My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39661 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39661 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:21:54 PM
Creation date
2/19/2025 3:58:50 PM
Metadata
Fields
Template:
Building Plans
Street #
39661
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1053
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-1 1 /7\ <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />0 <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />HETA20 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 112" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 1 Old x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 1Od x 1 1/2"& 8-1 Od <br />H <br />HTT4 <br />3610 <br />3105 <br />5/8" ANCH. /(18) 10dx1-1/2 <br />HTT4 <br />4215 <br />5/8" ANCH. /(18) 10d x1-1/2 <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 1 Odx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 1 Od x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />HD5B * <br />4505 <br />3785 <br />5/8" ANCH. 3/4" STUD BOLTS <br />TDX6 <br />5350 <br />--- <br />2 - 7/8" DIA. BOLTS <br />M <br />HD7B * <br />6645 <br />5650 <br />7/8" ANCH. 3/4" STUD BOLTS <br />TDX10 <br />10140 <br />--- <br />4 - 7/8" DIA. BOLTS <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 1Od x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-1 Od x 1-112" <br />S <br />MTS16 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW16 <br />1195 <br />1005 <br />14-1 Od x 1-1/2" <br />T <br />MTS20 <br />990 <br />860 <br />14 - 1 Od x 1 1/2" <br />MTW20 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />U <br />MGT <br />3965 <br />3330 <br />22 -1 Old x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />LGT2 <br />2030 <br />1750 <br />(16)16d SINKERS & (7) <br />1/4" x 2-1/4" TITENS <br />LUGT2 <br />1550 <br />1550 <br />(16)1Old NAILS AND (5) <br />1/4" x 3" WEDGE BOLTS <br />"X" HTS 20 1310 1245 24-1 Od x 1 1/2" HTW20 1530 1 1285 24-1Od x 1 1/2" <br />SP1 555 535 10 - 10d I SPT22 735 8 - 10d <br />SP2 1010 605 12-10d SPT24 1090 12-10d <br />HCP2 1 590 1 555 12-1 Old x 1 1/2" HHCP2 680 570 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 10-17.19 <br />LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (6) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW, FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (-). <br />INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES, R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 6-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS <br />1 (2) - 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />SEE SHEET D-1 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />r <br />0 W N <br />•p <br />Cle <br />W <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />A_ <br />Q <br />v <br />O 8 <br />w r- <br />co (NO W <br />ik <br />co <br />®, <br />a)U <br />'� c) rA <br />U <br />U"D <br />.J W <br />u_ -ja <br />y <br />aS <br />LL LL <br />rn <br />a a x <br />13Z <br />J <br />@�M <br />0�o <br />ij <br />t o <br />z M N �p <br />ofm 0 <br />m m <br />t W <br />r°2ajO' <br />J Q a <br />$ Z <br />N M¢ <br />U <br />00 <br />0 <br />z <br />❑❑❑ <br />W <br />�v <br />CD M <br />z N M <br />o � <br />z Co <br />N <br />z o � <br />� <br />Q � <br />J <br />CZ � <br />r <br />cn <br />M <br />z <br />a <br />u <br />0 <br />Ln <br />W <br />v <br />W <br />p-- J E <br />= w d <br />) °J <br />N m <br />• <br />rD <br />C7 <br />C.0 <br />� <br />W <br />z <br />C3 <br />Cl) <br />-0 <br />o <br />< <br />z <br />U- <br />Q E <br />E O <br />z o <br />o� <br />z� <br />?® <br />❑a <br />c6� <br />� <br />_ <br />O Q <br />�F <br />UO <br />p U <br />U <br />O 9_ <br />n z <br />0 <br />a z <br />i <br />" tti <br />U C <br />¢ a <br />0, <br />U <br />m 0 <br />0, <br />z <br />Q W <br />r) <br />UE <br />F <br />U1 <br />z z <br />g0 <br />man <br />I <br />10 <br />a <br />w <br />U <br />r� <br />k <br />oLL <br />W <br />3 <br />=r <br />CD <br />rl <br />w <br />z< <br />, <br />a� <br />U01 <br />0 <br />c CO <br />= <br />I> <br />N <br />co <br />j <br />M <br />O <br />CL <br />W <br />rn <br />o <br />' t <br />r, <br />co Np <br />�± <br />= N <br />r— <br />(7) <br />-.1- <br />N <br />rn <br />� <br />M <br />a; <br />E <br />N <br />co <br />o <br />z <br />co <br />EO <br />Cn <br />C <br />a <br />0 � <br />Q O <br />-j <br />JOB NO: <br />20-6584 <br />SCALE <br />: <br />AS NOTED <br />SHEET <br />NO. <br />7 <br />9 <br />