 200 POUND CONCENTRATED POINT LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP. <br />ALL IN -FILL COMPONENTS OF THE GUARDRAIL SHALL BE DESIGNED TO WITHSTAND A MINIMUM HORIZONTALLY <br />APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO 1 SQUARE FOOT. THESE LOADS ARE TO BE <br />EVALUATED INDEPENDENTLY AND ARE NOT ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD. <br />DEFLECTION OF THIS GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE INTERNATIONAL CODE COUNCIL <br />EVALUATION SERVICES (ICC-ES) AC273 - ACCEPTANCE CRITERIA FOR HANDRAILS AND GUARDS. <br />C. <br />FOUNDATION: <br />1. <br />FOUNDATION IS DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. THE <br />CONTRACTOR SHALL VERIFY THAT THE MINIMUM BEARING CAPACITY OF 2000 PSF. IS PRESENT PRIOR TO FOOTING <br />PLACEMENT. <br />Z <br />ALL ALL SHALL BE CLEAN AND COMPACTED TO 95% BY HEAVY VIBRATORY ROLLER IN MAXIMUM LIFTS OF 8". CONFORM TO <br />ASTM D 1557. <br />3. <br />GRADING, SOIL PREPARATION AND FOUNDATION CONSTRUCTION SHALL COMPLY NTH THE REQUIREMENTS OF THE <br />GEOTECHNICAL REPORT AND THE BUILDING CODES NOTED ON THIS SHEET, <br />4. <br />FOOTING BACKFILL AND UTILITY TRENCH BACKRLL WITHIN BUILDING AREA SHALL BE MECHANICALLY COMPACTED IN LAYERS <br />PER GEOTECHNICAL REPORT. FLOODING WILL NOT BE PERMITTED. <br />5. <br />ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. <br />6. <br />PROVIDE MIN. 6 MIL APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6" AND SEALED. <br />D. <br />CONCRETE: <br />1. <br />CONCRETE SHALL CONFORM TO THE 'BUILDING REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318 LATEST EDITION) WITH 1 <br />MODIFICATIONS AS NOTED IN THE DRAWINGS AND SPECIFICATIONS. <br />2. <br />DESIGN BASED ON 2500 PSI, 28-DAY STRENGTH, UNLESS OTHERWISE NOTED. <br />3. <br />PROTECTION COVER (CLEAR) SHALL BE AS FOLLOWS ONO: : <br />a. CONCRETE PLACED DIRECTLY AGAINST EARTH - 3 INCHES CLEAR <br />SLABS ON GROUND - 1 1 2 INCHES CLEAR <br />b. STRUCTURAL LAB / <br />c. FORMED CONCRETE WITH EARTH BACK FILL - 2 INCHES CLEAR <br />d. WWM USED IN SLABS SHALL BE FULLY SUPPORTED USING CHAIR APPROVED BY THE MANUFACTURER IN THE <br />MIDDLE TO UPPER Y OF SLAB AT 3-FT SPACING OR IN ACCORDANCE w/MANUFACTURER'S SPECIFICATIONS <br />7. <br />ALL RONFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO <br />PLACING CONCRETE. <br />8. <br />PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY <br />REINFORCING WHICH MAY CONFLICT. <br />9. <br />CONCRETE PLACEMENT SHALL BE PER RECOMMENDATIONS IN AD 614, AD 301, AD 318 & ACI 33Z <br />10, <br />SLABS ARE DESIGNED AS UNREINFORCED PLAIN CONCRETE SLABS ON GROUND. <br />11. <br />ONE OF THE FOLLOWING METHODS Of CRACK CONTROL SHALL BE USED: <br />(.) CONTRACTION JOINTS, IF CONTRACTION JOINTS ARE USED, THEY SHALL BE CUT OR TOOLED IN THE SLAB A MINIMUM <br />OF 1'. ALL SAW CUTS ARE TO BE MADE WITHIN 24 HOURS OF THE CONCRETE PLACEMENT. <br />CONTRACTION JOINTS IN A 3.5' SLAB SHALL BE PLACED NO MORE THAN 8-FEET APART IN BOTH DIRECTIONS <br />CONTRACTION JOINTS IN A 4.0' SLAB SHALL BE PLACED NO MORE THAN 10-FEET APART IN BOTH DIRECTIONS <br />b.) 6x6 W1.4xW1.4 WELDED WIRE REINFORCEMENT FABRIC (WWW). <br />c.) MICRO- OR MACRO-SYNTHECTIC FIBER REINFORCEMENT. <br />FIBER LENGTHS SHALL BE )' TO 2 X N LENGTH. DOSAGE AMOUNTS SHALL BE FROM 0.75 TO 3.0 POUNDS IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM <br />C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WEN <br />REQUESTED BY THE BUILDING OFFICIAL <br />E. <br />MASONRY WALL CONSTRUCTION: <br />1. <br />MASONRY CONSTRUCTION SHALL COMPLY WITH LATEST EDITION OF TMS 402 & 602 / ACI 530 & 530.1 / ASCE 5 & 6. <br />2. <br />- - BEARING TYPE II MASONRY WITH UNIT STRENGTH OF 1900 i <br />MASONRY UNITS SHALL MEET ASTM G 90, GRADE N i FOR HOLLOW LOAD BEAR E ps <br />ON THE NET AREA (Pm = 1,500 psi). UNITS SHALL BE NORMAL WEIGHT, 8' x 8' x 16', TWO HOLE, SQUARE END BLOCKS UNLESS NOTED 1 <br />OTHERWISE. UNITS SHALL HAVE A ROUGH TEXTURE FOR STUCCO APPLICATION. <br />3. <br />ALL MORTAR SHALL CONFORM TO ASTM C 270, TYPE "S' OR V. 1 <br />4. <br />COURSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8' AND A MINIMUM COMPRESSIVE STRENGTH OF <br />2500 PSI. 1 <br />5. <br />VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS, WITH FILLED CELLS FILLED WITH COURSE GROUT. <br />6. <br />VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND THE BOTTOM AND AT A MAXIMUM SPACING OF 8'-0' U.N.O. 1 <br />REINFORCEMENT SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL, TYPICAL, UNLESS OTHERWISE NOTED. <br />7. <br />EXPAN90N TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 1 <br />8. <br />ALL MASONRY UNITS SHALL BE LAID IN RUNNING BOND U.N.O. <br />9. <br />OVER ALL MASONRY OPENINGS IN WALLS PROVIDE LINTELS, CAST -IN -PLACE CONCRETE BEAMS, OR OTHER HEADERS AS NOTED ON PLANS, <br />10. <br />VERTICAL FILLED CELLS SHALL HAVE A MINIMUM OF (1) #5 BAR LAPPED AND TED TO THE FOUNDATION DOWL, AND A STANDARD ACI <br />HOOK AT THE TOP, LAPPED AND TIED TO THE HORIZONTAL REINFORCING IN THE TOP OF THE WALL. SEE CHART BELOW FOR MINIMUM LAP <br />AND HOOK LENGTHS. <br />REINFORCING STEEL MINIMUM REQUIREMENTS <br />BAR SIZE <br />MINIMUM LAP <br />MINIMUM BEND DIA. <br />MINIMUM AD HOOK <br />14 <br />20' <br />3' <br />10" <br />#5 <br />25' <br />3-3/4" <br />10" <br />16 <br />34' <br />4-1/2' <br />11' <br />#7 <br />42' <br />5-1/4' <br />13" <br />F <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />N <br />REINFORCING STEEL: <br />WALL BARS AND COLUMN BARS SHALL CONFORM TO ASTM A-615, GRADE 60. FOOTING BARS AND BOND BEAM BARS SHALL <br />CONFORM TO ASTM A-615, GRADE 40 OR GRADE 60. <br />BAR BENDS SHALL BE MADE COLD, IN STRICT ACCORDANCE WITH THE DRAWINGS AND C.R.S.I. LATEST EDITION. NO KINKS <br />ALLOWED. SEE CHART FOR STANDARD HOOK SIZES. <br />REBAR LAP SPLICES ARE TO BE: CLASS W. MINIMUM LAP LENGTH SHALL BE PER CHART UNLESS NOTED OTHERWISE MINIMUM <br />LAP OF WELDED WIRE FABRIC SHALL BE 6 INCHES OR ONE FULL AND HALF MESH, WHICHEVER IS GREATER. <br />FIELD WELDING OF REINFORCING BARS IS NOT PERMITTED, UNLESS NOTED OTHERWISE <br />DOWELS BETWEEN FOOTINGS SHALL BE THE SAME SIZE AND SPACING OR NUMBER AS THE HORIZONTAL REINFORCING. <br />DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME SIZE AND SPACING OR NUMBER AS THE VERTICAL <br />REINFORCING. <br />TOLERANCE FOR REBAR DEPTH AND CONCRETE COVER IN FLEXURAL MEMBERS, WALLS, DISCONTINUOUS ENDS OF MEMBERS, AND <br />COMPRESSION MEMBERS SHALL BE AS FOLLOWS: <br />TOLERANCE ON d <br />TDLERANCE ON SPECIFIED <br />CONCRETE COVER <br />d<--8 in <br />+/- 3/8' <br />-3/8" <br />d>=8 b <br />+/- 1/2' <br />-1/2' <br />TOLERANCE FOR LONGITUDINAL LOCATION PLACEMENT OF BENDS AND ENDS OF REINFORCEMENT SHALL BE +/- 2' <br />WOOD FRAMING: <br />FRAMING LUMBER SHALL BE SURFACE DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS REQUIREMENTS OF ALL <br />WOOD MEMBERS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NDS. <br />EXTERIOR WALL LUMBER, U.N.O. ON THE PLANS, 2x4 (MIN) SPF OR SP NUMBER 2 OR BETTER 0 16' O.C. FOR WALLS 9'-5' OR LESS. <br />INTERIOR LOAD BEARING WALLS SHALL BE 2x4 SPF OR SP NUMBER 2 OR BETTER 0 16' O.C. MAX. (U.N.O.). <br />INTERIOR NON -LOAD BEARING WALLS SHALL BE 2x4 SPF, SP, OR METAL STUDS ® 24" O.C. MAX. <br />LUMBER IN CONTACT WITH GROUND, CONCRETE, OR MASONRY SHALL BE SOUTHERN PINE PRESSURE TREATED. <br />HEADER FRAMING: <br />a.) HEADER SIZES SPECIFIED ON SCHEDULES AND/OR PLANS ARE MINIMUM REQUIREMENTS AND CAN BE UPGRADED TO LARGER <br />SIZE OF SAME SPECIES, GRADE AND PLY COUNT. <br />b.) FOR 2x4 STUD WALL PROVIDE (1) 2x4 KING STUD AND (1) 2x4 TRIMMER AT EACH END OF (2) PLY HEADER, U.N.O. <br />c.) FOR 2x6 STUD WALL PROVIDE (1) 2x6 KING STUD AND (1) 2x6 TRIMMER AT EACH END OF (3) PLY HEADER, U.N.O. <br />STUD COLUMNS UNDER BEARING POINTS OF GIRDER TRUSSES OR BEAMS SHALL MATCH PLY COUNT WITH )' TOLERANCE (2-PLY MIN), <br />UNLESS NOTED OTHERWISE. AT MULTIPLE 2x STUDS OR TRIMMERS, USE FACE NAIL 16d G.N. AT 8" O.C. FOR EACH, U.NO. <br />SEE FRAMING PLAN FOR DOUBLE TOP PLATE 9'UCE CONDITIONS. A 2X6 MAY BE RIPPED DOWN TO A 2X4 AT POINTS WHERE THE TOP <br />PLATE CHANGES FROM 2X4 TO 2X6 N LIEU OF ANY CONNECTING STRAP CALLED OUT ON PLAN. <br />ALL BEAMS AND HEADERS, DIMENSIONAL AND ENGINEERED WOOD, SHALL BE A MINIMUM OF (2) PLY UNLESS NOTED OTHERWISE <br />ALL TOP LOADED BEAMS AND HEADERS SHALL BE NAILED WITH (3) ROWS 16d GUN NAILS OR 12d COMMON NAILS (MIN) AT 12' O.C. <br />UNLESS NOTED OTHERWISED. <br />ENGINEERED LUMBER, SHALL BE I -LEVEL PRODUCTS OR EQUAL TYPE, SIZE PER PLANS. Fb = 3,100 psi MINIMUM. <br />GUN NAILS ARE ALLOWED FOR ALL WOOD -TO -WOOD CONNECTIONS. COMMON NAILS AS SHOWN IN THE ABBREVIATIONS ON THIS PAGE <br />SHALL BE USED FOR METAL -TO -WOOD CONNECTIONS. <br />H. PREFABRICATED WOOD TRUSSES: <br />1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. THESE ARE PRELIMINARY LAYOUT USED ONLY TO DEPICT THE <br />TRUSS CONNECTORS THAT DO NOT MEET THE SPECIFICATIONS OF THE TYPICAL CONNECTOR AS SHOWN IN THE TRUSS LEGEND, LAYOUTS, <br />TRUSS UPLIFTS, TRUSS REACTIONS, PLY COUNTS AND TRUSS -TO -TRUSS CONNECTIONS ARE TO BE PROVIDED BY THE DELEGATED ROOF AND <br />FLOOR SYSTEM ENGINEER. <br />2. TOP PLATE HEIGHTS MAY VARY. SEE BUILDING SECTIONS, WALL SECTIONS AND ELEVATIONS FOR BEARING HEIGHTS. <br />3. TRUSS SPACING SHALL BE 24" O.C. MAX. UNLESS OTHERWISE NOTED, CONVENTIONAL FRAMING SHALL BE 16" (INCHES) D.C. MAX. OR AS <br />OTHERWISE NOTED. <br />4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON -BEARING WALLS AND AT VOLUME AREA UNLESS OTHERWISE NOTED. <br />5. ALIGN TRUSSES AND HAND FRAMING SD ALL GYPSUM WALL BOARD WILL BE CONTINUOUS FROM FLOOR TO CEILING. <br />6. PROVIDE BRACING AND BLOCKING PER BCSI-B3 IN ADDITION TO BRACING AND BLOCKING SHOWN ON TRUSS LAYOUTS PROVIDED BY THE <br />DELEGATED TRUSS SYSTEM ENGINEER. <br />7. PROVIDE 30 LB. FELT PAPER OR OTHER MOISTURE BARRIER AT ALL CONTACT POINTS BETWEEN TRUSS /NON P.T. WOOD AND MASONRY. <br />8. ROOF TRUSS TOP & BOTTOM CORD SHALL BE SOUTHERN YELLOW PINE (SP). THE GRADE SHALL BE DETERMINED BY THE DELEGATED <br />TRUSS ENGINEER. <br />9. ALL TRUSS -TO -TRUSS CONNECTIONS, BOTH GRAVITY AND UPLIFT, ARE DELEGATED TO THE TRUSS SYSTEM ENGINEER AND CALLED FOR ON <br />THE MANUFACTURER'S LAYOUTS. <br />ANCHORAGE: <br />SILLS OR PLATES RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER. CAST -IN -PLACE BOLTS <br />SHALL BE 1/2' DIA, EMBEDDED 7. USE 10' LONG ANCHOR BOLTS AT 2x PLATE UNLESS OTHERWISE NOTED. ANCHOR <br />BOLTS SHALL BE FULL BODY AND HAVE CUT THREADS OR NOMINAL DIAMETER WITH ROLLED THREADS. 3'x3'xO.229' PLATE <br />WASHERS. <br />2 EXPANSION ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 MO ICC-ES AC193. PRE -APPROVED <br />EXPANSION ANCHORS SHALL BE SIMPSON STRONG -BOLT Z. <br />A T THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED <br />3. SCREW ANCHORS IN CONCRETE SH LL MEET QU <br />• SIMPSON `DTEN HD. CAN ONLY BE INSTALLED IN DRY INTERIOR OR NON -CORROSIVE <br />SCREW ANCHORS SHALL BE. , <br />ENVIRONMENTS, NOT FOR EXTERIOR EXPOSED APPLICATIONS. <br />4. ADHESIVE ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.4 AND ]CC -ES AC308. PRE -APPROVED <br />ADHESIVE ANCHORS SHALL BE SIMPSON 'SET-XP' OR SIMPSON 'AT-XP'. SIMPSON 'AT-XP' MAY BE SUBSTITUTED FOR <br />SIMPSON 'SET-XP'. <br />5. ANCHORS FOR INTERIOR NON -SHEAR WALLS EXPERIENCING ONLY GRAVITY FORCES ARE AS FOLLOWS: <br />a) POWDER -ACTUATED FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ICC-ES AC70. PRE -APPROVED <br />POWDER -ACTUATED FASTENERS SHALL BE SIMPSON 'POWDER -ACTUATED FASTENERS'. <br />b) SCREW FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED <br />CONCRETE SCREWS SHALL BE: SIMPSON `FITEN SCREWS'. <br />6. ADHESIVE ANCHORS IN HOLLOW MASONRY WALLS SHALL MEET THE REQUIREMENTS OF ICC-ES AC58. PRE -APPROVED <br />ADHESIVE ANCHORS SHALL BE: SIMPSON 'SET'. <br />7. INSTALL ALL POST -INSTALLED ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION <br />INSTRUCTIONS AND CURRENT FLORDA PRODUCT APPROVAL <br />8. PRE -APPROVED SUBTTUTIONS FOR 1/2' DIA CAST -IN -PLACE ANCHOR BOLTS AT INTERIOR WALLS ARE AS FOLLOWS: <br />a) 1/2' DIA. SIMPSON 'STRONG -BOLT 2'W/ MIN. 2 3/4' EMBEDMENT DEPTH AND fEDGE DISTANCE <br />b) 1/2' DIA. SIMPSON `TITEN HD'W/ MIN. 3 1/4' EMBEDMENT DEPTH AND 1 3/4'EDGE DISTANCE. <br />c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER <br />POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. <br />9. PRE -APPROVED SUBTITUTIONS FOR 1/2' DIA. CAST -IN -PLACE ANCHOR BOLTS AT EXTERIOR WALLS ARE AS FOLLOWS: <br />a) 1/2" DIA. SIMPSON 'TITEN HD'W/ MIN. 3 1/4' EMBEDMENT DEPTH AND 1 3/4'EDGE DISTANCE. <br />b) SET-XP EPDXY w/ 4' EMBEDMENT AN 1/2' DIA. F1554 GR. 36 ATR W/ NUT & WASHER. <br />c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER <br />POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS, <br />0. PLACE ANCHOR BOLTS AT 4' MIN AND 12" MAX FROM SILL PLATE END OR FROM A NOTCH GREATER THAN 1/2 THE WIDTH <br />OF THE PLATE, A MINIMUM OF 1 3/4" FROM CONCRETE EDGE, AND SPACED AT 24" O.C. MAX. <br />1. SILL PLATES SHALL BE TREATED WITH DISODIUM OCTABORATE TETRAHYDRATE (DOT) (NER 648) OR ANOTHER LOW <br />CORROSIVE CHEMICAL TREATMENT. <br />2. DO NOT NOTCH OR BORE LARGE HOLE AT JOISTS, RAFTERS, BEAMS OR PLATES, UNLESS NOTED OTHERWISE. OBTAIN <br />APPROVAL FROM ENGINEER FOR NOTCHES AND HOLES NOT DETAILED. <br />3. BOLT HOLES SHALL BE 1/16' MAXIMUM LARGER THAN THE BOLT SIZE. USE STANDARD CUT WASHERS UNDER BOLT HEADS <br />OR NUTS AGAINST WOOD. <br />4. CONNECTION HARDWARE SHAD_ BE SIMPSON STRONG -TIE <br />J. WOOD STRUCTURAL SHEATHING: <br />1. SEE STRUCTURAL DETAILS FOR SIZES AND TYPES OF SHEATHING. <br />K. FIELD REPAIR NOTES: <br />1. MISPLACED DOWEL NOTE <br />THIS NOTE IS TO DESCRIBE ALTERNATIVES TO MITIGATE FOR CASTING 15 REBAR VERTICAL REINFORCING AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT. DRILL A r DIA. HOLE 6' DEEP INTO THE THICKENED EDGE OF THE SLAB AT THE CORRECT <br />LOCATION. EPDXY A 36' LONG #5 REBAR WITH SIMPSON TYPE 'SET' EPDXY INTO THE DRILLED HOLE. FOLLOW THE MANUFACTURER'S <br />REQUIREMENTS REGARDING CLEANING THE HOLE AND MIXING THE EPDXY. AS THE WALL IS BUILT LAP REBAR PER REINFORCING STEEL <br />SCHEDULE (IN GENERAL NOTES) AND BEND VERTICAL BAR 90 DEGREES TO ACHIEVE A 12' LONG LAP WITH THE CONTINUOUS REBAR IN <br />THE TIE BEAM. <br />IF THE WALL HAS BEEN BUILT, PRIOR TO LINTEL PO JR, OPEN THE WALL AT THE CORRECT LOCATION APPROX. 16' HIGH AND 4" WIDE AT <br />THE FLOOR. DRILL HOLE AND INSTALL A 32' LONG REBAR AS DESCRIBED ABOVE LAP VERTICAL STEEL AS DESCRIBED ABOVE INTO TIE <br />OR BOND BEAM. <br />FORM WALL AND POUR DOWNPOUR SOLID WITH GROUT AS SPECIFIED. <br />2. M159NC OR MISPLACED ANCHOR BOLT (ALTERNATE BOLTING FOR WOOD SOLE PLATES). <br />THIS NOTE IS TO DESCRIBE ALTERNATES TO ANCHOR BOLTS IN THE SLAB AND BOND BEAM BUT DOES NOT APPLY AT STEP DOWN <br />AND/OR CURB CONDITIONS. <br />2.1 IF THE BOLT TO BE INSTALLED IN THE SLAB MEETS THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED BY THE <br />MANUFACTURER, OR IS AT LEAST 2-Y FROM ANY EDGE FOR N BOLTS AND 3-Y" FOR )' AND r BOLTS, THEN A <br />STANDARD EXPANSION BOLT EMBEDDED 5" MINIMUM AND THE SAME DIA. AS THE SPECIFIED ANCHOR BOLT MAY BE USED <br />(SPACING FOR BOLTS AT WOOD SOLE PLATES SHALL BE REDUCED FROM 24' TO 16�. <br />2.2 IF THE BOLT TO BE INSTALLED IN THE SLAB DOES NOT MEET THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED ABOVE <br />OR IS TO REPLACE BOLTS SPECIFIED IN BOND BEAMS THEN INSTALL AN TITEN HD AT THE SAME SPACING AS SPECIFIED ON <br />THE PLANS. TITEN HD SHALL BE A MINIMUM Y" x 6, OR AS REQUIRED ON THE DRAWINGS. ALTERNATE CONNECTION IS AN <br />ANCHOR W/SIMPSON TYPE 'SET' EPDXY THE SAME SIZE AS THE ONE BEING REPUCE W/ A 6' MINIMUM EMBEDMENT <br />SLEEVE ANCHORS ARE NOT ALLOWED. <br />3. MISSING OR MISPLACED TRUSS STRAP ANCHOR <br />SEE THE DETAIL IN THESE DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN 1 1/2" FROM THE FACE CE THE TRUSS, A SHIM <br />MUST BE PROVIDED AND NAILS SHALL BE INCREASED TO GO THROUGH BOTH PLYS OF MATERIAL (I.E. 3" NAILS). WHEN CAP IS <br />GREATER THAN 1 1/2", INSTALL NEW ANCHORS. <br />4. CMU OVERHANGING SLAB <br />4.1 FOR BLOCK OVERHANGING THE SLAB BY V OR LESS, NO REPAIR IS NECESSARY. <br />4.2 FOR BLOCK OVERHANGING THE SLAB BETWEEN V AND 1 r, GROUT THE BOTTOM 3 COURSES OF IN AFFECTED AREA OF WALL. <br />4.3 FOR BLOCK OVERHANGING THE SLAB BY MORE THAN 1 )�, CONTACT THE E.O.R. FOR REPAIR. <br />5. NOTCHED STUDS IN WALLS <br />STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH GREATER THAN 25% OF THE WIDTH IN BEARING <br />WALLS, OR 40% IN NON -LOAD BEARING WALLS; OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD <br />WIDTH IN BEARING WALLS (1-3/8-FOR A 2X4 STUD OR 2-3/16-FOR A 2X6 STUD), OR 60% OF THE STUD WIDTH IN NON -BEARING <br />WALLS (2-1/8'FOR A 2X4 STUD OR 3-V16'FOR A 2X6 STUD). IF THE MAXIMUM HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN <br />A MD SHOE MUST BE INSTALLED. STUD SHOE REPAIRS ARE AS FOLLOWS. FOR 2X STUD USE HSS2-SDS1.5 WITH (12)-1/41X1-1/2' <br />SDS SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-'#'-SDS3 WITH (1 2)-1/4N3' SOS SCREWS, WHERE ''CORRESPONDS TO THE <br />NUMBER OF STUDS IN THE MULTI -PLY. <br />6. NOTCHED TOP/BOTTOM PLATES <br />0. FOR PLUMBING/MECHANICAL UTILITIES <br />A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS REMOVED FOR PIPING (EXCEPT WHEN THE SIDE <br />OF THE WALL WITH THE NOTCH OR CUT IS COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT <br />THROUGH. THE REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-1/2-WIDE AND MUST BE <br />FASTENED WITH (8}-16D NAILS ON EACH SIDE OF THE OPENING (EX RPS). PROTECTION OF PIPING WITHIN THE WALL IS <br />REQUIRED WHEN PIPING OTHER THAN CAST IRON DR GALVANIZED STEEL (I.E. PVC OR ABS) IS CLOSER THAN 1-1/2-TO THE <br />EDGE OF THE PLATE, OR PLASTIC AND COPPER PIPING IS CLOSER THAN 1-FROM THE EDGE OF THE PLATE. THE REQUIRED <br />REPAIR IS A GALVANIZED 167GAUGE STEEL PROTECTIVE PLATE THAT COVERS THE SIDE OF THE PLATE AND <br />EXTENDS 2-ABOVE/BELOW IT (OR AS AN APPROVED ALTERNATE, A STEEL PROTECTIVE PLATE NOT LESS THAN 18 GAUGE THAT <br />EXTENDS 1-1/2-BEYOND THE PIPE ON EACH 901). <br />b. FOR HVAC UTILITIES <br />REPAIR IS THE SAME AS MENTIONED ABOVE FOR PLUMBING/MECHANICAL UTIVES EXCEPT WHEN THE ENTIRE PLATE IS REMOVED <br />FOR DUCTWORK A 16-GAUGE METAL TIE SHOULD BE INSTALLED ON BOTH SIDES OF THE CUT PLATE. WHERE THE TOP PLATE <br />HAS BEEN REMOVED FROM TWO (2) CONSECUTIVE BAYS, A 3' WIDE STRAP THAT SPANS BOTH BAYS IS REQUIRED (EX. <br />MSTC52) <br />L. JURISDICTION SPECIFIC INFORMATION: <br />1. FOR ALL PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO, LANAIS, PORCHES AND BALCONIES, 5/8-MINIMUM EXTERIOR <br />GRADE SOFFIT BOARD WITH A CEMENTTTIOUS KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE THE SOFFIT BOARD WOULD NEED TO BE FASTENED AT 7' ON <br />CENTER AND ALL ENDS BLOCKED PER MANUFACTURER SPEC AND GYPSUM ASSOCIATION 216 (GA-216) INSTALLATION GUIDELINES. THIS <br />APPLICATION WOULD BE IN COMPLIANCE WITH R703.1. <br />2. SOFFIT, OTHER THAN THE EXTERIOR GRADE SOFFIT BOARD OR SOFFITS USING HIGH -RIB METAL LATH AND STUCCO, SHALL HAVE THE <br />PRODUCT APPROVAL NOTED ELSEWHERE WITHIN THE CONSTRUCTION DOCUMENTS SUBMITTED. ALL ALUMINUM OR VINYL SOFFITS SHALL <br />MEET OR EXCEED THE REQUIREMENTS NOTED ON THIS SHEET IN REGARD TO DESIGN PRESSURES. ALL ALUMINUM MUST BE INSTALLED <br />IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS TO COMPLY WITH THESE MINIMUM DESIGN PRESSURES. INSTALLATION IN <br />ACCORDANCE WITH THESE REQUIREMENTS WILL COMPLY WITH R703 AND R704. ALL VINYL SOFFIT SHALL COMPLY WITH THE <br />MANUFACTURER'S INSTALLAEDN INSTRUCTIONS AND R704. <br />r <br />' <br />Roof Pressures <br />Wall & Soffit Pressures <br />Zone 1 <br />Zone 2 <br />Zone 3 <br />Zane 4 <br />Zone 5 <br />19" 2 <br />-34.4 <br />N/A <br />N/A <br />19.2 <br />-47. 5 <br />25.8 <br />-27. 8 <br />25.8 <br />- 34. 4 <br />Zone 2e <br />Zone 3e <br />N/A N/A <br />Zone 3r <br />N/A N/A <br />19.2 <br />-47.5 <br />Zone 2n <br />N/A <br />N/A <br />Zone 2r <br />19.2 <br />-47.5 <br />DESIGN PRESSURE CALCS <br />DESIGN PRESSURES SHOWN ARE MINIMUM ALLOWABLE <br />VALUES. VALUES ARE TO BE INCREASED AS <br />REQUIRED BY MORE STRINGENT LOCAL REQUIREMENTS <br />- <br />i y � la +d l M , � . ., , . , ,. , ur <br />_ -� <br />Positive Ne ati>ve <br />Width Height_i Effective Pressure Pressure <br />description Zone Lftj Lftj `AreaJfQ)< fpsf <br />16070 OHGD <br />- <br />16 <br />7 <br />112 <br />21.9 <br />-24.4 <br />3080 DOOR <br />4 <br />3 <br />8 <br />24.0 <br />24.4 <br />- 26.5 <br />6080SGD <br />5 <br />6 <br />8 <br />48.0 <br />23.2 <br />- 29.3 <br />4010 IF WED <br />4 <br />4 <br />1 <br />4.0 <br />25.8 <br />-27.8 <br />25SH <br />4 <br />3 <br />S.25 <br />15.8 <br />25.1 <br />-27.2 <br />24SH <br />4 <br />4 <br />4.166667 <br />16.7 <br />2S.0 <br />-27.1 <br />25SH (2) END <br />5 <br />6 <br />S. 25 <br />31.5 <br />24.0 <br />-30.9 <br />25SH END <br />5 <br />3 <br />5.25 <br />15.8 <br />25.1 <br />-33.1 <br />( 2) 26SH END <br />5 <br />1 6 <br />1 6 <br />36.0 <br />1 23.8 <br />-30.5 <br />25SH It3 <br />4 <br />1 9 <br />1 5.25 <br />1 47.3 <br />1 23.2 <br />1 -25.3 <br />,t1111111/ <br />000Fiel&tone <br />....- <br />V. <br />C.O.A# ARCHITECTURE: <br />QJ► •' <br />AA26002802 <br />C.O.A.# ENGINEERING: <br />No. 880 S <br />29349 <br />BENJAMIN NIESE, PE <br />P.E.# 86025 <br />❑ IAN MCCULLOUGH, PE <br />P.E.# 80956�ORvD <br />ST F Qj <br />• ' ��`� <br />08/23/2 1 <br />''AL <br />/1111 <br />u <br />*PulteGroupr <br />PRODUCT MANAGER <br />RELEASE <br />[Mli1Tlm-1121 <br />SPECIFICATION LEVEL <br />Puite <br />NPC FPLANNAME <br />ER <br />SHEET <br />S0.1 <br />